Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "frequency measurement" wg kryterium: Temat


Tytuł:
Characteristic pulse detection method for fuzzy area
Autorzy:
Geng, Xin
Du, Baoqiang
Powiązania:
https://bibliotekanauki.pl/articles/2173662.pdf
Data publikacji:
2022
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
frequency measurement
group period
phase coincidence fuzzy area
measurement gate
pomiar częstotliwości
okres grupowy
obszar rozmyty koincydencji faz
bramka pomiarowa
Opis:
In order to achieve higher frequency measurement accuracy, this paper proposed a characteristic pulse detection method of fuzzy area based on the quantized phase processing method of different frequency groups. First, the fuzzy area of the group phase coincidence points continuously moved on the time axis after passing through delay elements. The moving distance, that is, the number of the delay elements was determined by the main clock cycle of the D flip-flop. After that, three groups of phase coincidence detection fuzzy areas in different positions were sent to the digital logic module to extract the edge pulses of the phase coincidence detection fuzzy area. The pulse width is determined by the difference between the clock cycles of the delay elements. The clock cycles of different delay units were adjusted to obtain nanosecond or even picosecond circuit detection resolution. Finally, the pulses generated at the edge of the phase coincidence fuzzy area are taken as the switching signal of the frequency signal counter, so the stability of the gate signal and the accuracy of the gate time measurement are improved. The experimental results show that frequency stability can reach the order of E–13/s. In addition, compared with the traditional measurement method, it is characterized by simple structure, low cost, low noises, and high measurement resolution.
Źródło:
Bulletin of the Polish Academy of Sciences. Technical Sciences; 2022, 70, 2; art. no. e140553
0239-7528
Pojawia się w:
Bulletin of the Polish Academy of Sciences. Technical Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Frequency-to-code converter with direct data transmission
Przetwornik częstotliwość-kod z bezpośrednią transmisją danych
Autorzy:
Warda, Piotr
Powiązania:
https://bibliotekanauki.pl/articles/2174748.pdf
Data publikacji:
2022
Wydawca:
Politechnika Lubelska. Wydawnictwo Politechniki Lubelskiej
Tematy:
frequency
digital period measurement
frequency-to-code converter
microcontroller
częstotliwość
cyfrowy pomiar okresu
przetwornik częstotliwości na kod
mikrokontroler
Opis:
Signal frequency is one of the most popular information carriers in measurement technology. A circuit called a frequency-to-code converter is used to convert frequency into numerical values. Frequency-to-code converters usually operate in the mode of a recorder of a certain number of periods of the signal under test. Often it is a microcontroller-based circuit that uses built-in memory to collect measurement data. The size of the memory limits the measurement capabilities of the transmitter. The paper presents the development of a frequency-to-code converter that sends measurement data directly to the host computer without collecting the results in the RAM of the converter. The working algorithm of the transmitter is presented. The results of measurement experiments carried out for sample signals of constant and variable frequency are presented.. The metrological analysis of the results is presented.
Częstotliwość sygnału jest w technice pomiarowej jednym z popularniejszych nośników informacji. Do konwersji częstotliwości w wartości liczbowe używa się układu zwanego przetwornikiem częstotliwość-kod. Przetworniki częstotliwość-kod zwykle pracują w trybie rejestratora określonej liczby okresów badanego sygnału. Często jest to układ oparty o mikrokontroler wykorzystujący wbudowaną pamięć do gromadzenia danych pomiarowych. Rozmiar pamięci ogranicza możliwości pomiarowe przetwornika. W artykule zaprezentowano opracowanie przetwornika częstotliwość-kod przesyłającego bezpośrednio dane pomiarowe do komputera nadrzędnego bez gromadzenia wyników w pamięci RAM przetwornika. Zaprezentowano algorytm pracy przetwornika. Przedstawiono wyniki przeprowadzonych eksperymentów pomiarowych dla przykładowych przebiegów o stałej i zmiennej częstotliwości. Przedstawiono analizę metrologiczną wyników.
Źródło:
Informatyka, Automatyka, Pomiary w Gospodarce i Ochronie Środowiska; 2022, 12, 4; 74--77
2083-0157
2391-6761
Pojawia się w:
Informatyka, Automatyka, Pomiary w Gospodarce i Ochronie Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Implementation of Goertzel-based frequency estimation for power quality monitoring in embedded measurement systems
Autorzy:
Rodrigues, Nuno M.
Janeiro, Fernando M.
Ramos, Pedro M.
Powiązania:
https://bibliotekanauki.pl/articles/2173880.pdf
Data publikacji:
2022
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
power quality
frequency estimation
non-integer Goertzel
frequency interpolation
embedded measurement systems
Opis:
International standards from IEC and IEEE regulate power grid parameters such as the RMS value, frequency, harmonic and interharmonic distortion, unbalance or the presence of transients, that are important to assure the quality of distributed power. Standard IEC 61000-4-30 suggests the zero crossing algorithm for the measurement of the power grid frequency, but also states that different algorithms can be used. This paper proposes a new algorithm, the Fractional Interpolated Discrete Fourier Transform, FracIpDFT, to estimate the power grid frequency, suitable for implementation in resource limited embedded measurement systems. It is based on the non-integer Goertzel algorithm followed by interpolation at non-integer multiples of the DFT frequency resolution. The proposed algorithm is validated and its performance compared with other algorithms through numerical simulations. Implementation details of the FracIpDFT in an ARM Cortex M4 processor are presented along with frequency measurement results performed with the proposed algorithm in the developed system.
Źródło:
Metrology and Measurement Systems; 2022, 29, 3; 455--468
0860-8229
Pojawia się w:
Metrology and Measurement Systems
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Dynamic response of the Stuttgart TV Tower measured by classical instruments and GPS technology
Pomiary odpowiedzi dynamicznej wieży telewizyjnej w Stuttgarcie za pomocą klasycznych przyrządów pomiarowych i technologią GPS
Autorzy:
Breuer, Peter
Chmielewski, Tadeusz
Górski, Piotr
Powiązania:
https://bibliotekanauki.pl/articles/1853630.pdf
Data publikacji:
2021
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
wieża telewizyjna
Stuttgart
pomiar GPS
odpowiedź dynamiczna
odpowiedź spowodowana wiatrem
częstotliwości drgań własnych
liczba tłumienia drgań
television tower
GPS measurement
wind-induced response
dynamic response
natural frequency
damping ratio
Opis:
This paper compares the measurement results of dynamic characteristics, including natural frequencies, damping ratio, and wind-induced responses of the Stuttgart TV Tower (TV Tower), obtained by Lenk in 1959 using classical instruments with those obtained by the authors a few decades later using Global Positioning System (GPS). The objective of this paper was to monitor the response of the TV Tower under wind loading, which is an important tool for the validation of its design, construction, and structural health. During the authors’ GPS measurements, weak and moderate wind speeds occurred most of the time. Only in 2007, the stronger wind observed (90 < V < 100 km/h) at the head of the TV Tower (H=157 m), which caused displacements in the decimetre range. Further measurements in 2011 were carried out, using additional GPS receivers with a higher data rate. The results achieved by the GPS prove that the cross-wind response was larger than the along-wind component for all ranges of wind speed, which occurred during the measurement periods, i.e. from 2002 to 2015. The authors of this paper extended Lenk’s results, by the static and along-wind components, confirmed the first natural frequency, and damping ratio, evaluated by the Random Decrement technique. Mounting a GPS receiver, on the steel antenna mast tip, enabled detection of the second natural frequency fs2 = 0.800 Hz, which is the frequency of the mode shape of the TV Tower steel antenna mast. Lenk did not measure this frequency.
Wieża telewizyjna w Stuttgarcie została oddana do użytkowania w dniu 5 lutego 1956 roku. Konstrukcja wieży składa się z dwóch części: (a) trzonu żelbetowego z głowicą o wysokości 161 m i (b) stalowego masztu antenowego o wysokości 56 m. Całkowita wysokość wieży to 217 m. Średnica zewnętrzna trzonu żelbetonowego wynosi 10,8 m u podstawy trzonu i 5,04 m w górnej części trzonu (poniżej głowicy trzonu). Grubość ściany trzonu zmienia się od 60 cm do 19 cm. W latach 1953-1954 Leonhard zaproponował koncepcję i projekt wieży telewizyjnej. Biuro projektowe Pieckert zaprojektowało system konstrukcyjny. Koncepcję wieży telewizyjnej, jej układ konstrukcyjny, wszystkie założenia do obliczeń statycznych, oszacowanie nakładów finansowych i pierwsze pomiary osiadań fundamentów podane zostały w jednej z prac Leonhardta. W tej pracy zasugerowano także potrzebę pomiaru odpowiedzi wieży telewizyjnej na działanie wiatru. Jako pierwszy dokonał tego Lenk w 1959 roku. W latach 1977 i 1995 stwierdzono pionowe pęknięcia w żelbetowym trzonie wieży, które następnie zostały naprawione. Przyczyny tych pęknięć wyjaśniono jako konsekwencje promieniowania słonecznego i dobowych zmian temperatury powietrza działających na trzon wieży telewizyjnej, wywołujących deformacje płaszcza trzonu. Naprężenia termiczne spowodowały zmienną w czasie „owalizację” trzonu wieży, która z biegiem lat doprowadziła do zmęczenia materiału, czego skutkiem były wyraźnie widoczne podłużne pęknięcia po przeciwnych stronach trzonu wieży telewizyjnej. Autorom niniejszego artykułu nie są znane wcześniejsze pomiary charakterystyk dynamicznych wieży telewizyjnej związane z naprawą powstałych pęknięć. W związku z tym, w 1999 roku autorzy przeprowadzili pierwszą serię pomiarów przemieszczeń wierzchołka wieży telewizyjnej z zastosowaniem techniki satelitarnej GPS. Metodologia pomiarów była podobna do metodologii stosowanej przez innych badaczy. Na tej podstawie autorzy potwierdzili możliwość zastosowania systemu GPS do monitorowania przemieszczeń statycznych, quasi-statycznych i dynamicznych oraz do określania podstawowych charakterystyk dynamicznych (częstotliwości drgań własnych i współczynników tłumienia drgań) istniejących dużych konstrukcji w skali naturalnej. Autorzy cyklicznie monitorowali przedmiotową wieżę telewizyjną do roku 2015. Jednak pomimo podjętego wysiłku w celu zebrania dodatkowych danych pomiarowych, niestety w 2013 i 2015 r. nie było możliwości pomiaru przemieszczeń wieży telewizyjnej pod wpływem silnego wiatru. Niemniej jednak autorzy dokonali analizy danych pomiarowych zgromadzonych w latach 2002, 2005, 2006, 2007, 2008 i 2011, które obejmowały pomiary w zakresie prędkości wiatru od małej do dużej. W dniach 18-19 stycznia 2007 r. w pobliżu wieży zarejestrowano porywy wiatru o prędkości 26 m/s, co spowodowało jej przemieszczenia w zakresie decymetrów.
Źródło:
Archives of Civil Engineering; 2021, 67, 1; 7-38
1230-2945
Pojawia się w:
Archives of Civil Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Effect Analysis of Loudspeaker’s Placement Angle and Direction on Frequency Response and Sound Pressure Level in TV Applications
Autorzy:
Demirel, Ibrahim
Powiązania:
https://bibliotekanauki.pl/articles/1953509.pdf
Data publikacji:
2021
Wydawca:
Polska Akademia Nauk. Czasopisma i Monografie PAN
Tematy:
acoustic transducers
frequency measurement
frequency response
loudspeakers
Opis:
In a television, obtaining a good acoustic response is a challenging issue because of slim mechanical structures. The area dedicated for speaker’s placement is limited and inadequate space inside the cabinet of a TV prevents possible solutions to increase the sound performance. In addition, frame of the TV’s is getting narrower as the customers searching for the highest screen to body ratio. These designing aspects restrain optimal speaker positioning to achieve good sound performance. In this paper, an analysis related to speaker’s placement and mounting angle is proposed. A rotation setup compatible with a TV was prepared to measure different facing position of the speaker. This paper proposes the analysis of speaker’s rotation and facing direction in a flat panel television and its effects on sound pressure level together with deviation of the acoustic response. Measurement results are analyzed with an audio analyzer together with a statistics tool to achieve precise results.
Źródło:
Archives of Acoustics; 2021, 46, 1; 79-85
0137-5075
Pojawia się w:
Archives of Acoustics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analysis of insulating parameters of oil transformer by time and frequency methods
Autorzy:
Gutten, Miroslav
Kucera, Matej
Brncal, Peter
Sebok, Milan
Korenciak, Daniel
Powiązania:
https://bibliotekanauki.pl/articles/327187.pdf
Data publikacji:
2020
Wydawca:
Polska Akademia Nauk. Polskie Towarzystwo Diagnostyki Technicznej PAN
Tematy:
insulating system
transformer
return voltage measurement
frequency dielectric spectroscopy
system izolacyjny
transformator
metoda spektroskopii częstotliwościowej
Opis:
In the paper is presented experimental analysis and diagnostics of insulating system oil-paper for power transformers. In the first part of the paper is described base theory about measurement and diagnostics insulating part (oil and paper) of transformers. In the other two parts of the paper is presented experimental results of the diagnostic measurement for the transformer 22/0.4 kV at constant temperature. Specifically, in the second part is described measuring time method of insulating diagnostics - return voltage measurement (RVM). This method is used for analysis of condition of paper moisture of high-voltage equipment. In the third part is described measuring method of insulating frequency diagnostics - frequency domain spectroscopy (FDS). This method is used for analysis insulating condition of high-voltage equipment with insulating oil-paper. The both measuring methods are unique in terms of analysis of insulating system of oil power transformers. In comparison with other methods, the RVM and FDS methods it is possible comparison and evaluate the moisture state of the dielectric paper of the power transformer with high reliability and accurate. Their reliability in determining moisture in paper was shown by determining the same result (3.5%) on the same measured transformer.
Źródło:
Diagnostyka; 2020, 21, 4; 51-56
1641-6414
2449-5220
Pojawia się w:
Diagnostyka
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Single parallel stubs as broadband microwave phase shifters
Autorzy:
Rutkowski, Adam
Powiązania:
https://bibliotekanauki.pl/articles/220484.pdf
Data publikacji:
2020
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
phase shift
differential phase shift
microwave phase shifter
parallel stub
instantaneous frequency measurement
IFM
Opis:
Structures and characteristics of wideband small-size phase shifters made with the use of single parallel stubs are presented in this paper. The stubs can be short-circuited or open-circuited on termination. Such devices are well known, but are primarily used as components of filters or matching circuits. The novelty, then, comes from the establishment of simple, but helpful formulae, which enable to describe the insertion phase shift and differential phase shift of a line with short and open stubs connected in parallel. These equations can be very useful for designing complex microwave multi-ports. The results of simulations and measurements of the devices, which were designed and made, are shown herein. It was also proved that the presented device shave several usable operating frequency sub-bands, and that the differential phase shift values in the higher sub-bands are greater than those in the lower operating frequency ranges. Thanks to this, the described phase shifters can be used in more than one frequency sub-band. It was stated that in the conditions under analysis, larger phase shifts can be achieved using open-circuited stubs rather than short-circuited stubs. However, the phase shifters with shorted parallel stubs can operate in a wider frequency band.
Źródło:
Metrology and Measurement Systems; 2020, 27, 1; 91-102
0860-8229
Pojawia się w:
Metrology and Measurement Systems
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The wavelet as the evaluation tool of vehicles’ seat suspension system
Autorzy:
Glowinski, Sebastian
Blazejewski, Andrzej
Powiązania:
https://bibliotekanauki.pl/articles/2146589.pdf
Data publikacji:
2020
Wydawca:
Politechnika Poznańska. Instytut Mechaniki Stosowanej
Tematy:
inertial measurement unit
frequency modulation
active seat suspension
multidimensional signal processing
inercyjny układ pomiarowy
modulacja częstotliwości
aktywne zawieszenie siedziska
wielowymiarowe przetwarzanie sygnałów
Opis:
In this paper, an innovative active seat suspension system for vehicles is presented. This seat suspension prototype is built with a shear guidance mechanism, an air spring, a hydraulic shock absorber and end-stop buffers. The acceleration particular signals are measured by using Inertial Measurement Units (IMUs) placed on the seat and the human head. As the excitation, the horizontal vibrations are applied. As an alternative to the classical Fourier approach, the Wavelet Transfer Function (WTF) is introduced to describe the effectiveness of particular seat suspension. In both of the system cases, the human head reaction is investigated by using the Matlab package.
Źródło:
Vibrations in Physical Systems; 2020, 31, 2; art. no. 2020206
0860-6897
Pojawia się w:
Vibrations in Physical Systems
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analysis of measurement conditions influence on the magnetic Barkhausen noise phenomenon
Analiza wpływu warunków pomiarowych na przebieg zjawiska magnetycznego szumu Barkhausena
Autorzy:
Maciusowicz, Michał
Psuj, Grzegorz
Powiązania:
https://bibliotekanauki.pl/articles/115155.pdf
Data publikacji:
2019
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
szum Barkhausena
metoda nieniszcząca
warunki pomiaru
analiza czasowo-częstotliwościowa
spektrogram
skalogram
Barkhausen noise
non-destructive method
measurement conditions
time-frequency analysis
spectrogram
scalogram
Opis:
The effectiveness of the magnetic Barkhausen noise method (MBN), used for non-destructive testing of ferromagnetic materials, depends to a large extent on a number of factors determining the measurement conditions. The use of conditions allowing the highest possible level of discrimination between the various states of the materials state is of highest importance. Therefore, this paper presents an analysis of the impact of measurement conditions on Barkhausen noise signals observed for various states of the material conditions. Taking into consideration the stochastic nature of MBN and the complex characterization of its changes, the analysis was based on the time-frequency representation of the MBN signal. The paper presents selected distributions achieved using two transformation methods. In addition, the extraction methods of features allowing the quantification of complex information were given. Finally, the discrimination ability for a number of parameters and features of MBN signals were determined and the obtained results were discussed.
Skuteczność metody magnetycznego szumu Barkhausena MBN (ang. Magnetic Barkhausen Noise), wykorzystywanej do badań nieniszczących materiałów ferromagnetycznych, zależy w dużej mierze od szeregu czynników określających warunki pomiarowe. Kluczowe znaczenie ma zastosowanie warunków umożliwiających najwyższy możliwy poziom dyskryminacji między różnymi stanami badanych materiałów. W związku z tym w niniejszej pracy przedstawiono analizę wpływu warunków pomiaru na sygnały szumu Barkhausena rejestrowane dla różnych stanów badanego materiału. Mając na uwadze stochastyczną naturę szumu MBN i złożoną charakterystykę jego zmian, analizę przeprowadzono na podstawie reprezentacji czasowo-częstotliwościowej sygnału MBN. W pracy zaprezentowano wybrane rozkłady z zastosowaniem dwóch metod transformacji. Ponadto przybliżono metody ekstrakcji cech umożliwiające kwantyfikację złożonej informacji. Na koniec określono poziomy rozróżnialności dla szeregu parametrów i cech sygnałów MBN oraz omówiono uzyskane wyniki.
Źródło:
Welding Technology Review; 2019, 91, 12; 17-24
0033-2364
2449-7959
Pojawia się w:
Welding Technology Review
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
DAQ-based measurements and study of supercapacitor frequency characteristics
Autorzy:
Sowa, Marcin
Jakubowska-Ciszek, Agnieszka
Powiązania:
https://bibliotekanauki.pl/articles/376459.pdf
Data publikacji:
2019
Wydawca:
Politechnika Poznańska. Wydawnictwo Politechniki Poznańskiej
Tematy:
supercapacitor
frequency characteristics
data acquisition device
measurement card
fractional derivative
Opis:
The paper concerns the beginning of a modeling study for supercapacitors. A data acquisition (DAQ) based system is presented, where an automated procedure has been implemented for the measurement of frequency characteristics. For a typical range of the supply voltage the characteristics are obtained. A model basing on fractional calculus is recalled and parameters for the model are obtained. The frequency characteristics of the model are compared with those obtained from measurements. Later the tested supercapacitor has its characteristics taken for various amplitudes and offsets of the source voltage. A few remarks are given for a possible expansion of the model when nonlinearity should be considered.
Źródło:
Poznan University of Technology Academic Journals. Electrical Engineering; 2019, 97; 203-213
1897-0737
Pojawia się w:
Poznan University of Technology Academic Journals. Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Evaluation of a high-precision digital multimeter by the laboratory of calibration of multifunction electrical instruments of INRIM
Autorzy:
Galliana, Flavio
Lanzillotti, Marco
Powiązania:
https://bibliotekanauki.pl/articles/220993.pdf
Data publikacji:
2019
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
digital multimeter
calibration
measurement uncertainties
low-frequency electrical measurements
performance index
measurement specifications
Opis:
A metrological verification of a high precision digital multimeter was made by the laboratory of calibration of programmable electrical multifunction instruments of the National Institute of Metrological Research (INRIM) in order to verify its accuracy and stability. The instrument had been tested for a period of six months for five low-frequency electrical quantities (DC and AC Voltage and Current and DC Resistance). Its stability and precision were compared with the accuracy specifications of the manufacturer. As a new approach, a performance index of the DMM was introduced and evaluated for each examined measurement point. The DMM showed a satisfactory agreement with its specifications to be considered at the level of other top-class DMMs and even better in some measurements points.
Źródło:
Metrology and Measurement Systems; 2019, 26, 2; 283-296
0860-8229
Pojawia się w:
Metrology and Measurement Systems
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Methods of DC/DC converter transfer function measurements, based on data acquired in the time domain
Autorzy:
Walczak, Marcin
Powiązania:
https://bibliotekanauki.pl/articles/220796.pdf
Data publikacji:
2019
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
DC–DC converters
frequency characteristics
transfer function measurement
Opis:
The measurement of frequency characteristics, like magnitude and phase, related to a specific transfer function of DC–DC converters, can be a difficult task - especially when the measured signal approaches the boundary of a small-signal model validity (i.e. 1/3 of the switching frequency fS ). It is hard to find a paper where authors mention the measurement techniques they use to draw frequency characteristics. Meanwhile the presence of noise in the output signal does not enable to directly measure the gain and the phase shift between the input and output signals. In such situations additional analysis is required in order to achieve a reliable result. This paper contains a description of a few methods that can be used to analyse measured signals in order to determine the gain and the phase shift of a specific transfer function. They enable to verify mathematical models in a wide range of frequencies (up to 1/3 fS ). The methods use signals measured in the time domain and can be implemented in mathematical software such as Matlab or Scilab.
Źródło:
Metrology and Measurement Systems; 2019, 26, 4; 661-671
0860-8229
Pojawia się w:
Metrology and Measurement Systems
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Adaptation of the power spectral density of a pseudorandom Gaussian noise to the real radio-frequency noise of the ISM band
Autorzy:
Nikonowicz, J.
Jessa, M.
Powiązania:
https://bibliotekanauki.pl/articles/114234.pdf
Data publikacji:
2018
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
radio-frequency noise measurement
ISM background noise
additive white Gaussian noise
pseudorandom noise adaptation
Opis:
Nowadays, simulation is a key part of the development and evaluation of every wireless system, while additive, white Gaussian noise (AWGN) is the basic noise model used in the created simulation models. Although the pseudorandom AWGN is the most common substitution of distortions used in the transmission models, it may differ significantly from the background noise recorded by the real radio receiver. In this paper authors present measurements of the real radio-frequency (RF) background noise of industrial, scientific and medical (ISM) band and analyze the differences between real and pseudorandom noise. The authors also propose polynomial adaptive equations that reduce the differences between pseudorandom and real RF noise power spectral densities. Using the given equations allows for better mapping of the real disturbances of the ISM band without the need for a prior noise measurements.
Źródło:
Measurement Automation Monitoring; 2018, 64, 2; 37-39
2450-2855
Pojawia się w:
Measurement Automation Monitoring
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Monitoring of phase jitter in fibre optic time and frequency transfer systems
Autorzy:
Salwik, K.
Śliwczyński, Ł.
Krehlik, P.
Powiązania:
https://bibliotekanauki.pl/articles/221405.pdf
Data publikacji:
2018
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
jitter measurement
phase comparison
fibre optics
time and frequency transfer
bidirectional
optical amplifier
Opis:
The phase jitter enables to assess quality of signals transmitted in a bi-directional, long-distance fibre optic link dedicated for dissemination of the time and frequency signals. In the paper, we are considering measurements of jitter using a phase detector the detected frequency signal and the reference signal are supplied to. To cover the wideband jitter spectrum the detected signal frequency is divided and - because of the aliasing process - higher spectral components are shifted down. We are also examining the influence of a residual jitter that occurs in the reference signal generated by filtering the jitter occurring in the same signal, whose phase fluctuations we intend to measure. Then, we are discussing the evaluation results, which were obtained by using the target fibre optic time and frequency transfer system.
Źródło:
Metrology and Measurement Systems; 2018, 25, 3; 487-497
0860-8229
Pojawia się w:
Metrology and Measurement Systems
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The amplitude-frequency measurement in non-destructive testing using the eddy current method
Autorzy:
Kondej, A.
Szczepański, A.
Powiązania:
https://bibliotekanauki.pl/articles/115065.pdf
Data publikacji:
2018
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
prąd wirowy
pomiar amplitudowo-częstotliwościowy
wykrywanie nieciągłości
badanie nieniszczące
eddy current
amplitude-frequency measurement
discontinuities detection
non-destructive testing
Opis:
The paper describes a miniaturized device that records changes in voltage amplitude and signal frequency. After applying the measuring probe to the surface of the tested material, the voltage and frequency amplitude changes. In a place free from defects and nonconformities values of voltage amplitude and frequency are taken as reference values, with which the results obtained during further tests are compared. A clear change in the value of any of the parameters indicates a change in the condition of the tested material. Registration of two parameters with different sensitivity for selected factors allows for a more accurate analysis of the condition of the tested material. The miniaturized device can works in manual measurement mode or in automatic mode, it can be used in defectoscopy, structure and thickness measurements.
Źródło:
Welding Technology Review; 2018, 90, 11; 12-15
0033-2364
2449-7959
Pojawia się w:
Welding Technology Review
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies