Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "frame structure" wg kryterium: Temat


Tytuł:
A Study on Packet Scheduling Algorithms for Healthcare Contents over Fifth Generation (5G) Mobile Cellular Network
Autorzy:
Ramli, Huda Adibah Mohd
Powiązania:
https://bibliotekanauki.pl/articles/1844466.pdf
Data publikacji:
2020
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
packet scheduling
5G
flexible frame structure
transmission reliability
scalable TTI
Opis:
This paper models the downlink Fifth Generation (5G) network that supports a flexible frame structure and a shorter Round-Trip Time (RTT) for Hybrid Automatic Repeat Request (HARQ). Moreover, the design of the renowned Time Division Multiple Access (TDMA) packet scheduling algorithms is revised to allow these algorithms to support packet scheduling in the downlink 5G. Simulation results demonstrate that the Proportional Fair provides a comparable performance to the delay–aware Maximum-Largest Weighted Delay First for simultaneously providing the desired transmission reliability of the Guaranteed Bit Rate (GBR) and Non-Guaranteed Bit Rate (Non - GBR) healthcare contents whilst maximizing the downlink 5G performance.
Źródło:
International Journal of Electronics and Telecommunications; 2020, 66, 4; 729-735
2300-1933
Pojawia się w:
International Journal of Electronics and Telecommunications
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Stability analysis of the single-layer dome in probabilistic description by the Monte Carlo method
Autorzy:
Zabojszcza, Paweł
Radoń, Urszula
Powiązania:
https://bibliotekanauki.pl/articles/1839641.pdf
Data publikacji:
2020
Wydawca:
Polskie Towarzystwo Mechaniki Teoretycznej i Stosowanej
Tematy:
stability
frame structure
single-layer domes
reliability index
Monte Carlo
method
Opis:
The paper shows the application of the Monte Carlo method to the stability analysis of a single-layer shallow (h/d = 0.04) dome modelled with frame elements. Structures of this type are characterized by strong nonlinearity, consequently, they are extremely susceptible to stability loss resulting from the node snap-through. It is necessary to perform a nonlinear stability analysis that allows determination of limit points related to that mode of stability failure. This paper shows that with the reliability analysis methods, it is possible to trace the failure probability level while moving along the load-displacement path towards the limit point.
Źródło:
Journal of Theoretical and Applied Mechanics; 2020, 58, 2; 425-436
1429-2955
Pojawia się w:
Journal of Theoretical and Applied Mechanics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Zagrożenia bezpieczeństwa konstrukcji wynikające z wymiany stropu w budynku szkieletowym
Construction safety risks resulting from the exchange of floor in the shell
Autorzy:
Ścigałło, J.
Powiązania:
https://bibliotekanauki.pl/articles/160985.pdf
Data publikacji:
2013
Wydawca:
Polski Związek Inżynierów i Techników Budownictwa
Tematy:
konstrukcja szkieletowa
strop
wymiana
bezpieczeństwo konstrukcji
frame structure
floor
exchange
construction safety
Opis:
Adaptacje istniejących budynków do spełniania nowych funkcji często wiążą się z koniecznością ingerencji w istniejący układ konstrukcyjny. Wielkość i zakres ingerencji wynikają z konieczności spełnienia nowych wymogów architektoniczno – funkcjonalnych, co często wiąże się z koniecznością przeniesienia nowych obciążeń zarówno co do ich wartości jak i charakteru działania. Modernizowane obiekty są często znacznie wyeksploatowane, a ich konstrukcja jest mocno zużyta. W pracy przedstawiono przypadek płyty stropowej 2 kondygnacji, która na znacznej swej powierzchni została zaolejona i wymagała naprawy.
Adaptations of existing buildings to meet the new features are often associated with the need to intervene in the structural system. The size and the scope of interference derive from the necessity to comply with the new architectural and functional requirements, which often involve the transfer of new charges, both as to the value and the nature of the action. Modernized facilities are often much more exploited, and their design is heavily worn. The study addresses a case of the floor slab of two storeys that on its large area were oiled up and needed repair.
Źródło:
Przegląd Budowlany; 2013, R. 84, nr 12, 12; 46-51
0033-2038
Pojawia się w:
Przegląd Budowlany
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Attenuation Characteristics of Vibration in a Locally Resonant Phononic Crystal Frame Structure
Autorzy:
Wang, Yukun
Qian, Denghui
Wu, Jinghong
He, Feiyang
Powiązania:
https://bibliotekanauki.pl/articles/176756.pdf
Data publikacji:
2020
Wydawca:
Polska Akademia Nauk. Czasopisma i Monografie PAN
Tematy:
LRPC frame structure
high-rise building
finite element method
vibration insulation
noise reduction
Opis:
In this paper, a frame structure based on the locally resonant (LR) mechanism of phononic crystals (PCs) is designed on account of the wide application of frame structures in high-rise buildings, and the band structures, displacement fields of eigenmodes, and transmission power spectrums of corresponding finite structure are calculated by finite element (FE) method. Numerical results and further analysis demonstrate that a full band gap with low starting frequency can be opened by the frame structure formed by periodically combining soft and hard materials, and the starting frequency can be further lowered with the adjustment of corresponding geometric parameters, which provides a theoretical basis for the studies on vibration insulation and noise reduction of high-rise buildings.
Źródło:
Archives of Acoustics; 2020, 45, 3; 557-562
0137-5075
Pojawia się w:
Archives of Acoustics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Deep data analysis in gigabit passive optical networks
Autorzy:
Horvath, T.
Krkos, R.
Dubravec, L.
Powiązania:
https://bibliotekanauki.pl/articles/174869.pdf
Data publikacji:
2017
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
GPONXpert
gigabit passive optical networks
GPON
signalling
user plane
frame structure
payload analysis
Opis:
This paper focuses on practical aspects of gigabit passive optical networks (GPON) diagnostics during deployment, for root-cause analysis and for research purposes. While GPON signalling analysis is already quite commonly used for diagnostics, the aim of this work is a holistic approach, including both signalling and user plane (payload) analysis. User plane analysis, especially if targeted at payload Ethernet, IP and transport layers, enables detection of additional group of problems that could limit or even prevent GPON internetworking and thus degrade the user perceived service quality. Integrated signalling and payload analysis is also interesting from the research point of view, leading to the ability to study equipment idiosyncrasies that would be hard to detect otherwise and it is also one of the enablers of equipment security verification. The mentioned theories were tested during a practical diagnostic session on a real GPON network deployment and this paper presents the findings.
Źródło:
Optica Applicata; 2017, 47, 1; 157-170
0078-5466
1899-7015
Pojawia się w:
Optica Applicata
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Application of buckling restrained braces to upgrade vertical stiffness of existing RC frames
Autorzy:
Niyonyungu, Ferdinand
Noroozinejad Farsangi, Ehsan
Powiązania:
https://bibliotekanauki.pl/articles/395995.pdf
Data publikacji:
2020
Wydawca:
Uniwersytet Zielonogórski. Oficyna Wydawnicza
Tematy:
frame structure
retrofitting
vertical stiffeners
restrained braces
nonlinear analysis
ramy żelbetowe
modernizacja
usztywnienie pionowe
klamry
analiza nieliniowa
Opis:
In this paper, based on the RC frame structure of an industrial building, the finite element model of the structure is developed, according to the Chinese code for seismic design of buildings [9]. Considering the lack of seismic performance, the buckling restrained brace (BRB) is adopted for seismic retrofitting, and various configurations of buckling restrained support are considered for reinforcement. The elastic response spectrum analysis (RSA) and direct integration nonlinear time history analyses (NL-TH) are carried out for the frame structure before and after reinforcement using ETABS finite element software. From the joints displacement, inter-story displacement, inter-story shear force, acceleration, energy dissipation, and other aspects of the seismic response of the strengthened structure and the non-strengthened structure, the comparison has been made. The effect of buckling restrained support and common support on the existing building structure is verified through analytical modeling. After reinforcement, there is a 40%, 39.3%, 40%, 36.4%, and 38.3% reduction in the first period of vibration after the building is strengthened by inverted BRB, V BRB, two-story BRB, single BRB, and ordinary steel braces, respectively. Strengthening of the structure by buckling restrained braces and ordinary steel braces both decrease the original building displacement by more than 50% from the first to the fourth floor. Under severe earthquakes, the use of BRB reduced the column shear by 46.6%; similarly, the incorporation of ordinary steel braces reduced the column shear by 4.72%. It is concluded that using buckling restrained braces will increase the vertical stiffness of the structure to a very high extent.
Źródło:
Civil and Environmental Engineering Reports; 2020, 30, 3; 68-93
2080-5187
2450-8594
Pojawia się w:
Civil and Environmental Engineering Reports
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Diagnostyka obiektu zabytkowego o konstrukcji zespolonej szkieletowej
Diagnostics of a historical building with a composite frame structure
Autorzy:
Nowogońska, B.
Powiązania:
https://bibliotekanauki.pl/articles/162305.pdf
Data publikacji:
2012
Wydawca:
Polski Związek Inżynierów i Techników Budownictwa
Tematy:
konstrukcja drewniana
kościół
Sękowice
konstrukcja szkieletowa zespolona
stan techniczny
korozja biologiczna
wood structure
church
composite frame structure
technical condition
biological corrosion
Opis:
Kościół w Sękowicach jest budowlą jednonawową wykonaną w technologii tradycyjnej szkieletowej. W konsekwencji zaniedbań działań konserwatorskich znaczna część elementów drewnianej konstrukcji uległa korozji biologicznej, przez co utraciła swoje pierwotne właściwości wytrzymałościowe. Część ścian osiadła na skorodowanych belkach podwalinowych, a nierównomierne osiadanie spowodowało skręcenie całej konstrukcji.
The church in Sękowice is a single-nave building with a traditional frame structure. As a consequence of conservation failures, a significant number of elements of the wooden structure have undergone biological corrosion, as a result of which their original strength properties have deteriorated. Some of the walls have subsided on the corroded ground beams, and uneven subsidence has caused the entire structure to become twisted.
Źródło:
Przegląd Budowlany; 2012, R. 83, nr 1, 1; 36-39
0033-2038
Pojawia się w:
Przegląd Budowlany
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Effective model for analysis of wood-framed timber structures
Efektywny model analizy szkieletowych konstrukcji drewnianych
Autorzy:
Malesza, J.
Powiązania:
https://bibliotekanauki.pl/articles/231344.pdf
Data publikacji:
2017
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
konstrukcja drewniana
konstrukcja szkieletowa
analiza numeryczna
materiał ortotropowy
metoda elementów skończonych
wood structure
frame structure
numerical analysis
orthotropic material
finite element method
Opis:
This paper presents new procedure modeling based on finite element method analysis of wood-framed timber structures. The fasteners linking boards of sheathing with the timber frame both modeled applying shell finite element, with individual material parameters, remain the main objective of this manuscript. Material parameters are obtained from experimental tests and numerical identification. The main objective of the paper is the elaboration of the numerical model with high precision of mapping, and, at the same time, diminishing the number of the unknown simplifying the process of the modeling of timber structures. The new presented method leads to a simplification of analysis of multistory wood-framed multifamily building structures.
W artykule przedstawiono nowy sposób modelowania szkieletowych konstrukcji drewnianych w oparciu o metodę elementów skończonych. Głównym zagadnieniem są łączniki szkieletu drewnianego z płytą poszycia, w opisie których przyjmuje się elementy powłokowe o szczególnych cechach materiałowych. Parametry materiałowe ustala się na podstawie prób materiałowych oraz identyfikacji numerycznej. Celem autora jest opracowanie modelu numerycznego o dużej dokładności odwzorowania przy jednoczesnym zmniejszeniu liczby niewiadomych i uproszczeniu procesu modelowania konstrukcji. W konsekwencji nowa metoda może ułatwić analizy budynków wielorodzinnych.
Źródło:
Archives of Civil Engineering; 2017, 63, 2; 99-112
1230-2945
Pojawia się w:
Archives of Civil Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Awaria drewnianej szkieletowej konstrukcji ścian basenu kąpielowego
Failure of skeleton timber structure of swimming pool walls
Autorzy:
Malczyk, A.
Brol, J.
Powiązania:
https://bibliotekanauki.pl/articles/161731.pdf
Data publikacji:
2010
Wydawca:
Polski Związek Inżynierów i Techników Budownictwa
Tematy:
basen kąpielowy
budynek basenu
szkielet drewniany
awaria
przyczyna uszkodzeń
swimming pool
swimming pool building
timber frame structure
failure
destruction causes
Opis:
W artykule przedstawiono opis konstrukcji parterowego budynku basenu kąpielowego wykonanego w technologii szkieletu drewnianego. W wyniku błędów projektowych i wykonawczych, po kilku latach użytkowania obiektu wystąpił stan awaryjny konstrukcji nośnej szkieletu spowodowany butwieniem drewna. Przedstawiono sposób wymiany uszkodzonych elementów oraz jego realizację.
Structure of one floor building of swimming pool realized as a skeleton made out of timber is presented. Failure of structure was a result of decay of wood after just few years of exploitation. Paper presents a realization of damage repair.
Źródło:
Przegląd Budowlany; 2010, R. 81, nr 7-8, 7-8; 50-53
0033-2038
Pojawia się w:
Przegląd Budowlany
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analiza wad projektowych i wykonawczych konstrukcji hali sportowej z drewna klejonego warstwowo
Design and erection faults analysis of sport halls glulam structure
Autorzy:
Nowak, T.
Raszczuk, K.
Jasieńko, J.
Powiązania:
https://bibliotekanauki.pl/articles/161570.pdf
Data publikacji:
2013
Wydawca:
Polski Związek Inżynierów i Techników Budownictwa
Tematy:
hala sportowa
konstrukcja ramowa
rama drewniana
drewno klejone warstwowo
jakość
stan techniczny
analiza statyczna
sport hall
frame structure
wooden frame
glued laminated timber
quality
technical condition
static study
Opis:
W pracy przedstawiono wyniki analiz, niewłaściwie zaprojektowanej i wykonanej, konstrukcji z drewna klejonego warstwowo hali sportowej. Skutkiem popełnionych błędów są spękania w każdym z węzłów konstrukcji drewnianej, a w konsekwencji wyłączenie jej z eksploatacji od 2006 roku. Przeprowadzone i opisane prace badawcze wskazują na niewłaściwie zaprojektowane połączenia oraz nieprawidłowe składowanie i montaż elementów drewnianych.
The paper presents the results of analysis of poorly designed and build the glued laminated timber frame structure of sport hall. The analysis is connected with capacity and stiffness of the elements and fasteners, as well.
Źródło:
Przegląd Budowlany; 2013, R. 84, nr 10, 10; 23-27
0033-2038
Pojawia się w:
Przegląd Budowlany
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies