Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "fracture angle" wg kryterium: Temat


Wyświetlanie 1-3 z 3
Tytuł:
Unidirectional Torsion Properties of Single Silk Fibre
Właściwości monowłókien jedwabnych przy jednokierunkowym skręcaniu
Autorzy:
Jiang, S.
Cao, G.
Cai, G.
Xu, W.
Li, W.
Wang, X.
Powiązania:
https://bibliotekanauki.pl/articles/232187.pdf
Data publikacji:
2016
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Biopolimerów i Włókien Chemicznych
Tematy:
unidirectional torsion
silk fibre
fracture angle
breaking cycle
SEM
XRD
skręcanie jednokierunkowe
włókno jedwabne
badania
Opis:
The unidirectional torsion properties of silk fibre were investigated on a purpose-built single fibre torsion tester. The torsional fracture angle and the number of cycles of torsion at breaking were recorded, and the effect of the gauge length and pretension together with the torsion speed on the torsion properties of single silk fibre was investigated in detail. Scanning electron microscopy (SEM), X-ray diffraction (XRD) analysis and a tensile tester were used to understand the morphology, structure and tensile properties of silk fibre after torsion deformation. SME photos show that silk fibre exhibits a ribbon-like profile after torsion, and fracture tends to occur at both ends of the silk fibre, where a larger number of twists can be observed. The crystallinity calculated from XRD spectra of silk fibre increases from 26.11% to 34.10% after torsion. The breaking stress and strain decreases slightly with an increase in the gauge length. The breaking cycle increases linearly with an increase in the gauge length, while the actual torsional fracture angle decreases gradually at the same time. The torsional fracture angle together with the breaking cycle decreases gradually as the pretension increases. The fracture angle together with the breaking cycle increases with an increase in the torsion speed. Understanding the unidirectional torsion properties of single silk fibre will benefit its further application in specific areas where the fibre will be subject to frequent torsion and deformation.
Badania przeprowadzono za pomocą specjalnie zbudowanego urządzenia do badania skrętu włókien. Badano kąt przełomu oraz ilość cykli doprowadzających do zerwania. Sprawdzano również wpływ długości próbki oraz wstępnego naprężenia. Oceniono wpływ długości próbki wstępnego naprężenia, szybkości skrętu na właściwości wytrzymałościowe włókien jedwabnych. Stosowano SEM, XRD dla określenia morfologii i struktury włókien. Stwierdzono, że włókna jedwabne po badaniu wykazują formę podobną do taśmy. Na podstawie XRD stwierdzono, że krystaliczność wzrasta od ok. 26% do 34% po skręceniu. Naprężenie zrywające i odkształcenia zmniejszają się lekko przy wzroście długości próbki.
Źródło:
Fibres & Textiles in Eastern Europe; 2016, 3 (117); 26-30
1230-3666
2300-7354
Pojawia się w:
Fibres & Textiles in Eastern Europe
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Finite element analysis of mini-plate stabilization of human mandible angle fracture – a comparative study
Autorzy:
Wądołowski, Piotr
Krzesiński, Grzegorz
Gutowski, Piotr
Powiązania:
https://bibliotekanauki.pl/articles/27324127.pdf
Data publikacji:
2020
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
finite element analysis
maxillofacial surgery
mandibular angle fracture
miniplate osteosynthesis
contact mechanics
analiza elementów skończonych
chirurgia szczękowo-twarzowa
złamanie kąta żuchwy
osteosynteza minipłytkowa
mechanika kontaktowa
Opis:
Purpose: The purpose of this study was to analyze three patterns of mandible angle fracture treatment by means of the finite element analysis. Methods: Investigation has been based on the mandible geometry reconstructed with use of hospitalized patient CT data. The KLS Martin mini-plates with corresponding screws were used to establish proper fracture stabilization. Models were run assuming isotropic and elasto-plastic material properties of connecting devices and cortical bone. The main masticatory muscles and artificial temporomandibular joint have been incorporated to assure mandible physiological movement. The gage loading has been applied in three different locations to cover wider range of possible mastication loading cases during daily routine. A different contact conditions have been applied to the fracture plane to simulate both load bearing and sharing behaviors. Prepared FEM models reflect the most frequently used surgery’s approaches to mandible angle fracture treatment. A specific nomenclature has been introduced to describe particular model. The tension plate, with one connecting mini-plate, two-point fixation and combined fixation, both using two mini-plates respectively. Results: Performed analysis allowed for a detailed estimation of the mini-plate connection response under the applied gauge loading. The equivalent stress within the mini-plates and surrounding cortical bone have been compared between all models. Regarding the fracture plane, the contact status and pressure have been considered. Conclusions: The combined fixation model, acting as a biplanar fastener system, presents the highest flexibility and connection efficiency.
Źródło:
Acta of Bioengineering and Biomechanics; 2020, 22, 3; 105--116
1509-409X
2450-6303
Pojawia się w:
Acta of Bioengineering and Biomechanics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Fatigue Behavior of MIG-Welded 7N01-T4 Aluminum Alloy with Different V-Groove Angles
Autorzy:
Ma, Zhongwei
Li, Qinghua
Ma, Lin
He, Zhaokun
Liang, Zhimin
Powiązania:
https://bibliotekanauki.pl/articles/351758.pdf
Data publikacji:
2019
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
7N01-T4 aluminum alloy
MIG welding
V-groove angle
fatigue
fracture
Opis:
7N01-T4 aluminum alloy was welded by metal inert gas welding and the influence of V-groove angle on joint fatigue properties was investigated. The results indicate that the volume of fusion zone (FZ) and the grains in FZ become small when the groove angle decreases to 50° from 70°. Most pores distribute at the FZ edge and fewer pores are formed in the small angle joint. The fatigue crack mainly initiates at the transition region between the weld passes due to the pore concentration. The small angle contributes to increasing joint fatigue properties, especially at the low stress level. The fatigue strength of 50° joint is 103.06 MPa which is 15.3% higher than that of 70° joint.
Źródło:
Archives of Metallurgy and Materials; 2019, 64, 4; 1577-1584
1733-3490
Pojawia się w:
Archives of Metallurgy and Materials
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-3 z 3

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies