Wyszukujesz frazę "focused intensity" wg kryterium: Temat


Wyświetlanie 1-5 z 5
Tytuł:
Experimental study of an anomalous hollow beam with orbital angular momentum
Autorzy:
Lu, Xingyuan
Zhao, Chengliang
Hoenders, Bernhard J.
Yang, Yuanjie
Cai, Yangjian
Powiązania:
https://bibliotekanauki.pl/articles/173518.pdf
Data publikacji:
2019
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
anomalous hollow beam
orbital angular momentum
focused intensity
Fourier transform
Opis:
Anomalous hollow beam has potential applications in the optical trapping and free space optical communications, etc. It is noted that, thus far, although a large number of studies have been carried out in this field, most of them are theoretical studies and only quite a few cases have experimental results. Here, we experimentally study the generating of anomalous hollow beam carrying orbital angular momentum, and measure its topological charge. We show that the number of dark rings in the Fourier transform of intensity patterns is equal to the topological charge. The experimental results agree well with the simulations.
Źródło:
Optica Applicata; 2019, 49, 2; 217-226
0078-5466
1899-7015
Pojawia się w:
Optica Applicata
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Automated bimodal ultrasound device for preclinical testing of HIFU technique in treatment of solid tumors implanted into small animals
Autorzy:
Kujawska, T.
Dera, W.
Dziekoński, C.
Powiązania:
https://bibliotekanauki.pl/articles/332489.pdf
Data publikacji:
2017
Wydawca:
Polskie Towarzystwo Akustyczne
Tematy:
High Intensity Focused Ultrasound beam
focal volume
tissue damage
Opis:
In Poland cancer is the second cause of death overall, and the first before 65. Demand for new anticancer therapies is increasing every year. The main objective of studies on medical and technical aspects of new anticancer methods is to reduce unwanted side effects and costs associated with conventional methods of treatment. Percutaneous (noninvasive) HIFU (High Intensity Focused Ultrasound) technique gives the chance to radically reduce both of these factors. The main goal of this work is automation of HIFU technology for producing thermal damage to the entire volume of a solid breast tumor implanted into a rat mammary gland using the proposed bi-modal ultrasound equipment, enabling the ultrasonic heating of a small volume within the tumor under the ultrasonic imaging control, as well as 3D scanning of the heating beam focus throughout the entire tumor volume. Design of the proposed equipment includes the heating probe of low frequency (about 1MHz), allowing penetration of pulsed focused waves into tissues, and the linear phased array probe of high frequency (from 4 MHz to 10 MHz), allowing visualization of the locally heated area inside the tumor in real time. Automatic 3D scanning of the heating beam focus provides the thermal damage to its entire volume.
Źródło:
Hydroacoustics; 2017, 20; 93-98
1642-1817
Pojawia się w:
Hydroacoustics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Ultradźwiękowa plastyka ciała rzęskowego w terapii jaskry opornej – obserwacje średnioterminowe
Ultrasound ciliary plasty in refractory glaucoma treatment – a medium-term follow-up study
Autorzy:
Bolek, Bartłomiej
Wylęgała, Edward
Powiązania:
https://bibliotekanauki.pl/articles/1927524.pdf
Data publikacji:
2020
Wydawca:
Medical Education
Tematy:
cyclodestruction
glaucoma
high-intensity focused ultrasound
intraocular pressure
ultrasound ciliary plasty
Opis:
Cel pracy: Ocena rocznej skuteczności i bezpieczeństwa zabiegu ultradźwiękowej plastyki ciała rzęskowego w jaskrze opornej. Materiał i metody: 57 pacjentów (37 K, 20 M, średnia wieku: 67,6 roku) z jaskrą pierwotną i wtórną otwartego kąta poddano zabiegowi. Kryteriami włączenia były: wiek powyżej 18. r.ż., niekontrolowana jaskra otwartego kąta (ciśnienie wewnątrzgałkowe > 21 mmHg), przeciwwskazania do zabiegu klasycznego, nietolerancja leków. Kryteriami wyłączenia były: ciąża, niepełnoletniość, ciśnienie wewnątrzgałkowe > 30 mmHg, jaskra zamykającego się kąta lub neowaskularna. Pełne badanie okulistyczne przeprowadzono przed zabiegiem oraz dzień, tydzień, miesiąc, 3 miesiące, 6 miesięcy i 12 miesięcy po zabiegu. Ciśnienie wewnątrzgałkowe badano za pomocą tonometrii aplanacyjnej Goldmanna. Za skuteczność leczenia przyjęto obniżenie ciśnienia wewnątrzgałkowego o 20% lub o ponad 5 mmHg w stosunku do pomiaru wyjściowego (sukces częściowy) oraz całkowite odstawienie leków przeciwjaskrowych (sukces całkowity). Wyniki: Średnia wartość ciśnienia wewnątrzgałkowego została obniżona o 26,9% na ostatniej wizycie w porównaniu z wartością sprzed operacji. Sukces częściowy uzyskano w przypadku 87,7% oczu, a sukces całkowity w przypadku 12,3% oczu. Średnia liczba leków przeciwjaskrowych wyniosła odpowiednio: 4,0 ± 0,9, 0,9 ± 1,1, 0,9 ± 1,1, 1,1 ± 1,1, 1,8 ± 1,4, 2,1 ± 1,4, 2,4 ± 1,4 (p < 0,001 dla wszystkich wartości). Średnia wartość najlepszej skorygowanej ostrości wzroku ± SD wyniosła odpowiednio: 0,37 ± 0,46, 0,47 ± 0,45 (p = 0,003), 0,46 ± 0,45 (p = 0,004), 0,31 ± 0,37 (p = 0,151), 0,36 ± 0,45 (p = 0,880), 0,39 ± 0,47 (p = 0,504). Nie odnotowano poważnych powikłań poza odłączeniem naczyniówki (5,3%) i obrzękiem plamki (3,5%). Wnioski: Ultradźwiękowa plastyka ciała rzęskowego jest metodą skuteczną i bezpieczną w obserwacji średnioterminowej. Dalsze badania na większej grupie powinny być prowadzone w dłuższym okresie obserwacji.
Objectives: To assess the efficacy and safety of ultrasound ciliary plasty (UCP) for treating refractory glaucoma during one year follow-up. Material and methods: A total of 57 patients (37 F, 20 M; mean age: 67.6 years) with primary and secondary refractory glaucoma were enrolled to undergo UCP. The inclusion criteria for the study were: ≥ 18 years, uncontrolled open-angle glaucoma (IOP > 21 mmHg), contraindication to incisional glaucoma surgery, intolerance to glaucoma medications despite well-controlled IOP. The exclusion criteria were: pregnancy, age < 18 years, IOP > 30 mmHg, angle-closure glaucoma and neovascular glaucoma. Complete ophthalmic examinations were performed preoperatively and as well as 1 week and 1, 3, 6, 12 months postoperatively. An IOP reduction of 20% or > 5 mmHg as compared to the baseline value was considered as successful treatment. Complete success was defined as cessation of antiglaucoma medications. Results: The mean IOP at the last follow-up was reduced by 26.9%. The success rate was 87.7% and the complete success rate was 12.3%. The mean ± SD values of the number of antiglaucoma medications were: 4.0 ± 0.9, 0.9 ± 1.1, 0.9 ± 1.1, 1.1 ± 1.1, 1.8 ± 1.4, 2.1 ± 1.4, 2.4 ± 1.4 (p < 0.001 for all values), respectively. The best-corrected logMAR visual acuities were: 0.37 ± 0.46, 0.47 ± 0.45 (p = 0.003), 0.46 ± 0.45 (p = 0.004), 0.31 ± 0.37 (p = 0.151), 0.36 ± 0.45 (p = 0.880), 0.39 ± 0.47 (p = 0.504), respectively. Following the procedure, choroid detachment was observed in three patients (5.3%) and macular in two patients (3.5%). No other major intraoperative or postoperative complications occurred. Conclusion: Ultrasound ciliary plasty is a safe and well-tolerated procedure in medium-term follow-up. Further studies with a larger group of patients and longer follow-up are needed to confirm these results.
Źródło:
OphthaTherapy; 2020, 7, 3; 246-254
2353-7175
2543-9987
Pojawia się w:
OphthaTherapy
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Noninvasive Imaging of Thermal Fields Induced in Soft Tissues In Vitro by Pulsed Focused Ultrasound Using Analysis of Echoes Displacement
Autorzy:
Karwat, P.
Litniewski, J.
Kujawska, T.
Secomski, W.
Krawczyk, K.
Powiązania:
https://bibliotekanauki.pl/articles/176451.pdf
Data publikacji:
2014
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
high intensity focused ultrasound
HIFU
therapeutic ultrasound
ultrasonic imaging
echo strain estimation
Opis:
Therapeutic and surgical applications of focused ultrasound require monitoring of local temperature rises induced inside tissues. From an economic and practical point of view ultrasonic imaging techniques seem to be the most suitable for the temperature control. This paper presents an implementation of the ultrasonic echoes displacement estimation technique for monitoring of local temperature rise in tissue during its heating by focused ultrasound The results of the estimation were compared to the temperature measured with thermocouple. The obtained results enable to evaluate the temperature fields induced in tissues by pulsed focused ultrasonic beams using non-invasive imaging ultrasound technique.
Źródło:
Archives of Acoustics; 2014, 39, 1; 139-144
0137-5075
Pojawia się w:
Archives of Acoustics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Design and Verification of Sector Vortex Archimedean Spiral Phased Array Transducer for Improving Focus Acoustic Pressure
Autorzy:
Lu, Xiaodan
Zeng, Deping
Powiązania:
https://bibliotekanauki.pl/articles/31339756.pdf
Data publikacji:
2024
Wydawca:
Polska Akademia Nauk. Czasopisma i Monografie PAN
Tematy:
phased array transducer
Archimedean spiral
high-intensity focused ultrasound
HIFU
focal deflection
Opis:
The emergence of high-intensity focused ultrasound applications brings great potential to establish noninvasive therapeutic treatment in place of conventional surgery. However, the development of ultrasonic technology also poses challenges to the design and manufacture of high-power ultrasound transducers with sufficient acoustic pressure. Here, the design of a sector vortex Archimedean spiral phased array transducer that is able to enhance focal acoustic pressure is proposed by maximizing the filling factor of the piezoelectric array. The transducer design was experimentally verified by hydrophone measurements and matched well with acoustic simulation studies. The focal deflection was shown to be feasible up to ±9 mm laterally and up to ±20 mm axially, where the effective focal acoustic pressure can be maintained above 50% and the level of the grating lobe below 30%. Furthermore, a homogeneous pressure distribution without secondary focus was observed in the pre-focal region of the transducer. The rational design of a high-intensity focused ultrasound transducer indicates promising development in the treatment of deep tissue thermal ablation for clinical applications.
Źródło:
Archives of Acoustics; 2024, 49, 1; 73-81
0137-5075
Pojawia się w:
Archives of Acoustics
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-5 z 5

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies