Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "flowmeter" wg kryterium: Temat


Tytuł:
Evaluating the uncertainty of the amount of thermal energy for metering systems with differential pressure flowmeters
Szacowanie niepewności ilości energii cieplnej w układach pomiarowych z przepływomierzami zwężkowymi
Autorzy:
Byts, Oksana
Kurytnik, Igor
Matiko, Fedir
Lesovoy, Leonid
Matiko, Halyna
Powiązania:
https://bibliotekanauki.pl/articles/303750.pdf
Data publikacji:
2020
Wydawca:
Wydawnictwo Druk-Art
Tematy:
niepewność wyniku pomiaru
ilość energii cieplnej
przepływ nośnika ciepła
entalpia
przepływomierz zwężkowy
uncertainty of the measurement result
amount of thermal energy
flowrate of heat carrier
enthalpy
differential pressure flowmeter
Opis:
In commercial metering systems of thermal energy it is important to obtain not only the measured value of the amount of thermal energy, but also the characteristic of the uncertainty of this value. The paper presents the developed technique for evaluating the uncertainty of the measurement result of the amount of thermal energy for metering systems with differential pressure flowmeters used for metering the heat carrier flowrate. The technique uses the dependencies developed by the authors for calculating the relative standard uncertainty of the amount of thermal energy, enthalpy and flowrate of heat carrier. The equation for calculating the uncertainty of heat carrier enthalpy was developed by applying the dependencies of the technique IAPWS IF 97. The approaches proposed by the authors make it possible to develop dependencies for evaluating the uncertainty of the measurement result of the amount of thermal energy for systems of different configurations and systems with different types of flowmeters.
Dla systemów komercyjnego rozliczania energii cieplnej ważne jest uzyskanie nie tylko zmierzonej ilości energii cieplnej, ale również charakterystyki niepewności tej ilości. W artykule opracowano technikę oceny niepewności wyniku pomiaru energii cieplnej dla systemów pomiarowych, w których do pomiaru przepływu nośnika ciepła stosowane są przepływomierze zwężkowe. Opracowana technika polega na wykorzystaniu opracowanych przez autorów zależności do obliczenia względnej standardowej niepewności ilości energii cieplnej, entalpii i przepływu nośnika ciepła. Zależność do obliczania niepewności entalpii nośnika ciepła opracowano przy użyciu zależności metody IAPWS IF 97. Podejścia zaproponowane przez autorów umożliwiają opracowanie zależności do szacowania niepewności zmierzonej wartości ilości energii cieplnej dla układów o różnej konfiguracji, a także układów wykorzystujących przepływomierze różnych typów.
Źródło:
Napędy i Sterowanie; 2020, 22, 4; 57-63
1507-7764
Pojawia się w:
Napędy i Sterowanie
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Experimental and numerical investigation of thermal flow meter
Autorzy:
Cebula, A.
Powiązania:
https://bibliotekanauki.pl/articles/240345.pdf
Data publikacji:
2015
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
mass flowmeter
heat transfer
uniform heat flux
thermal model
miernik przepływu
wymiana ciepła
model termiczny
Opis:
The paper presents analytical and numerical model calculation results of the temperature distribution along the thermal flow meter. Results show a very good conformity between numerical and analytical model. Apart from the calculation results the experimental investigations are presented. The author performed the test where a temperature of duct wall surface was measured. Therelation between mass flow rate in terms of the duct surface temperature difference was developed.
Źródło:
Archives of Thermodynamics; 2015, 36, 3; 149-160
1231-0956
2083-6023
Pojawia się w:
Archives of Thermodynamics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analiza wpływu gęstości siatki numerycznej na wyniki symulacji ścieżki wirowej von Karmana
Analysis of influence of numerical mesh density on results of simulation of von Karman vortex street
Autorzy:
Czapla, B.
Rząsa, M.
Powiązania:
https://bibliotekanauki.pl/articles/408337.pdf
Data publikacji:
2017
Wydawca:
Politechnika Lubelska. Wydawnictwo Politechniki Lubelskiej
Tematy:
przepływomierz wirowy
numeryczna mechanika płynów
model turbulencji
siatka obliczeniowa
vortex flowmeter
CFD
turbulent model
computational mesh
Opis:
Praca zawiera badania numeryczne polegające na symulacji ścieżki wirowej von Karmana. Znajomość ścieżki wirowej stanowi istotne zagadnienie w projektowaniu przepływomierzy typu vortex. Jednym z istotnych elementów w symulacji numerycznej jest odpowiednia siatka obliczeniowa. W pracy przedstawiono wyniki numerycznej analizy wpływu gęstości siatki na wyniki symulacji. W obliczeniach numerycznych duży wpływ na poprawność wyników ma właściwe przygotowanie modelu do obliczeń pod względem doboru gęstości siatki. Wykazano, że gęstość siatki wpływa na jakość otrzymanych wyników. Jednak istnieje optymalna liczba elementów siatki, dla której dalsze zwiększanie jej elementów nie poprawia znacząco wyników symulacji. W pracy przedstawiono optymalne wartości liczbowe dla przykładowego generatora wirów.
The paper includes numerical studies of simulating the von Karman vortex street. Knowledge of the vortex street is an important consideration in the design of vortex flowmeters. One of the important elements of the numerical simulation is suitable computational mesh. The paper presents the results of numerical analysis of the effect of mesh density on the simulation result. In numerical calculations a big impact on the correctness of results has the right to prepare a model for the calculation in terms of choice of mesh density. It has been shown that the density of the mesh affects the quality of the results. However be optimum number of elements of mesh, for which further increasing of its elements does not significantly improve results of simulation. In the paper presents the optimal numerical values for the exemplary vortex generator.
Źródło:
Informatyka, Automatyka, Pomiary w Gospodarce i Ochronie Środowiska; 2017, 7, 2; 66-69
2083-0157
2391-6761
Pojawia się w:
Informatyka, Automatyka, Pomiary w Gospodarce i Ochronie Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Numeryczna analiza wpływu zmiany kształtu generatora wirów na parametry przepływomierza wirowego
Numerical analysis of the effects of changes of bluff body shape on the parameters of the flowmeter
Autorzy:
Czapla-Niełacna, B.
Rząsa, M.
Powiązania:
https://bibliotekanauki.pl/articles/266681.pdf
Data publikacji:
2017
Wydawca:
Politechnika Gdańska. Wydział Elektrotechniki i Automatyki
Tematy:
przepływomierz wirowy
generator wirów
vortex flowmeter
von Karman vortex street
Opis:
W pracy przedstawiono analizę numeryczną wpływu kształtu generatora wirów na podstawowe parametry przepływomierza wirowego. Zalicza się do nich częstotliwość generowanych wirów, wartość sygnału mierzonego oraz regularność zmian częstotliwości generowanych wirów. Wydłużenie profilu generatora wirów lub wprowadzenie elementów zakłócających opływ w postaci szczeliny powoduje zmianę charakterystyki przepływomierza, oraz ma wpływ na stabilność ścieżki wirowej.
A lot of profiles of bluff bodies are currently commercially available. However, a universal form of the bluff body has not still been achieved to this time. Hence the study of the influence of the shape of the bluff body on the parameters of the flow meter is a current one. The work is concerned with the numerical analysis of the impact of selected surfaces of bluff body on selected parameters of the vortex flowmeter. In order to determine the effect of the shape of vortex shedder on the type of generated vortices, simulations were carried out for different flow velocities, i.e. 0.5m/s, 1m/s, 2m/s. The equations forming the mathematical model were solved by finite volume method using ANSYS Fluent. Turbulence k-_ SST model was applied for numerical calculations. Computations were performed for the assumption that at the inlet channel had a uniform distribution of the speed. The use of elongation or flow disturbing elements around in the form of a gap resulted in either the change in the characteristics of the flow meter, and reduction of its sensitivity in the lower measuring range. Such a modification may be beneficial to the vortex flowmeters with significant flow rates of liquid.
Źródło:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej; 2017, 54; 21-24
1425-5766
2353-1290
Pojawia się w:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analiza problemów pomiarów ciepła z wykorzystaniem hydrodynamicznego przepływomierza z wbudowanym rezystancyjnym czujnikiem temperatury
Analysis of problems of heat energy measurements with use of hydrodynamic flow-meters with embedded resistance temperature sensor
Autorzy:
Dorozhovets, M.
Kulyk, O.
Powiązania:
https://bibliotekanauki.pl/articles/152153.pdf
Data publikacji:
2012
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
pomiary
ciepło
przepływomierz
czujnik temperatury
measurement
heat energy
flowmeter
temperature sensor
Opis:
Autorzy na podstawie analizy typowego układu pomiaru ilości ciepła wykazali, że ma on kilka wad, m.in. nieuwzględnienie możliwej zmiany przepływu masowego z powodu straty technologicznej cieczy lub jej nieuprawnionego odbioru oraz wpływu zmiany charakterystyk cieplnych cieczy ze zmianą temperatury. W udoskonalonym układzie pomiaru ilości ciepła wykorzystuje się dwa przepływomierze (na wejściu i wyjściu), co pozwala uwzględnić stratę masowego przypływu cieczy.
The authors consider typical systems for heat energy measurements (Fig. 1). It is assumed that the liquid mass flow input and output are the same in a typical system. If there are technological losses of heat liquid or its stealing in a heating system, the output amount of liquid is less than the input amount. Then the methodical measurement error of the heat energy (formula (2)) appears. Another component of the measurement error is due to the influence of temperature on the heat capacity of liquid which is different at the input and output of the heating system (formula (3)). To eliminate the above-mentioned methodological errors, the heat energy must be measured at the input and output of the heating system (formula (5)). For this purpose there was proposed an improved system for measuring the amount of heat (Fig. 3). In this system there are used two flow-meters (input and output), which allows taking into account possible losses in the heating liquid. Hence, the relationship between the temperature of the liquid heat capacity (also at the input and output) (Fig. 3) is taken into consideration, too. In order to increase the accuracy of determining the heat by measuring the amount of the liquid movement and its temperature at the same point (which eliminates the appropriate component of the systematic measurement error), the authors developed a hydrodynamic flow-meter with a built-in resistance temperature sensor (Fig. 4). The instrumental component of the error of measuring the heat quantity (which is caused by use of two flow meters instead of one) was examined (formulas (6, 7)).
Źródło:
Pomiary Automatyka Kontrola; 2012, R. 58, nr 11, 11; 1000-1002
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Ultrasonic flow measurement with high resolution
Autorzy:
Grzelak, S.
Czoków, J.
Kowalski, M.
Zieliński, M.
Powiązania:
https://bibliotekanauki.pl/articles/221448.pdf
Data publikacji:
2014
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
ultrasonic flowmeter
time-to-digital converter
programmable logic device
time measurement
Opis:
The ultrasonic flowmeter which is described in this paper, measures the transit of time of an ultrasonic pulse. This device consists of two ultrasonic transducers and a high resolution time interval measurement module. An ultrasonic transducer emits a characteristic wave packet (transmit mode). When the transducer is in receive mode, a characteristic wave packet is formed and it is connected to the time interval measurement module inputs. The time interval measurement module allows registration of transit time differences of a few pulses in the packet. In practice, during a single measuring cycle a few time-stamps are registered. Moreover, the measurement process is also synchronous and, by applying the statistics, the time interval measurement uncertainty improves even in a single measurement. In this article, besides a detailed discussion on the principle of operation of the ultrasonic flowmeter implemented in the FPGA structure, also the test results are presented and discussed.
Źródło:
Metrology and Measurement Systems; 2014, 21, 2; 305-316
0860-8229
Pojawia się w:
Metrology and Measurement Systems
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Period verification device for ventilation rate standard rods based on a digital thermal flowmeter
Autorzy:
Hu, Jiacheng
Sha, Ying
Cai, Jinhui
Liu, Ying
Liu, Suijun
Powiązania:
https://bibliotekanauki.pl/articles/2052108.pdf
Data publikacji:
2022
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
ventilation rate standard rod
period verification
numerical simulation
digital thermal flowmeter
micro-pressure difference adjustment
Opis:
Ventilation rate is a physical index that is strictly controlled during cigarette manufacturing because an abnormal ventilation rate can affect the release of mainstream smoke, tar, and other components harmful to human health. Therefore, the standard rod is used for measuring the ventilation rate, which necessitates accurate and effective periodic inspections. In this study, we designed and built a set of special tobacco ventilation rate standard rods to assess the standard device during its verification period and used a digital thermal flowmeter as the flow standard.We determined the micro-pressure adjustment interval through fluid simulation, and conducted an experimental verification based on the simulation results. At the adjustment point where the differential pressure value was 0 Pa, the period verification device was tested under the standard values of 27.38%, 58.83%, and 71.95%. The results show that the measurement errors of the device are -0.42%, 0.55%, and -0.13% respectively, which all meet the verification regulation requirements and indicate that the device is applicable in practical situations.
Źródło:
Metrology and Measurement Systems; 2022, 29, 1; 231-244
0860-8229
Pojawia się w:
Metrology and Measurement Systems
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Experimental research on velocity profiles in selected flow systems
Autorzy:
Kabaciński, M.
Powiązania:
https://bibliotekanauki.pl/articles/1933977.pdf
Data publikacji:
2012
Wydawca:
Politechnika Gdańska
Tematy:
velocity profiles
air flow measurement
closed conduits
automated test stand
differential pressure flowmeter
Opis:
A problem of measuring of velocity profiles with the use of a fully automated test stand is presented in this paper. Due to the installed measurement equipment and various software alternatives it is possible to assess the inlet effect and distribution of velocities in the vicinity of averaging Pitot tubes in order to determine the phenomena occurring in their vicinity (recirculation, main stream direction) and verify the numerical models of turbulence. Due to the stream recirculation in the vicinity of the probes tested in a wind tunnel, a two-way probe was used instead of a Pitot tube. A linear module with a stepper motor formed an integral part of the measurement system whereby it was possible to determine the position of the measurement probe with a precision of 0.1mm. The measuring anemometer location, the possibility of adjusting the stream mean velocities and data acquisition were established by means of an original program. As far as the research in pipelines is concerned - the resulting characteristics allow the uncertainty of measurement to be precisely determined, which should be accounted for during the determination of air fluxes at locations which are not included in the technical documentation of a flowmeter.
Źródło:
TASK Quarterly. Scientific Bulletin of Academic Computer Centre in Gdansk; 2012, 16, 3-4; 185-201
1428-6394
Pojawia się w:
TASK Quarterly. Scientific Bulletin of Academic Computer Centre in Gdansk
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Fully Automated System for Air Velocity Profile Measurement
Automatyczny system do wyznaczania profilu prędkości dla strumienia powietrza
Autorzy:
Kabaciński, M.
Pawliczek, R.
Powiązania:
https://bibliotekanauki.pl/articles/139559.pdf
Data publikacji:
2012
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
air flux measurement
flowmeter
stepper engine drive
virtual instruments
pomiar przepływu powietrza
miernik przepływu
napęd silnika krokowego
przyrządy wirtualne
Opis:
The paper presents the idea of a system for controlling the movement of a flowmeter for air velocity profile measurement. In such a system, due to massive amount of data and limitations of the Data Acquisition Equipment, it is necessary to use moveable sensors. The flowmeter sensor is moved with the use of a linear module with a stepper motor and a tooth-belt drive. The location and speed of the sensor are controlled by a program based on the idea of virtual instrument. The proposed structure allows the user to control operation of the stand and provides automatic measurement. A wide range of velocity and step increments of the stepper motor drive, and flexibility of the virtual instrument software, allow one to create effective measurement systems ensuring sufficiently precise location with optimal time duration of measurement. It is shown that the linear module with tooth-belt is an effective alternative for similar modules with micro-screw drives.
W artykule zaprezentowano system kontroli przemieszczenia przyrządu do pomiaru profilu prędkości strumienia powietrza. W takich systemach z powodu dużej liczby punktów pomiarowych oraz ograniczeń wynikających z urządzeń do akwizycji danych konieczne jest przemieszczanie elementu pomiarowego. Czujnik przepływu jest przesuwany za pomocą modułu liniowego z napędem w postaci paska zębatego i silnika krokowego. Położenie i prędkość czujnika jest kontrolowane za pomocą autorskiego oprogramowania bazującego na idei tzw. „przyrządów wirtualnych”. Układ kontolno-pomiarowy pozwala operatorowi na obsługę stanowiska oraz automatyczne przeprowadzenie pomiarów. Szeroki zakres prędkości obrotowej i dużej rozdzielczości napędu w postaci silnika krokowego oraz elastyczność oprogramowania pozwala tworzyć efektywny system pomiarowy zapewniający dostatecznie dokładną lokalizację punktów pomiarowych przy optymalnym czasie pomiarów. Wykazano, ze napęd liniowy z zastosowaniem paska zębatego i silnika krokowego może być efektywną alternatywą dla podobnych urządzeń ze śruba napędową.
Źródło:
Archive of Mechanical Engineering; 2012, LIX, 4; 435-451
0004-0738
Pojawia się w:
Archive of Mechanical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Numerical analysis of flow averaging tubes in the vortex-shredding regime
Numeryczna analiza drgań czujników uśredniających ciśnienie dynamiczne
Autorzy:
Kabaciński, M.
Lachowicz, C. T.
Pospolita, J.
Powiązania:
https://bibliotekanauki.pl/articles/139634.pdf
Data publikacji:
2013
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
computational fluid dynamics (CFD)
numerical analysis of vibration
averaging Pitot tubes
flowmeter
obliczeniowa dynamika płynów
analiza numeryczna wibracji
rurki uśredniające Pitota
przepływomierz
Opis:
This paper presents a study on flowmeters oscillatory motion when subjected to periodical, enforced vibrations induced by vortex-shedding. The proposed mathematical modelling of flow was compared to corresponding numerical simulation, in form of modal analysis. The frequencies of vortices generation and detachment were calculated for a number of flow velocities in two different flowmeter profile variants. The performed modal evaluation enabled estimating their natural frequencies, and in consequence the acquired data helped us to determine flow velocity for which the analyzed structures were prone to resonant vibrations.
W artykule zaprezentowano proces oddziaływania wymuszonych przepływem płynu wirów na drgania przepływomierzy spiętrzających. Zaproponowany model matematyczny przepływu porównano z wynikami symulacji numerycznych w formie analizy modalnej. Częstotliwość generowania i odrywania się wirów policzono dla różnych predkości przepływu dla czujnika jedno- i dwuprofilowego. Przeprowadzone analizy modalne umożliwiły wyznaczenie ich częstotliwości, a w rezultacie pomogły w wyznaczeniu prędkości przepływu, dla których analizowany czujnik podatny jest na zjawisko rezonansu.
Źródło:
Archive of Mechanical Engineering; 2013, LX, 2; 283-297
0004-0738
Pojawia się w:
Archive of Mechanical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analiza numeryczna i eksperymentalna przepływomierza kolanowego
Numerical and experimental investigation of knee-shaped flow meter
Autorzy:
Kłosowiak, R.
Nygard, A.
Judt, W.
Powiązania:
https://bibliotekanauki.pl/articles/317166.pdf
Data publikacji:
2017
Wydawca:
Instytut Naukowo-Wydawniczy "SPATIUM"
Tematy:
przepływomierz kolanowy
analiza numeryczna
analiza eksperymentalna
knee flowmeter
numerical analysis
experimental analysis
Opis:
Elementem pomiarowym przepływomierza jest kolano rurowe, które znajduje się w praktycznie każdej instalacji przemysłowej. Kolano, jako element już istniejący w instalacji, nie wprowadza dodatkowych strat ciśnienia. Metoda ta choć mało popularna stanowi często jedyną możliwość pomiaru strumienia cieczy. Celem niniejszej pracy jest sprawdzenie możliwości i dokładności wyznaczenia charakterystyki przepływomierza kolanowego bez przeprowadzania kalibracji na obiekcie rzeczywistym. Praca obejmuje wyznaczenia charakterystyki rzeczywistego kolana segmentowego w oparciu o badania modelu laboratoryjnego i obliczenia numeryczne CFD.
The measuring element of the flowmeter is a tubular bend which can be found in practically every industrial installation. Tubular bend, as an element already existing in the installation, does not bring additional pressure losses. This method, although not popular, is often the only way to measure the liquid stream flow. The purpose of this paper is to check the ability and accuracy of characteristic designation for the knee-shaped flow meter without calibration on a real object. Article includes the determination of the actual segmental tubular bend characteristics based on laboratory model and numerical CFD calculations.
Źródło:
Autobusy : technika, eksploatacja, systemy transportowe; 2017, 18, 12; 962-966, CD
1509-5878
2450-7725
Pojawia się w:
Autobusy : technika, eksploatacja, systemy transportowe
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Effect of flow pulsations on the accuracy of differential pressure flowmeters
Autorzy:
Kostyk, I.
Matiko, F.
Fedoryshyn, R.
Powiązania:
https://bibliotekanauki.pl/articles/115923.pdf
Data publikacji:
2017
Wydawca:
Fundacja na Rzecz Młodych Naukowców
Tematy:
flow
pulsations
impulse line
resonance
error
differential pressure flowmeter
przepływ
pulsacje
linia impulsu
rezonans
błąd
przepływomierz różnicowy
Opis:
This work deals with investigation of influence of flow pulsation on the accuracy of gas flow rate and volume measurement by means of the differential pressure flow meters. Experimental studies of the step response curves of an impulse line with a pressure transducer (PT) were carried out with application of a high-frequency analog-to-digital converter of the pressure signal in the PT chamber. Mathematical model of an impulse line with a PT was built. This model provides simulation and investigation of the transient processes with high accuracy. The influence of the impulse line design (length, diameter) on the step response curves and on the frequency response curves as well as on the resonant frequency of the oscillating system (an impulse line with a PT chamber) was studied. The systematic errors of flow rate and volume measurement due to the resonance in the impulse lines which was caused by flow pulsation were simulated and studied for an acting differential pressure natural gas metering system. On the basis of the calculation results it was defined that amplification of the amplitude of the oscillating signal of the differential pressure due to the resonance may lead to a negative systematic error of gas volume measurement. The systematic errors of gas flow rate and volume measurement caused by the flow pulsation can be reduced by choosing the correct design of the impulse lines in order to avoid the resonance.
Źródło:
Challenges of Modern Technology; 2017, 8, 1; 23-31
2082-2863
2353-4419
Pojawia się w:
Challenges of Modern Technology
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Eksperymentalne określenie miejscowych strat ciśnienia w przepływomierzach kolanowych
Experimental defining of localised pressure loss in the studied elbow flowmeters
Autorzy:
Mrowiec, A.
Powiązania:
https://bibliotekanauki.pl/articles/269807.pdf
Data publikacji:
2013
Wydawca:
Wrocławska Rada Federacji Stowarzyszeń Naukowo-Technicznych
Tematy:
straty
przepływ turbulentny
przepływomierz kolanowy
pomiary
loss
turbulent liquid flow
elbow flowmeter
measurements
Opis:
W artykule przedstawiono wyniki badań doświadczalnych, pozwalające na wyznaczenie zastępczego współczynnika oporów miejscowych dla przepływomierzy kolanowych w funkcji średniego względnego promienia gięcia R/d przy przepływie turbulentnym cieczy w zakresie 5000<Re< 30000. Przpływomierze kolanowe wykonane są z kalibrowanych rur stalowych i stosowane w instalacjach zasilania paliwem lotniczych silników odrzutowych. Uzyskane w trakcie badań eksperymentalnych wartości współczynników strat miejscowych, różnią się od wartości podawanych w literaturze przedmiotu, co wskazuje na potrzebę przeprowadzenia dalszych badań.
The article presented the results of experimental research which allow to assign the vicarious local resistance ratio for the studied elbow flowmeters, made of calibrated pipes used in the fuel powered installations of aircraft jet engines, in the function of average relative bend radius R/d at turbulent liquid flow, at Reynolds namber 5000<Re< 30000. The experimental values of the coefficients losses local are different from the values given in the literature what are indicating on the need of conducting further research.
Źródło:
Inżynieria Maszyn; 2013, R. 18, z. 3; 79-87
1426-708X
Pojawia się w:
Inżynieria Maszyn
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Przepływomierz zwężkowy do pomiaru strumienia objętości oleju hydraulicznego
Constriction flow-meter for the measurements of volumetric flow rate of hydraulic oil
Autorzy:
Mrowiec, Andrzej
Powiązania:
https://bibliotekanauki.pl/articles/266639.pdf
Data publikacji:
2019
Wydawca:
Politechnika Gdańska. Wydział Elektrotechniki i Automatyki
Tematy:
przepływomierz zwężkowy
kryza z wlotem stożkowym
współczynnik przepływu
constriction flowmeter
flange with a conical inlet
flow coefficient
Opis:
W artykule przedstawiono zaprojektowany i wykonany kompaktowy przepływomierz z kryzą (mikrokryzą) z wlotem stożkowym. Przepływomierz ten będzie służył do pomiaru strumienia objętości przy niewielkich wartościach liczby Reynoldsa. Badania za pomocą tego przepływomierza przeprowadzono w obszarze przepływu laminarnego dla strumienia oleju hydraulicznego o lepkości kinematycznej 16,4 … 42,7 mm2/s. Wyniki wzorcowania przedstawiono w postaci wykresów charakterystyk przepływowych qv = f(Δp) i wyznaczonej uśrednionej wartości współczynnika przepływu równej C = 0,895 w zakresie liczb Reynoldsa ReD od 100 do 1000.
Designed and built compact constriction flow-meter based on flange (micro flange) with a conical inlet having contraction coefficient β = 0,47 for the measurement of volumetric flow rate with low values of Reynolds number was presented in this article. The experiments were conducted on the hydraulic flow site measuring volumetric flow rate with temperature of flowing oil. The measurements were taken in the area of laminar flow for the stream of hydraulic oil, whose kinematic viscosity was changing in the range 16,4 … 42,7 mm2/s. Obtained results of the measurements were presented in the form of the graphs of flow characteristics qv = f(Δp). Based on the results of measurements of examined flange, the calculations were made and average value of flow coefficient C = 0,895 was proposed for the range of changes of Reynolds number ReD = 100 ... 1000. The examples of the simulations of velocity and pressure distribution in the area of the flange were also presented.
Źródło:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej; 2019, 66; 63-66
1425-5766
2353-1290
Pojawia się w:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analysis of Applicability of Flow Averaging Pitot Tubes in the Areas of Flow Disturbance
Autorzy:
Pochwała, S.
Pospolita, J.
Powiązania:
https://bibliotekanauki.pl/articles/221838.pdf
Data publikacji:
2016
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
averaging Pitot tubes
flowmeter
measurement uncertainty
Opis:
The issues connected with the complex design of various facilities, including up-to-date boiler equipment as well as the ways of organizing the space around them, are the reasons why there is often a lack of room for mounting a flowmeter in accordance with the recommendations of manufacturers. In most cases the problem is associated with ensuring sufficient lengths of straight pipe leading into and out of a flowmeter. When this condition cannot be fulfilled, the uncertainty of measurement increases above the value guaranteed by the manufacturer of the flowmeter. This sort of operation problem has encouraged the authors of this paper to undertake research aimed at the analysis of applicability of averaging Pitot tubes in the areas of flow disturbance.
Źródło:
Metrology and Measurement Systems; 2016, 23, 1; 71-84
0860-8229
Pojawia się w:
Metrology and Measurement Systems
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies