Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "flicker" wg kryterium: Temat


Tytuł:
Analysis of supply parameters of single- and double-string LED lamps with integrated AC direct capacitorless drivers
Autorzy:
Chęciński, J.
Filus, Z.
Powiązania:
https://bibliotekanauki.pl/articles/201205.pdf
Data publikacji:
2020
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
SSL
LED
LED-COB
PWM
power factor
efficiency
flicker
SM2082
LED AC direct driver
Opis:
Thanks to a very high luminous efficacy of LED lamps (over 160 lm/W) they are the most preferred light sources in lighting applications today. The useful lifetime of LED modules exceeds 50,000 hours. Chromatic parameters of lamps making use of SSL (Solid State Lighting) have already equalled classic solutions, although they were noticeably worse not so long ago. High values of the Colour Rendering Index and (CRI) ease of control over the luminous flux cause that lamps with LEDs have become very attractive solutions. Today, the most important problem concerns LED drivers supplied from the 230 VAC mains. The lifetime of switched-mode converters, including electrolytic capacitors, is considerably shorter than that of LEDs. This paper discusses the features of alternative drivers for LED modules which are supplied directly from the 230 VAC mains and do not contain any electrolytic capacitors. In particular, power factor and efficiency of lamps with one or two strings are analysed and some hints concerning optimal design of such lamps are given. A unique feature of this work is a detailed analysis of harmonics contents in the supply current of such drivers, proving their conformity with the relevant standard. Finally, some problems associated with flicker resulting from the considered type of supply are mentioned.
Źródło:
Bulletin of the Polish Academy of Sciences. Technical Sciences; 2020, 68, 4; 819-827
0239-7528
Pojawia się w:
Bulletin of the Polish Academy of Sciences. Technical Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Cyfrowa realizacja odpowiedników analogowych filtrów miernika migotania światła przeznaczonych do implementacji w układach DSP
Digital realization of analog Flicker Meter filters for DSP implementation
Autorzy:
Duda, K.
Powiązania:
https://bibliotekanauki.pl/articles/156012.pdf
Data publikacji:
2007
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
miernik migotania światła
filtry cyfrowe
kwantyzacja współczynników filtrów cyfrowych
Flicker Meter
discretization of analog filters
quantization of digital filters
Opis:
Artykuł dotyczy analizy zagadnień związanych z cyfrową realizacją analogowych filtrów toru przetwarzania sygnału miernika migotania światła. Przeprowadzono łączną ocenę błędów przetwarzania sygnału spowodowanych zarówno cyfrową realizacją podawanych przez normę filtrów analogowych jak i kwantyzację współczynników ich cyfrowych odpowiedników. Na tej podstawie określono strukturę i współczynniki filtra cyfrowego o niskich wymaganiach sprzętowych przy jednoczesnym zachowaniu zgodności charakterystyk amplitudowych z wymaganiami dokumentów normatywnych. Dla implementacji stałoprzecinkowej podano konfigurację filtra dyskretnego w torze miernika migotania światła zapewniającą optymalne wykorzystanie dostępnej dynamiki obliczeń.
The paper addresses the problem of discrete realization of Flicker Meter filters. Simultaneous analysis of errors caused by discretization of analog filters and quantization of their digital equivalents is presented. On that basis the structure and coefficients of digital filter with low hardware requirements are given. The amplitude characteristics of digital filter are consistent with normative analog counterpart. For fixed-point implementation configuration of the digital filter in Flicker Meter is given what ensures the best usage of available dynamics of computations.
Źródło:
Pomiary Automatyka Kontrola; 2007, R. 53, nr 9 bis, 9 bis; 653-656
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Estimating the noise-related error in continuous-time integrator-based ADCs
Autorzy:
Gosselin, P.
Koukab, A.
Kayal, M.
Powiązania:
https://bibliotekanauki.pl/articles/398023.pdf
Data publikacji:
2016
Wydawca:
Politechnika Łódzka. Wydział Mikroelektroniki i Informatyki
Tematy:
noise
white noise
flicker noise
error
accuracy
standard deviation
variance
integrator-based ADC
incremental
Sigma-Delta
szum
szum biały
fliker-szum
błąd
dokładność
odchylenie standardowe
wariancja
ADC
Opis:
From first-order incremental ΣΔ converters to controlled-oscillator-based converters, many ADC architectures are based on the continuous-time integration of the input signal. However, the accuracy of such converters cannot be properly estimated without establishing the impact of noise. In fact, noise is also integrated, resulting in a random error that is added to the measured value. Since drifting phenomena may make simulations and practical measurements unable to ensure longterm reliability of the converters, a theoretical tool is required. This paper presents a solution to compute the standard deviation of the noise-generated error in continuous-time integrator-based ADCs, under the assumption that a previous measure is used to calibrate the system. In addition to produce a realistic case, this assumption allows to handle a theoretical issue that made the problem not properly solvable. The theory is developed, the equations are solved in the cases of pure white noise, pure flicker noise and low-pass filtered white noise, and the implementation issues implied by the provided formulas are addressed.
Źródło:
International Journal of Microelectronics and Computer Science; 2016, 7, 2; 54-59
2080-8755
2353-9607
Pojawia się w:
International Journal of Microelectronics and Computer Science
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Informational essence of flicker-noise
Informacyjna zawartość fliker-szumu
Autorzy:
Stadnyk, B
Kolodiy, Z.
Depko, P.
Powiązania:
https://bibliotekanauki.pl/articles/155028.pdf
Data publikacji:
2006
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
fliker-szum
gęstość widmowa
struktura wewnętrzna
flicker-noise
spectral density
internal structure
time of relaxation
Opis:
It was presented the computer simulation results of chaotic motion. They showed that flicker-constituent noises were contained the information about explored system features of internal structure. The criterion for estimation the change of mentioned structure by means of flicker-noises was offered.
Podano wyniki komputerowego modelowania chaotycznego ruchu, które pokazują, że fliker-składowa szumu zawiera informację o osobliwościach wewnętrznej struktury badanego systemu. Zaproponowano kryteria oceny zmiany wewnętrznej struktury na podstawi fliker-szumów.
Źródło:
Pomiary Automatyka Kontrola; 2006, R. 52, nr 12, 12; 50-52
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Long-Term Monitoring of Flicker and Some Other Parameters of Voltage Quality
Autorzy:
Krejci, P.
Santarius, P.
Gono, R.
Brunclik, Z.
Powiązania:
https://bibliotekanauki.pl/articles/136258.pdf
Data publikacji:
2016
Wydawca:
EEEIC International Barbara Leonowicz Szabłowska
Tematy:
flicker
unbalance
voltage harmonics
voltage quality
Opis:
In 1997 cooperation began between the Faculty of Electrical Engineering and Computer Science and the power company CEZ on a joint project that involved monitoring selected voltage quality parameters. Over the course of several years measurements were carried out at 59 points of the distribution system at a low voltage (LV) level and their power supply nodes at medium voltage (MV) and high voltage (HV) levels, which constituted more than 100 measured points. The measurements continued until 2012 (with a one-year break in 2009) and with a total scope of five cycles of three-year measurements. The last phase of the measurements was focused, inter alia, on the evaluation of 15th and 21st voltage harmonics. From 2013, the cooperation focused again on monitoring flicker in localities with the occurrence of elevated levels of this voltage quality parameter. At these sites, the monitoring of flicker was carried out for two weeks in spring and autumn for a period of three years. The basis for evaluating the quality parameters is the standard EN 50160. In addition the results of annual continual monitoring for one selected locality on MV level will be presented in the paper. In addition the possibility of utilization of intelligent electrometers for monitoring of some quality parameters will be referred in the paper.
Źródło:
Transactions on Environment and Electrical Engineering; 2016, 1, 3; 1-8
2450-5730
Pojawia się w:
Transactions on Environment and Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Measurement of Noise in Supercapacitors
Autorzy:
Szewczyk, A.
Powiązania:
https://bibliotekanauki.pl/articles/221256.pdf
Data publikacji:
2017
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
supercapacitor
flicker noise
measurement set-up
reliability
Opis:
A developed method and measurement setup for measurement of noise generated in a supercapacitor is presented. The requirements for noise data recording are considered and correlated with working modes of supercapacitors. An example of results of low-frequency noise measurements in commercially available supercapacitors are presented. The ability of flicker noise measurements suggests that they can be used to assess quality of tested supercapacitors.
Źródło:
Metrology and Measurement Systems; 2017, 24, 4; 645-652
0860-8229
Pojawia się w:
Metrology and Measurement Systems
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Metody pomiaru współczynnika migotania światła - flikera
Methods of light flicker measurements
Autorzy:
Olencki, A.
Urbański, K.
Powiązania:
https://bibliotekanauki.pl/articles/152815.pdf
Data publikacji:
2007
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
współczynnik migotania światła
fliker
jakość energii elektrycznej
kalibrator napięcia i prądu
kalibrator mocy
miernik
rejestrator
analizator parametrów sieci
voltage and current calibrator
flicker
power quality
power calibrator
power network parameters meter
recorder
analyzer
Opis:
W artykule przedstawiono, na tle parametrów jakości energii elektrycznej, zjawisko migotania światła i definicję współczynnika migotania tzw. flikera oraz sposób jego pomiaru zgodnie z normą IEC6100-4-15 (2003). Opisano alternatywną metodę pomiaru opartą na analizie częstotliwościowej oraz przedstawiono urządzenie pomiarowe działające w oparciu o opisywaną metodę. Zaprezentowano uzyskane wyniki pomiarów.
The article presents, on the background of power quality parameters, the phenomena of light intensity variations and definition of flicker coefficient and method of its measurement according to the IEC6100-4-15 (2003) standard. There is described an alternative method of measurement based on frequency spectrum analysis and meter, which works on this principle. Then, there are presented the results of measurements.
Źródło:
Pomiary Automatyka Kontrola; 2007, R. 53, nr 5, 5; 123-125
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Mitigation of voltage flicker by superconducting synchronous Condenser (SUPERVAR)
Autorzy:
Tsai, S. S.
Liu, Y.
Ingram, M. R.
Powiązania:
https://bibliotekanauki.pl/articles/262647.pdf
Data publikacji:
2005
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie
Tematy:
superconductivity
synchronous condenser
voltage flicker
power quality
Opis:
Voltage flicker caused by the electric arc furnace (EAF) and the mitigation using the superconducting synchronous condenser (SuperVAR) by the American Superconductor Corp. are considered in this paper. The modeling of EAF, SuperVAR and the system used are discussed. Fast reactive power support to reduce voltage flicker problem by an EAF is desirable. The voltage fluctuation amplitude is used as an index to evaluate the effectiveness of SuperVAR for two different MVar levels. At the PCC (point of common coupling) bus, the application of the SuperVAR can improve the voltage flicker by 6% and 19% by applying DC1A type and AC4A type exciter to the SuperVAR. With an DC1A type exciter, the SuperVAR can output only between +1 and -2 MVAR and with an AC4A type exciter the SuperVAR can provide its full rated power (8MVAR) to the system, making the voltage flicker a less severe.
Źródło:
Electrical Power Quality and Utilisation. Journal; 2005, 11, 1; 39-44
1896-4672
Pojawia się w:
Electrical Power Quality and Utilisation. Journal
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Portable exhaled breath analyzer employing fluctuation-enhanced gas sensing method in resistive gas sensors
Autorzy:
Kwiatkowski, A.
Chludziński, T.
Smulko, J.
Powiązania:
https://bibliotekanauki.pl/articles/220591.pdf
Data publikacji:
2018
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
resistance gas sensor
fluctuation enhanced sensing
flicker noise
gas detection
breath sample collection
Opis:
This paper presents a portable exhaled breath analyser, developed to detect selected diseases. The set-up employs resistive gas sensors: commercial MEMS sensors and prototype gas sensors made of WO3 gas sensing layers doped with various metal ingredients. The set-up can modulate the gas sensors by applying UV light to induce physical changes of the gas sensing layers. The sensors are placed in a tiny gas chamber of a volume of about 22 ml. Breath samples can be either injected or blown into the gas chamber when an additional pump is used to select the last breath phase. DC resistance and resistance fluctuations of selected sensors using separate channels are recorded by an external data acquisition board. Low-noise amplifiers with a selected gain were used together with a necessary bias circuit. The set-up monitors other atmospheric parameters interacting with the responses of resistive gas sensors (humidity, temperature, atmospheric pressure). The recorded data may be further analysed to determine optimal detection methods.
Źródło:
Metrology and Measurement Systems; 2018, 25, 3; 551-560
0860-8229
Pojawia się w:
Metrology and Measurement Systems
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Power Quality Measurements – the Importance of Traceable Calibration
Autorzy:
van den Brom, H. E.
Hoogenboom, D.
Powiązania:
https://bibliotekanauki.pl/articles/262833.pdf
Data publikacji:
2013
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie
Tematy:
calibration
power quality
reference system
standardization
traceability
harmonics
flicker
Opis:
Standardization has contributed significantly to comparable analysis methods for power quality parameters. However, in order to have undisputable results, the measurement values themselves should also be comparable. This can only be achieved by traceability to international measurement standards. For this reason, at VSL, the Dutch national metrology institute, a fully traceable reference setup was developed for calibration of power quality analyzers. In this paper, we show the calibration results of the critical components of the reference setup, we demonstrate its applicability by test measurements on the public low-voltage supply system for specific parameters, and show its ability to simulate and generate events that can be detected and analyzed by both the equipment under test and the reference setup.
Źródło:
Electrical Power Quality and Utilisation. Journal; 2013, 16, 1; 25-29
1896-4672
Pojawia się w:
Electrical Power Quality and Utilisation. Journal
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
System pomiarowy do wzorcowania mierników migotania światła w akredytowanym laboratorium wzorcującym
The measurement system for flickermeter calibration in accredited laboratory
Autorzy:
Pniewski, M.
Powiązania:
https://bibliotekanauki.pl/articles/158509.pdf
Data publikacji:
2013
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
wzorcowanie mierników migotania
wskaźnik migotania światła
flickermeter
calibration system
accredited laboratory
flicker indicator
Opis:
W artykule przedstawiono problematykę wzorcowania urządzeń umożliwiających pomiar wskaźnika krótkookresowego migotania światła - Pst. W szczególności zaproponowano metodę zachowania spójności pomiarowej przy odtwarzaniu wielkości odniesienia. Przedstawiono referencyjne stanowisko do odtwarzania sygnału reprezentującego wskaźnik Pst o zadanej wartości. Uwzględniono przy tym wytyczne norm IEC 17025, PN-EN 6100-4-30 oraz PN-EN 61000-4-15.
A method of flickermeter calibration is presented in the paper. Also the importance of the short-term flicker indicator is discussed. The method of traceability of the reference values is analyzed. A signal source reproducing the reference value of the Pst parameter is also discussed in the paper. The problem of construction of the flickermeter and principle of its operation is described. A method of establishing of traceability of reference values is suggested. Reference workstation to reconstruct signal with determined value of Pst is described. Standards and guidelines IEC 17025, EN 6100-4-30 and EN 61000-4-15 are regarded in the analysis. Study was carried out to determine the error and uncertainty of the reconstructed reference signal of known values of Pst. Both the error and the uncertainty of reconstructed signal with flicker voltage signal are transferred directly to the error and uncertainty of the reconstruction indicator. Basing on the conclusion, carrying out the more accurate calibration of flickermeter can take place in an accredited laboratory.
Źródło:
Pomiary Automatyka Kontrola; 2013, R. 59, nr 7, 7; 640-643
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Testowanie mierników migotania światła - flikermetrów
Testing of Flickermeters
Autorzy:
Olencki, A.
Powiązania:
https://bibliotekanauki.pl/articles/153433.pdf
Data publikacji:
2012
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
miernik migotania światła
Flikermetr
Kalibrator flikera
wahania napięcia
flickermeter
Flicker Calibrator
voltage fluctuaction
Opis:
Omówiono specyfikę testowania flikermetrów. Zaprezentowano dwie koncepcje budowy testera flikermetrów: pierwszą z zastosowaniem nieregulowanego źródła napięcia i przełączanego dzielnika napięcia oraz drugą z zastosowaniem regulowanego źródła napięcia. Przedstawiono wyniki badań czasu odpowiedzi opracowanego kalibratora mocy, które stały się podstawą do implementacji funkcji kalibratora flikera z zastosowaniem koncepcji regulowanego źródła napięcia. Zaprezentowano możliwości interfejsu użytkownika opracowanego kalibratora flikera oraz wyniki badań dokładności odtwarzania wskaźnika flikera Pst w funkcji częstości zmian napięcia. Nowością artykułu jest podjęcie tematu budowy krajowego kalibratora flikera z zastosowaniem koncepcji regulowanego źródła napięcia. W podsumowaniu można stwierdzić, że zaprezentowane wyniki badań potwierdzają możliwość zastosowania kalibratora dla potrzeb sprawdzania flikermetrów nawet klasy A w pełnym zakresie częstości zmian napięcia.
The problems of flickermeter testing are discussed. This paper presents two concepts of tester design: the first with an unregulated voltage source and a switchable voltage divider and the second with a regulated voltage source. The investigation results of the response time of a new power calibrator which are the basis for implementing a Flicker Calibrator function with using the regulated voltage source are given. The idea of a user interface of the Flicker Calibrator and the results of the accuracy of Pst reproduction as a function of the frequency of voltage changes are presented. A novelty of this paper is the issue of construction of the national Flicker Calibrator using the concept of a regulated voltage source. It can be concluded that the presented results confirm the possibility of using the Calibrator for checking the Class A flickermeters within the full time range of voltage changes.
Źródło:
Pomiary Automatyka Kontrola; 2012, R. 58, nr 6, 6; 487-490
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The Displaced Dispositif
Autorzy:
Edmonds, Guy
Lewin, Shaun
Powiązania:
https://bibliotekanauki.pl/articles/632525.pdf
Data publikacji:
2017
Wydawca:
Projekt Avant
Tematy:
early cinema
EEG
flicker
performance
sonification
Opis:
“Dispositif” is a term used in film studies since the 1970s to describe the entire system of mechanical and human factors which together bring about the cinema experience. It therefore refers to (amongst other things) the space of the auditorium, the screen, the projection technology and the physiology of the spectator. Many of its qualifying components are masked from the view of participants in the system. The dispositif’s purpose is to set up the conditions for a specific type of cognitive experience, one which mirrors and extends (and in some readings, controls) the experience of its participants.The Displaced Dispositif is a performance designed for the space of a cinema theatre, but featuring the projection of fragments of early silent cinema on a coeval (1910s) film projector from the auditorium. The film fragments are live-scored by the sound artist, Shaun Lewin, using a combination of closely mic’d sources on the projector itself, luminance data from the projected image and EEG brainwave data recorded from participants during previous projections of the film. Displacing elements in the dispositif in this way, by shifting modalities, situating in parallel, feeding back and layering, draws attention to its hidden existence and creates the potential for a more knowing and informed participation in the cinema experience. It also serves to demonstrate the degree to which dispositifs of modern cinema spectatorship, which have morphed and proliferated since the widespread digitization of film heritage, have radically altered both the technological and experiential qualities of the medium. By integrating EEG data, the performance adds the dimension of electrophysiological experience to the long tradition within experimental cinema of artists calling attention to Cinema’s hidden structures. As well as challenging the dominance of the worldview propagated by the film industry, the performance also signals a means of re-engaging with the creative potential of the system itself, once unshackled from its bonds to the reality effect and freed from the limits imposed by its commercializing instincts.
Źródło:
Avant; 2017, 8
2082-6710
Pojawia się w:
Avant
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The Relationship Between Critical Flicker Fusion Frequency (CFFF) and Temperamental Characteristics
Autorzy:
Łuczak, A.
Sobolewski, A.
Powiązania:
https://bibliotekanauki.pl/articles/89787.pdf
Data publikacji:
2000
Wydawca:
Centralny Instytut Ochrony Pracy
Tematy:
Critical Flicker Fusion Frequency (CFFF)
temperament
zachowania
Opis:
The analysis in this paper was based on data obtained from 80 male participants, aged 29-65. Critical Flicker Fusion Frequency (CFFF) was measured using the Flicker Test. The Formal Characteristics of Behaviour - Temperament Inventory (FCB-TI) by Strelau and Zawadzki (1993) was used for temperamental characteristics. The results of statistical analysis did not confirm a hypothesis about the correlation between CFFF level and 3 temperamental characteristics. There were no immediate relationships among those variables. Correlation was observed when the CFFF coefficient of variance, instead of average CFFF values, was taken into account, especially in the case of a division into 2 groups of participants, "reckless" and "unsure." It could be interesting to check in the future a hypothesis about the stability of selected types of reactions.
Źródło:
International Journal of Occupational Safety and Ergonomics; 2000, 6, 4; 493-505
1080-3548
Pojawia się w:
International Journal of Occupational Safety and Ergonomics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Urządzenie do oceny uciążliwości migotania światła
Device to estimate light flicking
Autorzy:
Rzeszutko, J.
Powiązania:
https://bibliotekanauki.pl/articles/320252.pdf
Data publikacji:
2008
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie. Wydawnictwo AGH
Tematy:
migotanie światła
ocena migotania światła
light flicking
flicker estimation
Opis:
Niniejszy artykuł opisuje prototypowe urządzenie do oceny uciążliwości migotania światła. Urządzenie zostało zbudowane, by sprawdzić działanie algorytmu zaproponowanego przez dr. hab. inż. Andrzeja Bienia [1]. W artykule przedstawiono wyniki badań przeprowadzonych nad algorytmem. Zweryfikowały one wpływ różnego rodzaju fluktuacji światła na wynik wskazywany przez przyrząd.
This paper presents the process of designing a device which estimate light flicking. Schematic idea is based on a flicker metter descibed in Polish Standard: PN-EN 60868:2002. It also describes the result of the symulation investigations of the device. In addtion to this, measure results have been presented and discussed.
Źródło:
Elektrotechnika i Elektronika; 2008, 27, 2; 111-114
1640-7202
Pojawia się w:
Elektrotechnika i Elektronika
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies