- Tytuł:
- Influence of the patellar button thickness on the knee flexion after total knee arthroplasty
- Autorzy:
-
Rosso, I.
Surface, C.
Antonaci, P.
Surface, F. M.
Negretto, R. J. - Powiązania:
- https://bibliotekanauki.pl/articles/949740.pdf
- Data publikacji:
- 2018
- Wydawca:
- Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
- Tematy:
-
rzepka
kąt zgięcia
osteoartroza
endoprotezoplastyka całkowita stawu kolanowego
modelowanie
osteoarthritis
total knee arthroplasty
patellar button
flexion angle
modeling - Opis:
- One of the main problems of knee replacement is the limit of knee flexion. This study focuses on the knee implant and the patellar component currently in use in total knee arthroplasty, analyzing the influence of patellar thickness on the degree of knee flexion following surgery. Methods: A kinematics study was performed to evaluate whether an optimal patellar thickness can be identified, which enables the maximum flexion angle to be achieved. Using TC images, a healthy model was built. On this basis, a model of a knee joint which had undergone total knee arthroplasty using a Legion PS prosthesis was constructed. Initially, the standard thickness of patellar implant (9 mm) was used to build the model; then several different patellar implant thicknesses (in the range of 5–15 mm) were analyzed. Results: The results show a non-linear trend: a button thickness of less than 9 mm does not change the flexion angle, whereas a button thickness of over 9 mm results in a loss of flexion. The flexion loss is significant in the first two additions of thicknesses but negligible in the last ones. Conclusions: In the case studied, flexion reduction is not linearly proportional to the patellar thickness. The outcome of total knee arthroplasty is considered to be satisfactory with the standard patellar button. The results of this study could be used to compare the kinematics with other total prosthesis and patellar implants, and should enable the optimization of the patellar residue bone thickness to obtain deep flexion.
- Źródło:
-
Acta of Bioengineering and Biomechanics; 2018, 20, 4; 121-134
1509-409X
2450-6303 - Pojawia się w:
- Acta of Bioengineering and Biomechanics
- Dostawca treści:
- Biblioteka Nauki