Life cycle assessment of glass/polyester laminates used in the shipbuilding industry and its fire behavior
Ocena cyklu życia laminatów szklano-poliestrowych stosowanych w przemyśle stoczniowym i ich reakcji na ogień
Autorzy:
Dowbysz, Adriana
Kukfisz, Bożena
Samsonowicz, Mariola
Markowska, Dorota
Jankowski, Piotr
Powiązania:
https://bibliotekanauki.pl/articles/24201152.pdf
Data publikacji:
2023
Wydawca:
Fundacja Ekonomistów Środowiska i Zasobów Naturalnych
Tematy:
glass-polyester laminate
life cycle assessment
cone calorimeter
Fire Test Procedures Code
laminat poliestrowo-szklany
ocena cyklu życia
kalorymetr stożkowy
międzynarodowy kodeks stosowania procedur prób ogniowych
Opis:
The aim of this study is to assess the environmental performance of the manufacturing process of glass/polyester laminates as well as estimate their fire behaviour and smoke release. The Life Cycle Assessment was conducted according to the ISO14040/44 standard by using the CML-IA 2000 Baseline Midpoint method. The cone calorimeter study was conducted using a cone calorimeter method according to ISO 5660. The tests were performed under 25 kW/m2 heat flux 50 kW/m2. The results showed that according to the requirements of the Fire Test Procedure (FTP) Code examined, laminates in this form cannot be used in some applications. The LCA study showed that the highest impact is attributed to marine aquatic ecotoxicity (88.3%), with the highest contribution of the unsaturated polyester resin and the glass fibre.
Celem pracy jest ocena wpływu procesu produkcji laminatów poliestrowo-szklanych na środowisko oraz ocena ich zachowania w warunkach pożaru. Ocenę cyklu życia przeprowadzono zgodnie z normą ISO14040/44, stosując metodę CML-IA 2000 Baseline. Badania kalorymetryczne przeprowadzono metodą kalorymetru stożkowego zgodnie z normą ISO 5660. Badania przeprowadzono przy gęstościach strumienia promieniowania cieplnego równych 25 kW/m2 i 50 kW/m2. Wyniki wykazały, że zgodnie z wymaganiami międzynarodowego kodeksu stosowania procedur prób ogniowych badane laminaty w tej postaci nie spełniają wymagań dotyczących niektórych zastosowań. Ocena cyklu życia wykazała, że proces produkcji laminatów oddziałuje w największym stopniu na toksyczność wody morskiej (88.3%), przy największym udziale nienasyconej żywicy poliestrowej i włókna szklanego.
Źródło:
Ekonomia i Środowisko; 2023, 2; 236--254
0867-8898
Pojawia się w:
Ekonomia i Środowisko
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Remedies to Thermal Radiation in Fused Silica Optical Fibers
Autorzy:
Borzycki, Krzysztof
Jaworski, Marek
Kossek, Tomasz
Powiązania:
https://bibliotekanauki.pl/articles/2200964.pdf
Data publikacji:
2023
Wydawca:
Instytut Łączności - Państwowy Instytut Badawczy
Tematy:
attenuation testing
fire resistant fiber optic cable
fire test
fused silica optical fiber
incandescent emission
interference filtering
Opis:
During fire incidents, optical fibers located with-in a fire-resistant cable are usually exposed to temperatures of 800◦C to 1000◦C. Hot fibers generate narrowband thermal (incandescent) radiation and collect broadband thermal radiation originating from the heated surroundings. The power of the second component, initially negligible, increases with time due to the rising number of fiber cracks and other defects acting as couplers for external radiation. Thermal radiation may interfere with fiber attenuation measurements performed during a fire test, but is rather unlikely to prevent data transmission with typical GbE and 10 GbE transceivers during a fire. This problem may be remedied by combining the following methods: using single mode fibers instead of multimode fibers, using bandpass filters to block thermal radiation, and selecting proper transmitter power, wavelength and photodetector.
Źródło:
Journal of Telecommunications and Information Technology; 2023, 1; 88--96
1509-4553
1899-8852
Pojawia się w:
Journal of Telecommunications and Information Technology
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
High Temperature Effects in Fused Silica Optical Fibers
Autorzy:
Borzycki, Krzysztof
Jaworski, Marek
Kossek, Tomasz
Powiązania:
https://bibliotekanauki.pl/articles/1839330.pdf
Data publikacji:
2021
Wydawca:
Instytut Łączności - Państwowy Instytut Badawczy
Tematy:
fire-resistant fiber optic cable
fire test
fused silica optical fibers
incandescence spectrum
thermal deterioration
thermal radiation
Opis:
Fire-resistant fiber optic cables used in safety and monitoring systems playing an essential role in fire fighting and building evacuation procedures are required to temporarily maintain optical continuity when exposed to fire. However, the use of fused silica fiber at temperatures between 800◦C and 1000◦C is associated with two highly undesirable phenomena. Thermal radiation (incandescence) of optical fibers, with its intensity and spectral distribution being proportional to additional attenuation observed in the fiber’s hydroxyl absorption bands (“water peaks”) is one of them. The other consists in penetration of thermal radiation from the surroundings into the fiber, due to defects in glass, causing light scattering and resulting in fiber brittleness. Thermal radiation is a source of interference in fiber attenuation measurements performed during fire tests and affects normal operation of fiber optic data links in the event of a fire. In this article, results of laboratory tests performed on a telecom single mode and multimode fibers subjected to temperatures of up to 1000◦C are presented.
Źródło:
Journal of Telecommunications and Information Technology; 2021, 3; 56-71
1509-4553
1899-8852
Pojawia się w:
Journal of Telecommunications and Information Technology
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
A general theoretical formulation of deformation of steel structures exposed to fire
Ogólne sformułowanie teoretyczne zagadnień deformacji elementów konstrukcji stalowych w warunkach pożaru
Autorzy:
Badowski, A.
Dornowski, W.
Powiązania:
https://bibliotekanauki.pl/articles/210072.pdf
Data publikacji:
2018
Wydawca:
Wojskowa Akademia Techniczna im. Jarosława Dąbrowskiego
Tematy:
analiza termomechaniczna
badanie ogniowe
lepkoplastyczne prawa konstytutywne
model Perzyny
thermomechanical analysis
fire resistance test
viscoplastic constitutive laws
Perzyna model
Opis:
This paper presents a proposal for the formulation of a mathematical model of a fire resistance testing process for steel beams subject to bending, carried out experimentally in a test furnace. The model for the formulation was created with a balance method by describing with the fundamental laws of thermomechanics the phenomena occurring during the experiment analysed for the formulation. The viscoplastic behave our of steel at high temperatures was described with constitutive relationships proposed by Perzyna (which form the so-called “overload model”). The general mathematical model of the experiment analysed, obtained in the form of a system of differential equations, is discussed. The authors considered the impact of known physical properties of the test material and the impact of the results of the observations made during the research on the behaviour of individual terms of the model’s equations. Based on these considerations, simplifications were proposed which optimized the mathematical description and facilitated its adaptation to a special case. As a result of the investigation, a system of equation was obtained which described the processes present during the fire resistance test. It is postulated here to accept the system of equations as the mathematical model.
W artykule przedstawiono propozycję sformułowania modelu matematycznego procesu badania nośności ogniowej stalowych belek zginanych, przeprowadzanego w piecu ogniowym. W celu opracowania tego modelu posłużono się metodą bilansową, opisując zjawiska zachodzące w trakcie analizowanego eksperymentu za pomocą podstawowych praw termomechaniki. Zachowanie lepkoplastyczne stali w wysokich temperaturach zmiennych w czasie opisano, używając związków konstytutywnych zaproponowanych przez Perzynę (tzw. model „przeciążeniowy”). Uzyskany w postaci układu równań różniczkowych ogólny model matematyczny analizowanego eksperymentu poddano dyskusji. Rozważono wpływ znanych właściwości fizycznych materiału i wyników obserwacji dokonanych w czasie badań na zachowania poszczególnych składników równań modelu. W efekcie zaproponowano uproszczenia umożliwiające zoptymalizowanie opisu matematycznego i jego dostosowanie do rozważanego przypadku szczególnego. Jako rezultat przeprowadzonych dociekań uzyskano układ równań opisujący procesy zachodzące w badaniu ogniowym, który postuluje się przyjąć jako jego model matematyczny.
Źródło:
Biuletyn Wojskowej Akademii Technicznej; 2018, 67, 2; 63-75
1234-5865
Pojawia się w:
Biuletyn Wojskowej Akademii Technicznej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Application of a sclerometer to the preliminary assessment of concrete quality in structures after fire
Wykorzystanie sklerometru do wstępnej oceny jakości betonu w konstrukcjach po pożarze
Autorzy:
Kowalski, R.
Wróblewska, J.
Powiązania:
https://bibliotekanauki.pl/articles/231307.pdf
Data publikacji:
2018
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
beton
temperatura wysoka
pożar
badanie nieniszczące
sklerometr
młotek Schmidta
liczba odbicia
concrete
high temperature
fire
non destructive test
sclerometer
Schmidt hammer
rebound number
Opis:
The paper presents a description and results of a study focused on the applicability of the sclerometric method to the preliminary assessment of concrete quality in structures after fire. Due to the high thermal inertia, concrete has non-uniform properties in the heated element cross-section. The greatest reduction of concrete compressive strength occurs on the heated surface. When assessing a structure after a fire, it is particularly important to determine the thickness of the damaged external concrete layer. Reinforced concrete beams exposed to high temperature on one side (a one-way heat transfer in the cross-section) for 0 (unheated element), 60, 120, 180 and 240 minutes were examined. A significant decrease of the rebound number on the elements heated surface was observed, depending on the heating duration. The obtained values of the relative rebound number reduction were comparable to the values of relative compressive strength decrease (determined on the basis of temperature) of concrete situated 15 mm from the heated surface.
W artykule przedstawiono opis i wyniki badań mających na celu sprawdzenie przydatności metody sklerometrycznej do wstępnej oceny jakości betonu w konstrukcjach po pożarze. Jednym z najistotniejszych zjawisk wpływających na nośność konstrukcji narażonej na warunki pożarowe jest obniżenie wytrzymałości betonu w wysokiej temperaturze w wyniku procesów fizyko-chemicznych i uszkodzeń mechanicznych zachodzących w jego strukturze. Ze względu na dużą bezwładność termiczną, beton przestaje mieć jednorodne właściwości w przekroju ogrzewanego elementu, a największa degradacja betonu zachodzi w strefie przypowierzchniowej. Podczas oceny konstrukcji po pożarze szczególnie istotne jest określenie grubości zewnętrznej warstwy przekroju elementu, w której beton jest na tyle uszkodzony, że należy go uznać za zniszczony. Z praktycznego punktu widzenia rozpatrywania nośności konstrukcji można przyjąć, że grubość tej warstwy odpowiada odległości izotermy 500°C od ogrzewanej krawędzi przekroju.
Źródło:
Archives of Civil Engineering; 2018, 64, 4/II; 171-186
1230-2945
Pojawia się w:
Archives of Civil Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Nowy gatunek stali konstrukcyjnej z dodatkiem stopowym 3% Al wykazujący zwiększoną odporność mechaniczną na oddziaływanie cieplne w warunkach pożaru
A new grade of structural steel containing 3% Al with increased mechanical resistance to heat effect during fire
Autorzy:
Garbarz, B.
Adamczyk, M.
Powiązania:
https://bibliotekanauki.pl/articles/182485.pdf
Data publikacji:
2017
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Metalurgii Żelaza im. Stanisława Staszica
Tematy:
stal odporna na pożar
stal
glin
mikropasmowość struktury
próba rozciągania
fire-resistant steel
aluminium-alloyed steel
structural microbanding
tensile test
Opis:
Artykuł zawiera wyniki badań nowego gatunku wysokowytrzymałej stali na bazie układu Fe-0,3%C-1,7%Mn-3%Al z dodatkami Cu i / lub Nb, o granicy plastyczności w temperaturze otoczenia minimum 500 MPa, charakteryzującego się dwufazową strukturą γ + α/δ w temperaturze walcowania na gorąco i wynikającą z tego podatnością do tworzenia mikropasmowości strukturalnej. Głównym celem badań nowego gatunku stali było ustalenie odporności mechanicznej na oddziaływanie cieplne w warunkach pożaru w zakresie temperatury 400÷600ºC. Odporność stali na oddziaływanie cieplne oceniono na podstawie wyrażonego w procentach stosunku wartości granicy plastyczności w podwyższonej temperaturze do wartości granicy plastyczności w temperaturze otoczenia: (Re(ET)/Re(RT))·100%. Wyniki badań wykazały, że nowa stal o granicy plastyczności w temperaturze otoczenia powyżej 500 MPa, charakteryzuje się istotnie większą odpornością na krótkotrwałe (standardowo 20 minut) oddziaływanie cieplne w wysokiej temperaturze do 600ºC mierzone współczynnikiem (Re(ET)/Re(RT))·100%, niż stosowane obecnie stale konstrukcyjne nie zawierające Mo w ilości minimum 0,5%.
The paper contains results of investigation of a new high strength steel grade based on a Fe-0.3%C-1.7%Mn-3%Al system with additions of Cu and / or Nb, with yield strength at ambient temperature minimum 500 MPa, showing a two-phase γ + α/δ structure at temperature of hot rolling and resulting from it ability to form structural microbanding. Main goal of the investigation of the new steel grade was to determine the mechanical resistance to heat impact under fire conditions at temperature range of 400÷600ºC. The resistance to influence of heat was quantified using the percentage ratio of yield strength value at elevated temperature to yield strength value at ambient temperature: (Re(ET)/Re(RT))·100%. Results of the research showed that the new steel with a yield strength at ambient temperature above 500 MPa has considerably higher resistance to a short time (typically 20 minutes) heat impact at high temperature till 600ºC, expressed by coefficient (Re(ET)/Re(RT))·100%, than currently used structural steels without addition of Mo in amount of minimum 0.5%.
Źródło:
Prace Instytutu Metalurgii Żelaza; 2017, T. 69, nr 4, 4; 2-18
0137-9941
Pojawia się w:
Prace Instytutu Metalurgii Żelaza
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Ocena poziomu sprawności fizycznej kadetów Szkoły Aspirantów Państwowej Straży Pożarnej w Krakowie w kontekście porównawczym
The assessment of the physical fitness of cadets from the Cracow State Fire Service Fire College – comparative study
Autorzy:
Brzozowska-Wicherek, E.
Maczuga, D.
Powiązania:
https://bibliotekanauki.pl/articles/136893.pdf
Data publikacji:
2017
Wydawca:
Szkoła Główna Służby Pożarniczej
Tematy:
sprawność fizyczna
straż pożarna
strażacy
test sprawności fizycznej
physical fitness
fire department
firefighters
fitness test
Opis:
Wysoki poziom sprawności fizycznej jest w wielu przypadkach warunkiem koniecznym do pełnienia określonej roli zawodowej. Strażacy wykonują działania w sytuacjach wymagających przytomności umysłu i rozwagi, szybkiej reakcji oraz dużej wytrzymałości psychofizycznej. Dlatego też poziom sprawności przyszłych funkcjonariuszy Państwowej Straży Pożarnej (PSP) jest istotnym problemem badawczym rzutującym na przyszłe perspektywy zawodowe tej grupy zawodowej. Celem artykułu było porównanie sprawności fizycznej pomiędzy słuchaczami Szkoły Aspirantów Państwowej Straży Pożarnej w Krakowie (SA PSP) kształcącymi się w trzech kolejnych rocznikach. Badaniem objęto 272 mężczyzn kształcących się w dwuletniej SA PSP. Ocenę zdolności motorycznej dokonano za pomocą testu Pilicza. Jako drugiego narzędzia badawczego użyto testu oceniającego sprawność fizyczną kandydatów do służby w PSP. Zastosowano następujące próby motoryczne: podciąganie na drążku, bieg po kopercie, skok w dal z miejsca, rzut dwukilogramową piłką lekarską, ćwiczenie wytrzymałościowe „Delfin”. Analizy statystyczne przeprowadzono przy użyciu programu Microsoft Excel pakietu Office firmy Microsoft oraz programu STATISTICA 8.0 firmy StatSoft. Oceny istotności różnic dokonano przy pomocy testu t-Studenta dla danych niezależnych. Statystyczną istotność różnic rozpatrywano na poziomie istotności dla p<0,05. Analiza wyników wykazała różnice w poziomie sprawności fizycznej pomiędzy badanymi kadetami, kształcącymi się w różnych latach. W podciąganiu na drążku najlepszy średni wynik uzyskali kadeci z grupy II (19 powtórzeń), natomiast w biegu po kopercie z grupy III, osiągając średni czas wynoszący 23,4 s. Grupa I uzyskała najwyższą średnią arytmetyczną próbach w skoku w dal z miejsca i rzucie piłką lekarską oburącz zza głowy oraz ćwiczeniu wytrzymałościowym Delfin. W badanych grupach, na podstawie wyników prób: podciągania na drążku, biegu po kopercie i skoku w dal z miejsca nie stwierdzono istotnych statystycznie różnic sprawności fizycznej. W pozostałych próbach odnotowano różnice istotne statystycznie. Ponadto zaobserwowano tendencję malejącą wyników w kolejnych rocznikach w próbach skoku w dal z miejsca, rzutu piłką lekarską oraz ćwiczeniu Delfin. Poziom sprawności fizycznej jest zróżnicowany zależnie od rocznika, zwłaszcza w próbie siły eksplozywnej kończyn górnych i ćwiczeniu wytrzymałościowym Delfin. Zaobserwowane różnice w poziomie sprawności fizycznej pomiędzy ocenianymi rocznikami mogą świadczyć o specyfice szkolenia pożarniczego. Należy systematycznie kontrolować u kandydatów, a następnie strażaków poziom sprawność fizycznej, która zapewnia wykonywanie zadań służbowych.
A high level of physical fitness is in many cases a necessary condition to perform a particular job role. Firefighters often carry out the rescue operations in situations requiring the high consciousness, deliberation, fast reaction and big psychophysical reliability. Therefore, the level of efficiency of future officers of the fire department is an important research problem impinging their future career prospects. The aim of this study was to evaluate and compare the physical fitness of three generations of the Fire College in Cracow and to show the direction of the trend of changes in physical fitness of this group of young people. The study included 272 men trained in a two-year Fire College of the State Fire Service(SFS) in Cracow. Motor skills were assessed using the Pilicz test. As the second research tool, the test evaluating the physical fitness necessary for candidates to serve in the SFS,was used.. To assess the motor efficiency ,the following tests were used: the pull-ups on a bar, the Zig-Zag test, the standing broad jump, the medicine ball throw, the Dolphin exercise. Statistical analysis were conducted using the Microsoft Office Excel and the STATISTICA 9.0 program made by the StatSoft. In turn, the significance of differences was evaluated with the application of the Student’s test for independent variables. The statistical significance was considered at p<0,05. The analysis of the results showed differences in the level of physical fitness between the cadets studied in different years. In the pull – up exercise, the best result was achieved in the group 2 (19 repetitions), while in the beep test the best results were in the group 3, reaching an average time of 23.4 seconds. Group 1 got the highest arithmetic mean of the long jump attempts and shot the ball with both hands behind the head and the “Dolphin” endurance exercise. In the tested groups, based on the results of the following tests: the pull ups ,the beep test, and the jump from the place, no statistically significant differences in physical fitness were observed.. In other trials the statistically significant differences were reported . In addition, the declining results in the subsequent years in the attempts in the standing broad jump, throw a medicine ball and the “Dolphin” exercise were observed. Conclusion. The fitness level is diversified depending on the generation especially in the attempt of explosive strength of upper limbs and the Dolphin endurance exercise. Observed differences in the level of the physical fitness between the tested cadets show how the specific fire training is. There must be systematical control of the level of physical efficiency of firefighters, which enables them to fulfill their duties in the SFS and carry out the rescue actions in the best way.
Źródło:
Zeszyty Naukowe SGSP / Szkoła Główna Służby Pożarniczej; 2017, 2, 62; 101-113
0239-5223
Pojawia się w:
Zeszyty Naukowe SGSP / Szkoła Główna Służby Pożarniczej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Study on electromechanical drives used in ventilation and smoke extraction systems
Badania napędów elektromechanicznych stosowanych w systemach oddymiania i wentylacji
Autorzy:
Zbrowski, A.
Samborski, T.
Powiązania:
https://bibliotekanauki.pl/articles/1366015.pdf
Data publikacji:
2014
Wydawca:
Polska Akademia Nauk. Polskie Naukowo-Techniczne Towarzystwo Eksploatacyjne PAN
Tematy:
test system
electromechanical drive
smoke extraction and ventilation
fire protection system
system badań
napęd elektromechaniczny
oddymianie
wentylacja
system ppoż
Opis:
The paper presents experimental tests for electromechanical drives for use in ventilation and smoke extraction systems of buildings. The determined characteristics (force, shift, current and voltage as a function of time) enable the assessment of applicability of these drives as the drives of flaps and windows in fire protection systems. The study was conducted using a developed test stand facilitating the determination of characteristics of work of linear and rotary drives in changeable temperatures.
W artykule przedstawiono badania eksperymentalne napędów elektromechanicznych pod kątem zastosowania w systemach wentylacji i oddymiania budynków. Wyznaczone charakterystyki (siła, przemieszczenie, prąd i napięcie zasilania w funkcji czasu) pozwalają na dokonanie oceny możliwości ich zastosowania do napędu klap i okien w systemach przeciwpożarowych. W badaniach wykorzystano opracowane stanowisko umożliwiające wyznaczanie charakterystyk pracy napędów liniowych i obrotowych w zmiennych warunkach temperatury.
Źródło:
Eksploatacja i Niezawodność; 2014, 16, 3; 367-376
1507-2711
Pojawia się w:
Eksploatacja i Niezawodność
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Badanie wpływu temperatur występujących w czasie pożaru oraz szokowego chłodzenia na przyczepność stali B500SP i BSt500S do betonu
Study of fire temperatures and shock cooling influence on the bond strength between steel B500SP and BSt500S to concrete
Autorzy:
Bednarek, Z.
Ogrodnik, P.
Kamocka-Bronisz, R.
Bronisz, S.
Powiązania:
https://bibliotekanauki.pl/articles/373782.pdf
Data publikacji:
2013
Wydawca:
Centrum Naukowo-Badawcze Ochrony Przeciwpożarowej im. Józefa Tuliszkowskiego
Tematy:
badanie przyczepności
konstrukcje żelbetowe
spadek przyczepności
szokowe chłodzenie
temperatury pożarowe
bond reduction
bond test
fire temperatures
reinforced concrete
shock cooling
Opis:
Artykuł prezentuje wyniki badań wpływu temperatur występujących podczas pożaru na przyczepność stali do betonu oraz oszacowanie tego wpływu na spadek przyczepności. W pracy przedstawiono wyniki badań przyczepności stali żebrowanej B500SP oraz BSt500S do betonu C30/37 w warunkach popożarowych (badanie "na zimno") z uwzględnieniem różnych warunków stygnięcia - w tym szokowego chłodzenia wodą w czasie akcji gaśniczych konstrukcji oraz w trakcie trwania pożaru (badanie "na gorąco"). We wszystkich przebadanych przypadkach stwierdzono znaczący spadek przyczepności na skutek oddziaływania wysokich temperatur. Przedmiot badań jest ściśle związany z bezpieczeństwem konstrukcji budowlanych w czasie trwania pożaru, jak i z oceną ich dalszego użytkowania po przebytym pożarze w wyniku prowadzenia działań gaśniczych. Badania realizowano w ramach projektu pt. "Innowacyjne środki i efektywne metody poprawy bezpieczeństwa i trwałości obiektów budowlanych i infrastruktury transportowej w strategii zrównoważonego rozwoju" POIG.01.01.02-10-106/09-01.
The paper presents results from the research of fire temperatures influence on steel-concrete bond and the estimation of this influence on bond reduction. In this paper the bond test results for ribbed steel B500SP and BSt500S to C30/37 concrete in the after-fire conditions ("cold test") including various cooling conditions - therein shock cooling by water in the course of construction extinguishing actions and in the fire ("hot test") has been described. In all studied cases a significant reduction of bond was stated as a result of high temperatures. The research subject is closely related to the construction structures safety during the fire and the after-fire construction structures usability resulting from conducted extinguishing actions. The research has been carried out as part of project: "Innovative measures and effective methods of improving the safety and the durability of buildings and transport infrastructure in the sustainable development strategy" POIG.01.01.02-10-106/09.-01.
Źródło:
Bezpieczeństwo i Technika Pożarnicza; 2013, 1; 67-73
1895-8443
Pojawia się w:
Bezpieczeństwo i Technika Pożarnicza
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Model validation of the SI test engine
Walidacja modelu badawczego silnika ZI
Autorzy:
Jamrozik, A.
Powiązania:
https://bibliotekanauki.pl/articles/792417.pdf
Data publikacji:
2013
Wydawca:
Komisja Motoryzacji i Energetyki Rolnictwa
Tematy:
engine test
spark ignition engine
internal combustion engine
numerical analysis
AVL FIRE software
combustion process
crank angle
thermal cycle
modelling
Źródło:
Teka Komisji Motoryzacji i Energetyki Rolnictwa; 2013, 13, 2
1641-7739
Pojawia się w:
Teka Komisji Motoryzacji i Energetyki Rolnictwa
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Performance on a Work-Simulating Firefighter Test Versus Approved Laboratory Tests for Firefighters and Applicants
Autorzy:
Von Heimburg, E.
Medbo, J. I.
Sandsund, M.
Reinertsen, R. E.
Powiązania:
https://bibliotekanauki.pl/articles/90966.pdf
Data publikacji:
2013
Wydawca:
Centralny Instytut Ochrony Pracy
Tematy:
endurance
fire fighting
gender
blood lactate concentration
VO2
strength tests
straż pożarna
wiek
wytrzymałość zmęczeniowa
test umiejętnościowy
strażak
doświadczenie zawodowe
Opis:
Aim. Firefighters must meet minimum physical demands. The Norwegian Labour Inspection Authority (NLIA) has approved a standardised treadmill walking test and 3 simple strength tests for smoke divers. The results of the Trondheim test were compared with those of the NLIA tests taking into account possible effects of age, experience level and gender. Methods. Four groups of participants took part in the tests: 19 young experienced firefighters, 24 senior male firefighters and inexperienced applicants, 12 male and 8 female. Results. Oxygen uptake (VO2) at exhaustion rose linearly by the duration of the treadmill test. Time spent on the Trondheim test was closely related to performance time and peak VO2 on the treadmill test. Senior experienced firefighters did not perform better than equally fit young applicants. However, female applicants performed poorer on the Trondheim test than on the treadmill test. Performance on the Trondheim test was not closely related to muscle strength beyond a minimum. Conclusion. Firefighters completing the Trondheim test in under 19 min fit the requirements of the NLIA treadmill test. The Trondheim test can be used as an alternative to the NLIA tests for testing aerobic fitness but not for muscular strength. Women’s result of the Trondheim test were poorer than the results of the NLIA treadmill test, probably because of their lower body mass.
Źródło:
International Journal of Occupational Safety and Ergonomics; 2013, 19, 2; 227-243
1080-3548
Pojawia się w:
International Journal of Occupational Safety and Ergonomics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Stan prac normalizacyjnych w Komitecie Technicznym CEN/TC 127
Updated information on standardization works in Technical Committee CEN/TC 127
Autorzy:
Borowy, A.
Powiązania:
https://bibliotekanauki.pl/articles/182821.pdf
Data publikacji:
2013
Wydawca:
Instytut Techniki Budowlanej
Tematy:
normalizacja europejska
CEN/TC 127
bezpieczeństwo pożarowe
norma polska
wdrożenie
reakcja na ogień
odporność ogniowa
metoda badań
European normalization
fire safety
Polish standard
implementation
reaction to fire
fire resistance
test method
Opis:
W artykule przedstawiono aktualny stan prac normalizacyjnych oraz kierunki dalszych prac w Komitecie Technicznym CEN/TC 127 ds. Bezpieczeństwa Pożarowego w Budynkach. Przeanalizowano stan wdrożenia w Polsce norm opracowanych przez Komitet Techniczny CEN/TC 127 i opublikowanych przez CEN. Niezależnie od prac normalizacyjnych dotyczących metod badań ogniowych wyrobów budowlanych i elementów budynku, obecnie mocno rozwijane są metody inżynierii bezpieczeństwa pożarowego. Wykorzystuje się tu zarówno różne programy numeryczne umożliwiające analizowanie rozprzestrzeniania dymu i ciepła w obiektach budowlanych, jak i możliwości ewakuacji ludzi z obiektu budowlanego.
In the paper the updated Information on standardization works and directions of further works in Technical Committee CEN/TC 127 Fire Safety in Buildings have been presented. Implementation of the standards developed by Technical Committee CEN/TC 127 and published by CEN in Poland has been analyzed. Apart of the standardization works concerning fire test methods for construction products and building elements, currently, fire safety engineering methods are developed. Different numerical codes allowing analysis of smoke and heat spreading in construction works as well as the evacuation of people from construction works are used.
Źródło:
Prace Instytutu Techniki Budowlanej; 2013, R. 42, nr 3, 3; 23-37
0138-0796
Pojawia się w:
Prace Instytutu Techniki Budowlanej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Zachowanie się przewodów i kabli elektrycznych w pożarach
Behaviour of electric cables in fire
Autorzy:
Barasiński, A.
Czaja, P.
Powiązania:
https://bibliotekanauki.pl/articles/103581.pdf
Data publikacji:
2013
Wydawca:
Uniwersytet Humanistyczno-Przyrodniczy im. Jana Długosza w Częstochowie. Wydawnictwo Uczelniane
Tematy:
badania palności kabli
wskaźnik tlenowy
rozprzestrzenianie płomienia
izolacja ognioodporna
flammability test cables
oxygen index
spread of flame
fire-resistant insulation
Opis:
Powstające pożary w obiektach budowlanych pochłaniają liczne ofiary oraz są przyczyną licznych obrażeń i zatruć mieszkańców i użytkowników. Szczególnie groźne dla ludzi są pożary obiektów, w których na niewielkiej przestrzeni przebywa wiele osób, np. sale koncertowe i widowiskowe, dworce, szpitale, porty lotnicze itp. W wymienionych obiektach obowiązują szczególne wymagania ochrony przeciwpożarowej. Ponieważ przewody i kable są integralną częścią wszelkich budynków i obiektów, narażone są na działanie ognia, tak jak inne zainstalowane w nich urządzenia i wyposażenie. Stosowane tworzywa sztuczne do produkcji przewodów i kabli w przypadku pożaru wydzielają gęste dymy, które ograniczają widoczność i utrudniają prowadzenie akcji ratowniczo-gaśniczych. Wydzielają również agresywne gazy, groźne dla zdrowia, a nawet życia ludzi przebywających w zagrożonych pomieszczeniach. W przypadku gdy pożar obejmie swoim wpływem przewody i kable, istotna staje się znajomości ich zachowania w takich warunkach. Obecnie wymaga się, aby palące się kable i przewody wydzielały niewielkie ilości dymu i jak najmniej ciepła, a nie wydzielały trujących i agresywnych gazów oraz nie rozprzestrzeniały ognia. W artykule przedstawiono podstawowe wskaźniki oraz zakres przeprowadzanych prób badawczych, na podstawie których ocenia się zachowanie kabli i przewodów w warunkach pożaru.
Occurring fires in buildings absorb many victims and cause several injuries and poison for residents and users. Especially dangerous for people are fires where there is a lot of users in the same time like: concerts, railway stations, hospitals, air ports etc. In places mentioned earlier there are special requirements in addition to fire protection. Because the wires and cables are an integral part of all buildings and facilities they are vulnerable to fire, as Rother devices installed and accessories. Plastics used to manufacture wires and cables in case of fire, emit dense smoke that reduces visibility and makes it difficult to coordinate rescue action and fire fighting. They also emit corrosive gases, dangerous to the health and lives of people. In the event that a fire will cover wires and cables, important is the knowledge of their behavior under such conditions. Currently is required from cables and wires to create small amounts of smoke and very little heat, do not secrete toxic and corrosive gases and do not spread fire. In the article there were presented main indicators and the range of research trials conducted on which basis behavior of the cables an wires is judged in case of fire.
Źródło:
Prace Naukowe Akademii im. Jana Długosza w Częstochowie. Technika, Informatyka, Inżynieria Bezpieczeństwa; 2013, T. 1; 15-24
2300-5343
Pojawia się w:
Prace Naukowe Akademii im. Jana Długosza w Częstochowie. Technika, Informatyka, Inżynieria Bezpieczeństwa
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Stan prac normalizacyjnych w Komitecie Technicznym CEN/TC 127
Updated information on standardization works in Technical Committee CEN/TC 127 Fire safety in buildings
Autorzy:
Borowy, A.
Powiązania:
https://bibliotekanauki.pl/articles/183301.pdf
Data publikacji:
2012
Wydawca:
Instytut Techniki Budowlanej
Tematy:
CEN/TC 127
normalizacja europejska
bezpieczeństwo pożarowe
budynek
odporność ogniowa
klasyfikacja ogniowa
metoda badań
European standardization
fire safety
building
fire resistance
fire classification
test method
Opis:
Przedstawiono aktualny stan prac normalizacyjnych oraz kierunki dalszych prac w Komitecie Technicznym CEN/TC 127 ds. bezpieczeństwa pożarowego w budynkach. Przeanalizowano stan wdrożenia w Polsce norm opracowanych przez Komitet Techniczny CEN/TC 127 i opublikowanych przez CEN oraz możliwość prowadzenia w kraju badań zgodnie z tymi normami.
Updated information on standardization works and directions of further works in Technical Committee CEN/TC 127 Fire Safety in Buildings have been presented. Implementation of standards developed by Technical Committee CEN/TC 127 and published by CEN and availability of carrying out tests in accordance with these standards in Poland has been analyzed.
Źródło:
Prace Instytutu Techniki Budowlanej; 2012, R. 41, nr 1, 1; 37-51
0138-0796
Pojawia się w:
Prace Instytutu Techniki Budowlanej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Stateczność pojazdów pożarniczych - metody badań
Fire-fighting vehicles roll stability - tests methods
Autorzy:
Kupicz, W.
Powiązania:
https://bibliotekanauki.pl/articles/373103.pdf
Data publikacji:
2011
Wydawca:
Centrum Naukowo-Badawcze Ochrony Przeciwpożarowej im. Józefa Tuliszkowskiego
Tematy:
badania drogowe
bezpieczeństwo
pojazdy pożarnicze
stateczność pojazdu
fire-fighting vehicles
road test method
safety of traffic
vehicle stability
Opis:
W artykule przedstawiono metody badan stateczności poprzecznej pojazdów pożarniczych, zgodne z wymaganiami normy. Podkreślono niedostateczna ilość informacji uzyskiwanych w statycznych metodach wyznaczania kata przechyłu bocznego, zaproponowano rozszerzenie zakresu pomiarów o metody dynamiczne, zaprezentowano urządzenie do pomiarów kierowalności i stateczności w badaniach drogowych, omówiono metody badawcze i przedstawiono przykładowe wyniki.
This article presents methods for transverse stability testing of fire brigade vehicles, in accordance with standard requirements. The insufficient amount of information that is obtained in the static methods for determining the lateral yaw angle has been highlighted, the measurements scope was proposed to be extended by dynamic methods, a device for measuring steerability and stability in road studies was presented, as well as research methods were discussed and exemplary results were presented.
Źródło:
Bezpieczeństwo i Technika Pożarnicza; 2011, 1; 79-88
1895-8443
Pojawia się w:
Bezpieczeństwo i Technika Pożarnicza
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies