Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "fire resistance" wg kryterium: Temat


Tytuł:
Influence of terephthalic and orthophthalic units on the properties of polyols and polyurethane foams
Wpływ jednostek tereftalowych i ortoftalowych na właściwości polioli i pianek poliuretanowych
Autorzy:
Tarnawski, Wiesław
Tokarski, Mateusz
Czernecka, Wiktoria
Powiązania:
https://bibliotekanauki.pl/articles/24202841.pdf
Data publikacji:
2023
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Chemii Przemysłowej
Tematy:
aromatic polyester polyol
fire resistance
thermal stability
aromatyczny poliol poliestrowy
ognioodporność
stabilność termiczna
Opis:
The effect of aromatic ring substitution in the polyester polyol molecule on its physicochemical properties and on the conditions of synthesis, fire resistance and thermal stability of polyurethane foams was investigated. The greater number of terephthalic units in the polyol results in greater viscosity and reactivity during foam formation. The obtained foams were characterized by higher thermal stability (TGA) and fire resistance (oxygen index, single flame test).
Zbadano wpływ podstawienia pierścienia aromatycznego w cząsteczce poliolu poliestrowego na jego właściwości fizykochemiczne oraz na warunki syntezy, odporność na działanie ognia i stabilność termiczną pianek poliuretanowych. Większa liczba jednostek tereftalowych w poliolu skutkuje większą lepkością i reaktywnością podczas tworzenia pianek. Otrzymane pianki charakteryzowały się większą stabilnością termiczną (TGA) i odpornością na działanie ognia (indeks tlenowy, test pojedynczego płomienia).
Źródło:
Polimery; 2023, 68, 6; 337--343
0032-2725
Pojawia się w:
Polimery
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Insurrectionist Anarchism and Liberational Violence: New Ideas and Trends
Autorzy:
Posłuszna, Elżbieta
Powiązania:
https://bibliotekanauki.pl/articles/2197900.pdf
Data publikacji:
2023-03-31
Wydawca:
Wydawnictwo Adam Marszałek
Tematy:
anarchism
insurrectionist anarchism
Conspiracy of Cells of Fire
leaderless
resistance
liberational violence
Opis:
The paper characterises contemporary fighting anarchism from the ideological, tactical, and organisational perspectives. An analysis is carried out that examines the activities of the groups revoking insurrectionism, which today entails three ideological trends, namely social, individualistic (illegalism), and ecological. In the author’s intention, the characteristics should serve practical goals, i.e., forming a prognosis regarding the phenomenon's future and drawing possible ways to counteract its proliferation in a further perspective. Contemporary anarchism, due to its intellectual allure (liberationist individualism), broadening the scope of its goals (with the liberation of non-human beings), adopting loose organisational forms, as well as employing the leaderless resistance strategy and swarming, is a phenomenon that has significant development potential. The development of anarchism, due to ongoing socio-political processes (the collapse of the existing mechanisms of social control and political representation, globalisation, informatisation) and the widely spreading ideology of individualism will lead to, as it seems, progressive radicalism, both in ideology and used methods.
Źródło:
Polish Political Science Yearbook; 2023, 1(52); 29-40
0208-7375
Pojawia się w:
Polish Political Science Yearbook
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Fire Resistance of Aluminum-Glass Partitions with a Parallel Structure of Intumescent Layers
Odporność ogniowa przegród aluminiowo-szklanych o strukturze równoległej warstw pęczniejących
Autorzy:
Gwóźdź, Marian
Marcinowski, Michał
Powiązania:
https://bibliotekanauki.pl/articles/2060722.pdf
Data publikacji:
2022
Wydawca:
Centrum Naukowo-Badawcze Ochrony Przeciwpożarowej im. Józefa Tuliszkowskiego
Tematy:
glass
partitions
laboratory tests
fire resistance
reliability
niezawodność
testy laboratoryjne
szkło
odporność ogniowa
przegrody
Opis:
Aim: The aim of the article is to verify the fire resistance of aluminum-glass construction partitions with a parallel structure. The paper presents the results of tests in a fire chamber of a selected partition, a leading national manufacturer of aluminum-glass systems. The results of the fire tests were used to validate a simple parallel model of the reliability of non-renewable systems. Introduction: Fire-retardant properties of partitions made of glass and aluminum profiles determine their ability to stop the spread of fire by closing the fire in separate zones. Fire resistance of such partitions is measured according to various criteria, in particular the requirements concern: stability R (glass does not break), tightness E, radiation limitation W and insulation I. The tightness requirement E means that the partition effectively protects the fire compartment against flames, smoke and hot gases. The insulating postulate I means that the average temperature of glass and the profiles on the surface of the partition on the protected side does not exceed the contractual value during the nominal duration of the fire. The measure of fire resistance of a partition is time t, expressed in minutes, in which the structure of an aluminum-glass partition meets one or more of the criteria listed. Methodology: The experimental database consists of the results of routine fire resistance tests of system building partitions obtained in the certification process of selected facade systems. Interpretation of the obtained results of laboratory tests was based on simple models of reliability of non-renewable systems. Conclusions: The graphs of average temperature increase on the outer surface of the tested glass are the same in each case in terms of quality and quantity. Up to about 70% of the nominal fire resistance, the temperature increase is linear, followed by a non-linear phase according to a concave curve. The course of the temperature-rise curves on the outer surface of aluminum profiles is qualitatively different. The graphs are non-linear, convex from the beginning of heating, with the inflection point reached after about 20 minutes of the test. The obtained results may indicate that the multi-chamber structure of aluminum profiles does not ensure a parallel reliability structure, because the object has a quasi-parallel structure. The presented results of the temperature-rise curves and their reliability interpretation require confirmation in further laboratory tests of aluminum-glass partitions with a different structure of panes and profiles.
Cel: Celem artykułu jest weryfikacja eksperymentalna odporności ogniowej przegród budowlanych aluminiowo-szklanych o strukturze równoległej. W pracy przedstawiono wyniki badań w komorze ogniowej na przykładzie przegrody wiodącego krajowego producenta systemów aluminiowo-szklanych. Wyniki testów ogniowych wykorzystano do walidacji prostego modelu równoległego niezawodności systemów nieodnawialnych. Wprowadzenie: Właściwości ognioochronne wykonanych ze szkła i profili aluminiowych przegród budowlanych określają ich zdolność do zatrzymania rozprzestrzeniania się ognia poprzez zamknięcie pożaru w wydzielonych strefach. Odporność ogniowa takich przegród jest mierzona wg różnych kryteriów. W szczególności wymagania dotyczą: stabilności R (szkło nie pęka), szczelności E, ograniczenia promieniowania W i izolacyjności I. Postulat szczelności E oznacza, że przegroda skutecznie chroni strefę wydzielenia pożarowego przed płomieniami, dymem i gorącymi gazami. Z kolei postulat izolacyjności I świadczy o tym, że średnia temperatura szyb i profili na powierzchni przegrody po stronie chronionej nie przekracza umownej wartości w nominalnym czasie trwania pożaru. Miarą odporności ogniowej przegrody jest czas t wyrażony w minutach, w którym konstrukcja przegrody aluminiowo-szklanej spełnia jedno lub kilka z wymienionych kryteriów. Metodologia: Bazę danych doświadczalnych stanowią wyniki rutynowych badań odporności ogniowej systemowych przegród budowlanych otrzymane w procesie certyfikacji wybranych systemów fasadowych. Interpretację wyników badań laboratoryjnych oparto na prostych modelach niezawodności systemów nieodnawialnych. Wnioski: Wykresy przyrostu temperatury średniej na zewnętrznej powierzchni badanych szyb są w każdym wypadku jakościowo i ilościowo takie same. Do momentu osiągnięcia około 70% nominalnej ogniochronności przyrost temperatury jest liniowy, po czym następuje faza nieliniowa wg krzywej wklęsłej. Jakościowo inny jest przebieg krzywych przyrostu temperatury na zewnętrznej powierzchni profili aluminiowych. Wykresy są od początku nagrzewania nieliniowe, wypukłe, z punktem przegięcia osiągniętym już po około 20 minutach testu. Otrzymane rezultaty mogą wskazywać, że wielokomorowość profili aluminiowych nie zapewnia struktury niezawodnościowej równoległej, ponieważ obiekt ma strukturę quasi-równoległą. Przedstawione wyniki krzywych przyrostu temperatury i ich interpretacja niezawodnościowa wymagają potwierdzenia w dalszych badaniach laboratoryjnych przegród aluminiowo-szklanych o innej konstrukcji szyb i profili.
Źródło:
Safety and Fire Technology; 2022, 59, 1; 130--140
2657-8808
2658-0810
Pojawia się w:
Safety and Fire Technology
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Review of fibers and fabrics used for special services’ protective clothing in terms of their mechanical and thermal properties
Przegląd włókien i tkanin stosowanych w odzieży ochronnej służb specjalnych w aspekcie ich właściwości mechanicznych i cieplnych
Autorzy:
Miedzińska, Danuta
Wolański, Robert
Powiązania:
https://bibliotekanauki.pl/articles/2203147.pdf
Data publikacji:
2022
Wydawca:
Wojskowa Akademia Techniczna im. Jarosława Dąbrowskiego
Tematy:
mechanical engineering
fibers
special fabrics
fire resistance
mechanical strength
national and EU standards
inżynieria mechaniczna
włókna
tkaniny specjalne
ognioodporność
wytrzymałość mechaniczna
normatywy krajowe i EU
Opis:
In the paper, special clothing is understood as protective clothing used by services, in particular fire services, but also military and police, working in fire hazard conditions, where the main risk factors for the user are: a high temperature, a contact with hot objects, and a mechanical damage. The presented study deals with the review of special clothing industry and discusses cloths structure for compliance with national and European regulations. The parameters of technical fibers used for production of the above-mentioned clothes used during firefighting in open spaces, made of flame retardant yarns, e.g., aramid yarns or mixtures of flame retardant yarns, were analysed.
W artykule ubrania specjalne rozumiane są jako odzież ochronna stosowana przez służby, w szczególności pożarnicze, ale także wojskowe i policyjne, pracujące w warunkach zagrożenia pożarowego, gdzie głównymi czynnikami ryzyka dla użytkownika są: wysoka temperatura, kontakt z gorącymi przedmiotami i uszkodzenia mechaniczne. W pracy dokonano rozpoznania branży produkcji ubrań specjalnych i omówiono ich budowę w odniesieniu do zgodności z przepisami krajowymi i europejskimi. analizie poddano parametry włókien technicznych służących do produkcji ww. ubrań stosowanych podczas gaszenia pożarów w przestrzeni otwartej, wykonanych z przędz trudnopalnych, np. aramidowych, lub z mieszanek przędz trudnopalnych.
Źródło:
Biuletyn Wojskowej Akademii Technicznej; 2022, 71, 1; 15--34
1234-5865
Pojawia się w:
Biuletyn Wojskowej Akademii Technicznej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Odporność ogniowa konstrukcji słupowych zabezpieczonych okładzinami z gipsu syntetycznego
Fire resistance of pole structures protected with synthetic plastering
Autorzy:
Kania, Tomasz
Powiązania:
https://bibliotekanauki.pl/articles/2055983.pdf
Data publikacji:
2021
Wydawca:
Polski Związek Inżynierów i Techników Budownictwa
Tematy:
konstrukcja prętowa
słup stalowy
zabezpieczenie ogniochronne
okładzina gipsowa
gips syntetyczny
odporność ogniowa
ściana gipsowa
izolacyjność ogniowa
pomiar temperatury
klasyfikacja ogniowa
bar structure
steel column
fire barrier
gypsum panel cladding
synthetic gypsum
fire resistance
gypsum wall board
fire insulation
temperature measurement
fire classification
Opis:
Konstrukcje prętowe, do jakich zaliczamy słupy, nie pełnią zwykle funkcji oddzielającej, w związku z czym powinny spełniać jedynie kryterium nośności ogniowej (R). Jednak w sytuacji, gdy słup tworzy ciągłą przegrodę z przylegającą do niego ścianą, wymagane są w stosunku do niego także dwa pozostałe kryteria: szczelności (E) oraz izolacyjności ogniowej (I). W artykule przedstawiono rozwiązanie zabezpieczeń przeciwpożarowych stalowych słupów konstrukcyjnych z wykorzystaniem okładzin z gipsu syntetycznego, materiału odpadowego uzyskanego w procesie odsiarczania spalin z paliw kopalnych metodą mokrą wapienną.
Bar structures, which include columns, usually do not have a separating function, and therefore should only meet the fire resistance (R) criterion. However, when a column forms a continuous partition with an adjacent wall, two other criteria are also required: tightness (E) and fire insulation (I). The article presents a fire protection solution for structural steel columns with the use of synthetic gypsum cladding, a waste material obtained in the process of desulphurization of fossil fuels using the wet lime method.
Źródło:
Przegląd Budowlany; 2021, 92, 11-12; 119--121
0033-2038
Pojawia się w:
Przegląd Budowlany
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Odporność ogniowa konstrukcji słupowych zabezpieczonych okładzinami z gipsu syntetycznego
Fire resistance of pole structures protected with synthetic plastering
Autorzy:
Kania, Tomasz
Powiązania:
https://bibliotekanauki.pl/articles/2055957.pdf
Data publikacji:
2021
Wydawca:
Polski Związek Inżynierów i Techników Budownictwa
Tematy:
konstrukcja prętowa
słup stalowy
zabezpieczenie ogniochronne
okładzina gipsowa
gips syntetyczny
odporność ogniowa
ściana gipsowa
izolacyjność ogniowa
pomiar temperatury
klasyfikacja ogniowa
bar structure
steel column
fire barrier
gypsum panel cladding
synthetic gypsum
fire resistance
gypsum wall board
fire insulation
temperature measurement
fire classification
Opis:
Konstrukcje prętowe, do jakich zaliczamy słupy, nie pełnią zwykle funkcji oddzielającej, w związku z czym powinny spełniać jedynie kryterium nośności ogniowej (R). Jednak w sytuacji, gdy słup tworzy ciągłą przegrodę z przylegającą do niego ścianą, wymagane są w stosunku do niego także dwa pozostałe kryteria: szczelności (E) oraz izolacyjności ogniowej (I). w artykule przedstawiono rozwiązanie zabezpieczeń przeciwpożarowych stalowych słupów konstrukcyjnych z wykorzystaniem okładzin z gipsu syntetycznego, materiału odpadowego uzyskanego w procesie odsiarczania spalin z paliw kopalnych metodą mokrą wapienną.
Bar structures, which include columns, usually do not have a separating function, and therefore should only meet the fire resistance (R) criterion. However, when a column forms a continuous partition with an adjacent wall, two other criteria are also required: tightness (E) and fire insulation (I). The article presents a fire protection solution for structural steel columns with the use of synthetic gypsum cladding, a waste material obtained in the process of desulphurization of fossil fuels using the wet lime method.
Źródło:
Przegląd Budowlany; 2021, 92, 11-12; 119--121
0033-2038
Pojawia się w:
Przegląd Budowlany
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Ambiguity in determining the critical temperature of a steel sway frame with semi-rigid joints
Niejednoznaczność w wyznaczaniu temperatury krytycznej stalowej ramy przechyłowej z podatnymi węzłami
Autorzy:
Maslak, M.
Pazdanowski, M.
Snela, M.
Powiązania:
https://bibliotekanauki.pl/articles/1849756.pdf
Data publikacji:
2020
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
odporność ogniowa
rama stalowa
temperatura krytyczna
węzeł sztywny
węzeł półsztywny
węzeł doczołowy
węzeł belka-słup
fire resistance
steel frame
critical temperature
fully rigid joint
semi rigid joint
end plate joint
beam to column joint
Opis:
The problem of uniqueness and representativeness of steel frame fire resistance assessment is considered in this paper. The thesis, that the selection of analysis method determines the result in both qualitative and quantitative terms is given scrutiny. It is also shown, that the differences between computed values may be significant. The selection of an appropriate computational model for an analysis of this type seems to be especially important, as the possible overestimation of the fire resistance determined during computation is equivalent to an unjustified optimism of the user with respect to the safety level warranted. In the considerations presented here the critical temperature determined for the whole bearing structure is considered as the measure of sought resistance. The determined temperature is associated with the bearing structure reaching the bearing capacity limit state subject to fire conditions, treated as accidental design situation. Two alternative computational methods have been applied during calculations: the first one - classical, based on 1st order statics and using the buckling length concept for members of the considered frame, and the second one - taking account of 2nd order phenomena via simple amplification of the horizontal loads applied to the frame. Special attention has been paid to the influence exerted on the final fire resistance of the considered structure by the real joint rigidity, decreasing with increasing temperature of the structural members. The obtained results differ not only in the value of determined temperature but also in the indicated location of the weakest frame component, determining its safety.
W pracy rozważa się problem jednoznaczności i reprezentatywności oszacowania odporności ogniowej ramy stalowej. Weryfikacji poddano tezę, że wybór metody analizy determinuje uzyskany wynik zarówno pod względem ilościowym jak i jakościowym, a różnice pomiędzy wyliczonymi wartościami mogą okazać się znaczące. Dobór miarodajnego modelu obliczeniowego w tego typu analizie wydaje się być szczególnie ważny, bowiem ewentualne przeszacowanie wyznaczonej z obliczeń odporności jest równoznaczne z nieuzasadnionym optymizmem użytkownika budynku co do gwarantowanego mu poziomu bezpieczeństwa. W prezentowanych rozważaniach miarą poszukiwanej odporności jest temperatura krytyczna specyfikowana dla całego ustroju nośnego. Nie zależy ona od prognozowanego scenariusza rozwoju pożaru i z tego względu może zostać uznana za pewnego rodzaju charakterystykę samej konstrukcji. Wyznaczana temperatura kojarzona jest z osiągnięciem przez ustrój nośny stanu granicznego nośności w warunkach pożaru traktowanego jako wyjątkowa sytuacja projektowa. Nie oznacza to jednak natychmiastowej katastrofy badanej konstrukcji ale jedynie sytuację, gdy prawdopodobieństwo tego rodzaju zdarzenia staje się już na tyle duże że nie może być dalej akceptowane. Do szczegółowej analizy wykorzystano dwie alternatywne procedury obliczeń: pierwszą - opartą o klasyczną statykę pierwszego rzędu, z wykorzystaniem koncepcji długości wyboczeniowej elementów badanej ramy, i drugą - uwzględniającą efekty drugiego rzędu przez prostą amplifikację przyłożonego do tej ramy obciążenia poziomego.
Źródło:
Archives of Civil Engineering; 2020, 66, 4; 611-632
1230-2945
Pojawia się w:
Archives of Civil Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Fire resistance and mechanical properties of powder-epoxy composites reinforced with recycled glass fiber laminate
Odporność na płomień oraz właściwości mechaniczne kompozytów proszkowej żywicy epoksydowej wzmocnionej recyklatem laminatu z włóknem szklanym
Autorzy:
Oliwa, Rafał
Bulanda, Katarzyna
Oleksy, Mariusz
Ostyńska, Paulina
Budzik, Grzegorz
Płocińska, Magdalena
Krauze, Sławomir
Powiązania:
https://bibliotekanauki.pl/articles/947108.pdf
Data publikacji:
2020
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Chemii Przemysłowej
Tematy:
proszkowa żywica epoksydowa
kompozyty
odpady
recykling
właściwości mechaniczne
odporność na płomień
powder-epoxy resin
composites
waste
recycling
mechanical properties
fire resistance
Opis:
In this article the effect of type and content of fractions of recycled glass fiber reinforced plastics (GFRP) on the mechanical properties and flame resistance of epoxy composites (EP) were investigated. For this purpose, post-production waste of glass fabric reinforced laminate with epoxy matrix containing 15 wt % of aluminum diethylphosphinate (AlDPi), 10 wt % of melamine polyphosphate (MPP) and 15 wt % of zinc borate (ZB) was ground and sieved to obtain four fractions of grain size: >1 mm (A), 1–0.5 mm (B), 0.25–0.5 mm (C) and <0.25 mm (D). The two smallest fractions (C, D) were used to prepare epoxy composites containing 10, 15 and 20 wt % of waste. The mechanical properties and fire resistance of obtained composites aimed as structural elements of seat equipment in public transport were determined. Scanning electron microscopy (SEM) was also performed to investigate the morphology of brittle fractures of epoxy composites. It was found that the amount and type of recyclated GFRP fraction affects the functional properties of powder-epoxy resin composites. The best results were obtained for the composite containing 15 wt % of the smallest fraction (D), as all mechanical properties were significantly improved [hardness 147.6 N/mm2 (+42.5%), impact strength 9.64 kJ/m2 (+11%), Young’s modulus 2.98 GPa (+41.5%), tensile strength 51.5 MPa (+37%) and flexural strength 98.7 MPa (+10.9%)]. On the other hand, significant decrease in mechanical properties was observed for the composite containing 20 wt % of the fractions with grain size 0.5–0.25 mm (C). The analysis of the brittle fractions morphology of composites, indicates the weak dispersion and agglomerates formation in the case of composites with coarse-grained fractions. This also contributed to the flammability results. The highest flame resistance was found in the composite with 20 wt % of the fine-grained fraction: limiting oxygen index LOI = 26.1% instead of 20.6% – EP, peak of heat release rate pHRR = 540.3 kW/m2 instead of 940.1 kW/m2 – EP.
Zbadano wpływ rodzaju oraz zawartości frakcji recyklatu laminatu z włóknem szklanym (GFRP) na właściwości mechaniczne oraz odporność na płomień kompozytów żywicy epoksydowej (EP). W tym celu zmielono odpady poprodukcyjne formatki fotela wykonanej z laminatu wzmocnionego tkaniną szklaną na osnowie żywicy epoksydowej, zawierającej 15% mas. dietylofosfinianu glinu (AlDPi), 10% mas. polifosforanu melaminy (MPP) oraz 15% mas. boranu cynku (ZB). Otrzymano cztery frakcje o wymiarach ziaren: >1 mm (A), 1–0,5 mm (B), 0,25–0,5 mm (C) oraz <0,25 mm(D). Dwie najdrobniejsze frakcje (C, D) wykorzystano do sporządzenia kompozytówepoksydowych zawierających 10, 15 i20% mas. odpadów. Oceniono właściwości mechaniczne oraz odporność na płomień otrzymanych materiałów pod kątem zastosowania ich jako elementy konstrukcyjne fotela w publicznych środkach transportu. Najlepsze wyniki uzyskano w wypadku kompozytu zawierającego 15% mas. frakcji D, znacznie poprawiły się: twardość – 147,6 N/mm2 (o 42,5%), udarność – 9,64 kJ/m2 (o 11%), moduł Younga – 2,98 GPa (o 41,5%), naprężenie rozciągające – 51,5 MPa (o 37%) oraz naprężenie zginające – 98,7 MPa (o 10,9%). Z kolei wyraźne pogorszenie właściwości mechanicznych zaobserwowano w wypadku kompozytu zawierającego 20% mas. frakcji o wymiarach ziaren 0,5–0,25 mm (C). Na podstawie wyników skaningowej mikroskopii elektronowej (SEM) morfologii kruchych przełomów otrzymanych kompozytów stwierdzono słabą dyspersję oraz powstawanie aglomeratów w kompozytach z frakcją gruboziarnistą, co miało również wpływ na palność badanych materiałów. Największą odpornością na płomień odznaczał się kompozyt zawierający 20% mas. frakcji D: indeks tlenowy LOI = 26,1% (w odniesieniu do wartości LOI żywicy epoksydowej 20,6%), maksymalna szybkość uwalniania ciepła pHRR = 540,3 kW/m2 (wporównaniu z pHRR żywicy EP – 940,1 kW/m2).
Źródło:
Polimery; 2020, 65, 4; 280-288
0032-2725
Pojawia się w:
Polimery
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Fire resistance assessment of the long-span steel truss girder
Ocena odporności ogniowej stalowej kratownicy o dużej rozpiętości
Autorzy:
Woźniczka, P.
Powiązania:
https://bibliotekanauki.pl/articles/231439.pdf
Data publikacji:
2020
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
odporność ogniowa
hala wielkokubaturowa
rozpiętość duża
pożar
analiza właściwości
fire resistance
large-space hall
long-span
fire
performance analysis
Opis:
The performance-based analysis of the large-space steel sports hall is presented. Load-bearing structure of the hall consists of spatial long-span truss girders that are made of modern square hollow sections. Both fire development analysis and mechanical response analysis are discussed in detail. Fire Dynamics Simulator and Safir programs are used. Main focus is put on the factors that could affect the final fire resistance of the structure. Uniform and non-uniform heating, different boundary conditions and local imperfections are taken into account. Structures with and without fireproof insulation are considered. Values of the critical temperature, failure modes and fire resistance estimated for various cases are presented. Computer simulations were carried out both for fire growth and decay phase. As a result it is clearly shown that some reductions of the required fireproof insulation are possible. Moreover, the structure without complete traditional fireproof insulation is able to survive not only the direct fire exposure but also the cooling phase.
Aktualne normy europejskie EN 1991-1-2 i EN 1993-1-2 dopuszczają do stosowania różnorodne metody oceny odporności ogniowej, które mogą być wykorzystane zarówno w odniesieniu do pojedynczych elementów jak i całych ustrojów nośnych. Podejście obliczeniowe bazujące na właściwościach danej strefy pożarowej (tzw. performance-based approach) powinno uwzględniać zarówno analizę rozwoju pożaru jak i odpowiedzi mechanicznej konstrukcji. Wykorzystanie tego typu metody może być szczególnie istotne w przypadku obiektów o stosunkowo dużych kubaturach stref pożarowych, takich jak na przykład wielkogabarytowe hale o konstrukcji stalowej. Możliwy jest wówczas nie tylko lepszy wgląd w zachowanie się konstrukcji w warunkach pożaru ale istnieje także możliwość dostosowania izolacji ogniochronnej do rzeczywistego zapotrzebowania. Jednocześnie przeprowadzenie kompletnych symulacji typu "performance-based" jest niezwykle czasochłonne oraz wymaga połączenia wiedzy z zakresu inżynierii pożarowej oraz inżynierii lądowej. Dodatkowo wpływ niektórych czynników (takich jak przykładowo lokalne imperfekcje łukowe) na prognozowaną odporność ogniową nie został do tej pory w pełni rozpoznany. W tej sytuacji w artykule przedstawiono opartą na charakterystyce danej strefy pożarowej analizę odporności ogniowej wielkogabarytowej hali sportowej o konstrukcji stalowej. Rozpatrywana hala charakteryzuje się zarówno znacznymi wymiarami w rzucie (70m x 60m) jak i stosunkowo dużą wysokością (16.5m). Główny ustrój nośny składa się z trójpasowych dźwigarów kratowych o rozpiętości 60m, rozmieszczonych w rozstawie co 6m. Obliczenia rozwoju pożaru wykonano za pomocą programu Fire Dynamics Simulator. Do opracowania analizy odpowiedzi mechanicznej konstrukcji wykorzystano program Safir.
Źródło:
Archives of Civil Engineering; 2020, 66, 2; 63-75
1230-2945
Pojawia się w:
Archives of Civil Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Full-scale fire resistance testing of concrete beams reinforced with various FRP reinforcement
Ognioodporność pełnowymiarowych belek betonowych zbrojonych prętami FRP o zróżnicowanym składzie
Autorzy:
Protchenko, K.
Urbański, M.
Powiązania:
https://bibliotekanauki.pl/articles/1849735.pdf
Data publikacji:
2020
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
polimer zbrojony włóknami
FRP
pręt FRP
zbrojenie hybrydowe
belka betonowa
odporność ogniowa
fibre reinforced polymer
FRP bar
hybrid reinforcement
concrete beam
fire resistance
Opis:
The widespread use of Fibre-Reinforced Polymers (FRP) reinforced concrete (RC) structural members is hindered by their low fire resistant characteristics, limiting their use to cases, where fire resistance is not a priority. Presented and discussed are experimental results pertaining to the flexural members subjected to heating and simultaneous loading. Solely non-metallic FRP bars: (i) Basalt FRP (BFRP), (ii) Hybrid FRP (HFRP) with carbon and basalt fibres and (ii) nano-Hybrid FRP (nHFRP) with modified epoxy resin, were used as internal reinforcement for beams. The destruction of the beams was caused in different ways, beams reinforced with BFRP bars were destroyed by reinforcement failure while those reinforced with hybrid FRP bars were destroyed by concrete crushing. The BFRP reinforced beams obtained a maximum temperature, measured directly on the bars, of 917°C, compared to beams reinforced with hybrid FRP bars, where the temperature on the bars reached 400-550°C at failure. Moreover, the highest registered ductility was obtained for BFRP reinforced beams as well, where the maximum deflections reached approximately 16 cm.
Degradacja nośności zbrojenia konstrukcji w postaci prętów FRP (ang. Fibre-Reinforced Polymers) może być spowodowane kilkoma czynnikami, do których należą: rodzaje włókien, osnowy (matrycy), ich objętościowy udział, sposób wytwarzania, jakość składników prętów. Jednakże głównym czynnikiem jest przede wszystkim wpływ temperatury w zbrojeniu FRP, występujący w trakcie oddziaływania warunków pożarowych. Zjawisko redukcji nośności konstrukcji i przyczepności zbrojenia do betonu pojawia się, gdy temperatura prętów FRP zbliża się do temperatury zeszklenia Tg osnowy (matrycy), której wartość zależy od rodzaju żywicy. Jednym z rozwiązań w tym zakresie jest zastosowanie większej otuliny lub zastosowanie dodatkowego systemu ochrony przeciwpożarowej. Jednak obecnie dostępne dane na temat zachowania elementów betonowych zbrojonych FRP w warunkach pożarowych, są ograniczone, szczególnie w odniesieniu do nośności belek po poddaniu ich oddziaływaniu wysokich temperatur. Dlatego odporność ogniowa elementów betonowych zbrojonych FRP jest jednym z podstawowych czynników, które utrudniają powszechne stosowanie tych materiałów jako alternatywy dla zbrojenia stalowego. W artykule opisano zachowanie się belek betonowych, zbrojonych prętami FRP wyprodukowanych na bazie włókien bazaltowych i węglowych, poddawanych testom odporności ogniowej. Badania belek narażonych na wysokie temperatury, przeprowadzono według scenariusz pożaru umownego zgodnie z krzywą standardową ISO-834 [13], [29]. Ponieważ głównym celem było zbadanie wpływu rodzaju zbrojenia FRP na odporność ogniową belek, zastosowano różne rodzaje prętów w strefie rozciągania (dolna część belek): (i) zbrojenie na bazie włókien bazaltowych BFRP (ang. Basalt FRP), (ii) hybrydowe zbrojenie HFRP (ang. Hybrid FRP) z włóknami węglowymi i bazaltowymi oraz (ii) nanohybrydowymi prętami nHFRP (ang. nano-Hybrid FRP) ze zmodyfikowaną żywicą epoksydową. Ponadto, badane elementy charakteryzowały się zmiennym stopniem zbrojenia, w celu określenia wpływu średnicy i liczby prętów na nośność belek podczas i po oddziaływaniu wysokich temperatur.
Źródło:
Archives of Civil Engineering; 2020, 66, 4; 119-136
1230-2945
Pojawia się w:
Archives of Civil Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Mechanical performance of FRP-RC flexural members subjected to fire conditions
Autorzy:
Protchenko, Kostiantyn
Elżbieta, Szmigiera
Urbański, Marek
Garbacz, Andrzej
Powiązania:
https://bibliotekanauki.pl/articles/391083.pdf
Data publikacji:
2020
Wydawca:
Politechnika Lubelska. Wydawnictwo Politechniki Lubelskiej
Tematy:
Fibre Reinforced Polymers (FRP) bars
Hybrid FRP bars
FRP-RC beams
Fire resistance of FRP
Fire resistance of FRP-RC members
Opis:
One of the main concerns that limit the widespread use of Fibre-Reinforced Polymers (FRP) bars as internal reinforcement for reinforced concrete (RC) structures is their relatively unexplored response to elevated temperatures. The behaviour of FRP reinforcement at elevated temperature as well as their post-fire behaviour can be different from conventional reinforcement and depends on the properties of the constituents of the bars. Therefore, the fire resistance of FRP-RC structures is an important issue that needs careful investigation before FRP reinforcement can be implemented in RC structures. The experimental results for full-scale FRP-RC beams subjected to specific fire action were presented and discussed in this paper. The specimens were exposed to heat in the mid-section from below (tension zone) and from the sides. As one of the main aims was to examine the influence of different reinforcement configurations, the testing was made for concrete beams reinforced with three different types of FRP bars: (i) basalt-FRP (BFRP), (ii) hybrid FRP with carbon and basalt fibres (HFRP) and (iii) nano-hybrid FRP (nHFRP), with modification of the epoxy matrix of the rebars. The present work describes the behaviour of FRP-RC beams exposed to fire conditions and simultaneous loading (50 % of their ultimate strength capacity at normal temperature) and unloaded beams were tested after the cooling phase in order to evaluate their residual resistance. Present work shows that the type of FRP bars used has a direct influence on the outcomes and the way of destruction. The maximum ductility, the longest heating time of approximately 100 minutes, was obtained for beams reinforced with BFRP bars and attained deflections were corresponded to the value of 162 mm.
Źródło:
Budownictwo i Architektura; 2020, 19, 4; 17-30
1899-0665
Pojawia się w:
Budownictwo i Architektura
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Projektowanie dużych ścian żelbetowych z uwagi na warunki pożarowe
Structural fire design of large RC walls
Autorzy:
Kowalski, Robert
Modzelewski, Robert
Powiązania:
https://bibliotekanauki.pl/articles/128634.pdf
Data publikacji:
2020
Wydawca:
PWB MEDIA Zdziebłowski
Tematy:
ściana żelbetowa
spalarnia odpadów
odporność ogniowa
projektowanie
warunki pożarowe
nośność ogniowa
metoda izotermy 500°C
żebro usztywniające
reinforced concrete wall
waste incineration plant
fire resistance
projects
fire conditions
fire load capacity
500 °C isotherm method
stiffening rib
Opis:
W referacie omówiono praktyczny przypadek zaprojektowania dużych ścian żelbetowych w spalarni odpadów, z uwagi na odporność ogniową, na bazie rozpatrywania pożaru jako wyjątkowej sytuacji projektowej. Zasadność takiego postępowania wynikała z faktu, że wykorzystanie prostych Danych tabelarycznych PN-EN 1992-1-2 prowadziło do rozwiązań niekorzystnych ekonomicznie. Po przeanalizowaniu nośności ogniowej konstrukcji za pomocą metody Izotermy 500°C oraz w wyniku zastosowania żeber usztywniających ściany znacznie zredukowano ich grubość.
This paper contains a case study of a fire design of large RC walls in a waste incineration plant. In the analysis fire was considered as an accidental design situation. This approach was necessary, because the standard analysis based on simplified Tabulated data given in EN 1992-1-2 has led to a design that was not economically feasible. The analysis of fire resistance of the structure by 500°C isotherm method together with the use of stiffening ribs, has allowed to significantly reduce the required wall thickness.
Źródło:
Builder; 2020, 24, 4; 45-47
1896-0642
Pojawia się w:
Builder
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Zastosowanie zaawansowanej metody oceny odporności ogniowej w budownictwie przemysłowym
Application of advanced fire resistance assessment method for industrial structures
Autorzy:
Woźniczka, Piotr
Powiązania:
https://bibliotekanauki.pl/articles/128943.pdf
Data publikacji:
2020
Wydawca:
PWB MEDIA Zdziebłowski
Tematy:
ocena odporności
odporność ogniowa
hala stalowa
symulacja
rozwój pożaru
odpowiedź mechaniczna
modelowanie konstrukcji
temperatura krytyczna
model zniszczenia
resistance assessment
fire resistance
steel hall
simulation
fire development
mechanical response
structure modelling
critical temperature
failure mode
Opis:
W artykule przedstawiono przykład opracowanej oceny odporności ogniowej obiektu przemysłowego. Dla rozpatrywanej hali maszynowni o konstrukcji stalowej zaprezentowano wyniki symulacji rozwoju pożaru oraz odpowiedzi mechanicznej konstrukcji. Obliczenia przeprowadzono za pomocą zaawansowanych programów komputerowych. Omówiono wpływ takich czynników, jak nierównomierne ogrzewanie oraz sposób modelowania konstrukcji na szacowaną odporność ogniową. Wskazano także wartości temperatury krytycznej oraz prognozowane modele zniszczenia. Wykazano, że omawiana metoda może być z powodzeniem stosowana w odniesieniu do rozpatrywanej kategorii obiektów.
Both fire development and mechanical response analysis of the steel turbine hall are described. Factors like non-uniform heating and way of structural modeling and their impact on the anticipated fire resistance of the structure are discussed. Moreover, values of the crictical temperature and predicted failure modes are given. As a result it is shown that described method is appropriate for the considered type of buildings.
Źródło:
Builder; 2020, 24, 4; 58-60
1896-0642
Pojawia się w:
Builder
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
An analysis of the resistance of an extended end-plate beam-to-beam connection subjected to tension in fire conditions
Autorzy:
Słowikowska, Alina
Polus, Łukasz
Powiązania:
https://bibliotekanauki.pl/articles/390133.pdf
Data publikacji:
2019
Wydawca:
Politechnika Lubelska. Wydawnictwo Politechniki Lubelskiej
Tematy:
beam-to-beam connection
fire resistance
steel joint
critical temperature
połączenie belka-belka
odporność ogniowa
złącze stalowe
temperatura krytyczna
Opis:
This paper presents an analysis of the fire resistance of a steel joint subject-ed to tension. The authors of this article used prescriptive rules and simple calculation models to present an impact of the value of the load on the fire resistance of the connection. Designers often evaluate the critical temperature and fire resistance time of steel elements. However, they neglect the evaluation of the above-mentioned values for steel connections. In this article a simple engineering method was used to calculate the fire resistance of the joint.
Źródło:
Budownictwo i Architektura; 2019, 18, 1; 81-88
1899-0665
Pojawia się w:
Budownictwo i Architektura
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Odporność betonu na pękanie w temperaturach pożarowych
Concrete resistance to cracking at fire temperatures
Autorzy:
Plechawski, Stanisław
Powiązania:
https://bibliotekanauki.pl/articles/160440.pdf
Data publikacji:
2019
Wydawca:
Polski Związek Inżynierów i Techników Budownictwa
Tematy:
beton
odporność
temperatura pożaru
pękanie
badanie
makrostruktura
mikroskop skaningowy
SEM
concrete
resistance
fire temperature
cracking
study
macrostructure
scanning microscope
Opis:
W artykule zostanie omówiony wpływ temperatur pożarowych na najważniejszy kompozyt cementowy, jakim jest beton. Badania własne wykazały, że uszkodzenia powstałe w stadium początkowego twardnienia kompozytów cementowych przed użytkowaniem, jak i w jego trakcie, propagują pod wpływem wysokich temperatur i wpływają na właściwości fizykochemiczne, strukturalne oraz mechaniczne tych kompozytów, a ich wielkość może być oceniana za pomocą krytycznego współczynnika intensywności naprężeń KIC, który jest miarą odporności na pękanie.
The aim of this article is to discuss the effect of fire temperatures on the most important cement composite, which is concrete. The author’s research has indicated that damage caused at the stage of initial hardening of cement composites before and during their use, propagates at high temperatures and affects the physicochemical, structural and mechanical properties of these composites, whereas their size can be assessed using the critical stress intensity factor KIC, which constitutes a measure of resistance to cracking.
Źródło:
Przegląd Budowlany; 2019, 90, 7-8; 90-96
0033-2038
Pojawia się w:
Przegląd Budowlany
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies