Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "fire detection" wg kryterium: Temat


Tytuł:
Image processing method for cargo container identification in a stack within the cargo temperature control and fire safety system on container ships
Autorzy:
Konon, Vladyslav
Powiązania:
https://bibliotekanauki.pl/articles/32920246.pdf
Data publikacji:
2023
Wydawca:
Politechnika Gdańska. Wydział Inżynierii Mechanicznej i Okrętownictwa
Tematy:
shipboard safety
cargo transportation
cargo temperature control
image processing
fire detection
Opis:
The current research is focused on the identification of cargo containers in a stack from their images in the infrared and visible spectra, in order to locate the container-origin of ignition within the cargo temperature control and fire safety system. The relevance of the topic is reinforced by the functional requirements for shipboard safety, which are embodied in Chapter II-2 of the Safety of Life at Sea (SOLAS) Convention, and demanded by the necessity of enhancing safety measures during cargo transportation by the world container fleet. The thermal imager’s field of view (FOV) and the coordinate dependencies between the object and its image have been studied and modelled, and an algorithm for fire detection has been defined within the scope of the current research in connection with the containers within the camera’s FOV. A corresponding verification has been carried out by means of simulation modelling using the Unity and C# programming language capabilities.
Źródło:
Polish Maritime Research; 2023, 2; 114-120
1233-2585
Pojawia się w:
Polish Maritime Research
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Koncepcja ochrony przeciwpożarowej na statku morskim towarowym Regalica
The concept of fire prevention on the Regalica cargo vessel
Autorzy:
Węglarz, Kamil Łukasz
Powiązania:
https://bibliotekanauki.pl/articles/2175578.pdf
Data publikacji:
2022
Wydawca:
Szkoła Główna Służby Pożarniczej
Tematy:
analiza bezpieczeństwa pożarowego
ochrona przeciwpożarowa
przepisy morskie
wymagania przeciwpożarowe
system sygnalizacji pożarowej
analysis of fire safety
fire prevention
maritime regulations
firefighting requirements
fire detection and alarm system
Opis:
W artykule opracowano koncepcję ochrony przeciwpożarowej statku towarowego Regalica. W części teoretycznej omówiono zagadnienia dotyczące regulacji prawnych ochrony przeciwpożarowej statków morskich oraz zaprezentowano charakterystykę statku Regalica. W części praktycznej dokonano opracowania projektu systemu sygnalizacji pożarowej na opisywanym masowcu w oparciu o przepisy morskie. Na etapie opracowywania projektu wykonano następujące założenia projektowe: opis techniczny przyjętej instalacji wykrywania pożaru, dobór elementów liniowych, prowadzenie linii dozorowych i dobór przewodów, lokalizacja centrali sygnalizacji pożarowej oraz warunki zasilania. Ponadto w tej części przedstawiono kompleksową koncepcję ochrony przeciwpożarowej. Na końcu sformułowano wnioski mające wpływ na proces projektowania systemów sygnalizacji pożarowej.
In this article a concept of fire protection of the Regalica cargo ship was developed. In the theoretical part the issues concerning the fire protection regulations for sea vessels were discussed and characteristic features of the Regalica ship were presented. The practical part consists of a plan of a fire alarm system on the described bulk carrier based on relevant maritime regulations. In the design development stage, the following design assumptions have been adopted: technical description of the approved fire detection system, selection of linear elements, routing of supervisory lines and selection of cables, location of the fire alarm control panel and power supply conditions. Furthermore, this section includes a comprehensive fire protection concept. The final part formulates conclusions that affect the design process of fire alarm systems.
Źródło:
Zeszyty Naukowe SGSP / Szkoła Główna Służby Pożarniczej; 2022, 81; 29--46
0239-5223
Pojawia się w:
Zeszyty Naukowe SGSP / Szkoła Główna Służby Pożarniczej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Fire Detection Methods Based on Various Color Spaces and Gaussian Mixture Models
Autorzy:
Munshi, Amr
Powiązania:
https://bibliotekanauki.pl/articles/2123292.pdf
Data publikacji:
2021
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
fire detection
fire pixels
fire-like pixels
color models
Gaussian mixture models
Opis:
Fire disasters are very serious problems that may cause damages to ecological systems, infrastructure, properties, and even a threat to human lives; therefore, detecting fires at their earliest stage is of importance. Inspired by the technological advancements in artificial intelligence and image processing in solving problems in different applications, this encourages adopting those technologies in reducing the damage and harm caused by fire. This study attempts to propose an intelligent fire detection method by investigating three approaches to detect fire based on three different color models: RGB, YCbCr, and HSV are presented. The RGB method is applied based on the relationship among the red, green and blue values of pixels in images. In the YCbCr color model, image processing and machine learning techniques are used for morphological processing and automatic recognition of fire images. Whereas for the HSV supervised machine learning techniques are adopted, namely decision rule and Gaussian mixture model (GMM). Further, the expectation maximization (EM) algorithm is deployed for the GMM parameters estimation. The three proposed models were tested on two data sets, one of which contains fire images, the other consists of non-fire images with some having fire-like colors to test the efficiency of the proposed methods. The experimental results showed that the overall accuracies on two data sets for the RGB, YCbCr, and HSV methods were satisfactory and were efficient in detecting outdoor and indoor fires.
Źródło:
Advances in Science and Technology. Research Journal; 2021, 15, 3; 197--214
2299-8624
Pojawia się w:
Advances in Science and Technology. Research Journal
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Detekcja dymu w wielkokubaturowych obiektach infrastruktury transportowe
Fire detection in large-volume transport infrastructure objects
Autorzy:
Klimczak, Tomasz
Powiązania:
https://bibliotekanauki.pl/articles/312005.pdf
Data publikacji:
2019
Wydawca:
Instytut Naukowo-Wydawniczy "SPATIUM"
Tematy:
czujka pożarowa
czujki liniowe dymu
czujki zasysające
wideo detekcja pożaru
detekcja dymu
system sygnalizacji pożarowej
fire detector
smoke line detector
aspiration smoke detector
video fire detection
smoke detection
fire alarm system
Opis:
W artykule omówiono urządzenia (podzespoły wchodzące w skład systemu sygnalizacji pożarowej) służące do detekcji dymu, które można zastosować w celu zapewnienia bezpieczeństwa pożarowego wielkokubaturowych obiektów transportowych. W artykule omówiono zarówno powszechnie stosowane punktowe czujki dymu, czujki liniowe dymu, jak również bardziej zaawansowane technologicznie aspiracyjne czujki dymu (czujki zasysające) oraz czujki wykorzystujące nowoczesne technologie związane z wideo detekcją. Omówiono ponadto praktyczne możliwości w zastosowaniu konkretnych rozwiązań oraz ograniczenia w ich stosowaniu. Zaznaczono kierunki rozwoju systemów sygnalizacji pożarowej, w tym w zakresie detekcji dymu.
The article discusses the possible types of smoke detection devices that can be used to provide fire safety for large volume transport facilities. The article discusses both commonly used point smoke detectors or line detectors, as well as more technologically advanced aspiration smoke detectors (aspiration detectors) and detectors using video detection. Practical possibilities in the application of specific solutions and limitations in their application were also discussed. Development directions of fire alarm systems producers, including smoke detection, have been marked.
Źródło:
Autobusy : technika, eksploatacja, systemy transportowe; 2019, 20, 12; 50-54
1509-5878
2450-7725
Pojawia się w:
Autobusy : technika, eksploatacja, systemy transportowe
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Fire safety instructions as a tool supporting rescue operations in workplaces
Autorzy:
Jędrzejas, Natalia
Powiązania:
https://bibliotekanauki.pl/articles/1166992.pdf
Data publikacji:
2018
Wydawca:
Przedsiębiorstwo Wydawnictw Naukowych Darwin / Scientific Publishing House DARWIN
Tematy:
fire detection
fire safety instructions
internal fire
rescue operations
support tools
Opis:
Fire safety instruction is an integral part of the safety of people staying in the building in case of fire. Created in accordance with the Regulation of the Minister of Internal Affairs and Administration of 7 June 2010, the Ministry of Interior and Administration regarding fire protection of buildings, other construction objects and sites and implemented in the building for which it was developed is a helpful tool that can significantly affect the effectiveness and safety of emergency operations.
Źródło:
World Scientific News; 2018, 105; 110-121
2392-2192
Pojawia się w:
World Scientific News
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Economic justification for the new approach of using videobased smoke detection with the aim of decreasing total costs incurred by the untimely detection of fires on ships
Autorzy:
Bistrović, M.
Ristov, P.
Powiązania:
https://bibliotekanauki.pl/articles/135234.pdf
Data publikacji:
2017
Wydawca:
Akademia Morska w Szczecinie. Wydawnictwo AMSz
Tematy:
fire alarm
video technology
computer vision
video detection
smoke detectors
ships
Opis:
Although various methods of using new techniques and technologies in ship fire alarm systems have been developed to date, some of which have made significant improvements in the functioning of such systems, in practice there is still plenty of room for further research regarding the operational efficiency of ship fire alarm systems and its impact on crew, passenger and overall ship safety. The application of electronic and computer technologies enables the development of intelligent solutions to improve the efficiency of ship fire alarm systems. Besides the economic justification, this paper presents a comparative analysis of classical and modern approaches based on video detection and computer vision in the detection of early phase smoke as a precursor to fire incidents. The economic justification of the new approach is concerned with decreasing the costs incurred by the untimely detection of the early stages of fire in ship engine rooms.
Źródło:
Zeszyty Naukowe Akademii Morskiej w Szczecinie; 2017, 51 (123); 21-27
1733-8670
2392-0378
Pojawia się w:
Zeszyty Naukowe Akademii Morskiej w Szczecinie
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
History of the application of thermovision in the fire protection system in Poland
Autorzy:
Szajewska, A.
Rybiński, J.,
Powiązania:
https://bibliotekanauki.pl/articles/973074.pdf
Data publikacji:
2017
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
fire detection
pyrometer
thermal imaging camera
fireman
firefighting
temperature
Opis:
The paper presents the most important events in the history of the development of the thermovision usage in Fire Services in Poland. The first attempts to use the thermal imaging cameras in fire protection in Poland and in the world have been described. Firefighting and Rescue Units were first equipped with thermal cameras for tactical operations in 1997. In the following years the Fire Service Units were continuously provided with more thermal equipment. Attempts have been made to use infrared pyrometers to detect fires. The paper also presents the current state of thermal imaging cameras equipment in Fire Services and information how the cameras are used. In order to present the usage of cameras in the actions of Fire Services, the statistics on thermal devices contribution in actions in the selected poviat has been drawn up. The data are presented in Table 1 and Table 2. The final conclusions show the directions for development of the thermovision usage in fire protection and rescue actions.
Źródło:
Measurement Automation Monitoring; 2017, 63, 4; 124-127
2450-2855
Pojawia się w:
Measurement Automation Monitoring
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Problems with Integrating the IKZ-02P IFF Interrogator with the JODEK-SP Air Defence Gun and Rocket Artillery System
Problemy integracji interrogatora IFF IKZ-02P z przeciwlotniczym zestawem rakietowo-artyleryjskim JODEK-SP
Autorzy:
Dobrzyński, P.
Kołakowski, A.
Śmietański, W.
Powiązania:
https://bibliotekanauki.pl/articles/403330.pdf
Data publikacji:
2017
Wydawca:
Wojskowa Akademia Techniczna im. Jarosława Dąbrowskiego
Tematy:
anti-aircraft defence
radioelectronic detection
fire control systems
obrona przeciwlotnicza
rozpoznanie radioelektroniczne
system kierowania ogniem
Opis:
The objective of integrating the IKZ-02P identification friend-or-foe interrogator with the ZUR-23-2SP air defence gun and rocket artillery system (henceforth “ADGRAS”), codename “JODEK-SP”, was to provide the latter with a novel functionality consisting of locking out the ADGRAS every time the IFF interrogation returned "friend" for aircraft operating in the operating range of the ADGRAS deployed to effect anti-aircraft defence at air bases. This paper presents the conclusions from an analysis of interface cooperation of the IKZ-02P IFF interrogator system and the JODEK-SP ADGRAS, complete with results of an experimental verification applied to validate the solutions applied to integrate both systems.
Celem integracji interrogatora “swój-obcy” z przeciwlotniczym zestawem rakietowo-artyleryjskim ZU-23-2SP kryptonim JODEK-SP było uzyskanie nowej funkcjonalności, jaką jest automatyczne blokowanie systemu broni w wyniku interrogacji przynależności statków powietrznych realizujących zadania w strefie działania zestawu przeciwlotniczego będącego efektorem systemu osłony bazy lotniczej. Artykuł zawiera wnioski z analizy współpracy obydwu systemów, a także wyniki doświadczalnej weryfikacji, których zadaniem było sprawdzenie poprawności zastosowanych rozwiązań.
Źródło:
Problemy Mechatroniki : uzbrojenie, lotnictwo, inżynieria bezpieczeństwa; 2017, 8, 3 (29); 43-56
2081-5891
Pojawia się w:
Problemy Mechatroniki : uzbrojenie, lotnictwo, inżynieria bezpieczeństwa
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wpływ prędkości przepływu powietrza na czas zadziałania czujek zasysających dymu
Impact of Air Flow Velocity on Response Time of Smoke Detectors
Autorzy:
Wnęk, W.
Dubicki, J.
Mostowik, N.
Powiązania:
https://bibliotekanauki.pl/articles/136629.pdf
Data publikacji:
2016
Wydawca:
Szkoła Główna Służby Pożarniczej
Tematy:
system sygnalizacji pożarowej
czujki działające z wykorzystaniem światła rozproszonego
czujki działające z wykorzystaniem światła przechodzącego lub jonizacji
czujki zasysające
cząstki dymu
fire detection and fire alarm system
detectors using scattered light
detectors using transmitted light or ionization
aspirating smoke detectors
smoke particles
Opis:
W artykule podjęto się analizy wpływu przepływu powietrza na czas zadziałania czujek zasysających dymu. Omówiono stanowisko pomiarowe wykonane na podstawie norm do badania czujek pożarowych dymu. Zbadano wpływ prędkości przepływu mieszaniny powietrzno-dymowej na rozkład cząstek dymu. Dokonano porównania wpływu prędkości przepływu na czas zadziałania czujek jonizacyjnych, optycznych rozpraszających do czujek zasysających. Badania wykonano dla spalania płomieniowego i bezpłomieniowego. Sformułowano wnioski mające wpływ na proces projektowania systemów zabezpieczeń.
The paper contains an analysis of impact of air flow velocity on response time of aspirating smoke detectors. A measurement appliance, constructed on the basis of standards for fire smoke sensors testing, has been described. The impact of flow velocity of air and smoke mixture on the smoke particles distribution was tested. A comparison of impact of flow velocity on the response time of dispersion optical, ionization detectors and aspirating smoke detectors was performed. The research was performed for flame and flameless combustion. The conclusions , having impact on the protection systems design, were formulated.
Źródło:
Zeszyty Naukowe SGSP / Szkoła Główna Służby Pożarniczej; 2016, 3, 59; 5-19
0239-5223
Pojawia się w:
Zeszyty Naukowe SGSP / Szkoła Główna Służby Pożarniczej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wpływ pyłów pochodzenia drzewnego na działanie czujek pożarowych dymu
Influence of Wooden-Based Dusts on Smoke Fire Detectors
Autorzy:
Wnęk, W.
Jargieło, M.
Porowski, R.
Powiązania:
https://bibliotekanauki.pl/articles/373369.pdf
Data publikacji:
2016
Wydawca:
Centrum Naukowo-Badawcze Ochrony Przeciwpożarowej im. Józefa Tuliszkowskiego
Tematy:
systemy sygnalizacji pożarowej
czujki dymu
fałszywe alarmy
pył drzewny
fire detection systems
smoke detectors
false alarms
wooden dust
Opis:
Cel: Obecnie poszukuje się rozwiązań w zakresie czujek pożarowych dymu, które nie będą wrażliwe na sygnały zwodnicze powodujące fałszywe alarmy pożarowe central sygnalizacji pożarowej. Jednym z takich sygnałów jest występujący w pomieszczeniach pył drzewny traktowany przez czujkę jako dym o dużych cząstkach. W artykule opisano wykonane badania wybranych czujek dymu dla różnych pyłów drzewnych. Celem podstawowym artykułu jest wybór najbardziej odpornej czujki dymu na cząstki pyłu, bez pogorszenia jej właściwości detekcyjnych. Wprowadzenie: Podczas projektowania instalacji systemów sygnalizacji pożarowej napotyka się na problemy doboru czujek pożarowych pracujących w otoczeniu różnych zakłóceń powodujących fałszywe alarmy. Początkowo zbadano wpływ pyłu celulozowego wytwarzanego przy produkcji czasopism w jednej z drukarni. Następnie przeanalizowano również wpływ innych pyłów. Przy pomiarach mieszaniny cząstek o różnych wielkościach nie można jednoznacznie ocenić ich wpływu na sposób wykrywania. W związku z tym dokonano podziału pyłu ze względu na wielkość jego cząstek na pył o średnicach 100 μm, 200 μm i 500 μm. Pozwoliło to na zbadanie wpływu nie tylko rodzaju drewna, ale także wielkości cząstek pyłu na zadziałanie czujek. Metodologia: W trakcie badań opracowano metodę pomiaru wpływu pyłu na zadziałanie czujek. Dobrano ciśnienie sprężonego powietrza na poziomie 1,5 bar wraz z czasem otwarcia zaworu butli ze sprężonym powietrzem tak, aby osiągnąć najlepsze rozprowadzenie pyłu w pomieszczeniu badawczym. Za krótki czas otwarcia zaworu powodował pozostawanie pyłu w pojemniku, za długi powodował natomiast rozdmuchiwanie obłoku pyłu. W kilku próbach jako optymalny czas przyjęto 3 s. Czujki umieszczono umieszczono pryzmatycznie na przeciwległych ściankach pod sufitem komory w układzie nadajnik-odbiornik, nadajnik-lusterko. Wyniki pomiarów były rejestrowane za pomocą układu komputerowego. Wnioski: W wyniku przeprowadzonych badań, z uwzględnieniem zachowania czujek pożarowych dymu, określono rozwiązanie konstrukcyjne w postaci czujki systemu OSID jako czujki, która najlepiej poradziła sobie z pyłem występującym w zabezpieczanych pomieszczeniach. Jest to spowodowane sposobem obróbki sygnału w czujce. Na zadziałanie miały wpływ wielkość pyłów oraz, w mniejszym stopniu, rodzaj pyłu w odniesieniu do gatunku badanego drewna.
Aim: There is a need of fire detection solutions which are sensitive to deceptive signals. They can lead to false fire alarms. One of such signals is the activation of detectors in case of wooden dusts accumulated in the protected area which is regarded by the detector as smoke with large particles. This paper describes selected experimental results on various detectors and different wooden dusts. The aim of this project is to select a detector that is highly resistant to dust particles. Introduction: During designing fire detection systems there is always a problem in a proper selection of fire detectors operating in environments where there are various sources of false alarms. Initially, the influence of cellulose dusts as could be observed during the production of newspapers at the printing house was studied. Then the influence of other dusts was analyzed. During the measurement of smoke particles of different sizes the influence of particles on the detection cannot be explicitly determined. Due to this fact, tested dust was divided taking into consideration the size of the particles where the diameter was 100 μm, 200 μm and 500 μm. It made it possible to test the influence on the operation of the detectors of not only wooden-based materials but also of the size of dust particles. Methodology: During the tests the methodology of measuring the influence of dust on the activation time of detectors was prepared. The pressure of the compressed air was set at 1,5 bars together with the opening time of the valve of the compressed air container in order for the dust to be emitted evenly in the test chamber. If the valve opening time was too short, the dust remained in the container. If it was too long – the dust was blown all over the chamber. The optimum time was set as 3 s. Tested detectors were located by the ceiling of the chamber in the following manner: transmitter-receiver, transmitter-prismatic mirror on opposite walls. Measurement results were registered using a computer system. Conclusions: As a result of the conducted tests, which included the behaviour of fire detectors smoke, the best design solution was determined that best coped with duste present in protected areas. It is OSID smoke detection system. It is a result of how the signal was processed by the detector. The size of dust particles and, to a smaller degree, type of dust with respect to the tested species of wood influenced the operation of the smoke detector.
Źródło:
Bezpieczeństwo i Technika Pożarnicza; 2016, 42, 2; 43-55
1895-8443
Pojawia się w:
Bezpieczeństwo i Technika Pożarnicza
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wpływ rodzaju drewna na czas działania liniowych czujek dymu
The Influence of Wood Type on the Response Time of Optical Beam Smoke Detectors
Autorzy:
Porowski, R.
Janik, N.
Wdowiak, T.
Wnęk, W.
Powiązania:
https://bibliotekanauki.pl/articles/373335.pdf
Data publikacji:
2016
Wydawca:
Centrum Naukowo-Badawcze Ochrony Przeciwpożarowej im. Józefa Tuliszkowskiego
Tematy:
czujki liniowe dymu
spalanie drewna
detekcja pożaru
optical beam smoke detectors
wood combustion
fire detection
Opis:
Cel: Celem artykułu jest przeprowadzenie badań doświadczalnych dla dwóch wybranych liniowych czujek dymu, czujki OSID oraz DOP 6001 w zakresie czasów zadziałania w zależności od rodzaju spalanego drewna oraz spalania bezpłomieniowego i płomieniowego. Wprowadzenie: Na przestrzeni lat opracowano wiele typów czujek pożarowych różniących się zasadą działania. Najprostsze z nich to nieskomplikowane czujniki temperatury, najpierw mechaniczne, później, wraz z rozwojem techniki elektroniczne. Zdawano sobie sprawę, że nie wykrywają one zagrożenia dostatecznie szybko, dlatego też poszukiwano rozwiązań, które reagowałyby na pierwsze oznaki rozwijającego się pożaru. Punktowe czujki dymu są łatwe w montażu i obsłudze, gdyż są kompletnym, samowystarczalnym urządzeniem. Ich skuteczność maleje wraz z oddalaniem się źródła dymu od miejsca montażu czujki. W niektórych budynkach, jak np. duże hale magazynowe czy fabryki, dla zachowania odpowiedniego stopnia ochrony należałoby instalować setki czujek punktowych, aby ich zasięg skutecznego działania pokrył całą powierzchnię pomieszczenia. W takiej sytuacji lepszym rozwiązaniem są optyczne liniowe czujki dymu, które w zależności od gęstości ich instalacji, mogą pod względem powierzchni dozorowej zastąpić nawet 20 czujek punktowych. Metodologia: Artykuł został opracowany na podstawie przeprowadzonych badań doświadczalnych w komorze badawczej, przy wykorzystaniu różnych źródeł spalania bezpłomieniowego i płomieniowego. Wnioski: W próbach ze spalaniem bezpłomieniowym dym zaczynał się wydzielać niezwłocznie po umieszczeniu drewna na płycie grzewczej, proces tlenia się drewna był jednostajny. Przebieg parametrów pracy czujek w czasie jest w dużym przybliżeniu liniowy, co oznacza jednostajne tempo zmniejszania się przezroczystości powietrza w komorze badawczej. Spalanie płomieniowe rozpoczyna się od małego płomienia podpalonego alkoholu, który musi zainicjować spalanie drewna. Szybkość spalania, a co za tym idzie ilość wydzielanego dymu, cały czas rośnie, co powoduje zbliżony do wykładniczego przebieg parametrów pracy czujek w czasie. Tłumienie wiązek światła wysyłanych przez nadajnik czujki OSID, przebiega różnie, w zależności od typu spalania. Dym pochodzący ze spalania bezpłomieniowego początkowo tłumi obie wiązki jednakowo, dopiero po czasie pojawia się różnica pomiędzy tłumieniem UV a IR. Podczas spalania płomieniowego różnica jest widoczna natychmiast i wyraźnie powiększa się wraz z rozwojem pożaru testowego.
Aim: The aim of this paper is to carry out an experimental test of the influence of wooden materials on the activation time of two types of optical beam smoke detectors – the OSID and the DOP 6001 – during flaming and non-flaming combustion. Introduction: Over the years, there have been many types of fire detector that differ in the way they operate. A few years ago, it was discovered that many detector types depended on the operation principle. The simplest detectors were temperature detectors, at first mechanical, and then, with the development of technology, also electronic. It was obvious that they did not detect the threat fast enough, so it was essential to find solutions that would respond to the first signs of a developing fire. Spot-type smoke detectors are easy to install and use because they are a complete, self-contained devices. Their effectiveness decreases as the distance between the source of combustion and the location of smoke detectors grows. In some buildings, e.g. large warehouses or industrial plants, for a better fire-safety level, there is a need to install dozens of spot-type smoke detectors to protect large areas. In such cases optical beam smoke detectors could be the best practical solution. Methodology: The article is based on a series of experimental tests in a test chamber with various sources of flaming and non-flaming combustion. Two different types of optical beam smoke detectors were used to test the influence of wooden beams on activation times. Conclusions: During the experiments with non-flaming combustion, intense smoke production started immediately after the initiation of the combustion process. The non-flaming phenomenon was a very stable process for all kinds of tested wood. The activation-time results of optical beam smoke detectors and the evolution of the operational parameters, which was almost linear, indicate that these types of detectors are more effective for non-flaming combustion, as opposed to flaming combustion. Flaming combustion starts with a small flame of burning alcohol, which can initiate the combustion of wood. The burning rate and the intensity of smoke production increased, causing a linear evolution of operation parameters from tested smoke detectors over time. The suppression of light beams emitted by the transmitter of the OSID detectors shows different evolution depending on the type of combustion. Smoke production from non-flaming combustion initially suppresses both light beams. After some delay, the effect of the differences between UV and IR suppression is observed. During flaming combustion, the difference is immediately apparent and clearly increases with the development of the test fire.
Źródło:
Bezpieczeństwo i Technika Pożarnicza; 2016, 44, 4; 67-82
1895-8443
Pojawia się w:
Bezpieczeństwo i Technika Pożarnicza
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Zastosowanie nanotechnologii w ochronie przeciwpożarowej
The Application of Nanotechnology in Fire Protection
Autorzy:
Łukaszczuk, P.
Powiązania:
https://bibliotekanauki.pl/articles/373876.pdf
Data publikacji:
2016
Wydawca:
Centrum Naukowo-Badawcze Ochrony Przeciwpożarowej im. Józefa Tuliszkowskiego
Tematy:
ochrona przeciwpożarowa
nanotechnologia
uniepalniacze
środki gaśnicze
nanorurki
grafen
detekcja
fire protection
nanotechnology
flame retardants
extinguishing agents
nanotubes
graphene
detection
Opis:
Cel: Od czasu oswojenia ognia ludzkość boryka się z szeregiem niebezpieczeństw wynikających z niekontrolowanego procesu spalania. Na przestrzeni lat tworzono nowe zabezpieczenia przeciwpożarowe oraz udoskonalano istniejące rozwiązania. Celem artykułu jest przybliżenie czytelnikom tematyki nanotechnologii oraz korzyści, jakie płyną z zastosowania jej w inżynierii bezpieczeństwa w ochronie przeciwpożarowej. Wprowadzenie: Nanotechnologia jest młodą dziedziną nauki, która daje ogromne możliwości w modyfikowaniu właściwości fizykochemicznych materiałów oraz pozwala na tworzenie nowych, nieosiągalnych dotąd struktur o niespotykanych wcześniej właściwościach. Dzięki temu istnieją realne perspektywy zastosowania jej w jednym z najistotniejszych aspektów ludzkiego życia, czyli w bezpieczeństwie pożarowym. W artykule omówiono modyfikacje właściwości konwencjonalnych materiałów nanostrukturami w celu zwiększenia ich odporności termicznej. Przedstawiono także potencjał zastosowania osiągnięć nanotechnologii w detekcji wczesnych oznak pożaru, tj. dymu i gazów pożarowych. W ostatniej części artykułu zaprezentowano nowoczesne środki gaśnicze na bazie nanokrystalitów i mikrokapsułek oraz omówiono korzyści, jakie płyną z ich zastosowania. Metodologia: Artykuł został podzielony na sekcje odpowiadające trzem aspektom ochrony przeciwpożarowej. Do głównych wyzwań ochrony przeciwpożarowej należą kolejno: • modyfikacja szeroko stosowanych polimerów, których właściwości pożarowe nadal nie gwarantują bezpieczeństwa podczas pożaru, w celu uodpornienia ich na działanie ognia oraz zmniejszenia stwarzanego przez nie zagrożenia (np. eliminację opadu kroplistego termoplastów) poprzez zastosowanie nanowypełniaczy, • skuteczna detekcja wczesnych oznak powstawania pożaru np. dymu, tlenku węgla i innych specyficznych dla spalania cząsteczek, • wydajna metoda gaszenia pożaru, która nie zagraża życiu i zdrowiu ludzkiemu i nie niszczy obiektu i jego wyposażenia. • W artykule skupiono się na każdym z wymienionych powyżej aspektów i przedstawiono, jakie są możliwości zastosowania osiągnięć nanotechnologii w pożarnictwie. Wnioski: Wykazano, że czujki pożarowe na bazie nanomateriałów pozwalają na zwiększenie ich progu detekcji oraz żywotności. Jednocześnie duża wydajność w stosunku do masy pozwala zredukować koszty produkcji detektorów. Opisana w literaturze modyfikacja polimerów nanocząstkami pozwoliła na zmniejszenie zagrożenia, jakie niesie za sobą stosowanie tworzyw sztucznych. Wytwarzane kompozyty charakteryzują się zredukowaną ilością wydzielanego ciepła podczas spalania oraz lepszymi właściwościami reologicznymi w warunkach pożaru, dzięki czemu ich rozkład termiczny przebiega w kierunku zwęglania, co skutecznie redukuje niebezpieczeństwo tworzenia się palących kropli.
Aim: Since the time humans learned how to use a fire, people had to cope with a number of dangers resulting from an uncontrolled combustion process. Over the years new fire protection techniques and improvements were developed. The purpose of this article is to familiarize readers with the topic of nanotechnology and highlight the benefits of this technique in relation to fire safety. Introduction: Nanotechnology is an innovative field of science which offers major opportunities in modifying the physicochemical properties of materials and allows for the creation of new structures with remarkable properties, not encountered previously. Such achievements will allow for the utilisation of new approaches in one of the most important and oldest aspects of human life – fire safety. This article examines the modification potential of conventional material properties with nanostructures in order to increase their resistance to fire. Furthermore, the article illustrates potential application of nanotechnology developments in the early detection of fires through symptoms, such as smoke and presence of fire gases. Finally, the article explores benefits of modern extinguishing agents based on nanocrystallites and microcapsules. Methodology: The article is divided into sections, which represent the three aspects of protection from fires. The main challenges for fire safety include: • modification of widely used thermoplastic polymers, where the properties still do not guarantee safety when exposed to high temperature and intense heat flux - use of nanofillers will improve the resistance to fire action and reduce associated risks (e.g. elimination of the melting behaviour of thermoplastics exposed to fire), • effective detection of early signs of fire, e.g. smoke, carbon monoxide and other combustion-specific molecules, • efficient method of fire dousing, which is less health and life threatening and non-destructive to property and equipment. The article provides a focus on each of these aspects and demonstrates nanotechnology application potential in firefighting. Conclusions: The article reveals that the use of nanomaterials in sensors can increase detection parameters and extend the life of detectors. Simultaneously, efficiency increases in respect of volume can reduce production costs. Modification of polymer nanoparticles, described in the literature, allows for the reduction of fire hazards attributed to use of plastics. New generation of polymer composites exhibit a reduced level of heat release during combustion and demonstrate improved rheological properties in fire conditions. Consequently, the thermal decomposition process leading towards carbonization effectively eliminates melting during combustion.
Źródło:
Bezpieczeństwo i Technika Pożarnicza; 2016, 42, 2; 95-102
1895-8443
Pojawia się w:
Bezpieczeństwo i Technika Pożarnicza
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Mining waste dumps – modern monitoring of thermal and gas activities
Zwałowiska odpadów wydobywczych – nowoczesne metody monitoringu termiczno-gazowego
Autorzy:
Wasilewski, S.
Skotniczny, P.
Powiązania:
https://bibliotekanauki.pl/articles/216043.pdf
Data publikacji:
2015
Wydawca:
Polska Akademia Nauk. Instytut Gospodarki Surowcami Mineralnymi i Energią PAN
Tematy:
mining waste dump
remote measurement
temperature distribution
thermographic image
aircraft
fire detection
thermal activity
gas activity
zwałowisko odpadów wydobywczych
zdalny pomiar
rozkład temperatur
termografia
pokład samolotu
pożar zwałowiska
monitoring termiczno gazowy
Opis:
Mining waste dumps are permanently incorporated in the landscape of the mining areas and exert an impact on the environment in many ways. The presence in the massif of a dump of carbonaceous substances often leads to the formation of fire hazards.Monitoring the activity of a newly created coal waste dump or of one under fire plays an extremely important role in fire prevention activity. Under the current regulations it must be carried out both during the exploitation process and for many years after wards. Monitoring a dump is targeted, among others, at detecting thermal and gas anomalies already at the initial stage of development and to undertake preventive measures to eliminate and minimize the impact and load of a dump for the environment and the health and life of humans. In the article selected results of a research project (Raport 2011) are shown; a method of monitoring fire hazards at dump wastes was proposed, which includes thermal scanning and thermal-gas monitoring by a borehole method aimed at fixed points in the dump. Monitoring the large area of a dump requires exploration of the thermal state of a significant area hence the accepted scanning of the area is with a precision thermal imaging camera during an air raid. Then at selected sites of the dump, long-term in-field studies were conducted using the wireless data collection system from scattered test holes, made of perforated pipes and equipped with temperature and gas probes (CO, CO2, O 2). At the same time the changes of environmental conditions and changes in atmospheric state parameters were observed around the dump, the so-called wind rose, based on data recorded by the weather station.
Zwałowiska odpadów wydobywczych wpisują się na trwałe w krajobraz terenów górniczych i oddziaływają na środowisko naturalne w wielu aspektach. Obecność w masywie zwałowiska substancji węglowych prowadzi często do powstawania zagrożeń pożarowych. Niezwykle ważną rolę w profilaktyce przeciwpożarowej odgrywa monitoring aktywności zwałowiska odpadów węglowych nowo powstałych i zapożarowanych. Zgodnie z obowiązującymi przepisami musi on być prowadzony zarówno w czasie eksploatacji jak i przez wiele lat po jej zakończeniu. Monitoring zwałowiska ma na celu m.in. wykrycie anomalii termicznych i gazowych już w początkowym stadium rozwoju i podjęcie działań profilaktycznych w celu usunięcia i minimalizacji wpływu oraz obciążenia zwałowiska dla środowiska oraz zdrowia i życia ludzi. W artykule przedstawiającym wybrane wyniki projektu badawczego (Raport 2011) zaproponowano metodę monitoringu zagrożeń pożarowych zwałowiska odpadów powęglowych, która obejmuje skaning termiczny oraz monitoring termiczno-gazowy metodą otworową w ustalonych punktach zwałowiska. Monitoring rozległego zwałowiska wymaga rozpoznania stanu termicznego znacznego obszaru, stąd przyjęto skanowanie terenu za pomocą precyzyjnej kamery termowizyjnej w czasie przelotu lotniczego. Następnie w wyznaczonych miejscach zwałowiska prowadzono długookresowe badania poligonowe z wykorzystaniem bezprzewodowego systemu zbierania danych z rozproszonych otworów badawczych, wykonanych z rur perforowanych i wyposażonych w sondy z czujnikami temperatury i gazów (CO, CO2, O2). Równocześnie obserwowano zmienne warunki otoczenia i zmiany parametrów stanu atmosfery, tzw. róży wiatrów, wokół zwałowiska na podstawie danych zarejestrowanych przez stację pogodową.
Źródło:
Gospodarka Surowcami Mineralnymi; 2015, 31, 1; 155-181
0860-0953
Pojawia się w:
Gospodarka Surowcami Mineralnymi
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
From Concept Design to Validation and Verification: Case Study of a Modern and Integrated Fire Protection System for Application on Rolling Stock
Od projektu studyjnego do walidacji i weryfikacji: analiza przypadku dla nowoczesnego i zintegrowanego układu ochrony przeciwpożarowej do zastosowań w taborze kolejowym
Autorzy:
Barbagli, M.
Powiązania:
https://bibliotekanauki.pl/articles/215271.pdf
Data publikacji:
2014
Wydawca:
Instytut Kolejnictwa
Tematy:
fire protection
fire detection
firefighting
fire safety
rolling stock
design
water mist
aerosol
gas
nitrogen
ochrona przeciwpożarowa
wykrywanie pożaru
zwalczanie pożaru
bezpieczeństwo pożarowe
tabor kolejowy
projekt
mgła wodna
gaz
azot
Opis:
The paper investigates the design and development of a modern fire protection system for rolling stock application, based on case studies taken from the author’s real experience in project management of several fire protection systems all over the world.
W artykule przeanalizowano projekt i realizację nowoczesnego układu ochrony przeciwpożarowej dla taboru kolejowego. Wykorzystano analizy przypadków zaczerpnięte z praktyki zawodowej autora w zarządzaniu projektami wielu układów ochrony przeciwpożarowej na całym świecie.
Źródło:
Problemy Kolejnictwa; 2014, 164; 7-20
0552-2145
2544-9451
Pojawia się w:
Problemy Kolejnictwa
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Integration of rail vehicle devices into one module in order to increase passenger safety and comfort
Autorzy:
Hejczyk, T.
Wszołek, B.
Gałuszka, A.
Powiązania:
https://bibliotekanauki.pl/articles/393623.pdf
Data publikacji:
2014
Wydawca:
Polskie Stowarzyszenie Telematyki Transportu
Tematy:
passenger railway traffic
safety
collision detection module
fire alarm module
rail
crossing monitoring
ultrasonic method
radar
pasażerski ruch kolejowy
bezpieczeństwo
moduł wykrywania kolizji
moduł alarmu pożarowego
kolej
monitoring skrzyżowania
metoda ultradźwiękowa
Opis:
This paper presents an overview of collision and other threats (like e.g. rail crossing accidents) detection methods in railway passenger traffic. This overview leads to concept of Integrated System of Supporting Information Management in Passenger Traffic (the polish acronym of the system is ZSIKRP Demonstrator+). Currently on the polish and, as far as we know, international market such integrated solution is not developed and proposed. In this concept the final customer, e.g. the manufacturer or carrier company, will install one complete solution instead of multiple different installations that are usually difficult or even impossible to integrate. In our opinion the integration leads to increase in safety level of public transport and to improvement the quality of services offered. The novelty of the system is to provide collision, threats detection and fire alarm system integrated into a single coherent solution
Źródło:
Archives of Transport System Telematics; 2014, 7, 2; 45-50
1899-8208
Pojawia się w:
Archives of Transport System Telematics
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies