Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "field programmable analog array" wg kryterium: Temat


Wyświetlanie 1-7 z 7
Tytuł:
Analog Reconfirable Circuits
Autorzy:
Malcher, A.
Falkowski, P.
Powiązania:
https://bibliotekanauki.pl/articles/226956.pdf
Data publikacji:
2014
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
analog signal processing
configurable analog block
CAB
dynamic reconfiguration
field programmable analog array
FPAA
switched capacitor circuits
Opis:
The aim of this paper is to present an overview of a new branch of analog electronics represented by analog reconfigurable circuits. The reconfiguration of analog circuits has been known and used since the beginnings of electronics, but the universal reconfigurable circuits called Field Programmable Analog Arrays (FPAA) have been developed over the last two decades. This paper presents the classification of analog circuit reconfiguration, examples of FPAA solutions obtained as academic projects and commercially available ones, as well as some application examples of the dynamic reconfiguration of FPAA.
Źródło:
International Journal of Electronics and Telecommunications; 2014, 60, 1; 15-26
2300-1933
Pojawia się w:
International Journal of Electronics and Telecommunications
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Application of the FPAA to Sample Input Signal for Laboratory Exercise: Pulse Amplitude Modulation
Autorzy:
Grzechca, Damian
Chruszczyk, Lukas
Powiązania:
https://bibliotekanauki.pl/articles/227335.pdf
Data publikacji:
2020
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
field programmable analog array (FPAA)
signal processing
pulse amplitude modulation (PAM)
student laboratory
Opis:
This paper presents exemplary exercise on the fundamentals of signal processing course which is offered for second year bachelor level students. Application of Field Programmable Analog Array (FPAA) for pulse amplitude modulation (PAM) exercise is described with signal processing laboratory. There are presented two methods for implementing PAM modulation and demodulation technique in FPAA module. Example configuration files are available form Authors’ web site.
Źródło:
International Journal of Electronics and Telecommunications; 2020, 66, 1; 25-28
2300-1933
Pojawia się w:
International Journal of Electronics and Telecommunications
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Calibration of a mixed-signal power network transient stability analysis emulator
Autorzy:
Lanz, G
Fabre, L.
Lilis, G
Kyriakidis, T
Sallin, D
Cherkaoui, R.
Kayal, M.
Powiązania:
https://bibliotekanauki.pl/articles/398094.pdf
Data publikacji:
2013
Wydawca:
Politechnika Łódzka. Wydział Mikroelektroniki i Informatyki
Tematy:
analog computer
calibration
field programmable gate array (FPGA)
FPGA
mixed signal
power system dynamics
komputer analogowy
kalibracja
field-programmable gate array
sygnał mieszany
dynamika systemu elektroenergetycznego
Opis:
The emerging field of power system emulation for real time smart grid management is very demanding in terms of speed and accuracy. This paper provides detailed information about the electronics calibration process of a high-speed power network emulator dedicated to the transient stability analysis of power systems. This emulator uses mixed-signal hardware to model the dynamic behavior of a power network. Special design allows the self-calibration of the analog electronics through successive measurements and correction steps. The calibration operation guarantees high resolution of the transient stability analysis results, so that they can be reliably used for operational planning and control on real power networks.
Źródło:
International Journal of Microelectronics and Computer Science; 2013, 4, 4; 142-147
2080-8755
2353-9607
Pojawia się w:
International Journal of Microelectronics and Computer Science
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Hybrydowy detektor zespołu QRS wykorzystujący dynamicznie rekonfigurowalną matrycę analogową
Hybrid QRS detector based on dynamic reconfigurable field programmable analog array
Autorzy:
Machler, A.
Pietraszek, S.
Przybyła, T.
Powiązania:
https://bibliotekanauki.pl/articles/156631.pdf
Data publikacji:
2011
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
detektor zespołu QRS
programowalna matryca analogowa
urządzenie wspomagające pracę serca
rozrusznik serca
QRS detector
field programmable analog array
cardiac assist device
artificial stimulator
Opis:
W artykule zaprezentowano nową koncepcję układu detekcji w czasie rzeczywistym zespołu QRS z przebiegu elektrokardiograficzngo. W detektorze wykorzystano programowalną matrycę analogową AN221E04 firmy Anadigm. Parametry wybranych bloków są na bieżąco zmieniane w zależności od zmian parametrów przebiegu EKG dzięki dynamicznej rekonfigurowalności układu. Uzyskano bardzo krótki czas reakcji detektora na wykryty zespół QRS przy zadowalającej skuteczności detekcji. Opracowany detektor może znaleźć zastosowanie w aplikacjach biomedycznych wymagających wykrywania zespołu QRS w przebiegu EKG z małym opóźnieniem czasowym.
In many applications it is important to detect the QRS complex in the ECG waveform with possibly low time delay. Traditional software detectors of the QRS complex implement algorithms, usually based on cascades of digital filters, introduce delays up to parts of a second. Hardware QRS detectors (Fig. 1) fulfill the low delay requirements, but have worse adaptive features for the changing ECG shape. In this paper a new approach to QRS detection is presented. The proposed solution implements a classical detector structure in a Field Programmable Analog Array (FPAA) i.e. AN221E04 circuit from the AnadigmŽ company - Fig. 3. The most interesting feature of the FPAA is the dynamic reconfigurability. This solution makes it possible to modify the parameters of particular blocks of the detector or even the whole structure during runtime, without any changes in hardware and disturbance of the system functionality. Important parameters of particular blocks of the QRS detector are modified on-the-fly according to changes observed in the ECG signal. New data are calculated by the AD7020 microcontroller and downloaded to the FPAA using dynamic reconfigurability after each QRS detection. The prototype QRS detector was tested using a real ECG signal taken from Mit-Bih Arrythmia Database. The results obtained in the prototype circuit (Table 1) show that the detection delay is really small. The error rate of the QRS detection is low and can be acceptable in most real time applications.
Źródło:
Pomiary Automatyka Kontrola; 2011, R. 57, nr 1, 1; 22-24
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Modified current differencing transconductance amplifier - new versatile active element
Autorzy:
Malcher, A.
Powiązania:
https://bibliotekanauki.pl/articles/201665.pdf
Data publikacji:
2012
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
current differencing transconductance amplifier
quadrature oscillator
amplitude regulation
current-mode operational amplifier
continuous time field programmable analog array
Opis:
This paper introduces a new current mode component called Modified Current Differencing Transconductance Amplifier (MCDTA). Important parameters of the circuit i.e. input resistance, z terminal resistance and transconductance of the output stage can be tuned electrically. The circuit can be implemented in linear and non-linear analog signal processing. The paper presents an example of the MCDTA application - a complete quadrature oscillator with the amplitude regulation. The functionality of the example circuit and its tuning capability were proved by the SPICE simulation results.
Źródło:
Bulletin of the Polish Academy of Sciences. Technical Sciences; 2012, 60, 4; 739-750
0239-7528
Pojawia się w:
Bulletin of the Polish Academy of Sciences. Technical Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
QRS complexes detector for synchronization of ventricular assist device
Autorzy:
Mocha, J.
Sobotnicki, A.
Czerw, M.
Gibiński, P.
Powiązania:
https://bibliotekanauki.pl/articles/332941.pdf
Data publikacji:
2010
Wydawca:
Uniwersytet Śląski. Wydział Informatyki i Nauki o Materiałach. Instytut Informatyki. Zakład Systemów Komputerowych
Tematy:
czujnik zespołu QRS
analogowe macierze programowalne
sztuczne serce
urządzenie wspomagające czynność komór serca
detector of the QRS complexes
field programmable analog array (FPAA)
artificial heart (ventricular assist device - VAD)
Opis:
Synchronization of operation of an artificial chamber supporting the sick heart of a patient has a crucial meaning for the effectiveness of support. To make the synchronized operation possible, the information on patient's heart activity should be fed to a controller of the supporting chamber. To this end, the QRS complex detector operating on ECG signal is necessary. The signal must be acquired from a patient's heart. Appropriate signal quality at long-term support may be assured only in a case the signal is acquired with epicardial electrodes. In the paper, the concept of hardware construction of a QRS complex detector has been presented, based on a field programmable analog array FPAA. The results of verification of the developed detector include the correct operation while using the epicardial signals recorded from patients which undergone the cardiosurgical operations.
Źródło:
Journal of Medical Informatics & Technologies; 2010, 16; 35-41
1642-6037
Pojawia się w:
Journal of Medical Informatics & Technologies
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Real time QRS detector based on field programmable analog array
Autorzy:
Malcher, A.
Pietraszek, S.
Przybyła, T.
Kidoń, Z.
Powiązania:
https://bibliotekanauki.pl/articles/333130.pdf
Data publikacji:
2009
Wydawca:
Uniwersytet Śląski. Wydział Informatyki i Nauki o Materiałach. Instytut Informatyki. Zakład Systemów Komputerowych
Tematy:
detektor QRS
stymulator serca
sztuczny stymulator
QRS detector
field programmable analog array
baseline drift
cardiac assist device
artificial stimulator
pacemaker
Opis:
In some applications it is important to detect the QRS complex in the ECG waveform with possibly low time delay. Traditional software detectors of the QRS complex implement algorithms usually based on cascades of digital filters that introduce delays up to parts of a second. On the other hand, hardware QRS detectors fulfil the low delay requirements, but have worse adaptive features for the changing ECG shape. In this paper a new approach to QRS detection is presented. The proposed detector is based on a Field Programmable Analog Array (FPAA). This solution makes it possible to modify the parameters of particular blocks of the detector or even the whole structure without any changes in hardware, while the processing path is fully analog and does not introduce an additional delay. The most interesting feature of the FPAA is the dynamic reconfigurability. The parameters can be changed during runtime without any reset of the circuit or any other disturbances of the system functionality. The prototype QRS detector was built using the AN221E04 circuit from the Anadigm company.
Źródło:
Journal of Medical Informatics & Technologies; 2009, 13; 183-188
1642-6037
Pojawia się w:
Journal of Medical Informatics & Technologies
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-7 z 7

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies