Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "field measurements" wg kryterium: Temat


Wyświetlanie 1-30 z 30
Tytuł:
A method of the magnetic field formation in cyclotron DC-72
Autorzy:
Gulbekian, G.
Ivanenko, I.
Filatov, O.
Franko, J.
Kukhtin, V.
Lamzin, E.
Samsonov, E.
Semchenkov, A.
Semchenkova, O.
Sytchevsky, S. E.
Dmitrev, S. N.
Powiązania:
https://bibliotekanauki.pl/articles/148354.pdf
Data publikacji:
2003
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
cyclotron
magnetic field measurements
magnetic field simulations
Opis:
A method of the magnetic field formation in the cyclotron DC-72 model (scale 1:5) is described. The cyclotron is planned to be built in Slovakia. The stages in the shimming of the cyclotron sectors and an automatic system designed for magnetic measurements are described. The data on the magnetic field measurements in the median plane of the cyclotron are presented. A brief description of a computer simulation model and an algorithm of fitting the required sector profiles is presented, as well as the data on the computer simulation of magnetic field distributions. The data on the magnetic field measurements and those on the computer simulations are compared and analyzed. Possible reasons of differences between the measured and simulated data are discussed. The results of the above mentioned computer simulations will be used for building a large facility - the cyclotron DC-72.
Źródło:
Nukleonika; 2003, 48, 4; 207-210
0029-5922
1508-5791
Pojawia się w:
Nukleonika
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The Simultaneous Occurrence of Logarithmic and S-Shaped Velocity Profiles in Gravel-Bed River Flows
Autorzy:
Franca, M. J.
Lemmin, U.
Powiązania:
https://bibliotekanauki.pl/articles/241179.pdf
Data publikacji:
2009
Wydawca:
Polska Akademia Nauk. Instytut Budownictwa Wodnego PAN
Tematy:
field measurements
gravel-bed river flows
velocity profiles
Opis:
Based on Acoustic Doppler Velocity Profiler (ADVP) field measurements, we discuss velocity profiles observed in two shallow gravel-bed rivers with low relative submergence. In these flows, log-shaped profiles and s-shaped profiles simultaneously exist, indicating the possibility of 3D flow inside the roughness layer. A quasi-2D layer is generally found in an intermediate region of the flow above the roughness layer. Therefore a best-fit log-law approach may lead to estimates of a roughness parameter which are reasonably correlated with the local flow resistance. However, above a certain limit of the ratio roughness/water depth (∼0.6 from our measurements), the velocity distribution in the lower regions predominantly corresponds to an s-shaped profile.
Źródło:
Archives of Hydro-Engineering and Environmental Mechanics; 2009, 56, 1-2; 29-41
1231-3726
Pojawia się w:
Archives of Hydro-Engineering and Environmental Mechanics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Measurements of Concentration differences between Liquid Mixtures using Digital Holographic Interferometry
Autorzy:
Guerrero-Méndez, C.
Saucedo-Anaya, T.
Araiza-Esquivel, M.
Balderas-Navarro, R. E.
López-Martínez, A.
Olvera-Olvera, C.
Powiązania:
https://bibliotekanauki.pl/articles/221594.pdf
Data publikacji:
2017
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
Digital Holographic Interferometry
refractive index measurements
phase difference
full-field measurements
Opis:
We present an alternative method to detect and measure the concentration changes in liquid solutions. The method uses Digital Holographic Interferometry (DHI) and is based on measuring refractive index variations. The first hologram is recorded when a wavefront from light comes across an ordinary cylindrical glass container filled with a liquid solution. The second hologram is recorded after slight changing the liquid’s concentration. Differences in phase obtained from the correlation of the first hologram with the second one provide information about the refractive index variation, which is directly related to the changes in physical properties related to the concentration. The method can be used − with high sensitivity, accuracy, and speed − either to detect adulterations or to measure a slight change of concentration in the order of 0.001 moles which is equivalent to a difference of 0.003 g of sodium chloride in solutions. The method also enables to measure and calculate the phase difference among each pixel of two samples. This makes it possible to generate a global measurement of the phase difference of the entire sensed region.
Źródło:
Metrology and Measurement Systems; 2017, 24, 1; 19-26
0860-8229
Pojawia się w:
Metrology and Measurement Systems
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The Possibilities of Using Hec-Ras Software For Modelling Hydraulic Conditions of Water Flow in the Fish Pass Exampled by the Pomiłowo Barrage on The Wieprza River
Autorzy:
Hammerling, M.
Walczak, N.
Walczak, Z.
Zawadzki, P.
Powiązania:
https://bibliotekanauki.pl/articles/952477.pdf
Data publikacji:
2016
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
field measurements
fish pass
water table topology
HEC-RAS
Opis:
The aim of the article is to analyse hydraulic conditions of water flow in a fish pass. The test facility is part of the Pomiłowo barrage in the commune of Sławno, Poland. The authors applied HEC-RAS software for modelling hydraulic parameters of the water flow in the fish pass. The data from field measurements was implemented in the software and calculations of changes in the water table in the fish pass were made. The results confirmed the usefulness of HEC-RAS software for estimating hydraulic parameters of water flow in a fish pass. HEC-RAS software enables to take into account the parameters responsible for the phenomena accompanying the flow through a fish pass. Selecting mathematical model parameters (coefficients) should be preceded by a multidimensional analysis of the facility. More precise information on hydraulics, hydrology and biology of the test fish pass are also required.
Źródło:
Journal of Ecological Engineering; 2016, 17, 2; 81-89
2299-8993
Pojawia się w:
Journal of Ecological Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Minimizing of tunneling effect on existing infrastructure in Egypt
Autorzy:
Asker, Kamel I.
Fouad, Mohamed T.
Bahr, Mohamed A.
El-Attar, Ahmed N.
Powiązania:
https://bibliotekanauki.pl/articles/35525187.pdf
Data publikacji:
2021
Wydawca:
Szkoła Główna Gospodarstwa Wiejskiego w Warszawie. Wydawnictwo Szkoły Głównej Gospodarstwa Wiejskiego w Warszawie
Tematy:
tunneling
grouting
field measurements
Abaqus
Al-Azhar twin tunnel
Opis:
A set of parametric studies by using the Abaqus software is conducting to investigate the effective method to seal the CWO sewer from the tunneling process. These methods include: (i) two deep grouted walls, (ii) adjacent slurry piles, (iii) bored reinforced concrete piles assisted with slurry piles, and (iv) grouted block confining the twin tunnel wall. Based on the results of parametric studies. Most of the protective studied technique was effective on reducing the tunneling effect on the ground movements.
Źródło:
Scientific Review Engineering and Environmental Sciences; 2021, 30, 1; 3-15
1732-9353
Pojawia się w:
Scientific Review Engineering and Environmental Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wzorzec niestacjonarnego pola elektromagnetycznego
Non-Stationary EMF Standard
Autorzy:
Długosz, T.
Trzaska, H.
Powiązania:
https://bibliotekanauki.pl/articles/209322.pdf
Data publikacji:
2009
Wydawca:
Wojskowa Akademia Techniczna im. Jarosława Dąbrowskiego
Tematy:
pomiary pola elektromagnetycznego
niestacjonarne pole elektromagnetyczne
układy ekspozycyjne
electromagnetic field measurements
nonstationary electromagnetic fields
EMF standards
Opis:
W artykule przedstawiono pokrótce błędy w pomiarach PEM, ze szczególnym uwzględnieniem błędów podczas pomiarów pól impulsowych. Błędy te wynikają z wzorcowania mierników z wykorzystaniem fali ciągłej lub fali ciągłej modulowanej impulsowo. Cel pracy jest dwojaki: wprowadzenie do koncepcji nowej metody, która umożliwia wzorcowanie mierników PEM przeznaczonych do pomiarów niestacjonarnych PEM; ocena możliwości uproszczenia metody drogą stosowania pobudzenia wzorca paczkami impulsów o kształcie prostokątnym w miejsce sinusoidalnych.
Errors of EMF measurements were briefly presented in the work with special emphasis to the errors when pulsed fields are measured. The errors resulted from meter calibrations using CW or even continuous pulsed wave excitation. The aim of the presentation is twofold: introduction to an idea of a new method that allows a calibration of EMF meters devoted to nonstationary field measurements, evaluation of the possibility of simplification of the method using rectangular train of pulses instead of sinusoidal one.
Źródło:
Biuletyn Wojskowej Akademii Technicznej; 2009, 58, 4; 79-89
1234-5865
Pojawia się w:
Biuletyn Wojskowej Akademii Technicznej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Issues involved in using the direct method for magnetic field strength measurement of electrical steel sheets – review
Problemy pomiaru natężenia pola magnetycznego blach elektrotechnicznych metodą bezpośrednią – przegląd
Autorzy:
Gaworska-Koniarek, D.
Bajorek, J.
Wilczyński, W.
Powiązania:
https://bibliotekanauki.pl/articles/159080.pdf
Data publikacji:
2016
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Elektrotechniki
Tematy:
pomiar natężenia pola magnetycznego
czujniki pola magnetycznego
metoda bezpośrednia
magnetic field strength measurements
magnetic field sensor
magnetic field measurement
direct method
Opis:
W artykule, na podstawie dokonanego przeglądu literatury, przedstawiono istniejące problemy pomiaru natężenia pola magnetycznego metodą pośrednią i bezpośrednią w blachach elektrotech-nicznych oraz próby ich rozwiązania. Opisano czujniki składowej natężenia pola magnetycznego stosowane najczęściej do pomiaru natężenia pola magnetycznego w blachach elektrotechnicznych.
The paper presents, based on a review of relevant literature, the existing problems of magnetic field strength measurements of electrical steel sheets by means of the indirect and direct methods. It also describes some attempts to solve these problems. The magnetic field strength sensors most widely used for testing electrical steel sheets are also discussed.
Źródło:
Prace Instytutu Elektrotechniki; 2016, 274; 71-82
0032-6216
Pojawia się w:
Prace Instytutu Elektrotechniki
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Narażenie na pole elektromagnetyczne w przestrzeni pracy podczas użytkowania urządzeń do magnetoterapii lub magneto stymulacji : metoda pomiaru pola elektromagnetycznego in situ – wymagania szczegółowe
Exposure to the electromagnetic field in the work space during the use of magnetotherapy or magnetostimulation devices : the method of in situ measurements of electromagnetic field–specific requirements
Autorzy:
Karpowicz, J.
Aniołczyk, H.
Bieńkowski, P.
Gryz, K.
Kieliszek, J.
Politański, P.
Zmyślony, M.
Zradziński, P.
Powiązania:
https://bibliotekanauki.pl/articles/138347.pdf
Data publikacji:
2016
Wydawca:
Centralny Instytut Ochrony Pracy
Tematy:
magnetoterapia
magnetostymulacja
pole magnetyczne
pomiary pola elektromagnetycznego
metoda rekomendowana
środowisko pracy
bezpieczeństwo i higiena pracy
zdrowie publiczne
magnetotherapy
magnethostimulation
magnetic field
electromagnetic field measurements
recommended method
work environment
occupational safety and health
public health
Opis:
W prawie pracy określono obowiązek rozpoznania i oceny zagrożeń elektromagnetycznych w otoczeniu urządzeń i instalacji emitujących pole elektromagnetyczne (pole-EM). W rozporządzeniu Ministra Rodziny, Pracy i Polityki Społecznej z dnia 29 czerwca 2016 r. w sprawie bezpieczeństwa i higieny pracy przy pracach związanych z narażeniem na pole-EM wśród typowych źródeł pola-EM wymieniono „urządzenia do magnetoterapii” (DzU 2016, poz. 950, zał. 1., poz. 10., zm. poz. 2284). Urządzania do magnetoterapii są wykorzystywane do łagodzenia różnych dolegliwości, z wykorzystaniem oddziaływania quasi-statycznego pola-EM. Podczas zabiegu w pobliżu aktywnych aplikatorów występuje pole-EM stref ochronnych. W związku z tym, warunki narażenia pracujących podczas użytkowania aplikatorów wymagają okresowej kontroli, wykonanej „zgodnie z metodami określonymi w Polskich Normach, a w przypadku braku takich norm, metodami rekomendowanymi i zwalidowanymi” zgodnie z wymaganiami zawartymi w rozporządzeniu Ministra Zdrowia z dnia 2 lutego 2011 r. w sprawie badań i pomiarów czynników szkodliwych dla zdrowia w środowisku pracy (DzU 2011, poz. 166), celem rozpoznania zagrożeń elektromagnetycznych i podjęcia odpowiednich środków ochronnych (DzU 2016, poz. 950, zm. poz. 2284). Metody pomiarów pola-EM w zakresie koniecznym do realizacji wspomnianych wymagań nie są obecnie znormalizowane, w związku z tym, celem relacjonowanej pracy było opracowanie metody rekomendowanej do pomiaru parametrów pola-EM in situ w przestrzeni pracy, podczas użytkowania urządzeń do magnetoterapii lub magnetostymulacji. Na podstawie wyników przeprowadzonych badań wykazano, że podczas zabiegu fizyko-terapeutycznego źródłem pola-EM jest jedynie aplikator do magnetoterapii lub magnetostymulacji. W przypadku wykorzystywania pola-EM o częstotliwości podstawowej do 100 Hz o sinusoidalnym lub niesinusoidalnym przebiegu ciągłym – przemiennym lub prostowanym (tj. ze składową stałą), zasięg pola-EM stref ochronnych jest determinowany przez rozkład przestrzenny quasi-statycznego pola magnetycznego (pola-M). Ponieważ tego typu urządzenia przeważają w polskich placówkach fizykoterapeutycznych, do oceny zagrożeń elektromagnetycznych w przestrzeni pracy rekomendowano użycie uproszczonej metody pomiarów. Polega ona na pomiarze wartości skutecznej (RMS) na-tężenia pola-M w sinusoidalnym trybie pracy urządzenia. W ocenie wyników w takim przypadku uwzględnia się limity narażenia określone w prawie pracy w stosunku do wartości równoważnych natężenia pola-M przez użycie odpowiedniego współczynnika korekcyjnego, odzwierciedlającego konieczność zaostrzonej oceny narażenia przy niesinusoidalnym trybie pracy urządzenia (tj. użycie limitów określonych dla pola-EM o częstotliwości 100 Hz). W przypadku urządzeń emitujących pole-EM o częstotliwościach z zakresu kiloherców (kHz) lub pola-EM o impulsowej charakterystyce zarekomendowano stosowanie bardziej złożonych pomiarów, obejmujących indywidualne rozpoznanie charakterystyk mierzonego pola-EM i określenie współczynników korekcyjnych do interpretacji wyników pomiarów wartości skutecznej na podstawie charakterystyk metrologicznych stosowanych przyrządów pomiarowych. W metodzie określono również zasady: przygotowania pomiarów i aparatury pomiarowej, wyboru punktów pomiarowych, wyznaczania zasięgu stref ochronnych oraz dokumentowania wyników pomiarów. Omówiono również najistotniejsze źródła niepewności wyników pomiaru pola-EM w przestrzeni pracy przy omawianych urządzeniach.
Labour law defines the obligation to identify and evaluate electromagnetic hazards in the vicinity of equipment and installations emitting an electromagnetic field (EM-field). Following the regulation of ministry of labour which set the provisions regarding the safety and health in EM-field, the "devices for magnetotherapy" have been mentioned among the typical sources of an EM-field (OJ 2016 items 950 and 2284, Annex 1, item 10). Magnetotherapy devices are used to alleviate various diseases, using the influence of aquasistatic EM-field. The protective zones of the EM-field are present near the active applicators during the treatment, so the conditions of exposure of personnel present nearby during the use of the applicators require a periodic inspection made "according to the methods specified in the Polish Standards, and in the absence of such standards, by recommended and validated methods according to the provisions of regulation of ministry of health (Regulation...,Journal of Laws2011, item 166), in order to identify electromagnetic hazards and to take appropriate protective measures (OJ 2016 item 950and 2284).The methods of measuring the EM-field to the extent necessary to meet the serequirements are currently not standardised; therefore, the aim of the presented work was to develop a recommended method for measuring the parameters of the EM-field in-situin the work space while using magnetotherapy or magneto stimulation devices.The recommended measurement method is based on detailed investigations on the characteristics of exposure to the EM-field surrounding typical magnetotherapy devices operated in Poland: by approx. 700 applicators of 500 devices (such as Magnetronic (series MF-10, MF-12, MF 20 and BTL), Magnetus (series 2 and 2.26), Magnoter (series D-56, D56A BL), Magner LT, Magner Plus, Magneris, MAG magnetic, Magnetic, Astar ABR).The oscilloscopic identification, the characteristics of variability in the time of the EM-field emitted by devices for magnetotherapy and magneto stimulation, and the measurements of the spatial distribution of the EM-field in the workspace by devices have been worked out. Based on the results of the study, it was shown that, during physiotherapy treatment, only the applicator for magnetotherapy or magneto stimulation is the source of the EM-field. When using an EM-field with a frequency of up to 100 Hz and a continuous sinusoidal or non-sinusoidal waveform –alternating or rectified (i.e. with a constant component) –the range of protective zones of EM-field is deter-mined by the spatial distribution of the quasi-static magnetic field (M-field). Because this type of device predominates in Polish physiotherapy centres, to assess electromagnetic hazards in the workspace, it was recommended to use a simplified method of measurement, involving the measurement of the root-mean-square (RMS) value of the M-field strength in sinusoidal operation mode and an evaluation of results, taking into account the limits reflect-ing the measures of exposure specified in the labour law in relation to the equivalent value of the M-field strength, but using an appropriate correction factor reflecting the need to strengthen the exposure evaluation at non-sinusoidal modes of operation (i.e. by the use of limits set for EM-field of 100 Hz frequency). In the case of devices emitting an EM-field with frequencies in the kilohertz (kHz) range or a pulsed EM-field, it was recommended to use more complex measurements, including an individual analysis of the characteristics of the measured EM-field and a determination of correction factors to the interpretation of the measured RMS value (based on the metrological characteristics of measuring devices used). The method also sets out principles for: measurements and measurement devices preparation, locating the measurement points, determining the range of protection zones and documenting the measurement results. The most important sources of uncertainty concerning EM-field measurements in the workspace near magnetotherapy or magnetic stimulation applicators were also discussed.
Źródło:
Podstawy i Metody Oceny Środowiska Pracy; 2016, 4 (90); 151-180
1231-868X
Pojawia się w:
Podstawy i Metody Oceny Środowiska Pracy
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Podstawy oceny i ograniczania elektromagnetycznego oddziaływania infrastruktury elektroenergetycznej doładowania pojazdów samochodowych o napędzie elektrycznym. Program stosowania środków ochronnych. Metoda rekomendowana pomiaru pola elektromagnetycznego in situ – wymagania szczegółowe
Principles of assessing and mitigating the electromagnetic impact of the power infrastructure for charging electric vehicles. The programme of applying protection measures. The recommended method of making in situ measurements of the electromagnetic fi eld – specifi c requirements
Autorzy:
Gryz, Krzysztof
Śmietanka, Hubert
Karpowicz, Jolanta
Zradziński, Patryk
Powiązania:
https://bibliotekanauki.pl/articles/23352074.pdf
Data publikacji:
2022
Wydawca:
Centralny Instytut Ochrony Pracy
Tematy:
instalacje elektroenergetyczne
inżynieria środowiska
pojazdy elektryczne
pomiary pola elektromagnetycznego
metoda rekomendowana pomiaru pola elektromagnetycznego
środowisko pracy
bezpieczeństwo i higiena pracy
nauki o zdrowiu
electric power installations
environmental engineering
electric vehicles
electromagnetic field measurements
recommended method of measurements of electromagnetic field
work environment
occupational health and safety
health sciences
Opis:
Rozwój elektromobilności, czyli wykorzystania pojazdów samochodowych o napędzie elektrycznym, a także infrastruktury technicznej zapewniającej energię do poruszania się takich pojazdów po drogach (stacji ładowania), wiąże się z emisją pola elektromagnetycznego (pola-EM). Zgodnie z wymaganiami prawa pracy, pole-EM jest oceniane i ograniczane w środowisku pracy ze względu na zagrożenia bezpieczeństwa i zdrowia, jakie mogą być związane ze skutkami ich bezpośredniego i pośredniego oddziaływania na człowieka i obiekty materialne podczas zróżnicowanych warunków użytkowania jego źródeł (obejmującego m.in. rutynową eksploatację, kontrolę i serwisowanie), (rozporządzenie ministra ds. pracy: DzU 2018, poz. 331 (t.j.)). Omówiono rodzaje typowych stacji ładowania pojazdów samochodowych o napędzie elektrycznym oraz charakterystykę pola-EM występującego w otoczeniu stacji podczas ich użytkowania. Z uwagi na rozpoznaną możliwość występowania w otoczeniu stacji ładownia pojazdów o napędzie elektrycznym pola-EM wymagającego oceny ze względu na wymagania prawa pracy, opracowano rekomendowaną metodę pomiaru parametrów pola-EM in situ w przestrzeni pracy podczas użytkowania tego rodzaju urządzeń, spełniającą wymagania prawa pracy (rozporządzenia ministra ds. pracy: DzU 2018, poz. 331 (t.j.) i poz. 1286). Zaprezentowano również kluczowe elementy programu stosowania środków ochronnych dotyczących ograniczania zagrożeń elektromagnetycznych podczas użytkowania infrastruktury elektroenergetycznej ładowania pojazdów samochodowych o napędzie elektrycznym, wymaganych do zapewnienia pracownikom bezpiecznych i higienicznych warunków pracy w otoczeniu takich źródeł pola-EM.
The development of e-mobility, electric vehicles and the technical infrastructure that provides energy to move vehicles on the roads (charging stations) has led to increased electromagnetic field (EMF) emissions. In accordance with the requirements set out by provisions of labour law, EMF emissions are assessed and must be limited in the work environment due to the health and safety hazards that are associated with the direct and indirect impact of EMF on humans and material objects during various conditions of using EMF sources (including routine operation, inspection and servicing) (Regulation of ministry of labour issues: J.L. 2018, item 331). The paper discusses typical charging stations for electric vehicles and the characteristic of the EMF present nearby during their use. Due to the recognised possibility of relatively significant EMF level near to charging stations, the recommended method of EMF parameters in situ measurements in the workplace while using this type of equipment was developed, meeting the labour law requirements (Regulations of ministry of labour issues: J.L. 2018, item 331 and 1286). The paper also presents the key elements of the programme of applying protective measures to reduce electromagnetic hazards while using electric power infrastructure for charging electric vehicles, which are required in order to provide workers with safe and hygienic working conditions in the vicinity of EMF sources.
Źródło:
Podstawy i Metody Oceny Środowiska Pracy; 2022, 4 (114); 111--135
1231-868X
Pojawia się w:
Podstawy i Metody Oceny Środowiska Pracy
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Detection of ferromagnetic objects by using scalar magnetometers
Autorzy:
Jakubiuk, K.
Wołoszyn, M.
Powiązania:
https://bibliotekanauki.pl/articles/97481.pdf
Data publikacji:
2013
Wydawca:
Politechnika Poznańska. Wydawnictwo Politechniki Poznańskiej
Tematy:
magnetic field
magnetization of ferromagnetic object
measurements of magnetic field
scalar magnetometers
detection of ferromagnetic object
Opis:
The paper presents the results of the analysis of the possibility of detecting ferromagnetic objects (ships, submarines, mines, etc.) by using two scalar magnetometers. By using two magnetometers of high sensitivity (in the order of magnitude of pT/Hz0,5) placed at a distance from each other and operating in a differential system, it is possible to detect ferromagnetic objects from a distance. It is necessary to compensate for the error code to synchronize the work of the two magnetometers. Ferromagnetic object’s detection by using two magnetometers requires proper configuration of the devices.
Źródło:
Computer Applications in Electrical Engineering; 2013, 11; 83-91
1508-4248
Pojawia się w:
Computer Applications in Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Narażenie na pole elektromagnetyczne w przestrzeni pracy podczas użytkowania systemów elektroenergetycznych i elektrycznych instalacji zasilających prądu przemiennego w energetyce : metoda pomiaru pola elektromagnetycznego in situ – wymagania szczegółowe
Exposure to the electromagnetic field in the work space during the use of electricity and electric installations of alternating current in power engineering : the method of in situmeasurements of electromagnetic field –specific requirements
Autorzy:
Szuba, M.
Hasiec, I.
Papliński, P.
Śmietanka, H.
Zajdler, K
Zmyślony, M.
Gryz, K.
Karpowicz, J.
Powiązania:
https://bibliotekanauki.pl/articles/138452.pdf
Data publikacji:
2016
Wydawca:
Centralny Instytut Ochrony Pracy
Tematy:
elektroenergetyczne linie wysokiego napięcia
rozdzielnie elektroenergetyczne
instalacje elektroenergetyczne
pole elektryczne
pole magnetyczne
pomiary pola elektromagnetycznego
metoda rekomendowana
środowisko pracy
bezpieczeństwo i higiena pracy
high voltage power lines
high voltage switchyards
electric power installations
electric field
magnetic field
electromagnetic field measurements
recommended method
working environment
occupational safety and health
Opis:
Pole elektromagnetyczne (pole-EM) występuje w otoczeniu wszystkich instalacji i urządzeń zasilanych energią elektryczną, jest więc również nierozerwalnie związane z przesyłaniem energii elektrycznej przez sieć elektroenergetyczną, tworzoną głównie przez linie i rozdzielnie elektroenergetyczne: najwyższych, wysokich, średnich i niskich napięć, w których otoczeniu może występować pole-EM stref ochronnych. Obiekty takie zostały wymienione wśród typowych źródeł pola-EM jako „systemy elektroenergetyczne i elektryczna instalacja zasilająca” w rozporządzeniu Ministra Rodziny, Pracy i Polityki Społecznej z dnia 29 czerwca 2016 r. w sprawie bezpieczeństwa i higieny pracy przy pracach związanych z narażeniem na pole-EM (DzU 2016, poz. 950, zm. poz. 2284; zał. 1., poz. 2.). W związku z tym, warunki narażenia pracujących w otoczeniu urządzeń lub instalacji sieci elektroenergetycznych wymagają okresowej kontroli, zgodnie z wymaganiami określonymi w rozporządzeniu Ministra Zdrowia z dnia 2 lutego 2011 r. w sprawie badań i pomiarów czynników szkodliwych dla zdrowia w środowisku pracy, w którym określono, że powinna być ona wykonana „zgodnie z metodami określonymi w Polskich Normach, a w przypadku braku takich norm, metodami rekomendowanymi i zwalidowanymi” (DzU 2011, poz. 166). Celem takiej kontroli jest rozpoznanie zagrożeń elektromagnetycznych w przestrzeni pracy i podjęcie odpowiednich środków ochronnych (DzU 2016, poz. 950, zm. 2284). Ponieważ metody pomiarów pola-EM odpowiednie do realizacji tych wymagań prawa pracy nie są obecnie znormalizowane, celem przeprowadzonych badań było opracowanie metody rekomendowanej do pomiaru parametrów pola-EM in situ w przestrzeni pracy, podczas użytkowania sieci elektroenergetycznych. Rekomendowana metoda pomiarów została opracowana na podstawie przeglądu: parametrów konstrukcyjnych i elektrycznych infrastruktury energetycznej użytkowanej w Polsce, przeglądu danych literaturowych oraz wyników badań własnych wykonanych przez autorów w kilkuset obiektach elektroenergetycznych (najwyższych, wysokich, średnich i niskich napięć) o zróżnicowanej strukturze geometrycznej i funkcjonalnej, użytkowanych na terenie całego kraju. Przeprowadzone pomiary obejmowały pomiary wartości skutecznych natężenia pola elektrycznego i natężenia pola magnetycznego w przestrzeni pracy, z wyłączeniem narażeń występujących podczas prac wykonywanych wg procedur określanych jako praca na potencjale. Przeprowadzone badania obejmowały pomiary wartości skutecznej natężenia pola elektrycznego i natężenia pola magnetycznego w przestrzeni pracy, z wyłączeniem narażeń występujących podczas prac wykonywanych według procedur określanych jako praca na potencjale. Pomiary obejmowały następujące obiekty prądu przemiennego użytkowane w ramach krajowego systemu elektroenergetycznego: napowietrzne i wnętrzowe rozdzielnie elektroenergetyczne o napięciach znamionowych (110 ÷ 750) kV oraz linie elektroenergetyczne o napięciach znamionowych (110 ÷ 400) kV, określanych jako wysokie lub najwyższe napięcia (WN lub NN); linie elektroenergetyczne niskiego lub średniego napięcia (nn lub SN) o napięciach znamionowych (0,4 ÷ 110) kV (z wyłączeniem obiektów o napięciu 110 kV, zaliczanym do WN); rozdzielnie i transformatory nn lub SN o napięciach znamionowych (0,4 ÷ 110) kV (z wyłączeniem obiektów o napięciu 110 kV, zaliczanym do WN); generatory prądu wraz z torami prądowymi oraz aparaturą łączeniową i pomiarową o mocach powyżej 1 MW; instalacje potrzeb własnych na stacjach elektroenergetycznych; trójfazowe instalacje przemysłowe. Na podstawie wyników przeprowadzonych badań wykazano, że podczas użytkowania wspomnianych elementów sieci elektroenergetycznej są wykorzystywane prądy przemienne o częstotliwości 50 Hz i o stabilnym napięciu charakterystycznym dla jej poszczególnych obiektów, a obciążeniach prądowych zmieniających się w znacznym stopniu (o kilkaset procent), zależnie od zapotrzebowania odbiorców na energię elektryczną. W związku z tym, zarekomendowano metodę pomiarów, która obejmuje pomiar wartości skutecznej (RMS) natężenia pola elektrycznego i natężenia pola magnetycznego, których wyniki są oceniane bezpośrednio w odniesieniu do limitów narażenia, które określono w prawie pracy w stosunku do wartości równoważnych takich parametrów narażenia. W metodzie określono również zasady: przygotowania pomiarów i aparatury pomiarowej, wyboru punktów pomiarowych, wyznaczania zasięgu stref ochronnych oraz dokumentowania wyników pomiarów, a także warunki klimatyczne wykonywania pomiarów. Omówiono również najistotniejsze źródła niepewności wyników pomiaru pola-EM przy omawianych urządzeniach elektroenergetycznych.
Electromagnetic field (EMF) occurs around all the installations and equipment powered by electricity, so it is also inextricably linked to the transmission of electricity through the power grid, created mainly by the power lines and switchyards of the highest, high, medium and low voltage. In their vicinity EMF of protection zones may occur. Such installations have been listed among the common sources of EMF as a "power systems and electrical power supply installation" in the Regulation of the Minister of Family, Labour and Social Policy on health and safety at work related to exposure to EMF(OJ 2016 item. 950, est. 1, pos. 2). The refore, the exposure conditions of workers in the vicinity of equipment or installation of power grids require periodic inspections in accordance with the requirements of the Regulation of the Minister of Health on the tests and measurements of health hazard factors in the working environment (Regulation ...., OJ 2011, pos. 166), which should be done "in accordance with the methods set out in Polish standards, in the absence of such standards, using recommended and validated methods". The purpose of such inspection is to identify the electromagnetic hazards in work space and take appropriate protective measures (OJ 2016 pos. 950). Because the methods of EMF measurement adequate to meet the requirements of labour law are currently not standardized, the objective of conducted research was to develop a method recommended for measuring parameters of the EMF in situ in the work space during the use of electricity networks. The recommended method of measurement was developed on the basis of the review of design and electrical parameters of energy infrastructure in Poland, the review of literature and own research performed by the authors in hundreds of power facilities (the highest, high, medium and low voltage)and installations of various geometrical and functional structures used in the whole country. The performed research included measurements of RMS value of electric field and magnetic field strength in the work space, with the exception of exposures occurring during the work performed according to procedures known as live-line work. The measurements included the following objects used in the national electricity grid: electrical switchyards with nominal voltage from 110 kV to 750 kV (outdoor and indoor); power lines of high voltage (HV) with nominal voltage from 110 kV to 400 kV; power lines of low or medium voltage (LV or MV) with rated voltage of 0.4 kV to 110 kV (with the exception of 110 kV); switchyards, LV or MV switchboards and transformers; generators with bus bars, cables etc., current transformers, switchgear and measuring equipment with capacity exceeding 1 MW, installations of own needs on electrical substations, three-phase alternating current industrial installations. On the basis of the results of the research it was demonstrated that during the use of these elements of the power grid alternating currents with a frequency of 50 Hz are used, with a stable voltage characteristic of the individual objects and the load current changing significantly (by several hundred percent), depending on customers’ demand for electricity. The measurement method was recommended which involves measuring the RMS value of electric field strength and magnetic field strength, which results are evaluated immediately with respect to the exposure limits set in the labour law to the equivalent value of such exposure parameters. The method also describes principles: measurements and measurement devices preparation, choice of measurement points, determining the ranges protection zones and document measurement results, as well a climatic conditions of measurements. It also discusses the most important sources of uncertainty of results of EMF measurement near discussed power devices.
Źródło:
Podstawy i Metody Oceny Środowiska Pracy; 2016, 4 (90); 91-150
1231-868X
Pojawia się w:
Podstawy i Metody Oceny Środowiska Pracy
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Estimation of Acoustic Impedance for Surfaces Delimiting the Volume of an Enclosed Space
Autorzy:
Piechowicz, J.
Czajka, I.
Powiązania:
https://bibliotekanauki.pl/articles/177215.pdf
Data publikacji:
2012
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
acoustic impedance
acoustic measurements
numerical methods
sound field
Opis:
Several methods can be applied for analyses of the acoustic field in enclosed rooms namely: wave propagation, geometrical or statistical analysis. The paper presents problems related to application of the boundary elements method to modelling of acoustic field parameters. Experimental and numerical studies have been combined for evaluation of acoustic impedance of the material used for the walls of a model room. The experimental studies have been carried out by implementing a multichannel measuring system inside the constructed model of an industrial room. The measuring system allowed simultaneous measurements of the source parameters – the loudspeaker membrane vibration speed, the acoustic pressure values in reception points located inside the model space as well as phase shifts between signals registered in various reception points. The numerical modelling making use of the acoustic pressure values measured inside the analyzed space allowed determination of requested parameters of the surface at the space boundary.
Źródło:
Archives of Acoustics; 2012, 37, 1; 97-102
0137-5075
Pojawia się w:
Archives of Acoustics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Occupational exposure to electromagnetic fields in the Polish Armed Forces
Autorzy:
Sobiech, Jaromir
Kieliszek, Jarosław
Puta, Robert
Bartczak, Dagmara
Stankiewicz, Wanda
Powiązania:
https://bibliotekanauki.pl/articles/2161913.pdf
Data publikacji:
2017-06-19
Wydawca:
Instytut Medycyny Pracy im. prof. dra Jerzego Nofera w Łodzi
Tematy:
electromagnetic field
occupational exposure
soldiers
measurements
radar
radio
Opis:
Objectives Standard devices used by military personnel that may pose electromagnetic hazard include: radars, missile systems, radio navigation systems and radio transceivers. The aim of this study has been to evaluate the exposure of military personnel to electromagnetic fields. Material and Methods Occupational exposure to electromagnetic fields was analyzed in the work environment of personnel of 204 devices divided into 5 groups (surface-to-air missile system radars, aircraft and helicopters, communication devices, surveillance and height finder radars, airport radars and radio navigation systems). Measurements were carried out at indicators, device terminals, radio panels, above vehicle seats, in vehicle hatches, by cabinets containing high power vacuum tubes and other transmitter components, by transmission lines, connectors, etc. Results Portable radios emit the electric field strength between 20–80 V/m close to a human head. The manpack radio operator’s exposure is 60–120 V/m. Inside vehicles with high frequency/very high frequency (HF/VHF) band radios, the electric field strength is between 7–30 V/m and inside the radar cabin it ranges between 9–20 V/m. Most of the personnel on ships are not exposed to the electromagnetic field from their own radar systems but rather by accidental exposure from the radar systems of other ships. Operators of surface-to-air missile systems are exposed to the electric field strength between 7–15 V/m and the personnel of non-directional radio beacons – 100–150 V/m. Conclusions In 57% of military devices Polish soldiers work in the occupational protection zones. In 35% of cases, soldiers work in intermediate and hazardous zones and in 22% – only in the intermediate zone. In 43% of devices, military personnel are not exposed to electromagnetic field. Int J Occup Med Environ Health 2017;30(4):565–577
Źródło:
International Journal of Occupational Medicine and Environmental Health; 2017, 30, 4; 565-577
1232-1087
1896-494X
Pojawia się w:
International Journal of Occupational Medicine and Environmental Health
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Modeling and Designing Acoustical Conditions of the Interior – Case Study
Autorzy:
Kostek, B.
Laskowski, S.
Mizgier, K.
Powiązania:
https://bibliotekanauki.pl/articles/176652.pdf
Data publikacji:
2016
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
acoustic field analysis
acoustic field modeling
acoustic conditions measurements
acoustic conditions analysis
sound reinforcement system design
Opis:
The primary aim of this research study was to model acoustic conditions of the Courtyard of the Gdańsk University of Technology Main Building, and then to design a sound reinforcement system for this interior. First, results of measurements of the parameters of the acoustic field are presented. Then, the comparison between measured and predicted values using the ODEON program is shown. Collected data indicate a long reverberation time which results in poor speech intelligibility. Then, a thorough analysis is perform to improve the acoustic properties of the model of the interior investigated. On the basis of the improved acoustic model two options of a sound reinforcement system for this interior are proposed, and then analyzed. After applying sound absorbing material it was noted that the predicted speech intelligibility increased from bad/poor rating to good category.
Źródło:
Archives of Acoustics; 2016, 41, 3; 473-484
0137-5075
Pojawia się w:
Archives of Acoustics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Investigations on the field of gravity in Polish tidal laboratories
Autorzy:
Barlik, M.
Bogusz, J.
Kaczorowski, M.
Powiązania:
https://bibliotekanauki.pl/articles/224712.pdf
Data publikacji:
2009
Wydawca:
Politechnika Warszawska. Wydział Geodezji i Kartografii
Tematy:
pole grawitacyjne
pomiary grawimetryczne
stacje badawcze
field of gravity
gravimetric measurements
reference stations
Opis:
Presently there are two laboratories in Poland investigating field of gravity. The Geodynamic Laboratory of Space Research Centre in Ksiaz is placed in the south-western part of Poland in horizontal galleries built in slope of the valley. In 1974 in the laboratory the measurements carried out with help of two quartz-horizontal pendulums equipped with photographic system of registration were begun. In 2002 in the laboratory the long water-tube tiltmeter was built. It is consisted of two perpendicular tubes 65- and 83-meter long, partially filled with water. In 2007 in the laboratory the relative gravimeter LaCoste&Romberg G-648 was installed. The Gravimetric Laboratory of Astro-Geodetic Observatory in Józefosław is placed in central part of Poland. It has been investigated tidal gravity changes since 1993 using first LC&R model G gravimeter, then D-model. Since 2001 laboratory is equipped with LC&R ET-26 meter. In 2005 the laboratory was equipped with FG5-230 gravimeter for monitoring of the absolute gravity variations. The paper presents current state-of-art of the researches aimed at investigation on field of gravity carried out by Polish scientific institutions.
Źródło:
Reports on Geodesy; 2009, z. 1/86; 43-52
0867-3179
Pojawia się w:
Reports on Geodesy
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Research on gravity field modelling and gravimetry in Poland in 2015–2018
Autorzy:
Krynski, Jan
Dykowski, Przemysław
Olszak, Tomasz
Powiązania:
https://bibliotekanauki.pl/articles/145412.pdf
Data publikacji:
2019
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
pole grawitacyjne
grawimetria
geoida
gravity field
gravimetry
global geopotential model
geoid
absolute gravity measurements
Opis:
Activities of the Polish research gSDroups concerning gravity field modelling and gravimetry in a period of 2015–2018 are reviewed and summarised in this paper. The summary contains the results of research on the evaluation of GOCE-based global geopotential models (GGMs) in Poland and geoid modelling. Extensive research activities are observed in the field of absolute gravity surveys, in particular for the maintenance of national gravity control in Poland, Sweden, Denmark, the Republic of Ireland and in Northern Ireland as well as for geodynamics with special emphasis on metrological aspects in absolute gravimetry. Long term gravity variations were monitored in two gravimetric laboratories: the Borowa Gora Geodetic-Geophysical Observatory, and Jozefoslaw Astrogeodetic Observatory with the use of quasi-regular absolute gravity measurements as well as tidal gravimeter records. Gravity series obtained were analysed considering both local and global hydrology effects. Temporal variations of the gravity field were investigated using data from GRACE satellite mission as well as SLR data. Estimated variations of physical heights indicato the need for kinematic realization of reference surface for heights. Also seasonal variability of the atmospheric and water budgets in Poland was a subject of investigation in terms of total water storage using the GLDAS data. The use of repeatable absolute gravity data for calibration/validation of temporal mass variations derived from satellite gravity missions was discussed. Contribution of gravimetric records to seismic studies was investigated. The bibliography of the related works is given in references.
Źródło:
Geodesy and Cartography; 2019, 68, 1; 31-63
2080-6736
2300-2581
Pojawia się w:
Geodesy and Cartography
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
GGOS information models: analysis of interrelations between observation techniques and the Earth gravity field
Autorzy:
Pachelski, W.
Paśnicka-Pawłowska, M.
Szafranek, K.
Zwirowicz, A.
Powiązania:
https://bibliotekanauki.pl/articles/225172.pdf
Data publikacji:
2008
Wydawca:
Politechnika Warszawska. Wydział Geodezji i Kartografii
Tematy:
GGOS
pomiary
rotacja Ziemii
pole grawitacyjne
geometria
kinematyka
measurements
rotation of Earth
gravitational field
geometry
kinematics
Źródło:
Reports on Geodesy; 2008, z. 2/85; 61-70
0867-3179
Pojawia się w:
Reports on Geodesy
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wpływ odległości od stacji referencyjnej ASG-EUPOS na dokładność kartowania terenowego odbiornikiem GPS klasy GIS
The influence of distance from the reference ASG-EUPOS station on the accuracy of GIS-class GPS field mapping
Autorzy:
Beluch, Ł.
Powiązania:
https://bibliotekanauki.pl/articles/346538.pdf
Data publikacji:
2014
Wydawca:
Polskie Towarzystwo Informacji Przestrzennej
Tematy:
dokładność kartowania terenowego
post-processing GPS
pomiary GIS
RTKlib
ASG-EUPOS
field mapping accuracy
GIS measurements
Opis:
W ostatnich latach coraz częściej do kartowania używa się odbiorników GPS. Oprócz odbiorników geodezyjnych, o dużej dokładności, wyodrębnić można odbiorniki klasy GIS charakteryzujące się pracą tylko na częstotliwości L1 w trybie kodowym, umożliwiające jednak wykonanie post-processingu danych w celu zwiększenia dokładności pomiaru. Dokładność pomiaru z post-processingiem maleje wraz ze wzrostem odległości od stacji referencyjnej. Autor na podstawie obserwacji z 50 stacji systemu ASG-EUPOS zbadał tę zależność wykorzystując obserwacje kodowe na częstotliwości L1. Stację LODZ potraktowano jako odbiornik ruchomy, natomiast pozostałe stacje jako referencyjne. Wykonano post-processing w oparciu o każdą stację osobno. Do obliczeń użyto bezpłatnego oprogramowania RTKlib. Wyniki potwierdzają spadek dokładności wraz ze wzrostem odległości, jednak nie jest to zależność liniowa. Generalnie badania dowodzą, że uśredniony błąd w najdalszym miejscu od stacji LODZ, oddalonym o ok. 350 km nie przekroczył 100 cm w poziomie i 170 cm w pionie.
There has been a significant increase in using GPS receivers in mapping during the last few years. Aside from high precision GPS receivers there are also GIS class receivers that work on L1 frequency in the code mode and enable performing post-processing of data. The post-processing accuracy decreases as the distance to the reference station increases. Based on observations from 50 ASG-EUPOS stations the author analyzed this phenomenon using code mode observations on L1 frequency. The LODZ station was considered to be a rover while the rest of stations were treated as reference stations. The post-processing was performed separately for every single station using freeware software RTKlib. The results confirmed the initial assumption: the accuracy decreases as the distances increase without being a linear relationship, though. In general, the survey proves that average error in the furthest spot (350km from LODZ station) is no greater than 100 cm horizontally and 170 cm vertically.
Źródło:
Roczniki Geomatyki; 2014, 12, 1(63); 7-17
1731-5522
2449-8963
Pojawia się w:
Roczniki Geomatyki
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Research on gravity field modelling and gravimetry in Poland in 2019–2022
Autorzy:
Krynski, Jan
Dykowski, Przemysław
Godah, Walyeldeen
Szelachowska, Małgorzata
Powiązania:
https://bibliotekanauki.pl/articles/43852764.pdf
Data publikacji:
2023
Wydawca:
Polska Akademia Nauk. Czasopisma i Monografie PAN
Tematy:
geoida
pole grawitacyjne
grawimetria
geoid
gravity field
absolute gravity measurements
gravimetry
GRACE/GRACE-FO satellite missions
Opis:
The article presents the reviewed and summarised research activities of the Polish research groups on gravimetry and gravity field modelling in the period of 2019–2022. It contains the results of absolute gravity surveys for the maintenance of the international gravity reference level in Poland and Europe, and for geodynamic research with an emphasis on metrological aspects. It also contains relative gravimetry issues as well as the results of marine gravity surveys in the southern Baltic Sea. Non-tidal gravity changes were extensively investigated. Long-term gravity variations were monitored at the Borowa Gora Geodetic-Geophysical Observatory and in a few other locations in Poland. The contribution of gravimetric records to seismic studies was investigated. Temporal variations of the gravity field from GRACE (Gravity Recovery and Climate Experiment) and GRACE-FO (GRACE Follow-On) data, in particular, deformations of the Earth’s surface as well as temporal variations of heights, total water storage and groundwater storage were investigated. Moreover, GRACE-based products and the performance of monthly Global Geopotential Models (GGMs) were a subject of research. GGMs developed in last years were evaluated. The research on developing new approaches in geoid modelling and their validation was conducted. New regional and local geoid models were determined for Poland and Ethiopia. The use of different techniques for estimating the absolute sea level at sites of the selected network in the Baltic Sea was investigated.
Źródło:
Advances in Geodesy and Geoinformation; 2023, 72, 2; art. no. e46, 2023
2720-7242
Pojawia się w:
Advances in Geodesy and Geoinformation
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
FET input voltage amplifier for low frequency noise measurements
Autorzy:
Achtenberg, Krzysztof
Mikołajczyk, Janusz
Bielecki, Zbigniew
Powiązania:
https://bibliotekanauki.pl/articles/221854.pdf
Data publikacji:
2020
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
low noise amplifier
low frequency noise measurements
field effect transistors
FET voltage noise
FET input amplifier
Opis:
The paper presents a low noise voltage FET amplifier for low frequency noise measurements. It was built using two stages of an op amp trans impedance amplifier. To reduce voltage noise, eight-paralleled low noise discrete JFETs were used in the first stage. The designed amplifier was then compared to commercial ones. Its measured value of voltage noise spectral density is around 24 nV/√Hz, 3 nV/√Hz, 0.95 nV/√Hz and 0.6 nV/√Hz at the frequency of 0.1, 1, 10 and 100 Hz, respectively. A -3dB frequency response is from ~20 mHz to ~600 kHz.
Źródło:
Metrology and Measurement Systems; 2020, 27, 3; 531-540
0860-8229
Pojawia się w:
Metrology and Measurement Systems
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Problemy syntezy pól elektromagnetycznych na potrzeby budowy przetwornika pierwotnego przepływomierza elektromagnetycznego do kanału otwartego
Problems of electromagnetic fields synthesis in a case of primary transducer for electromagnetic flow meter for open channel constructions
Autorzy:
Michalski, A.
Sienkiewicz, J.
Watral, Z.
Powiązania:
https://bibliotekanauki.pl/articles/208339.pdf
Data publikacji:
2009
Wydawca:
Wojskowa Akademia Techniczna im. Jarosława Dąbrowskiego
Tematy:
pole elektromagnetyczne
pomiary przepływu
przetworniki pomiarowe
przepływomierz elektromagnetyczny
electromagnetic field
flow measurements
measurement transducer
electromagnetic flow meter
Opis:
W artykule przedstawiono typowe konstrukcje przetworników pierwotnych wraz z syntetyczną analizą podstawowych problemów konstrukcyjnych i jakościowych. Wynikiem przedstawionej analizy jest propozycja zmodyfikowanej procedury projektowania kształtu cewki wzbudzającej zapewniającej minimalizację kosztów budowy przy jednoczesnej poprawie jej głównych parametrów. Proponowane rozwiązanie opiera się na znanym warunku stałości wektora wagi w strefie pomiarowej, ale jego realizacja będzie odmienna od wcześniejszych, znanych konstrukcji.
Typical constructions of a primary transducer for flow meters dedicated to open channels, associated with a simplified analysis of metrological quality are presented. As a result of this analysis, the authors propose a modified design procedure of an excited coil, which provides the cost minimization and quality improvement. The proposed solution is based on very well known condition, homogeneous distribution of weight vector in a measurement zone, but the realization is different from previously known procedures.
Źródło:
Biuletyn Wojskowej Akademii Technicznej; 2009, 58, 1; 383-393
1234-5865
Pojawia się w:
Biuletyn Wojskowej Akademii Technicznej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analiza i pomiary pól magnetycznych w otoczeniu elektrycznych urządzeń przemysłowych dużej mocy
Analysis and measurements of magnetic fields nearby electric power devices
Autorzy:
Gonscz, D.
Powiązania:
https://bibliotekanauki.pl/articles/157974.pdf
Data publikacji:
2007
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
pomiary przemiennych pól magnetycznych
ekspozycja w polu magnetycznym
measurements of alternate magnetic fields
exhibition in the magnetic field
Opis:
Publikacja jest zwartym opracowaniem na temat zagadnień związanych z analizą i metodyką badań przemiennych pól magnetycznych, wykonywanych na potrzeby oceny narażeń pracowników na ekspozycję w polu magnetycznym w środowisku przemysłowym. Praca obejmuje aspekty techniczne poprawnego wykonywania pomiarów oddziaływań magnetycznych, charakterystykę narzędzi pomiarowych oraz uwagi dotyczące inter-pretacji wyników w odniesieniu do aktualnych norm i przepisów. Szczególną uwagę zwrócono na sposób wyboru miejsc i pionów pomiarowych w bliskim otoczeniu źródeł pól magnetycznych. Praca zawiera również zestawienia dopuszczalnych poziomów oddziaływań magnetycznych z uwzględnieniem stref ochronnych.
The analysis and methods of research of alternate magnetic fields in industrial environment are described in the paper. Described problems concern the workers' exhibition in the magnetic field on the work positions. A selected type of instruments for magnetic measurements are presented. The limit values of magnetic induction and the limit values of intensity of magnetic field are shown in tab. 1. The established standard protective zones are marked in this table too. A technical aspects of measurement processes and a methods of result interpretations are explained. The most measurement problems and essentials error sources are pointed.
Źródło:
Pomiary Automatyka Kontrola; 2007, R. 53, nr 12, 12; 85-87
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Pole elektromagnetyczne - źródła, regulacje i pomiary
Electromagnetic field - sources, regulations and measurements
Autorzy:
Pawlak, R.
Powiązania:
https://bibliotekanauki.pl/articles/317582.pdf
Data publikacji:
2018
Wydawca:
Instytut Łączności - Państwowy Instytut Badawczy
Tematy:
pole elektromagnetyczne
PEM
ochrona środowiska
ICNIRP
GSM
UMTS
LTE
5G
SAR
zalecenie 1999/519/EC
ekspozycja na pole elektromagnetyczne
pomiary szerokopasmowe
pomiary selektywne
electromagnetic field
EMF
environment protection
Council Recommendation 1999/519/EC
human exposure to electromagnetic field
broadband EMF measurements
selective EMF measurements
Opis:
W artykule przedstawiono podstawowe problemy związane ze środowiskiem elektromagnetycznym, naturalnymi i wytwarzanymi przez człowieka źródłami pola elektromagnetycznego (PEM). Następnie omówiono zagadnienia prawnej ochrony człowieka i środowiska przed PEM, zarówno na poziomie wymagań europejskich, jak i polskich. Scharakteryzowano wymagania zapisane w rozporządzeniu Ministra Środowiska z dnia 30 października 2003 r. odnoszące się do wartości dopuszczalnych poziomów PEM w środowisku i metod sprawdzania dotrzymania tych poziomów, jednocześnie wskazując na istotne różnice w stosunku do unijnego zalecenia 1999/519/EC. Szczegółowo omówiono sposoby wykonywania pomiarów PEM w środowisku, ze szczególnym uwzględnieniem pomiarów selektywnych częstotliwościowo w dziedzinie kodowej. Na koniec zwrócono uwagę na problem wyznaczania poziomów PEM w sieciach 5G.
In the article, in the form of introduction, problems related to the electromagnetic environment, natural and man-made sources of electromagnetic field (EMF) were presented. Next, the issues of legal protection of human and the environment against EMF were discussed, both at the level of European and Polish requirements. The requirements stated in the Ministry of Environment Decree of 30 October 2003 regarding the permissible levels of electromagnetic fields in the environment and methods of verifying compliance with these levels were characterized, while indicating significant differences with the Council Recommendation 1999/519/EC. Methods of performing electromagnetic field measurements in the environment have been discussed in detail, with particular emphasis on frequency-selective measurements in the code domain. Finally, attention was paid to the problem of determining the levels of electromagnetic fields in 5G networks.
Źródło:
Telekomunikacja i Techniki Informacyjne; 2018, 1-2; 26-37
1640-1549
1899-8933
Pojawia się w:
Telekomunikacja i Techniki Informacyjne
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Polish magnetic measurements in the Baltic — history and prospects
Polskie pomiary magnetyczne na Bałtyku — historia i perspektywy
Autorzy:
Welker, E.
Powiązania:
https://bibliotekanauki.pl/articles/222663.pdf
Data publikacji:
2015
Wydawca:
Akademia Marynarki Wojennej. Wydział Dowodzenia i Operacji Morskich
Tematy:
Earth's magnetic field
magnetic measurements at sea
secular variations of a geomagnetic field
repeat stations
isopods
pole magnetyczne Ziemi
pomiary magnetyczne na morzu
zmiany wiekowe pola geomagnetycznego
punkty wiekowe
izopody
Opis:
The progress in observation technology and navigation systems, as well as improvements in appliances used for carrying out magnetic measurements require a knowledge of the Earth’s magnetic field distribution, not only on land but also in water regions. In order to update the results of marine magnetic measurements the knowledge of specific variations in a water region is required. It is connected with establishing a network of repeat stations taking regular measurements of three independent components of the Earth’s magnetic field. Charts contained in the Atlas of the Baltic Magnetic Charts in which the discovered anomalies in a geomagnetic field are marked can be useful in designing such a network.
Rozwój technik obserwacyjnych i systemów nawigacyjnych oraz ulepszenie aparatury do pomiarów magnetycznych wymagają znajomości rozkładu pola magnetycznego Ziemi nie tylko na lądzie, ale i na akwenach. Do bieżących aktualizacji wyników morskich pomiarów magnetycznych potrzebna jest wiedza na temat zmian rocznych (wiekowych) na danym akwenie. Wiąże się to z założeniem morskiej sieci punktów wiekowych (repeat stations) i regularnymi na niej pomiarami trzech niezależnych składowych pola magnetycznego Ziemi. W zaprojektowaniu takiej sieci mogą być pomocne mapy z Atlasu map magnetycznych Bałtyku, na których uwidocznione są wykryte anomalie pola geomagnetycznego.
Źródło:
Zeszyty Naukowe Akademii Marynarki Wojennej; 2015, R. 56 nr 2 (201), 2 (201); 75-85
0860-889X
Pojawia się w:
Zeszyty Naukowe Akademii Marynarki Wojennej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Pomiary emisji elektromagnetycznej na stanowisku cięcia plazmowego
Measurements of electromagnetic emission on the Plasma Arc Cutting stand’s
Autorzy:
Sadowski, M.
Powiązania:
https://bibliotekanauki.pl/articles/274789.pdf
Data publikacji:
2015
Wydawca:
Sieć Badawcza Łukasiewicz - Przemysłowy Instytut Automatyki i Pomiarów
Tematy:
cięcie plazmowe
pole elektromagnetyczne
pomiary pól elektromagnetycznych
bezpieczeństwo i higiena pracy
plasma arc cutting
electromagnetic field
measurements of electromagnetic fields
occupational safety and health
Opis:
Urządzenia cięcia plazmowego są obecnie powszechnie wykorzystywane w wielu procesach technologicznych związanych z wytwarzaniem konstrukcji metalowych. Są one także źródłem zakłóceń elektromagnetycznych. Mogą wpływać na kompatybilność elektromagnetyczną sąsiadujących urządzeń, doprowadzając, w przypadku przekroczenia wartości granicznych, do zakłóceń ich pracy. Z punktu widzenia przepisów o bezpieczeństwie i higienie pracy, emisje promieniowania elektromagnetycznego są także czynnikiem środowiskowym powodującym narażenia personelu obsługującego urządzenia. Z tej przyczyny ważne jest prowadzenie pomiarów emisji promieniowanych od urządzeń przemysłowych. W artykule omówiono problematykę promieniowania elektromagnetycznego emitowanego podczas pracy urządzeń do cięcia plazmowego. Przedstawiona została budowa plazmotronu (palnika plazmowego) oraz jego zasada działania. Przeprowadzone zostały pomiary emisji pola elektromagnetycznego podczas pracy przecinarki plazmowej na jej stanowisku roboczym. Wyniki pomiarów zostały zaprezentowane i przeanalizowane. Pozwoliły one sformułować wniosek, że występujące w trakcie cięcia plazmowego emisje pola elektromagnetycznego nie przekraczają wartości granicznych i nie powodują zagrożenia dla personelu obsługującego urządzenie.
Plasma cutting machines are now widely used in many technological processes involved in the manufacture of metal structures. They are also a source of electromagnetic interferences. It may influence the electromagnetic compatibility of nearby devices, leading, in the case of exceeding limits, to disruption of their work. From the point of view of the occupational health and safety regulations’, emissions of electromagnetic fields are also factor causing exposure of operating personnel. For this reason, it is important to conduct measurements of radiated emissions from industrial equipment. The article discusses the issues of electromagnetic radiation emitted during operation of the plasma cutting machine. The construction of plasma torch and its principle of operation are presented. The measurement results of the emitted electromagnetic fields are presented and analyzed. The results lead to the conclusion that electromagnetic field emissions from plasma arc cutter are safe for technical personnel.
Źródło:
Pomiary Automatyka Robotyka; 2015, 19, 4; 75-78
1427-9126
Pojawia się w:
Pomiary Automatyka Robotyka
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Nondestructive investigation of wall thinning in ferromagnetic material by Magnetic adaptive testing: influence of yoke size
Nieniszczące badanie przewężenia materiałów ferromagnetycznych za pomocą adaptacyjnych testów magnetycznych: wpływ rozmiaru jarzma
Autorzy:
Vértesy, G.
Powiązania:
https://bibliotekanauki.pl/articles/107904.pdf
Data publikacji:
2018
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
electromagnetic nondestructive testing
wall thinning
magnetic hysteresis measurements
magnetic adaptive testing
magnetic field simulation
elektromagnetyczne badania nieniszczące
przewężenie materiału
pomiary histerezy magnetycznej
magnetyczne testy adaptacyjne
symulacja pola magnetycznego
Opis:
Magnetic adaptive testing is a powerful way of nondestructive evaluation. Minor magnetic hysteresis loops are systematically measured and evaluated. In the present work this technique was applied for detection of local thinning of ferromagnetic plates. The same plate with a given artificial slot was tested by different size magnetizing yokes. A definite maximum of magnetic descriptors was found, as a function of yoke size, which made possible the optimization of the yoke size for a given size of defect. The character of the maximum also revealed that the measurement is not sensitive for the geometrical parameters: the same yoke is suitable for detection of defects in a wide range. It was proved by simulation that the change of the magnetic flux density in the yoke − due to local thinning − was responsible for the observed effect. Good correlation was found between simulation and experimental data. The result of this work will help to find the optimal parameters of the experimental arrangement.
Magnetyczne testy adaptacyjne są skutecznym sposobem oceny nieniszczącej. W ich trakcie mniejszościowe pętle histerezy magnetycznej są systematycznie mierzone i oceniane. W niniejszej pracy zastosowano tę technikę do wykrywania miejscowego przewężenia płytek ferromagnetycznych. Ta sama płyta ze sztucznymi defektami została zbadana przy wykorzystaniu jarzma magnetyzującego o różnych rozmiarach. Określono maksymalną liczbę deskryptorów magnetycznych, zależnych od wielkości jarzma, co umożliwiło optymalizację rozmiaru jarzma dla danej wielkości defektu. Uzyskana charakterystyka ujawniła również brak wrażliwości wyników pomiaru na parametry geometryczne: to samo jarzmo nadaje się do wykrywania defektów w szerokim zakresie. Udowodniono, że za obserwowany efekt odpowiedzialna była zmiana gęstości strumienia magnetycznego w jarzmie - będąca wynikiem lokalnego przerzedzania. Stwierdzono dobrą korelację między symulacją a danymi eksperymentalnymi. Uzyskane wyniki umożliwią wyznaczenie optymalnych parametrów układu pomiarowego.
Źródło:
Badania Nieniszczące i Diagnostyka; 2018, 2; 45-49
2451-4462
2543-7755
Pojawia się w:
Badania Nieniszczące i Diagnostyka
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Narażenie na pole elektromagnetyczne w przestrzeni pracy podczas użytkowania urządzeń nadawczych systemów radiokomunikacyjnych : metoda pomiaru pola elektromagnetycznego in situ – wymagania szczegółowe
Exposure to the electromagnetic field in the work space during the use of transmitting devices of radiocommunication systems : the method of in situ measurements of the electromagnetic field – specific requirements
Autorzy:
Bieńkowski, P.
Aniołczyk, H.
Karpowicz, J.
Kieliszek, J.
Powiązania:
https://bibliotekanauki.pl/articles/137598.pdf
Data publikacji:
2017
Wydawca:
Centralny Instytut Ochrony Pracy
Tematy:
radiokomunikacja
urządzenia nadawcze
anteny
pole elektromagnetyczne
pomiary
metoda rekomendowana
środowisko pracy
bezpieczeństwo i higiena pracy
radiocommunication
transmitting devices
antennas
electromagnetic field
measurements
recommended method
work environment
occupational safety and health
Opis:
W prawie pracy określono obowiązek rozpoznania i oceny zagrożeń elektromagnetycznych w otoczeniu urządzeń i systemów radiokomunikacyjnych będących źródłami pola elektromagnetycznego (pole-EM). W rozporządzeniu Ministra Rodziny, Pracy i Polityki Społecznej z dnia 29 czerwca 2016 r. w sprawie bezpieczeństwa i higieny pracy przy pracach związanych z narażeniem na pole elektromagnetyczne, wśród typowych źródeł tego pola wymieniono „nadawcze systemy tele- i radiokomunikacyjne” oraz „stacje bazowe systemów telefonii komórkowej” (DzU 2016, poz. 950, zm. poz. 2284; zał. 1., poz. 4. i 5.). Do urządzeń radiokomunikacyjnych zalicza się również „telefony komórkowe, bezprzewodowe i urządzenia bezprzewodowe krótkiego zasięgu” (DzU 2016, poz. 950, zm. poz. 2284; zał. 1., poz. 3.), które jako sprzęt powszechnego użytku, niewymagający pozwolenia radiokomunikacyjnego, nie są przedmiotem niniejszego artykułu. Urządzania i systemy radiokomunikacyjne stanowią obecnie jedne z najliczniejszych źródeł pola-EM, a podczas emisji w otoczeniu anten i niektórych innych elementów systemu występuje pole-EM stref ochronnych. Systemy radiokomunikacyjne są najczęściej bezobsługowe, jednak wymagają okresowych kontroli, regulacji i konserwacji, a tym samym w ich otoczeniu można wyróżnić przestrzeń pracy. Warunki narażenia pracujących na pole-EM podczas użytkowania systemów radiokomunikacyjnych wymagają okresowej kontroli, wykonanej zgodnie z rekomendowanymi i zwalidowanymi metodami, celem rozpoznania zagrożeń elektromagnetycznych i podjęcia odpowiednich środków ochronnych (DzU 2011, poz. 166; DzU 2016, poz. 950, zm. poz. 2284). Metody pomiarów pola-EM w zakresie koniecznym do realizacji wspomnianych wymagań nie są obecnie znormalizowane. W związku z tym, celem relacjonowanej w niniejszym artykule pracy było opracowanie metody rekomendowanej do pomiaru parametrów pola-EM in situ w przestrzeni pracy, podczas użytkowania urządzeń radiokomunikacyjnych. Rekomendowana metoda pomiarów została opracowana na podstawie szczegółowego rozpoznania charakterystyki narażenia na pole-EM w otoczeniu typowych urządzeń i systemów radiokomunikacyjnych eksploatowanych w Polsce: w otoczeniu systemów antenowych oraz nadajników stacji bazowych telefonii komórkowej, nadajników radiowych i telewizyjnych małych mocy oraz radiowo-telewizyjnych centrów nadawczych (RTCN). W pracy opierano się na pomiarach własnych autorów oraz opracowaniach literaturowych i protokołach z pomiarów kontrolnych pola-EM. Na podstawie wyników przeprowadzonych badań stwierdzono, że oprócz pierwotnych źródeł pola-EM w postaci anten (w niektórych przypadkach również nadajników oraz elementów toru antenowego), w przestrzeni pracy w ich otoczeniu występują również wtórne źródła pola-EM: metalowe konstrukcje (drabiny, barierki, ogrodzenia, elementy nośne anten, rynny, zwody uziomów) oraz anteny odbiorcze lub nadawcze wyłączone z nadawania, ale będące w obszarze oddziaływania pola-EM anten nadawczych. W artykule przedstawiono opracowaną metodę pomiarów pola-EM w przestrzeni pracy w otoczeniu stacjonarnych, wymagających pozwoleń radiowych, nadawczych urządzeń i systemów radiokomunikacyjnych oraz omówiono najistotniejsze przyczyny niepewności wyników pomiaru pola-EM przy omawianych urządzeniach.
Labour law sets out the obligation to identify and evaluate electromagnetic hazards in the vicinity of radiocommunication equipment and installations emitting an electromagnetic field (EM-field). Following the regulation of the Ministry of Labour, which established provisions regarding health and safety regarding the EM-field, the "broadcasting tele- and radiocommunication systems” and “mobile phone base stations” have been mentioned among the typical sources of an EM-field (Regulation...., OJ 2016 item 950, amended by item 2284, Annex 1, items 4 and 5). Radiocommunication devices also include “mobile and cordless phones and wireless short distance devices (Regulation...., OJ 2016 item 950, amended by item 2284, Annex 1, item 3), which are devices in common use that do not require a radiocommunication permit, and so are not the subject of this article. Today, radiocommunication devices and systems are among the most common sources of the EM- -field, and while emissions the EM-field of protective zones exists in the vicinity of antennas and some other elements of such systems. The radiocommunication systems are usually operation-free, though they require adjusting and maintenance so workspaces may be identified in their vicinity. The conditions of the workers’ exposure to the EM-field while using radiocommunication systems must undergo periodic inspections made according to the recommended and validated methods, in order to identify electromagnetic hazards and to take appropriate protective measures (Regulation..., Journal of Laws 2011, item 166; Regulation..., OJ 2016 item 950, amended by item 2284). The methods of measuring the EM- -field to the extent necessary to meet these requirements are currently not standardised. Therefore, the aim of the work presented in this article was to develop a recommended method for measuring the parameters of the EM-field in situ in the workspace, while using radiocommunication devices. The recommended measurement method is based on a detailed investigation of the characteristics of exposure to the EM-field surrounding typical radiocommunication devices and systems operated in Poland in the vicinity of systems of antennas and transmitters of mobile phone base stations, broadcasting transmitters of radio and low power television and radio-television broadcasting centres. The work is based on the own results of measurements, as well as published literature and reports from inspection measurements of the EM-field. Based on the results of the study, it was shown that, besides the antennas, which create primary sources of EM-field (in some cases also transmitters and elements of the antenna feeder), in the workspace in their vicinity there are also secondary sources of EM-field: metal structures (ladders, handrails, fences, antennas supports, pipes and groundings) and receiving or inactivated transmitting antennas exposed to the EM-field from active transmitting antennas. In the article, the worked out method is shown for measuring the EM-field in the work space in the vicinity of stationary transmitting radio-communication devices and systems, requiring a radiocommunication permit. The most important sources of uncertainty concerning EM-field measurements near these devices were also discussed.
Źródło:
Podstawy i Metody Oceny Środowiska Pracy; 2017, 2 (92); 89-131
1231-868X
Pojawia się w:
Podstawy i Metody Oceny Środowiska Pracy
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Efekty termiczne w ciele człowieka wywołane szybkozmiennym polem elektromagnetycznym
Thermal effects in the human body induced by the quick-variable electromagnetic field
Autorzy:
Przytulski, A.
Powiązania:
https://bibliotekanauki.pl/articles/275041.pdf
Data publikacji:
2010
Wydawca:
Sieć Badawcza Łukasiewicz - Przemysłowy Instytut Automatyki i Pomiarów
Tematy:
pole elektromagnetyczne w.cz.
mikrofale
efekty termiczne
głębokość wnikania fali elektromagnetycznej
częstotliwość rezonansowa
pomiary promieniowania w.cz.
HF electromagnetic field
microwaves
thermal effects
penetration depth of electromagnetic wave
resonance frequency
HF radiation measurements
Opis:
W artykule opisano jeden z bardziej znanych i zbadanych efektów w ciele człowieka, powodowany szybkozmiennym polem elektromagnetycznym. Wskazano na czynniki decydujące o ilości pochłanianego promieniowania, które bardzo często nie są uwzględniane przy rozpatrywaniu tego zagadnienia. Opisano następstwa efektów termicznych oraz sposoby ochrony przed mikrofalami.
One of the best known and investigated effects in the human body induced by the quick-variable electromagnetic field has been described in the paper. At the same time, some factors have been shown which determine the amount of absorbed radiation but often they are not taken into consideration when this problem is being examined. The consequences of thermal effects and some possibilities for protecting people against microwaves have also been described.
Źródło:
Pomiary Automatyka Robotyka; 2010, 14, 12; 145-149
1427-9126
Pojawia się w:
Pomiary Automatyka Robotyka
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Problematyka oceny w budynkach użyteczności publicznej oddziaływania na pracowników promieniowania elektromagnetycznego systemów radiokomunikacyjnych
The issues of assessing the impact of electromagnetic radiation of radiocommunication systems on workers in public buildings
Autorzy:
Gryz, Krzysztof
Karpowicz, Jolanta
Zradziński, Patryk
Powiązania:
https://bibliotekanauki.pl/articles/23352071.pdf
Data publikacji:
2022
Wydawca:
Centralny Instytut Ochrony Pracy
Tematy:
promieniowanie elektromagnetyczne
pomiary
środowisko pracy
ekspozycja pracujących
rejestratory pola elektrycznego
systemy radiokomunikacyjne
bezpieczeństwo i higiena pracy
inżynieria środowiska
electromagnetic radiation
measurements
working exposure
electric field exposimeters
radiocommunication systems
occupational safety and health
environmental engineering
Opis:
Przedstawiono charakterystykę systemów radiokomunikacyjnych emitujących promieniowanie elektromagnetyczne (PR-EM) rozpoznane w budynkach użyteczności publicznej. Zaprezentowano wyniki badań PR-EM w budynkach użyteczność publicznej w środowisku miejskim, charakteryzującym się największym zagęszczeniem anten nadawczych oraz PR-EM o najbardziej złożonym widmie częstotliwości. Wykazano, że głównymi źródłami ekspozycji na PR-EM w budynkach są zewnętrzne stacje bazowe sieci telefonii mobilnej 4G/5G (pasma downlink: GSM 900 oraz LTE 800, 1800, 2100 i 2600) i naziemnych nadajników radiowo-telewizyjnych (FM i TV VHF i UHF), o ile są one zlokalizowane na terenie miasta, oraz wewnętrzne sieci lokalnej łączności między urządzeniami i dostępu do Internetu (Wi-Fi 2,4GHz i 5GHz). Wyniki badań wykazały, że w typowych warunkach lokalizacji zewnętrznych anten systemów radiokomunikacyjnych ekspozycja na PR-EM w budynkach użyteczności publicznej nie przekraczała dolnego limitu strefy pośredniej (ekspozycja pomijalna określona przez prawo pracy). W przypadku lokalizacji wewnątrz budynków źródeł PR-EM mogą one mieć najistotniejszy udział w profilu występującej tam ekspozycji. Zaprezentowano również kluczowe elementy postępowania podczas oceny i ograniczania PR-EM w budynkach użyteczności publicznej.
The characteristics of radiocommunication systems as the main sources of exposure to electromagnetic radiation (EMR) in public utility buildings are presented. The results of EMR research in public utility buildings in an urban environment characterized by the highest density of transmitting antennas and EMR with the most complex frequency spectrum are presented. It has been shown that the main sources of exposure to EMR in buildings are external base stations of the 4G/5G mobile communications network (downlink: GSM 900 and LTE 800, 1800, 2100 and 2600 bands), terrestrial radio and television transmitters (FM and TV VHF and UHF) if they are located in the city, and internal networks of local communication between devices and access to the Internet (Wi-Fi 2.4GHz and 5GHz). The investigation results showed that under typical conditions of location of external antennas of radiocommunication systems, exposure to EMR in public buildings did not exceed the lower limit of the intermediate zone where protection of workers against EMR is applicable (negligible exposure defined by labour law). In the case of EMR sources located inside buildings, they may have a significant contribution to the exposure profile. The key elements of the procedure for EMR assessments and limiting EMR radiation in public buildings were also presented.
Źródło:
Podstawy i Metody Oceny Środowiska Pracy; 2022, 4 (114); 99--109
1231-868X
Pojawia się w:
Podstawy i Metody Oceny Środowiska Pracy
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wave analysis for two-point measurements in the Polish EEZ of the Baltic Sea
Analiza falowania dla pomiarów dwupunktowych na obszarze polskiej wyłącznej strefy ekonomicznej Morza Bałtyckiego
Autorzy:
Kapiński, J.
Powiązania:
https://bibliotekanauki.pl/articles/111423.pdf
Data publikacji:
2016
Wydawca:
Instytut Morski w Gdańsku
Tematy:
simultaneous two-point wave measurements
waves at open sea
ADCP instruments
Baltic Sea
Polish EEZ
spatial variability of wave field
statistical analysis of sea waves
jednoczesne pomiary ruchu falowego w dwóch punktach
fale na otwartym morzu
przyrządy pomiarowe typu ADCP
Morze Bałtyckie
Polska Wyłączna Strefa Ekonomiczna
przestrzenna zmienność pola falowego
statystyczna analiza fal morskich
Opis:
Results of field measurements of surface gravity waves conducted for two neighbouring points at the Baltic Sea were compared. However, deep-water conditions are met there, noticeable differences for wave heights, periods and directions can be observed. In some cases they increase with the magnitudes of wave parameters, in other ones they remain constant. These two-point measurements indicate that the wave field can be differential even within small aquatic sites of the open sea, which, for instance, can have an effect on offshore structure stability or on a wave energy productivity. The aim of this paper is to point out the importance of this issue.
W pracy porównano wyniki pomiarów terenowych na Morzu Bałtyckim dla grawitacyjnych fal powierzchniowych przeprowadzonych w dwóch sąsiadujących ze sobą punktach. Mimo, że były tam spełnione warunki głębokowodne, zaobserwowano znaczne różnice wysokości, okresów i kierunków fal. W niektórych przypadkach rosły one wraz ze wzrostem wielkości analizowanych parametrów falowych, w innych zaś pozostawały niezmienne. Wykonane dwupunktowe pomiary wskazują na fakt, że pola falowe mogą się zauważalnie różnić nawet na małych obszarach otwartego morza, co na przykład może mieć wpływ na stabilność konstrukcji pełnomorskich lub wydajność generatorów energii falowej. Zwrócenie uwagi na to zagadnienie jest głównym celem niniejszego artykułu.
Źródło:
Biuletyn Instytutu Morskiego w Gdańsku; 2016, 31, 1; 67-72
1230-7424
2450-5536
Pojawia się w:
Biuletyn Instytutu Morskiego w Gdańsku
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-30 z 30

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies