Tytuł:
Wide-band optical fibre system for investigation of MEMS and NEMS deflection
Autorzy:
Orłowska, K.
Świątkowski, M.
Kunicki, P.
Słupski, P.
Sankowska, A.
Gotszalk, T.
Powiązania:
https://bibliotekanauki.pl/articles/221558.pdf
Data publikacji:
2014
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
fibre optic sensors
amplitude detection
intensity detection
MEMS/NEMS deflection measurement
Opis:
In this work the construction of experimental setup for MEMS/NEMS deflection measurements is presented. The system is based on intensity fibre optic detector for linear displacement sensing. Furthermore the electronic devices: current source for driving the light source and photodetector with wide-band preamplifier are presented.
Źródło:
Metrology and Measurement Systems; 2014, 21, 3; 381-388
0860-8229
Pojawia się w:
Metrology and Measurement Systems
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Fibre-optic sensor for simultaneous measurement of thickness and refractive index of liquid layers
Autorzy:
Marzejon, Marcin
Karpienko, Katarzyna
Mazikowski, Adam
Jędrzejewska-Szczerska, Małgorzata
Powiązania:
https://bibliotekanauki.pl/articles/220419.pdf
Data publikacji:
2019
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
fibre-optic
sensors
interferometry
Fabry-Pérot interferometer
Opis:
In this paper, we present a fibre-optic sensor for simultaneous measurement of refractive index and thickness of liquid layers. We designed an experimental low-coherence setup with two broadband light sources and an extrinsic fibre-optic Fabry-Pérot interferometer acting as the sensing head. We examined how the refractive index of a liquid film and its thickness affect spectrum at the output of a fibre-optic interferometer. We performed a series of experiments using two light sources and only one sensing head. The spectra were collected in ranges of 1220-1340 nm and 1500-1640 nm. The obtained results show that using two spectra recorded simultaneously for two wavelength ranges enables to determine thickness in a range of 50-500 μm, and refractive index of a liquid film in a range of 1.00-1.41 RIU using only one sensing head.
Źródło:
Metrology and Measurement Systems; 2019, 26, 3; 561-568
0860-8229
Pojawia się w:
Metrology and Measurement Systems
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-2 z 2

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies