Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "fala ciepła" wg kryterium: Temat


Wyświetlanie 1-4 z 4
Tytuł:
Fale ciepła i chłodu w środkowej Polsce na przykładzie Łodzi
Waves of warmth and coldness in Central Poland on the example of Łódź
Autorzy:
Wibig, Joanna
Powiązania:
https://bibliotekanauki.pl/articles/945283.pdf
Data publikacji:
2007
Wydawca:
Uniwersytet Łódzki. Wydawnictwo Uniwersytetu Łódzkiego
Tematy:
temperatura dobowa
fala ciepła
fala chłodu
cyrkulacja atmosferyczna
ekstremum termiczne
Opis:
The aim of this work is to analyze the waves of warmth and coldness in central part of Poland basing on a daily maximum and minimum temperature in Łódź between 1931 and 2006. Warm and cold periods were distinguished following daily maximum temperature course (warm and cold days) and daily minimum temperature course (warm and cold nights). A particular day was involved in warm (cold) period, if its daily temperature was higher (lower) than average +1.28 (-l.28) of standard deviation within this calendar day. The value of l.28 was chosen because it counterparts percentile of 90% (10%) if we assume that temperature distribution is normal. The trends of seasonal and annual changeability of the number of cold and warm days and nights as well as maximum length of warm and cold waves were estimated by Sen's method. The most frequently observed were the short waves, such as one- or two days long (Fig. 3 and 9). The average of day numbers, within at least three day-long waves and an their average lasting time of the longest waves had distinct annual cycle with its maximum in summer and minimum in winter. However, the absolute maxima of the waves lengths fell on winter half-year. The longest waves were 18 and 17 days. For comparison, the lengths of the warm and cold nights periods were significantly shorter and were about II and 14 days. The longest cold waves were slightly longer than equivalent waves of warmth. The following years: 1962, 1989, 1992, 1994, 2000, 2002 and 2006 are the years of particularly long warm periods or years of a great number of warm days, and are grouped in last 20 years of analyzed series with the exception of 1962, which represents series center. On the other hand, the years, during which cold waves were exceptionally long or those, which were characterized by a great number of cold days and nights (1954, 1956, 1963, 1979, 1996) were gathered during first 30s of the analyzed period. In spite of this, only some of studied series have statistically significant trend. Lasting time of the longest wave of warmth increased significantly in winter (0.28 of the day per ID years), while the number of waves of warmth grew in summer (0.33 of the day per ID years) and during the whole year (1.79 of the day per ID years). If it is about warm nights, the lasting time of the longest wave increased significantly in winter (0.17 of the day per 10 years) and in autumn (0.20 of the day per 10 years), while the number of the days increased significantly in summer (0.36 of the day per 10 years) and within the whole year (1.61 of the day per 10 years). The length of the longest wave of cold days significantly decreased in winter (0.18 of the day per ID years) and the number of cold days in a year decreased in 0.87 of the day per 10 years. In case of cold nights the lasting time of the longest wave shortened in winter (0.17 of the day per 20 years) and during the whole year (0.2 of the day per 10 years), while the number of cold nights in the year decreased in 1.43 days per 10 years and 0.43 of the day per ID years in spring. The influence of the atmospheric circulation either in macroscale or mesoscale on frequency and intensity of extreme thermal events in Poland is visible only in winter, however it explains no more than 25% of their changeability. Better results are obtained by composite method, which allows to single out such synoptic situations, which favor maintaining strong positive and negative thermal anomalies. Thermal conditions of central Poland primarily depend on baric centers, which centers locate in country's proximity (Fig. 14-17). The correlations between number of days during periods of warm days and nights, and maximum length of waves and northern hemisphere's temperature are positive and statistically significant for all seasons except summer (fable 6). Nonetheless, no more than 25% of the changes might be the direct results of big-scale temperature changes, the rest is influenced by regional or even local factors. The correlations between number of days during periods of cold days and nights and maximum length of waves and northern hemisphere's temperature are negative and statistically insignificant.
Źródło:
Acta Universitatis Lodziensis. Folia Geographica Physica; 2008, 8
1427-9711
2353-6063
Pojawia się w:
Acta Universitatis Lodziensis. Folia Geographica Physica
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wykorzystanie kalorymetrycznej metody pomiarowej w badaniach strumieni ciepła w silniku z wirującą falą detonacyjną
Use of calorimeter method for heat flux measurement in rotaring detonation
Autorzy:
Sobczak, K.
Powiązania:
https://bibliotekanauki.pl/articles/212673.pdf
Data publikacji:
2014
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Lotnictwa
Tematy:
strumienie ciepła
silnik z wirującą falą detonacyjną
model wymiany ciepła
heat flux
rotating detonation engine (RDE)
model of heat transfer
Opis:
W pracy przedstawiono opis obliczeń projektowych i wykorzystanie metody kalorymetrycznej do wyznaczenie obciążeń cieplnych w komorze spalania silnika wykorzystującego zjawisko wirującej detonacji. Oszacowanie strumienia ciepła na jaki narażone będą ścianki komory spalania to jeden z kluczowych parametrów z jakim należy się zmierzyć w trakcie opracowywania jednostki napędowej. Z tego względu opracowano stanowisko badawcze, dzięki któremu możliwe będzie wyznaczenie wartości strumieni ciepła, na podstawie zmiany entalpii czynnika chłodzącego. W oparciu o wyniki eksperymentalne opracowany zostanie model wymiany ciepła, który wykorzystany zostanie podczas rozwijania kodów nume-rycznych.
The work will be focused on heat transfer to the combustion chamber wall of continuous detonation wave engine. Like in conventional rocket engines, heat flux is a design key factor. Implementation of semi-empirical model of heat transfer (calculation of heat transfer coefficient) into REFLOPS and collected experimental data will give a basis for comparison and verification. These results will be important for further development of numerical codes.
Źródło:
Prace Instytutu Lotnictwa; 2014, 1 (234) March 2014; 109-115
0509-6669
2300-5408
Pojawia się w:
Prace Instytutu Lotnictwa
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Silne fale termiczne w Lublinie
Strong thermal waves in Lublin
Autorzy:
Krzyżewska, Agnieszka
Nowosad, Marek
Dobek, Mateusz
Powiązania:
https://bibliotekanauki.pl/articles/578349.pdf
Data publikacji:
2016
Wydawca:
Łódzkie Towarzystwo Naukowe
Tematy:
silna fala chłodu
silna fala ciepła
temperatura powietrza
Lublin
strong cold wave
strong warm wave
air temperature
Opis:
W niniejszej pracy wprowadzono definicje silnych i bardzo silnych fal termicznych. Jako kryteria przyjęto odchylenia średniej dobowej temperatury powietrza od średniej wieloletniej odpowiednio o 2 i 3 odchylenia standardowe przez trzy kolejne dni. Badania przeprowadzono dla Lublina (1952–2010). W analizowanym okresie wystąpiły 54 silne fale chłodu i 24 silne fale ciepła. Silne fale chłodu częściej pojawiały się w pierwszej połowie analizowanego wielolecia. Zauważono zwiększoną częstość silnych fal ciepła w XXI wieku. Kryteria bardzo silnej fali termicznej spełniły 4 fale chłodu i 1 fala ciepła. Silne fale chłodu występowały od 16 września do 7 czerwca, zaś silne fale ciepła – od 17 marca do 17 listopada. Dodatkowo analizowano przebieg temperatury powietrza w czasie szczególnie upalnego lata 2015, kiedy to wystąpiły 4 silne fale ciepła. Nie zanotowano natomiast w czasie tego lata bardzo silnej fali termicznej.
In this paper, the definitions of strong and very strong thermal waves have been introduced. The deviations of mean daily temperature from the long-term average of the air temperature by 2 and 3 standard deviations for three consecutive days were applied as criteria for thermal waves. The study was conducted for Lublin (1952–2010). In the analyzed period there were 54 strong cold waves and 24 strong warm waves. Strong cold waves often appeared in the first half of the analyzed period. An increase in the incidence of strong warm waves was noted in the XXI century. The criteria for a very strong warm wave were met by 4 cold waves and 1 warm wave. Strong cold waves occurred from 16 September to 7 June, and the strong warm waves – from 17 March to 17 November. Additionally, we analyzed the course of air temperature during a particularly hot summer in 2015 when 4 severe warm waves occurred. A very strong warm wave did not occur during that summer.
Źródło:
Acta Geographica Lodziensia; 2016, 104; 11-19
0065-1249
Pojawia się w:
Acta Geographica Lodziensia
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Dinamika častic ognetušaŝego poroška na puti k očagu požara pri impulʹsnom sposobe podači ego v zonu goreniâ
The Dynamics of Dry Chemical Powder Particles Towards the Fire Source During Their Pulse Feeding into the Combustion Zone
Dynamika cząsteczek proszku gaśniczego podczas podawania go w kierunku pożaru metodą impulsową
Autorzy:
Kitsak, A. I.
Powiązania:
https://bibliotekanauki.pl/articles/372752.pdf
Data publikacji:
2018
Wydawca:
Centrum Naukowo-Badawcze Ochrony Przeciwpożarowej im. Józefa Tuliszkowskiego
Tematy:
dry chemical extinguishing system
dry chemical powder
velocity of the dry chemical powder
power of fire source
heat wave
modułowa proszkowa instalacja gaśnicza
proszek gaśniczy
prędkość proszka gaśniczego
moc źródła pożaru
fala ciepła
Opis:
ABSTRACT Objective: Currently, the pulse-type dry chemical extinguishing system (DCES) is extensively used for extinguishing fires. These units generally consist of a control junction and powder extinguishing modules (PEM) filled with fire extinguishing powder and gas pumped into the module under the high pressure. Giving extinguishing powder from the PEM in the fire source is carried out when exposed to the heated air of the thermal column generating lift. The magnitude of this force depends on the power of fire and intensity of air change in the room. The efficiency of fire extinguishing with the DCES in these conditions will be determined not only by the powder extinguishing ability but also its dynamic characteristics when approaching the fire. In the design of pulse-type fire extinguishing systems using PEMs it should be considered that during testing PEMs the dynamics of the gas powder mixture released from the module is impacted by the air resistance and the lift of the heated gases from the thermal column from the fire source. Aim: The aim of this work is to determine the ratio of the unit weight of dry chemical extinguishing powder depending on the distance from the nozzle of the DCES for the defined pneumatic and loading characteristics of the system, disperse parameters of dry chemical powder and the fire power. Project and methods: To reach the aim of the study, a mathematical model approach was applied for the flow process the extinguishing substance from the DCES and its movement in open-air space towards the fire. Results: A mathematical model was developed to calculate the movement dynamics of the gas-powder mixture in an open-air space towards the fire source under specific performance parameters of the DCES and the power of the fire. A correlation for estimating the extinguishing powder particle velocity at different distances from the DCES nozzle during their movement towards the fire of a given power was obtained. An experimental study of the dynamics of the front of the powder mixture ejected from the pulse-type PEM was performed. The analysis of the results showed their satisfactory level of compliance with numerical calculations. Conclusions: The obtained results can be used for analyses of pulse-type PEMs with a goal of assessing the spatial and energy parameters of fires which can be extinguished using this method. The results can be used during the design of such installations in order to specify the pneumatic and load parameters of the module associated with the given technical characteristics of the extinguishing agent, the assumed power level of the fire source and the height of the PEM.
Wprowadzenie: W obecnych czasach modułowe proszkowe instalacje gaśnicze typu impulsowego są powszechnie wykorzystywane do gaszenia pożarów. Instalacje te składają się zazwyczaj z modułów sterowania oraz modułów gaszenia proszkowego, które wypełnione są proszkiem gaśniczym i gazem pod wysokim ciśnieniem. Na proszek gaśniczy podawany z modułów gaszenia proszkowego do ogniska pożaru oddziałuje nagrzane powietrze komina termicznego, generujące siłę nośną. Wielkość tej siły zależy od mocy pożaru i intensywności wentylacji pomieszczenia. W takich warunkach efektywność gaszenia pożaru za pomocą instalacji proszkowej będzie zależna nie tylko od skuteczności gaśniczej proszku, lecz także od jego charakterystyk dynamicznych, podczas gdy przemieszcza się w stronę źródła pożaru. Przy projektowaniu modułowych proszkowych instalacji gaśniczych typu impulsowego, a także podczas badań modułów gaszenia proszkowego należy uwzględniać, że na dynamikę ruchu mieszaniny gazowo-proszkowej wyzwalanej z modułu wpływają oporność powietrza oraz siła nośna rozgrzanych gazów komina termicznego ze źródła pożaru. Cel: Celem pracy jest wyznaczenie zależności między prędkością jednostkowej masy proszku gaśniczego a lokalizacją otworu wylotowego modułu gaszenia proszkowego typu impulsowego w warunkach określonych charakterystyk pneumatycznych i obciążeniowych modułu, parametrów dyspersji proszku i mocy pożaru. Projekt i metody: Aby zrealizować wyznaczony cel, zastosowano metodę modelowania matematycznego ubytku środka gaśniczego po jego wyzwoleniu oraz jego ruchu w kierunku źródła pożaru w przestrzeni otwartej. Wyniki: Opracowano model matematyczny dynamiki ruchu mieszaniny gazowo-proszkowej, odbywającego się na przestrzeni otwartej w kierunku źródła pożaru oraz w określonych warunkach parametrów pracy modułów gaszenia proszkowego oraz energii pożaru. Otrzymano zależność do oceny prędkości cząsteczek proszku gaśniczego w różnych odległościach od otworu wylotowego modułu gaszenia proszkowego, podawanego w stronę pożaru o określonej mocy. Przeprowadzono badania eksperymentalne dynamiki przemieszczania się frontu gazowo-proszkowej mieszaniny wyrzucanej przez moduły gaszenia proszkowego typu impulsowego. Analiza otrzymanych wyników świadczy o zadowalającej zgodności z obliczeniami numerycznymi. Wnioski: Otrzymane wyniki mogą być wykorzystane przy przeprowadzaniu badań modułów gaszenia proszkowego typu impulsowego mających na celu ocenę parametrów przestrzennych i energetycznych pożarów, które mogą być nimi ugaszone. Rezultaty można wykorzystać również podczas projektowania tego rodzaju instalacji w celu określenia parametrów pneumatycznych i obciążeniowych modułu związanych ze znanymi technicznymi charakterystykami środka gaśniczego, zakładanych wartości mocy źródła pożaru i wysokości umieszczenia modułu gaszenia proszkowego.
Źródło:
Bezpieczeństwo i Technika Pożarnicza; 2018, 49, 1; 76-85
1895-8443
Pojawia się w:
Bezpieczeństwo i Technika Pożarnicza
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-4 z 4

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies