Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "exoskeleton robot" wg kryterium: Temat


Wyświetlanie 1-4 z 4
Tytuł:
Robust continuous third-order finite time sliding mode controllers for exoskeleton robot
Autorzy:
Fellag, Ratiba
Guiatni, Mohamed
Hamerlain, Mustapha
Achour, Noura
Powiązania:
https://bibliotekanauki.pl/articles/1845025.pdf
Data publikacji:
2021
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
exoskeleton robot
higher order
sliding control
homogeneous
robust
trajectory tracking
rehabilitation
Opis:
In this work, continuous third-order sliding mode controllers are presented to control a five degrees-of-freedom (5-DOF) exoskeleton robot. This latter is used in physiotherapy rehabilitation of upper extremities. The aspiration is to assist the movements of patients with severe motor limitations. The control objective is then to design adept controllers to follow desired trajectories smoothly and precisely. Accordingly, it is proposed, in this work, a class of homogeneous algorithms of sliding modes having finite-time convergence properties of the states. They provide continuous control signals and are robust regardless of non-modeled dynamics, uncertainties and external disturbances. A comparative study with a robust finite-time sliding mode controller proposed in literature is performed. Simulations are accomplished to investigate the efficacy of these algorithms and the obtained results are analyzed.
Źródło:
Archive of Mechanical Engineering; 2021, LXVIII, 4; 395-414
0004-0738
Pojawia się w:
Archive of Mechanical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
From the treadmill to the exoskeleton. Evolution of mechanical gait assistance methods
Od bieżni do egzoszkieletów – ewolucja metod mechanicznego wspomagania chodu
Autorzy:
Rojek, Anna
Zwolińska-Mirek, Katarzyna
Oleksy, Łukasz
Cygoń, Krzysztof
Michałek, Adrian
Janiszewska, Natalia
Mika, Anna
Powiązania:
https://bibliotekanauki.pl/articles/1808040.pdf
Data publikacji:
2015
Wydawca:
Akademia Wychowania Fizycznego im. Bronisława Czecha w Krakowie
Tematy:
Gait
e-education
robot
Exoskeleton
chód
reedukacja
egzoszkielet
Opis:
Limited independent walking and the resulting disabilities are a serious issue for a growing group of patients. These patients are often dependent on a wheelchair, or are bedridden until the end of their lives. For this reason, the development of gait re-education methods and devices for mechanical gait assistance are very important elements in maintaining or regaining a high quality of daily and social life. New technologies allow for the construction of devices that support the rehabilitation process, which reduce the workload of therapists and ensure the best execution of the patients’ movement patterns. This paper presents the development of devices used for the mechanical support of gait starting from the simplest ones like treadmills or standing frames, through stationary robots, to the most technologically advanced ones, i.e. exoskeletons. An exoskeleton is a wearable robot which supports, or in some cases, substitutes for the user’s own movements. The first attempts to create such devices were undertaken 40 years ago. This paper discusses their clinical applications and their effectiveness in gait re-education based on the existing scientific evidence. These new technologies in gait re-education are now becoming an integral part of the rehabilitation process.
Źródło:
Medical Rehabilitation; 2015, 19(4); 25-33
1427-9622
1896-3250
Pojawia się w:
Medical Rehabilitation
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Bilateral teleoperation system for a mini crane
Autorzy:
Herbin, Paweł
Woźniak, Marcin
Powiązania:
https://bibliotekanauki.pl/articles/135104.pdf
Data publikacji:
2019
Wydawca:
Akademia Morska w Szczecinie. Wydawnictwo AMSz
Tematy:
human robot interface
machine control
mechatronic system
exoskeleton
hri
hydraulic crane
feedforward control
Opis:
In this paper, two automatic mini-crane control systems have been compared; utilizing feedback as well as both feedback and feedforward structures. The proposed control systems were implemented in a Master-Slave system to provide intuitive control for a mini-crane by human muscles. The control systems that have been designed were tested on constructions with similar structures i.e. an upper limb exoskeleton and a mini-crane with two joints, but using different actuation systems. The mini-crane had hydraulic actuators, whereas the exoskeleton was equipped with electrical actuators.
Źródło:
Zeszyty Naukowe Akademii Morskiej w Szczecinie; 2019, 57 (129); 63-69
1733-8670
2392-0378
Pojawia się w:
Zeszyty Naukowe Akademii Morskiej w Szczecinie
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Mechanical and hardware architecture of the semi-exoskeleton arm rehabilitation robot
Projekt mechaniczny i architektura systemu sterowania semi-egzoszkieletalnego robota przeznaczonego do rehabilitacji kończyny górnej
Autorzy:
Gmerek, A.
Powiązania:
https://bibliotekanauki.pl/articles/139702.pdf
Data publikacji:
2013
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
robot
arm rehabilitation
EMG
exoskeleton
upper-extremity rehabilitation
upper limb rehabilitation
ARR
egzoszkielet
rehabilitacja kończyny górnej
Opis:
This paper deals with mechanical and hardware design of a robot, used for the rehabilitation of upper extremities. It has been called ARR-1 (Arm Rehabilitation Robot). The robot has a semi-exoskeleton structure. This means that some parts of the robot fit closely to the human arm (an orthosis), but the weight of the construction does not load patient’s body. The device is used for the whole arm rehabilitation, but active joints are only situated in glenohumeral and elbow joints. The robot is electrically actuated.
Artykuł opisuje mechanikę oraz część sprzętową systemu sterowania robota przeznaczonego do rehabilitacji kończyny górnej. Robot został nazwany Arm Rehabilitation Robot - ARR i charakteryzuje się strukturą semi-egzoszkieletalną. Oznacza to, że część aktywna przylega do ciała pacjenta, a jego struktura kinematyczna przypomina kończynę górną, ale waga robota nie obciąża pacjenta. Urządzenie może być używane do rehabilitacji całej kończyny górnej, ale aktywne stopnie swobody znajdują się w stawach barkowo-obojczykowym oraz łokciowym. Robot jest napędzany silnikami elektrycznymi.
Źródło:
Archive of Mechanical Engineering; 2013, LX, 4; 557-574
0004-0738
Pojawia się w:
Archive of Mechanical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-4 z 4

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies