Tytuł:
Estimation of equivalent power system impedance in normal conditions
Wyznaczanie impedancji zastępczej systemu elektroenergetycznego w warunkach normalnych
Autorzy:
Małyszko, O.
Nowakowski, R.
Zeńczak, M.
Powiązania:
https://bibliotekanauki.pl/articles/156976.pdf
Data publikacji:
2007
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
system elektroenergetyczny
moc zwarciowa
impedancja zastępcza
monitoring
power system
short-circuit power
equivalent impedance
on-line control
Opis:
The paper presents method of estimation of equivalent power system impedance. The method based on the correlation method which uses natural variability of the voltage level in the network nodes. To find the value of equivalent power system resistance and reactance the Lyapunov exponents were used. Equivalent impedance of power system is the base to determination of short-circuit currents and short-circuit power. On-line control over the short-circuit power in key nodes of power system might provide system dispatchers with an important piece of information.
Ważnym parametrem systemu elektroenergetycznego (SEE) jest poziom mocy zwarciowej w poszczególnych węzłach. Znajomość wartości mocy zwarciowej pozwala na określenie wartości spodziewanych prądów zwarciowych. Jest to niezbędne do prawidłowego doboru urządzeń w fazie projektowania systemu oraz do doboru nastaw automatyki zabezpieczeniowej. Moc zwarciowa zależy od impedancji zastępczej SEE. Wartość tej impedancji zależy od liczby generatorów, transformatorów, linii elektroenergetycznych oraz ich mocy, impedancji i układu połączeń między nimi. Wartość tej impedancji nie jest wielkością stałą w czasie. Zmiany mogą wynikać zarówno ze zmiany układu połączeń w systemie (zmiany krótkookresowe) jak też z rozwoju SEE (zmiany długookresowe). W artykule przedstawiono koncepcję wyznaczania impedancji zastępczej SEE w warunkach ruchowych. Przedstawiona metoda bazuje na zmienności poziomu napięcia w węzłach pomiarowych SEE spowodowanej przez losowe zmiany prądu obciążenia wynikające z losowej zmiany obciążenia. Zgodnie z proponowaną metodą do wyznaczenia impedancji systemu konieczny jest pomiar wartości skutecznej prądu, napięcia, mocy czynnej i dodatkowo wyznaczenie sumy wykładników Lapunowa.
Źródło:
Pomiary Automatyka Kontrola; 2007, R. 53, nr 6, 6; 11-13
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Assessing system impedance based on data regrouping
Autorzy:
Xu, Shuangting
Xiao, Xianyong
Wang, Yang
Wu, Jun
Powiązania:
https://bibliotekanauki.pl/articles/1848954.pdf
Data publikacji:
2021
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
system impedance
passive method
Thevenin equivalent
power system
Opis:
In recent years, assessing supply system impedance has become crucial due to the concerns on power quality and the proliferation of distributed generators. In this paper, a novel method is shown for passive measurement of system impedances using the gapless waveform data collected by a portable power quality monitoring device. This method improves the overall measurement accuracy through data regrouping. Compared with the traditional methods that use the consecutive measurement data directly, the proposed method regroups the data to find better candidates with less flotation on the system side. Simulation studies and extensive field tests have been conducted to verify the effectiveness of the proposed method. The results indicate that the proposed method can serve as a useful tool for impedance measurement tasks performed by utility companies.
Źródło:
Metrology and Measurement Systems; 2021, 28, 1; 191-208
0860-8229
Pojawia się w:
Metrology and Measurement Systems
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Assessing system impedance based on data regrouping
Autorzy:
Xu, Shuangting
Xiao, Xianyong
Wang, Yang
Wu, Jun
Powiązania:
https://bibliotekanauki.pl/articles/1848965.pdf
Data publikacji:
2021
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
system impedance
passive method
Thevenin equivalent
power system
Opis:
In recent years, assessing supply system impedance has become crucial due to the concerns on power quality and the proliferation of distributed generators. In this paper, a novel method is shown for passive measurement of system impedances using the gapless waveform data collected by a portable power quality monitoring device. This method improves the overall measurement accuracy through data regrouping. Compared with the traditional methods that use the consecutive measurement data directly, the proposed method regroups the data to find better candidates with less flotation on the system side. Simulation studies and extensive field tests have been conducted to verify the effectiveness of the proposed method. The results indicate that the proposed method can serve as a useful tool for impedance measurement tasks performed by utility companies.
Źródło:
Metrology and Measurement Systems; 2021, 28, 1; 191-208
0860-8229
Pojawia się w:
Metrology and Measurement Systems
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The frequency analysis of real resistors in relative values
Autorzy:
Kubisa, S.
Warsza, Z. L.
Powiązania:
https://bibliotekanauki.pl/articles/114711.pdf
Data publikacji:
2016
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
resistor
AC models
equivalent circuits
impedance
parameters
frequency errors
Opis:
Three-element impedance including the resistance R as the main parameter and the residual parameters: serial inductance L and a parallel capacitance C is used as an equivalent circuit of resistor. It is the basic model of resistor for AC current. The real component of this impedance is not equal to the resistance R for the DC current, and there is the imaginary component. Both components depend on the frequency. Variants of the model with four different connections are also analyzed. Patterns of the relative resistor frequency errors in the generalized form, i.e. as a function of the relative values of resistance and frequency of the circuit are determined and their curves are given. Considerations are illustrated by few numerical examples
Źródło:
Measurement Automation Monitoring; 2016, 62, 3; 80-86
2450-2855
Pojawia się w:
Measurement Automation Monitoring
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Badanie właściwości olejów napędowych metodą elektrochemicznej spektroskopii impedancyjnej
Evaluation of diesel fuel properties using electrochemical impedance spectroscopy
Autorzy:
Macioszek, Ł.
Mazur, K.
Powiązania:
https://bibliotekanauki.pl/articles/158236.pdf
Data publikacji:
2014
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
spektroskopia impedancyjna
obwód zastępczy
olej napędowy
electrochemical impedance spectroscopy
equivalent circuit
diesel fuel
Opis:
W pracy podjęto próbę zbadania olejów napędowych metodą elektrochemicznej spektroskopii impedancyjnej. Materiałem do badań było pięć próbek zimowych olejów napędowych typu premium, zakupionych na stacjach różnych dostawców. Na podstawie wyników pomiaru impedancji stworzono elektryczny obwód zastępczy dla celki z olejem napędowym, a następnie wyznaczono wartości elementów modelu dla przebadanych próbek. Dokonano oceny jakości przyjętych modeli na podstawie parametru χ2 oraz błędów dopasowania poszczególnych elementów. Uzyskane wyniki pozwalają stwierdzić, że metoda spektroskopii impedancyjnej może pozwolić na badanie niektórych właściwości olejów napędowych metodami elektrochemicznymi. Zauważalne jest zróżnicowanie otrzymywanych wyników w zależności od dostawcy, a co za tym idzie składu chemicznego badanego oleju napędowego.
In the paper there is made an attempt to evaluate diesel fuels using electrochemical impedance spectroscopy (EIS) and to verify experimentally that it can be used to characterize these fuels. Five samples of winter premium diesels from different vendors were examined. The impedance of diesel fuels was measured in the frequency range of 0.01 Hz - 5 kHz with the use of the Princeton Applied Research laboratory system for EIS. The measurement results are presented in the form of Bode plot in Fig. 2 and Nyquist plot in Fig. 3. A commonly used electrical equivalent circuit for the measuring cell (Fig. 1) was modified according to the collected measurements. Diesel fuels can be treated as dielectrics, hence a better representation of their electrochemical nature can be modeled without RΩ element in their equivalent circuit. Then, using the EIS Spectrum Analyzer the values of the circuit elements were fitted to the measurement results. The fitting results and modeling errors are presented in Table 1. The quality of fitted values was evaluated by both χ2 coefficient and relative errors of individual components. The test findings show that EIS can be used to determine some of the electrochemical properties of diesel fuels. One can note a diversity in the obtained results that depend on the supplier and hence the exact chemical composition of the tested diesel. Thus to be able to use the EIS method in the practical research, it is necessary to gather the measuring results of reference samples to be able to compare current findings.
Źródło:
Pomiary Automatyka Kontrola; 2014, R. 60, nr 8, 8; 626-628
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Impedance spectroscopy method used for the unpasteurized beer microbiological contamination degree assessment
Autorzy:
Macioszek, Łukasz
Rybski, Ryszard
Andrzejczak-Grządko, Sylwia
Konkol, Olga
Powiązania:
https://bibliotekanauki.pl/articles/2202883.pdf
Data publikacji:
2022
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
impedance spectroscopy
equivalent circuit
beer contamination
microorganisms
spektroskopia impedancyjna
równoważny obwód
zanieczyszczenie piwa
mikroorganizmy
Opis:
The main aim of the below presented work was to investigate the possibility of using impedance spectroscopy in the unpasteurized beer microbial contamination degree assessment. Advantages of the impedance spectroscopy method, a negligible number of similar published results as well as their practical aspect make the research important. Four different types of beers were investigated which were unfit for consumption due to improper storage and were heavily microbiologically contaminated. Their impedance was measured in the frequency range from 0.1 Hz to 1 kHz before and after centrifugation. Based on the measured values, an innovative electrical equivalent circuit was proposed and the parameters of the circuit elements were fitted. The obtained results show significant differences (23 up to 35%) in the values of resistance modelling the diffusion phenomenon. Such large changes, resulting from the removal of biomass from the samples, prove the validity of impedance spectroscopy in the study of the properties of unpasteurized beer. According to the authors, it would be possible to use the proposed methodology during the production of beer. With some limitations, it should aid in the early detection of microbial contamination.
Źródło:
Chemical and Process Engineering; 2022, 43, 4; 461--469
0208-6425
2300-1925
Pojawia się w:
Chemical and Process Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Calculating the Dynamic Impedances of Foundations and their Effect on the Seismic Response of Structures: Analytical and Numerical Study
Autorzy:
Boulkhiout, Radhwane
Messast, Salah
Powiązania:
https://bibliotekanauki.pl/articles/2051714.pdf
Data publikacji:
2021
Wydawca:
Uniwersytet Zielonogórski. Oficyna Wydawnicza
Tematy:
soil-structure interaction
finite element method
substructure method
impedance functions
CONAN
equivalent static method
soil densification
interakcja gleba-struktura
metoda elementów skończonych
równoważna metoda statyczna
zagęszczanie gleby
Opis:
This study evaluates the movement of a frame built on soft soil under seismic excitation taking into account soil-structure interaction. First, the study was evaluated using the finite element method, then, by using a substructure method which modelled the soil using springs and dampers in a linear and nonlinear study. Rheological models were determined using impedance functions, calculated using a numerical program CONAN. These dynamic impedances are shown in the displacement vector of a three-degrees-of-freedom frame, which was calculated on the basis of lateral forces distributed over the structure height using the equivalent static method. In this regard, two different calculation norms were chosen; RPA2003 and UBC97. Finally, a parametric study was carried out, based on the effects of soil densification and the foundation geometry on the response of the RC frame.
Źródło:
Civil and Environmental Engineering Reports; 2021, 31, 2; 178-217
2080-5187
2450-8594
Pojawia się w:
Civil and Environmental Engineering Reports
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Capacitor sensor impedance parameter measurement method for the degradation degree evaluation of hydraulic oil in the process of thermal oxidation
Metoda pomiaru parametrów impedancyjnych czujnika pojemnościowego do oszacowania stopnia degradacji oleju hydraulicznego w procesie termoutleniania
Autorzy:
Umiński, W.
Powiązania:
https://bibliotekanauki.pl/articles/256420.pdf
Data publikacji:
2013
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Technologii Eksploatacji - Państwowy Instytut Badawczy
Tematy:
oil degradation
capacitive sensor
capacitor impedance
quality factor
dissipation factor
equivalent series resistance
microprocessor LCR meter
stan oleju
czujnik pojemnościowy
impedancja kondensatora
współczynnik stratności
rezystancja strat kondensatora
mikroprocesorowy miernik pojemności
Opis:
The paper describes a diagnostic method for the evaluation of the condition of hydraulic oil with the use of the dependence between oil degradation and changes in capacitor sensor impedance components. A series of new capacitive sensors has been developed, and impedance components measurements of hydraulic oil HL-46 laboratory oxidative degradation were conducted by means of microprocessor-based LCR meter. Preliminary laboratory measurement results have shown that equivalent series resistance ESR and quality factor Q of a capacitor series circuit model are most suitable for the evaluation of the condition of oil. The measurements indicated the best capacitive sensor sensitivity.
W artykule przedstawiono metodę badawczą umożliwiającą ocenę zmian stanu oleju hydraulicznego w procesie termoutleniania poprzez pomiar za pomocą mikroprocesorowego miernika LCR, zmian parametrów impedancyjnych zastępczego układu szeregowego lub równoległego czujnika pojemnościowego (określanego również jako kondensator pomiarowy) zanurzonego w oleju. Opisano konstrukcję czujnika oraz zaprezentowano wybrane wyniki wstępnych pomiarów parametrów impedancyjnych dla różnych typów i rodzajów czujników dla próbek oleju hydraulicznego HL-46 poddanych laboratoryjnemu termoutlenianiu. Wyniki pomiarów pozwoliły wytypować zarówno parametry impedancyjne, jak i wykonanie czujnika w aspekcie najlepszej detekcji zmian stanu oleju.
Źródło:
Problemy Eksploatacji; 2013, 3; 147-158
1232-9312
Pojawia się w:
Problemy Eksploatacji
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-8 z 8

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies