Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "energy performance" wg kryterium: Temat


Tytuł:
3-D simulation of vertical-axial tidal current turbine
Autorzy:
Zhang, Z.
Ma, Y.
Jiang, J.
Liu, W.
Ma, Q.
Powiązania:
https://bibliotekanauki.pl/articles/260421.pdf
Data publikacji:
2016
Wydawca:
Politechnika Gdańska. Wydział Inżynierii Mechanicznej i Okrętownictwa
Tematy:
tidal current energy
vertical-axial turbine
hydrodynamic performance
CFD
numerical simulation
3-D effect
Opis:
Vertical-axial tidal current turbine is the key for the energy converter, which has the advantages of simple structure, adaptability to flow and uncomplex convection device. It has become the hot point for research and application recently. At present, the study on the hydrodynamic performance of vertical-axial tidal current turbine is almost on 2-D numerical simulation, without the consideration of 3-D effect. CFD (Computational Fluid Dynamics) method and blade optimal control technique are used to improve accuracy in the prediction of tidal current turbine hydrodynamic performance. Numerical simulation of vertical-axial tidal current turbine is validated. Fixed and variable deflection angle turbine are comparatively studied to analysis the influence of 3-D effect and the character of fluid field and pressure field. The method, put the plate on the end of blade, of reduce the energy loss caused by 3-D effect is proposed. The 3-D CFD numerical model of vertical-axial tidal current turbine hydrodynamic performance in this study may provide theoretical, methodical and technical reference for the optimal design of turbine.
Źródło:
Polish Maritime Research; 2016, 4; 73-83
1233-2585
Pojawia się w:
Polish Maritime Research
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
A comprehensive review on energy and exergy analysis of solar air heaters
Autorzy:
Ghritlahre, Harish Kumar
Sahu, Piyush Kumar
Powiązania:
https://bibliotekanauki.pl/articles/240351.pdf
Data publikacji:
2020
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
solar energy
energy
exergy analysis
solar air heater
thermal performance
Opis:
For economic growth of nation, the energy plays an important role. The excessive use of fossil fuels results the increase in global warming and depleting the resources. Due to this reason, the renewable energy sources are creating more attraction for researchers. In renewable energy sector, solar energy is the most abundant and clean source of energy. In solar thermal systems, solar air heater (SAH) is the main system which is used for heating of air. As it is simple in construction and cheaper in cost, it is of main interest for the researchers. The concept of first law and second law of thermodynamics is used for the study of the energy and exergy analysis respectively. The energy analysis is of great importance for the study of process effectiveness while the exergetic analysis is another significant concept to examine the actual behavior of process involving various energy losses and internal irreversibility. For efficient utilization of solar energy, the exergy analysis is very important tool for optimal design of solar air heaters. The aim of the present work is to review the works related to energy and exergy analysis of various types of solar air heaters and to find out the research gap for future work.
Źródło:
Archives of Thermodynamics; 2020, 41, 3; 183-222
1231-0956
2083-6023
Pojawia się w:
Archives of Thermodynamics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
A method for evaluatingthe performance of a marine piston internal combustion engine used as the main engine on a ship during its voyage in different sailing conditions
Autorzy:
Girtler, J.
Powiązania:
https://bibliotekanauki.pl/articles/259375.pdf
Data publikacji:
2010
Wydawca:
Politechnika Gdańska. Wydział Inżynierii Mechanicznej i Okrętownictwa
Tematy:
engine operation
combustion engine performance evaluation
interpretation of energy conversion
Newton-Leibniz formula
model of engine operation
Opis:
A method is presented for evaluating the performance of piston internal combustion engines used as the main engines on sea-going ships and acting in typical operating conditions. These conditions are described taking into account the performance area of engines of this type. The presented method provides opportunities for calculating the numerical effect of the action using the integral calculus. The above effect is presented as a physical quantity expressed by a number with the metric unit called the joule-second. Proposed is the use of types of integrands (which are functional dependences of the energy converted in these engines on time) which make it possible to use the second fundamental theorem of calculus justifying the use of the Newton-Leibniz formula. The object of the analysis is the process of changes of the energy converted in the internal combustion engines during their operation, described with the aid of a deterministic model of the real process taking into account its sample realisation.
Źródło:
Polish Maritime Research; 2010, 4; 31-38
1233-2585
Pojawia się w:
Polish Maritime Research
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
A new data mining approach for power performance verification of an on-shore wind farm
Autorzy:
Castellani, F.
Garinei, A.
Terzi, L.
Astolfi, D.
Moretti, M.
Lombardi, A.
Powiązania:
https://bibliotekanauki.pl/articles/328750.pdf
Data publikacji:
2013
Wydawca:
Polska Akademia Nauk. Polskie Towarzystwo Diagnostyki Technicznej PAN
Tematy:
wind energy
renewable energy
wind turbine performance
data mining
SCADA database
control systems
fault diagnosis
performance optimization
wind turbine power output
Opis:
Monitoring wind energy production is fundamental to improve the performances of a wind farm during the operational phase. In order to perform reliable operational analysis, data mining of all available information spreading out from turbine control systems is required. In this work a SCADA (Supervisory Control And Data Acquisition) data analysis was performed on a small wind farm and new post-processing methods are proposed for condition monitoring of the aerogenerators. Indicators are defined to detect the malfunctioning of a wind turbine and to select meaningful data to investigate the causes of the anomalous behaviour of a turbine. The operating state database is used to collect information about the proper power production of a wind turbine and a number map has been codified for converting the performance analysis problem into a purely numerical one. Statistical analysis on the number map clearly helps in detecting operational anomalies, providing diagnosis for their reasons. The most operationally stressed turbines are systematically detected through the proposal of two Malfunctioning Indices. Results demonstrate that a proper selection of the SCADA data can be very useful to measure the real performances of a wind farm and thus to define optimal repair/replacement and preventive maintenance policies that play a major role in case of energy production.
Źródło:
Diagnostyka; 2013, 14, 4; 35-42
1641-6414
2449-5220
Pojawia się w:
Diagnostyka
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
A statistical approach for selecting buildings for experimental measurement of HVAC needs
Statystyczna metoda wyboru budynków badawczych na potrzeby analizy systemów HVAC
Autorzy:
Malinowski, P.
Ziembicki, P.
Powiązania:
https://bibliotekanauki.pl/articles/396766.pdf
Data publikacji:
2017
Wydawca:
Uniwersytet Zielonogórski. Oficyna Wydawnicza
Tematy:
k-means method
HVAC system performance
energy consumption
building characteristics
metoda k-średnich
systemy HVAC
zużycie energii
charakterystyka energetyczna budynków
Opis:
This article presents a statistical methodology for selecting representative buildings for experimentally evaluating the performance of HVAC systems, especially in terms of energy consumption. The proposed approach is based on the k-means method. The algorithm for this method is conceptually simple, allowing it to be easily implemented. The method can be applied to large quantities of data with unknown distributions. The method was tested using numerical experiments to determine the hourly, daily, and yearly heat values and the domestic hot water demands of residential buildings in Poland. Due to its simplicity, the proposed approach is very promising for use in engineering applications and is applicable to testing the performance of many HVAC systems.
W artykule przedstawiono statystyczną metodę wyboru budynków reprezentatywnych pod względem charakterystyki energetycznej oraz cech wbudowanych systemów grzewczych wentylacyjnych i klimatyzacyjnych. Proponowane podejście opiera się na metodzie k-średnich. Algorytm dla tej metody jest stosunkowo prosty, co pozwala na łatwe wdrożenie i nie wymaga dużego nakładu (kosztu) obliczeniowego. Sposób ten może być stosowany dla dużych ilości danych. Metodą k-średnich badano dane pozyskane w czasie inwentaryzacji obiektów oraz w wyniku symulacji komputerowych funkcjonowania budynków, zawierające m.in. roczne wartości zapotrzebowania na ciepło (symulowane z krokiem czasowym godzinnym). Z uwagi na względną prostotę metodyki oraz uzyskane bardzo dobre wyniki, proponowane podejście jest bardzo obiecujące dla zastosowań technicznych, w tym analiz budynków pod kątem systemów HVAC.
Źródło:
Civil and Environmental Engineering Reports; 2017, No. 24(1); 101-118
2080-5187
2450-8594
Pojawia się w:
Civil and Environmental Engineering Reports
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
A Study on the Propulsion Performance in the Actual Sea by means of Full-scale Experiments
Autorzy:
Kayano, J.
Yabuki, N.
Sasaki, N.
Hiwatashi, R.
Powiązania:
https://bibliotekanauki.pl/articles/116354.pdf
Data publikacji:
2013
Wydawca:
Uniwersytet Morski w Gdyni. Wydział Nawigacyjny
Tematy:
Propulsion Performance
Propulsion
mechanical engineering
Energy Efficiency Design Index (EEDI)
Ship Energy Efficiency Management Plan (SEEMP)
Energy Efficiency Operational Indicator (EEOI)
Self Propulsion Factors
Power Curves
Opis:
The IMO has adopted Energy Efficiency Design Index (EEDI), Ship Energy Efficiency Management Plan (SEEMP) and Energy Efficiency Operational Indicator (EEOI) in order to reduce GHG emissions from international shipping. And, the shipping industry is required to develop and improve the energy saving ship operation technologies to meet the above IMO guideline. The weather routing is one of the energy saving navigation technologies and widely adopted by oceangoing merchant ships. The effectiveness of the weather routing mainly depends on the accuracy of weather forecast data and the ship’s propulsion performance prediction. The propulsion performance in the actual sea is usually predicted using the Self Propulsion Factors obtained by model tests. It is necessary to understand the propulsion performance characteristics in the actual sea conditions for the improvement of propulsion performance prediction. From the above points of view, the authors performed full‐scale experiments using a training ship in order to investigate the propulsion performance characteristics in the actual sea. This paper describes the analysis results on the characteristics of Power Curves and Self Propulsion Factors under various weather and sea conditions.
Źródło:
TransNav : International Journal on Marine Navigation and Safety of Sea Transportation; 2013, 7, 4; 521-526
2083-6473
2083-6481
Pojawia się w:
TransNav : International Journal on Marine Navigation and Safety of Sea Transportation
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Active power losses and energy efficiency analysis of HPS lamps with electromagnetic control gear and electronic ballast under the sinusoidal and nonsinusoidal condition
Autorzy:
Sikora, Roman
Markiewicz, Przemysław
Rózga, Paweł
Powiązania:
https://bibliotekanauki.pl/articles/2173621.pdf
Data publikacji:
2021
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
HPS lamps
electromagnetic control gear
electronic ballast
energy performance indicator
road lighting
lampa HPS
układ sterowania elektromagnetyczny
balast elektroniczny
wskaźnik wydajności energetycznej
oświetlenie drogowe
Opis:
Outdoor lighting is an important element in creating an evening and nocturnal image of urban spaces. Properly designed and constructed lighting installations provide residents with comfort and security. One way to improve the energy efficiency of road lighting installation is to replace the electromagnetic control gear (ECG) with electronic ballasts (EB). The main purpose of this article is to provide an in-depth comparative analysis of the energy efficiency and performance of HPS lamps with ECG and EB. It will compare their performance under sinusoidal and nonsinusoidal voltage supply conditions for the four most commonly used HPS lamps of 70 W, 100 W, 150 W, and 250 W. The number of luminaires supplied from one circuit was determined based on the value of permissible active power losses. With the use of the DIALux program, projects of road lighting installation were developed. On this basis, energy performance indicators, electricity consumption, electricity costs, and CO 2 emissions were calculated for one-phase and three-phase installations. The obtained results indicate that an HPS lamp with EB is better than an HPS lamp with ECG in terms of energy quality, energy savings, and environmental impact. The results of this analysis are expected to assist in the choice of HPS lighting technology.
Źródło:
Bulletin of the Polish Academy of Sciences. Technical Sciences; 2021, 69, 3; art. no. e137194
0239-7528
Pojawia się w:
Bulletin of the Polish Academy of Sciences. Technical Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Active power losses and energy efficiency analysis of HPS lamps with electromagnetic control gear and electronic ballast under the sinusoidal and nonsinusoidal condition
Autorzy:
Sikora, Roman
Markiewicz, Przemysław
Rózga, Paweł
Powiązania:
https://bibliotekanauki.pl/articles/2128159.pdf
Data publikacji:
2021
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
HPS lamps
electromagnetic control gear
electronic ballast
energy performance indicator
road lighting
lampa HPS
układ sterowania elektromagnetyczny
balast elektroniczny
wskaźnik wydajności energetycznej
oświetlenie drogowe
Opis:
Outdoor lighting is an important element in creating an evening and nocturnal image of urban spaces. Properly designed and constructed lighting installations provide residents with comfort and security. One way to improve the energy efficiency of road lighting installation is to replace the electromagnetic control gear (ECG) with electronic ballasts (EB). The main purpose of this article is to provide an in-depth comparative analysis of the energy efficiency and performance of HPS lamps with ECG and EB. It will compare their performance under sinusoidal and nonsinusoidal voltage supply conditions for the four most commonly used HPS lamps of 70 W, 100 W, 150 W, and 250 W. The number of luminaires supplied from one circuit was determined based on the value of permissible active power losses. With the use of the DIALux program, projects of road lighting installation were developed. On this basis, energy performance indicators, electricity consumption, electricity costs, and CO 2 emissions were calculated for one-phase and three-phase installations. The obtained results indicate that an HPS lamp with EB is better than an HPS lamp with ECG in terms of energy quality, energy savings, and environmental impact. The results of this analysis are expected to assist in the choice of HPS lighting technology.
Źródło:
Bulletin of the Polish Academy of Sciences. Technical Sciences; 2021, 69, 3; e137194, 1--22
0239-7528
Pojawia się w:
Bulletin of the Polish Academy of Sciences. Technical Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
An Experimental Investigation into Improving the Performance of Thermoelectric Generators
Autorzy:
Alahmer, Ali
Khalid, Mohammad Bani
Beithou, Nabil
Borowski, Gabriel
Alsaqoor, Sameh
Alhendi, H.
Powiązania:
https://bibliotekanauki.pl/articles/2068454.pdf
Data publikacji:
2022
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
thermoelectric generator
liquid evaporation
TEG performance
enhancing power generation
waste energy harvesting
Opis:
Low-temperature heat sources have become increasingly popular in recent years, particularly for energy generation. The majority of thermal devices in the market (including devices using solar energy, geothermal energy, waste energy, and so on) transform heat into electricity indirectly, requiring mechanical work before producing power. Through the Seebeck effect, the technology that employs a thermoelectric generator (TEG) may directly transform heat energy into electricity. The TEG technology provides several advantages, including compactness, quietness, and the absence of moving components. TEGs have a low thermal and electrical efficiency, which is one of their main drawbacks. Therefore, the performance of a thermoelectric generator is improved by employing liquid evaporation heat transfer in this manuscript. The performance of the thermoelectric was examined experimentally and compared to the liquid evaporation mode under varied heat flux values and different modes of heat transfer in terms of free and forced convection with and without fins. The experimental results revealed that when compared to free convection without fins, adopting forced liquid evaporation convection would improve TEG voltage variation by 435.9%.
Źródło:
Journal of Ecological Engineering; 2022, 23, 3; 100--108
2299-8993
Pojawia się w:
Journal of Ecological Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analysis of High-Performance Near-threshold Dual Mode Logic Design
Autorzy:
Bikki, Pavankumar
Powiązania:
https://bibliotekanauki.pl/articles/226748.pdf
Data publikacji:
2019
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
CMOS logic
dual mode logic
dynamic mode
high performance
minimum energy point
near-threshold
Opis:
A novel dual mode logic (DML) model has a superior energy-performance compare to CMOS logic. The DML model has unique feature that allows switching between both modes of operation as per the real-time system requirements. The DML functions in two dissimilar modes (static and dynamic) of operation with its specific features, to selectively obtain either low-energy or high-performance. The sub-threshold region DML achieves minimum-energy. However, sub-threshold region consequence in performance is enormous. In this paper, the working of DML model in the moderate inversion region has been explored. The near-threshold region holds much of the energy saving of subthreshold designs, along with improved performance. Furthermore, robustness to supply voltage and sensitivity to the process temperature variations are presented. Monte carol analysis shows that the projected near-threshold region has minimum energy along with the moderate performance.
Źródło:
International Journal of Electronics and Telecommunications; 2019, 65, 4; 723-729
2300-1933
Pojawia się w:
International Journal of Electronics and Telecommunications
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analysis of solar cooker with thermal storage for remote hilly areas: determination of heating and cooling characteristic time
Autorzy:
Raghav, Geetanjali
Sharma, Pankaj Kumar
Kumar, Suresh
Maithani, Rajesh
Iung, Alexis
Quentin, Mercier
Powiązania:
https://bibliotekanauki.pl/articles/2142896.pdf
Data publikacji:
2021
Wydawca:
Centrum Badań i Innowacji Pro-Akademia
Tematy:
solar energy
solar cookers
thermal storage
thermal performance
energia słoneczna
kuchenka słoneczna
magazynowanie ciepła
wydajność cieplna
Opis:
Solar cooking finds a major application in rural areas of Uttarakhand, India, yet its utilization is still limited due to certain limitation such as intermittent nature of solar radiations. This drawback limits solar cooker in becoming a viable alternate solution of LPG and other pollution causing resources such as wood. In order to cater this problem a numerical analysis of box type solar cooker with storage is carried out. The energy stored in the storage material will keep the cooker warm up to the time when food is consumed. Charging and discharging time analysis is performed in with an aim to understand the effect of storage on solar cooker. Heating and cooling characteristic time are being evaluated and analysed with storage. Thermal performance of box type solar cooker is measured in terms of figures of merit according to BIS standards. The effect of storage has also been analysed in terms of charging and discharging time and first figure of merit of box type solar cooker.it has been observed that during discharging the heat is stored for more duration as compared to the charging time as discharge time is approx. 4-5 hours while charging time for the same amount of insolation is around 3-4 hours.
Źródło:
Acta Innovations; 2021, 40; 5-18
2300-5599
Pojawia się w:
Acta Innovations
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analysis of the seismic performances of structures reinforced by self-centering buckling-restrained braces
Autorzy:
Jin, Yongxu
Xu, Man
Jia, Jie
Powiązania:
https://bibliotekanauki.pl/articles/27312160.pdf
Data publikacji:
2023
Wydawca:
Polska Akademia Nauk. Czasopisma i Monografie PAN
Tematy:
budynek wysokościowy
stabilizator wyboczeniowy samocentrujący
wysięgnik
rozpraszanie energii
właściwości sejsmiczne
super-high raise building
self-centering buckling-restrained brace
outrigger truss
energy dissipation
seismic performance
Opis:
The self-centering buckling-restrained brace (SC-BRB) may achieve self-restoration for structures and, to a certain degree, diminish the substantial seismic residual deformation following rare earthquakes when compared to the usage of the conventional buckling-restrained brace (BRB). It may be possible to reduce the abrupt change in stiffness at the location of the strengthened stories and make the outrigger better at dissipating energy by improving the design of the energy-dissipation outrigger. This study compares the seismic performances of two types of energy-dissipation outriggers with BRB and SC-BRB web member designs during rare earthquakes so that the changes can be measured. The results show that using the SC-BRB web member design reduces the maximum inter-story drift ratio by an average of 7.68% and increases the average plastic-energy dissipation of the outrigger truss by 8.75%. The evaluation results showthat the SC-BRB outrigger truss structure has better structural regularity and energy-dissipation performance. It has the ability to efficiently regulate the structural seismic response and lessen primary-structure damage.
Źródło:
Archives of Civil Engineering; 2023, 69, 3; 645--663
1230-2945
Pojawia się w:
Archives of Civil Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Audyt energetyczny budynku według obowiązujących przepisów
Energy audit in accordance with the existing regulations
Autorzy:
Szmolke, N.
Powiązania:
https://bibliotekanauki.pl/articles/104827.pdf
Data publikacji:
2017
Wydawca:
Politechnika Rzeszowska im. Ignacego Łukasiewicza. Oficyna Wydawnicza
Tematy:
termomodernizacja
świadectwo charakterystyki energetycznej budynku
właściwości cieplne
przegroda budowlana
temperatura obliczeniowa
thermal renovation
energy performance certificate
thermal properties
building partitions
design temperature
Opis:
Audyt energetyczny to „opracowanie określające zakres oraz parametry techniczne i ekonomiczne przedsięwzięcia termomodernizacyjnego, ze wskazaniem rozwiązania optymalnego, w szczególności z punktu widzenia kosztów realizacji tego przedsięwzięcia oraz oszczędności energii, stanowiące jednocześnie założenia do projektu budowlanego”. W nawiązaniu do tej definicji, zaczerpniętej z Ustawy o wspieraniu termomodernizacji i remontów, w pracy omówiono szczegółową zawartość audytu energetycznego budynku, wykonanego według aktualnie obowiązujących przepisów. Wymagana zawartość audytu energetycznego oraz procedury jego wykonania znajdują się w Rozporządzeniu Ministra Infrastruktury z dnia 17 marca 2009r. w sprawie szczegółowego zakresu i form audytu energetycznego oraz części audytu remontowego, wzorów kart audytów, a także algorytmu oceny opłacalności przedsięwzięcia termomodernizacyjnego. W artykule przedstawiono etapy wykonania takiego opracowania. Szczególny nacisk położono na znaczenie poprawnie przeprowadzonej inwentaryzacji. W artykule wskazano również na zmiany w obowiązującym prawie, a szczególnie na dynamicznie zmieniające się przepisy, dotyczące izolacyjności przegród. Zwrócono uwagę na stosowanie Polskich Norm, które oficjalnie są wycofane z użycia. Dotyczy to szczególnie wartości temperatur obliczeniowych: zewnętrznej oraz wewnętrznej. W publikacji zamieszczono także kilka uwag praktycznych, pozwalających na poprawne opracowanie audytu energetycznego. Podkreślono także, że audyt energetyczny nie jest charakterystyką energetyczną budynku ani jego świadectwem charakterystyki energetycznej. Aktualnie oba te dokumenty opracowywane są zgodnie z Ustawą o charakterystyce energetycznej budynków.
Energy audit is “elaboration with a set of guidelines setting forward the scope and technical and economic parameters of a thermal upgrade, including indication of an optimum solution in particular with respect to the cost of implementing this upgrade and the resulting energy savings, also providing the basis for a building project”. In connection to this definition derived from Act on supporting thermomodernization and renovation, the present paper discusses the contents of an energy audit of a building performed in accordance with the regulations in force now. The required contents of an energy audit along with the procedures applied in its implementation are contained in The Regulation of the Minister of Infrastructure of 17 March, 2009 and relate to the scope and form of an energy audit and parts of a renovation audit, templates of audit cards, as well as an algorithm applied for the evaluation of the profitability of a thermal upgrade undertaking. The paper also contains the list of stages in such an elaboration. An emphasis was placed on the importance of an adequately performed inventory. This paper also indicates the recent changes in the legislation, in particular with regard to the dynamic changes in the laws in the area of insulation parameters of construction partitions. The common application of Polish Norms is remarked despite the fact that they are no longer officially binding. This in particular concerns the calculation of temperatures: external and internal. Besides, this paper includes a number of practical issues, whose purpose is to ensure the correct development of an energy audit. It is indicated that the energy audit is not synonymous with the characteristic of energy efficiency of a building nor with an energy performance certificate. At present, both documents are drafts under development in accordance with the Act on the energy performance of buildings.
Źródło:
Czasopismo Inżynierii Lądowej, Środowiska i Architektury; 2017, 64, 1; 441-447
2300-5130
2300-8903
Pojawia się w:
Czasopismo Inżynierii Lądowej, Środowiska i Architektury
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Audyt energetyczny, charakterystyka energetyczna oraz świadectwo charakterystyki energetycznej - co wiemy na ich temat?
Energy audit, energy performance and Energy Performance Certificate - what do we know about them?
Autorzy:
Nakielska, M.
Pawłowski, K.
Powiązania:
https://bibliotekanauki.pl/articles/371960.pdf
Data publikacji:
2017
Wydawca:
Uniwersytet Zielonogórski. Oficyna Wydawnicza
Tematy:
audyt energetyczny
charakterystyka energetyczna
świadectwo charakterystyki energetycznej
energochłonność budynku
energy audit
energy performance
Energy Performance Certificate
energy consumption of the building
Opis:
Na obecny stan prawny dotyczący modernizacji i ochrony cieplnej budynków składa się kilka rozporządzeń. Każde z nich dotyczy energochłonności budynków, jednak odwołuje się do innego dokumentu. Trzy pojęcia związane ze zużyciem energii w budynku: audyt energetyczny budynku, charakterystyka energetyczna budynku oraz świadectwo charakterystyki energetycznej budynku. Pojęcia podobne, a jakże różne pod względem treści i celu jakiemu mają służyć. W artykule oprócz podstaw prawnych poszczególnych dokumentów, zawarto wyniki ankiety mającej na celu zaprezentowanie stanu wiedzy przeciętnego obywatela z zakresu pojęć związanych z energochłonnością budynków.
The current state of law regarding the modernization and thermal protection of buildings consists of several regulations. Each of them refers to the energy intensity of buildings, but refers to another document. Three concepts related to energy consumption in a building: Energy Audit, Energy Performance of the building and Energy Performance Certificat of the building. Concepts similar, but different in terms of content and purpose to serve. In addition to the legal basis of individual documents, the article included the results of a survey aimed at presenting the average citizen's knowledge of the concepts related to energy intensity of buildings.
Źródło:
Zeszyty Naukowe. Inżynieria Środowiska / Uniwersytet Zielonogórski; 2017, 166 (46); 96-103
1895-7323
Pojawia się w:
Zeszyty Naukowe. Inżynieria Środowiska / Uniwersytet Zielonogórski
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Badania społeczne przyczynkiem do oceny jakości energetycznej budynków wielkopłytowych w osiedlach mieszkaniowych
End-user survey results as contribution to energy performance assessment of precast panel housing stock
Autorzy:
Ostańska, A.
Powiązania:
https://bibliotekanauki.pl/articles/390707.pdf
Data publikacji:
2014
Wydawca:
Politechnika Lubelska. Wydawnictwo Politechniki Lubelskiej
Tematy:
wielka płyta
badania społeczne
ocena energetyczna
partycypacja finansowa
rewitalizacja osiedli mieszkaniowych
precast panel housing
resident survey
energy performance assessment
participation
Opis:
Artykuł przedstawia wyniki badań społecznych przeprowadzonych w jednym z siedmiu osiedli w Lubelskiej Spółdzielni Mieszkaniowej. Badania, zrealizowane na podstawie autorskiego narzędzia, mają na celu rozpoznanie opinii mieszkańców na temat: dotychczasowej termomodernizacji, zakresu możliwych jeszcze działań energetycznych w samych budynkach i na terenie analizowanego osiedla, oraz pobudzenie zainteresowania wpływem na oszczędzanie energii i decyzje inwestycyjne. Badania, prowadzone cyklicznie od 2004 roku w różnych regionach kraju, stanowią część większego projektu badawczego, którego celem jest ocena potencjału możliwego oszczędzania energii i jako jeden z aspektów rewitalizacji wielkich osiedli mieszkaniowych z wielkiej płyty.
The paper presents an analysis of a survey among residents of a housing district in Lublin, Poland. The survey, conducted by means of a bespoke questionnaire, was aimed not only at collecting the end-user input on the effects of maintenance and retrofitting actions completed so far and preferences on future actions, but also to arouse interest in participating in the decision-making process related with improving energy performance of the housing stock. The investigations, being a part of a larger research project started in 2004, are focused on assessing the potential for improvement of the precast panel housing stock which is a typical feature of Poland’s building environment.
Źródło:
Budownictwo i Architektura; 2014, 13, 3; 317-324
1899-0665
Pojawia się w:
Budownictwo i Architektura
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies