Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "energy characteristics" wg kryterium: Temat


Tytuł:
A novel dry granule preparation technology and comparison of granule properties with conventional wet system for ceramic tiles production
Autorzy:
Ergin, Hasan
Taşkıran, Mehmet Uğur
Pilevne, Ahmet Atınç
Turgut, Hatice
Kayacı, Kağan
Powiązania:
https://bibliotekanauki.pl/articles/24148612.pdf
Data publikacji:
2023
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
ceramic tile
dry granulation
energy consumption
granule characteristics
Opis:
The ceramic tile manufacturing process uses a lot of energy, mainly thermal energy, and to a lesser extent electric energy. Total energy costs account for between 50% and 55% of average direct manufacturing costs. Fossil fuel combustion, such as natural gas combustion, produces carbon dioxide emissions. Therefore, energy consumption and emissions issues are vitally important for both environmental effects and process costs in ceramic tile manufacturing. The wet process of granule production systems including wet grinding and spray drying is widely used for the production of granules. Although there is high energy consumption for the water evaporation in the spray dryer, it ensures to produce high quality tile for many years. In this study, important granule properties were introduced for a novel dry granule production system. In the successful application of a dry granulation system, the conformity of produced granules is vitally important such as particle size distribution, bulk density, flow properties, and moisture of granules and conformity for the pressing process. This paper includes the comparative studies for properties of granules produced in spray dryer and new dry granule preparation systems and the full results of the industrial trials with these granules. The cost comparison of both granule production systems was also made for the same raw material usage. The natural gas consumption and water consumption were reduced respectively from 46 to 15 m3/ton and from 540 to 95 liters/ton in the new dry granulation system while electricity consumption and maintenance costs remain almost the same in both systems.
Źródło:
Physicochemical Problems of Mineral Processing; 2023, 59, 5; art. no. 167498
1643-1049
2084-4735
Pojawia się w:
Physicochemical Problems of Mineral Processing
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
A statistical approach for selecting buildings for experimental measurement of HVAC needs
Statystyczna metoda wyboru budynków badawczych na potrzeby analizy systemów HVAC
Autorzy:
Malinowski, P.
Ziembicki, P.
Powiązania:
https://bibliotekanauki.pl/articles/396766.pdf
Data publikacji:
2017
Wydawca:
Uniwersytet Zielonogórski. Oficyna Wydawnicza
Tematy:
k-means method
HVAC system performance
energy consumption
building characteristics
metoda k-średnich
systemy HVAC
zużycie energii
charakterystyka energetyczna budynków
Opis:
This article presents a statistical methodology for selecting representative buildings for experimentally evaluating the performance of HVAC systems, especially in terms of energy consumption. The proposed approach is based on the k-means method. The algorithm for this method is conceptually simple, allowing it to be easily implemented. The method can be applied to large quantities of data with unknown distributions. The method was tested using numerical experiments to determine the hourly, daily, and yearly heat values and the domestic hot water demands of residential buildings in Poland. Due to its simplicity, the proposed approach is very promising for use in engineering applications and is applicable to testing the performance of many HVAC systems.
W artykule przedstawiono statystyczną metodę wyboru budynków reprezentatywnych pod względem charakterystyki energetycznej oraz cech wbudowanych systemów grzewczych wentylacyjnych i klimatyzacyjnych. Proponowane podejście opiera się na metodzie k-średnich. Algorytm dla tej metody jest stosunkowo prosty, co pozwala na łatwe wdrożenie i nie wymaga dużego nakładu (kosztu) obliczeniowego. Sposób ten może być stosowany dla dużych ilości danych. Metodą k-średnich badano dane pozyskane w czasie inwentaryzacji obiektów oraz w wyniku symulacji komputerowych funkcjonowania budynków, zawierające m.in. roczne wartości zapotrzebowania na ciepło (symulowane z krokiem czasowym godzinnym). Z uwagi na względną prostotę metodyki oraz uzyskane bardzo dobre wyniki, proponowane podejście jest bardzo obiecujące dla zastosowań technicznych, w tym analiz budynków pod kątem systemów HVAC.
Źródło:
Civil and Environmental Engineering Reports; 2017, No. 24(1); 101-118
2080-5187
2450-8594
Pojawia się w:
Civil and Environmental Engineering Reports
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analiza porównawcza potrzeb energetycznych jednorodzinnych budynków mieszkalnych o różnym standardzie wykonania
Comparative analysis of energy demand for single-family buildings with different standard of realization
Autorzy:
Siuta-Olcha, A.
Cholewa, T.
Guz, Ł.
Powiązania:
https://bibliotekanauki.pl/articles/126789.pdf
Data publikacji:
2011
Wydawca:
Towarzystwo Chemii i Inżynierii Ekologicznej
Tematy:
budynek niskoenergetyczny
budynek pasywny
charakterystyka energetyczna budynku
low-energy building
passive building
building energy characteristics
Opis:
Ograniczenie zużycia energii oraz wykorzystanie energii ze źródeł odnawialnych w sektorze budynków mieszkalnych jest działaniem priorytetowym w krajach członkowskich Unii Europejskiej. Działania te pozwalają na efektywne i zrównoważone wykorzystanie potencjału paliw kopalnych oraz na zmniejszenie emisji zanieczyszczeń gazowych i pyłowych, powstających w procesie energetycznego spalania paliwa. Stale rosnące ceny nośników energii również wymuszają konieczność poprawy charakterystyki energetycznej danego budynku, w szczególności budynku nowo wznoszonego. Celem pracy jest porównanie potrzeb energetycznych budynku mieszkalnego jednorodzinnego o określonej kubaturze i powierzchni ogrzewalnej, który (a) spełnia aktualne wymagania ochrony cieplnej, (b) jest budynkiem niskoenergetycznym, (c) spełnia standardy budynku pasywnego. Energochłonność budynku nie tylko zależy od izolacyjności cieplnej przegród budowlanych, ale również od sprawności systemów technicznych budynku. Dlatego też w obliczeniach wprowadzono kilka wariantów systemów grzewczych, w tym wspomaganych energią ze źródeł odnawialnych. Do obliczeń wskaźnika zapotrzebowania na energię pierwotną oraz zapotrzebowania na energię końcową budynków wykorzystano pakiet do projektowania budynków pasywnych (PHPP). Dla rozważanych przypadków oszacowano całkowite koszty dostarczanej energii do budynku, to jest koszt ogrzewania, przygotowania ciepłej wody użytkowej oraz koszt energii elektrycznej.
The limitation of energy consumption and the renewable energy utilization in residential sector is a preference activity in the member countries of the European Union. These activities let on the effective and balanced utilization of the fossil fuels potential and on the diminution of gaseous and dust emission, which are associated with the process of the fuel combustion. Constantly growing prices of energy carriers force also the necessity of improvement of the building energy-characteristics, particularly in the new buildings. An aim of this work is the comparison of energy needs of the one-family building (with determined cubature and heating area), which (a) fulfils current requirements of the thermal protection, (b) is a low-energy building, (c) fulfils standards of the passive building. Energy consumption of the building depends not only on the thermal insulation of building partitions, but also on the efficiency of building technical systems. That is why in calculations, there are introduced several variants of heating systems, also this supported by renewable energy sources. To calculations of the primary power requirement indicator and final power requirements of buildings the software (PHPP) to the designing of passive buildings, was used. For considered cases total costs of the delivered energy to the building, particularly the heating, hot water preparation and the electrical energy costs, were estimated.
Źródło:
Proceedings of ECOpole; 2011, 5, 1; 287-292
1898-617X
2084-4557
Pojawia się w:
Proceedings of ECOpole
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analysis of the properties and impact of the shape of a flexible photovoltaic roof tile on the effectiveness of its performance
Autorzy:
Dobrzycki, A.
Kurz, D.
Laska, D.
Powiązania:
https://bibliotekanauki.pl/articles/97279.pdf
Data publikacji:
2016
Wydawca:
Politechnika Poznańska. Wydawnictwo Politechniki Poznańskiej
Tematy:
photovoltaic roof tile
BIPV
amorphous cells
energy yield
current–voltage characteristics
photovoltaic module exposure
Opis:
This paper concerns building integrated photovoltaics (BIPV), and in particular, potential advantages resulting from the use of this technology. The possibilities of integration of the BIPV elements in the building structure were presented, with particular consideration of photovoltaic roof covering. In order to demonstrate the legitimacy of using solutions of this type in real conditions, the subject of the analysis was the thin–film photovoltaic module, which constitutes an integral part of the photovoltaic roof tile. During the tests, particular attention was paid to changes in parameters of the tested object, depending on the way it is shaped in relation to the solar radiation, demonstrating in this way, the necessity to strive for the optimal exposure of the BIPV elements in relation to the sun.
Źródło:
Computer Applications in Electrical Engineering; 2016, 14; 432-443
1508-4248
Pojawia się w:
Computer Applications in Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Aproksymacja nieliniowych charakterystyk maszyn elektrycznych prądu przemiennego wielomianami potęgowymi wielu zmiennych
Approximation of Nonlinear Characteristics of AC Machines by Multivariable Power Polynomials
Autorzy:
Sobczyk, T. J.
Warzecha, A.
Mazgaj, W.
Powiązania:
https://bibliotekanauki.pl/articles/1368195.pdf
Data publikacji:
2013
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Napędów i Maszyn Elektrycznych Komel
Tematy:
maszyny elektryczne
nieliniowość magnetyczna
nieliniowe charakterystyki uzwojeń
aproksymacja funkcji ko-energii magnetycznej
electrical machines
magnetic nonlinearity
nonlinear winding characteristics
approximation of magnetic co-energy function
Opis:
To model non-linearity of magnetic circuit of alternating current machines at circuit approach it is necessary to know, so called, characteristic of windings determining leakage fluxes as of each winding as a function of currents of all machine windings. Such functions can be approximated by multivariable Power series of currents. However, it leads to rather complicated relationships between a set of such functions. The paper presents a methodology for computation of the coefficients of those multivariable power series bases on values of the co-energy and the winding leakage fluxes, or eventually dynamic inductances, using the linear regression method. Combining those values reduces time and costs of numerical computations necessary for its calculations.
W celu uwzględnienia nieliniowości obwodu magnetycznego maszyny elektrycznej w modelach obwodowych należy wyznaczyć tzw. charakterystyki uzwojeń maszyny określające strumienie skojarzone każdego z uzwojeń jako funkcje prądów wszystkich uzwojeń. Ich aproksymacja jest - w zasadzie - możliwa tylko za pomocą wielomianów potęgowych wielu zmiennych. Prowadzi to do bardzo złożonych relacji między funkcjami aproksymującymi. W pracy zaproponowano modyfikację metodyki określania współczynników występujących w tych wielomianach na podstawie zbioru wartości ko-energii magnetycznej oraz strumieni skojarzonych lub dodatkowo indukcyjności dynamicznych przy wykorzystaniu metody regresji liniowej. Jednoczesne wykorzystanie wartości ko-energii magnetycznej oraz strumieni skojarzonych ma na celu ograniczenie czasu i kosztów obliczeń numerycznych potrzebnych dla ich obliczania.
Źródło:
Maszyny Elektryczne: zeszyty problemowe; 2013, 3, 100/1; 101-105
0239-3646
2084-5618
Pojawia się w:
Maszyny Elektryczne: zeszyty problemowe
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Badania właściwości metrologicznych termoanemometrycznej metody pomiaru energii gazu ziemnego
Study of metrological properties of thermo-anemometric method of natural gas energy measurement
Autorzy:
Serediuk, O.
Malisevych, V.
Warsza, Z. L.
Powiązania:
https://bibliotekanauki.pl/articles/275836.pdf
Data publikacji:
2017
Wydawca:
Sieć Badawcza Łukasiewicz - Przemysłowy Instytut Automatyki i Pomiarów
Tematy:
gaz ziemny
wartość energetyczna
ciepło spalania
pomiar energii gazu
przetwornik termoanemometryczny
charakterystyka kalibracyjna
niepewność pomiarów
natural gas
energy value
combustion heat
gas energy measurement
thermo-anemometer
calibration characteristics
measurement uncertainty
Opis:
Przedstawiono termoanemometryczną metodę bezpośredniego pomiaru wartości energetycznej przepływającego gazu ziemnego. Jest ona oparta na zastosowaniu dwu przetworników: termoanemometrycznego i różnicy ciśnień. Opisano konstrukcję i działanie laboratoryjnego stanowiska przeznaczonego do badania tej metody. Na podstawie wyników badań doświadczalnych wyznaczono charakterystykę kalibracyjną przetwornika termoanemometrycznego i zależność jego sygnału wyjściowego od zmian wartości energetycznej gazu naturalnego dla zakresu wartości opałowej (7759–8538) kcal/m3 i przepływów do 0,6 m3/h. Przeprowadzono analizę składowych niepewności pomiarów typu B tą metodą i oszacowano jej niepewność standardową. Jest to przykład metody pośredniej, która polega na pomiarze innego parametru gazu, zależnego od zmian jego składu, gdy parametr właściwy jest trudny do określenia, lub nie można go zbadać bezpośrednio. Taka metoda może znaleźć wiele innych zastosowań.
The thermo-anemometric method of direct measurement of the energy value of the flowing natural gas is presented. It is based on two transducers: thermo-anemometric (hot-wire) and differential pressure. The design and operation of the laboratory stand for testing this method has been described. Based on the experimental results, the calibration characteristics of the thermoanemometric transducer and the dependence of its output on the calorific value of the natural gas for the range of (7759–8538) kcal/m3 and flows to 0.6 m3/h were determined. An analysis of uncertainty components of B-type measurements was carried out using this method and its standard uncertainty was assessed. This is an example of an indirect method for examining changes of the tested parameter dependent on the composition of the gas if its direct measurements are difficult or impossible to perform. Instead, another parameter is measured, which depends in a known manner on the composition of the gas as a mixture. Such method can find many other different applications.
Źródło:
Pomiary Automatyka Robotyka; 2017, 21, 4; 49-57
1427-9126
Pojawia się w:
Pomiary Automatyka Robotyka
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Combustion characteristics for small diesel engine by using emulsified blend fuels of vegetable oil and light oil
Autorzy:
Kawakami, T.
Powiązania:
https://bibliotekanauki.pl/articles/247229.pdf
Data publikacji:
2011
Wydawca:
Instytut Techniczny Wojsk Lotniczych
Tematy:
combustion characteristics
small diesel engine
ecology energy
Opis:
The paper is focusing on combustion characteristics for small diesel engine by using emulsified blend fuels of vegetable oil and light oil. Target is to achieve low emissions and low fuel consumption for internal combustion engines. The fuels used in this study are light oil, blend fuels [light oil + coconut oil, light oil + palm oil], and emulsified fuels [light oil + water, blend fuels + water]. Mean increasing rate of pressure is calculated from the value which subtracted initial pressure from maximum burning pressure divided by total burning time. The mean increasing ratio of pressure is calculated from the value which subtracted initial pressure from maximum burning pressure divided by the total burning time. The emissions in exhaust gas are measured with an analyzer of exhaust gas. The data of 30 tests for each engine revolutions were averaged arithmetically. Experimental approach and results have been presented by details. The main conclusions are as follows: it is possible to control the combustion behaviour by using blend fuels and emulsified blend fuels for small diesel engine; the maximum burning pressure of emulsified blend fuels increases at low engine speed; the CO emission of blend fuels is smaller than that of light oil; the NOX emission of emulsified coconut blend fuel and emulsified palm blend fuel is smaller than that of light oil; the CO emission of emulsified Coconut-Palm blend fuel is equal to that of light oil at low engine speed.
Źródło:
Journal of KONES; 2011, 18, 4; 185-190
1231-4005
2354-0133
Pojawia się w:
Journal of KONES
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Comparison of single-diode models applied to thin film PV module operating under different environmental conditions
Autorzy:
Gulkowski, S.
Powiązania:
https://bibliotekanauki.pl/articles/1940695.pdf
Data publikacji:
2017
Wydawca:
Politechnika Gdańska
Tematy:
solar energy
photovoltaics
I-V electrical characteristics
computational modeling
Opis:
The electrical current-voltage (I-V) characteristic a of photovoltaic (PV) module depends on the environmental conditions under which it operates. The shape of the I-V curve depends on the solar cell technology and changes dynamically in time with irradiance and temperature. A simulation model of the PV module can be used to examine the dynamic behavior of the I-V curve as well as to extract the module parameters from the curves. This paper presents the results of comparison of two different models based on a single-diode equivalent circuit applied to a thin film module. The Matlab/Simulink simulation studies of I-V characteristic curves in the function of irradiance and temperature were carried out. The results were compared with the experimental data of the I-V curves obtained from outdoor measurements. Relative errors of the simulation and experimental results were analyzed.
Źródło:
TASK Quarterly. Scientific Bulletin of Academic Computer Centre in Gdansk; 2017, 21, 1; 43-52
1428-6394
Pojawia się w:
TASK Quarterly. Scientific Bulletin of Academic Computer Centre in Gdansk
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Design concepts of gaseous detonation guns for thermal spraying
Principy konstruirovanija detonacionno-gazovykh ustanovok dlja napylenija pokrytijj
Autorzy:
Kharlamov, Y.
Kharlamov, M.
Powiązania:
https://bibliotekanauki.pl/articles/792142.pdf
Data publikacji:
2013
Wydawca:
Komisja Motoryzacji i Energetyki Rolnictwa
Tematy:
gaseous detonation
structural analysis
coating deposition
thermal spraying
conventional coating techniqu
energy source
oscillatory system
dynamic characteristics
Źródło:
Teka Komisji Motoryzacji i Energetyki Rolnictwa; 2013, 13, 4
1641-7739
Pojawia się w:
Teka Komisji Motoryzacji i Energetyki Rolnictwa
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Dobór systemu zasilania w energię budynku mieszkalnego termomodernizowanego do standardu nZEB
Energy source selection for a residential building modernized for meeting the nZEB standard requirements
Autorzy:
Trząski, A.
Rucińska, J.
Wiszniewski, A.
Powiązania:
https://bibliotekanauki.pl/articles/362657.pdf
Data publikacji:
2018
Wydawca:
Instytut Fizyki Budowli Katarzyna i Piotr Klemm
Tematy:
charakterystyka energetyczna
alternatywne źródła energii
nZEB
budynek niemal zeroenergetyczny
energy characteristics
alternate energy source
nearly zero-energy building
Opis:
W artykule przedstawiono wyniki analizy dotyczącej wyboru systemu zasilania w energię Domu Studenckiego „Muszelka”, przygotowywanego do standardu nZEB. Ze względu na objęcie obiektu ochroną konserwatorską, przy opracowywaniu koncepcji jego termomodernizacji do standardu nZEB napotkano na szereg ograniczeń, zarówno w zakresie poprawy ochrony cieplnej, jak i wykorzystania alternatywnych źródeł energii. Ostatecznie na postawie przeprowadzonych analiz zaproponowano zastosowanie jedynie dwóch rozwiązań: paneli fotowoltaicznych oraz pompy ciepła wykorzystującej ciepło z powietrza usuwanego z pomieszczeń do wstępnego podgrzewu wody użytkowej. Przeprowadzona analiza wykazała, że pomimo wykorzystywania przez budynek, bardzo korzystnego źródła ciepła (ciepło sieciowe o wi=0,68), osiągnięcie standardu nZEB, jedynie za pomocą rozwiązań konwencjonalnych może nie być możliwe a efektywne wykorzystanie alternatywnych źródeł energii wymaga odpowiedniego sposobu bilansowania produkcji i zużycia energii.
The paper presents results of an analysis of the energy source selection for the “Muszelka” Student House, prepared for the nZEB standard. As the building is located in an area under the supervision of the conservator the nZEB adaptation has been subjected to a number of constraints, both in terms of improving thermal protection and the use of alternative energy sources. Finally, on the basis of the analyzes, only two solutions were proposed: photovoltaic panels and heat pumps utilizing heat from the air removed ventilation air to preheat the domestic water. The analysis showed that, despite the use of a very favorable heat source by the building (net heat of wi = 0.68), the achievement of the nZEB standard by conventional means may not be possible and the efficient use of alternative energy sources requires appropriate balancing of production and energy consumption.
Źródło:
Fizyka Budowli w Teorii i Praktyce; 2018, T. 10, nr 1, 1; 41-44
1734-4891
Pojawia się w:
Fizyka Budowli w Teorii i Praktyce
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Dynamic characteristics of magnetic coupling in horizontal axis wave energy device
Autorzy:
Zhang, J.
Liu, Y.
Liu, J.
He, T.
Xie, Y.
Powiązania:
https://bibliotekanauki.pl/articles/258488.pdf
Data publikacji:
2017
Wydawca:
Politechnika Gdańska. Wydział Inżynierii Mechanicznej i Okrętownictwa
Tematy:
wave energy
magnetic coupling
dynamic characteristics
transfer function
step response
steady state error
Opis:
To solve the dynamic response problems of magnetic coupling in the horizontal axis wave energy device, this has researched the dynamic characteristicsof magnetic coupling. The fitting formula about torque and angle of the magnetic coupling is obtained through experiments. The mathematical models of the magnetic coupling torque transmission are established. The steady state error of the magnetic coupling and the transfer function of the output angle are obtained. The analytical solution of the step response of the output angle in time domain is derived. The influence of the torsional rigidity, the damping coefficient and the driven rotor’s rotational inertia on dynamic characteristics of the magnetic coupling isanalyzed. According to the analysis results, the design rules of magnetic coupling are proposed.
Źródło:
Polish Maritime Research; 2017, S 3; 165-170
1233-2585
Pojawia się w:
Polish Maritime Research
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Dynamic interactions stability analysis of hybrid renewable energy system with SSSC
Autorzy:
He, Ping
Qi, Pan
Ji, Yuqi
Li, Zhao
Powiązania:
https://bibliotekanauki.pl/articles/1841302.pdf
Data publikacji:
2021
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
damping characteristics
dynamic interaction analysis
eigenvalue analysis
hybrid renewable energy system
SSSC
charakterystyka tłumienia
dynamiczna analiza interakcji
analiza wartości własnej
hybrydowy system energii odnawialnej
Opis:
The static series synchronous compensator (SSSC) has demonstrated its capability in providing voltage support and improving power system stability. The objective of this paper is to analyze the dynamic interaction stability mechanism of a hybrid renewable energy system connected with doubly-fed induction generators (DFIGs) and solid oxide fuel cell (SOFC) energy with the SSSC. For this purpose, a linearized mathematical model of this modified hybrid single-machine infinite-bus (SMIB) power system is developed to analyze the physical mechanism of the SSSC in suppressing oscillations and the influence on the dynamic stability characteristics of synchronization. Typical impacting factors such as the series compensation level, the SOFC penetration and tie-line power are considered in the SMIB and two-area systems. The impact of dynamic interactions on enhancing damping characteristics and improving transient performance of the studied systems is demonstrated using eigenvalue analysis and dynamic time-domain simulations, which validates the validity of the proposed physical mechanism simultaneously.
Źródło:
Archives of Electrical Engineering; 2021, 70, 2; 445-462
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Effect of Ohmic Heating on the Rheological Characteristics and Electrical Conductivity of Mulberry (Morus nigra) Puree
Autorzy:
Hardinasinta, Gemala
Salengke, Salengke
Mursalim, Mursalim
Muhidong, Junaedi
Powiązania:
https://bibliotekanauki.pl/articles/1417183.pdf
Data publikacji:
2021-08-20
Wydawca:
Instytut Rozrodu Zwierząt i Badań Żywności Polskiej Akademii Nauk w Olsztynie
Tematy:
ohmic heating
mulberry puree
rheological characteristics
pseudo activation energy
electrical conductivity
Opis:
The effect of temperatures (30–90°C) and concentrations (50% and 100%) on rheological parameters of mulberry puree processed with ohmic heating (OH) were evaluated. The electrical conductivities of mulberry puree ranged from 0.022 to 0.102 S/m for 50% puree and 0.052 to 0.185 S/m for 100% puree. The best model for rheological parameters of mulberry puree was the power law model (R²>0.90). The effects of OH treatment and temperature of puree on the flow behavior index (n) were insignificant (p≥0.05). However, a significant difference (p<0.05) between consistency coefficient (K) of OH-treated and control sample was observed in 100% puree. The pseudo activation energy (Ea) of ohmic-treated puree was 9.67 kJ/mol for 50% puree and 3.69 kJ/mol for 100% puree, both of these values were significantly lower than that of the unprocessed 100% puree (16.07 kJ/mol). The obtained Ea indicates that after undergoing ohmic heating pretreatment, consistency coefficient of mulberry puree became less sensitive to temperature.
Źródło:
Polish Journal of Food and Nutrition Sciences; 2021, 71, 3; 289-297
1230-0322
2083-6007
Pojawia się w:
Polish Journal of Food and Nutrition Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Effect of the maximum magnetic energy on dynamic parameters of the electric drive
Wpływ maksymalnej energii magnetycznej na dynamiczne parametry napędu elektrycznego
Autorzy:
Volokitina, Y.
Goloviznin, S.
Shalaginov, V.
Powiązania:
https://bibliotekanauki.pl/articles/159932.pdf
Data publikacji:
2006
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Elektrotechniki
Tematy:
silnik elektryczny bezszczotkowy
charakterystyka dynamiczna
energia magnetyczna
brushless electric motors
improving dynamic characteristics
maximum magnetic energy
Opis:
In the paper there are questions of increase of the angular velocity of the airship rudder surfaces for the sinusoidal control input signal under conservation of the electric drive dynamic parameters by using the permanent magnets with higher maximum magnetic energy.
Artykuł omawia problemy wzrostu prędkości kątowej powierzchni sterów statków powietrznych dla sinusoidalnego wejściowego sygnału sterowania przy zachowaniu dynamicznych parametrów elektrycznego napędu przy użyciu magnesów trwałych o wyższej energii maksymalnej.
Źródło:
Prace Instytutu Elektrotechniki; 2006, 229; 97-105
0032-6216
Pojawia się w:
Prace Instytutu Elektrotechniki
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Encapsulation of l-menthol in hydroxypropyl-β-cyclodextrin and release characteristics of the inclusion complex
Autorzy:
Zhu, G.
Xiao, Z.
Zhou, R.
Niu, Y.
Powiązania:
https://bibliotekanauki.pl/articles/778623.pdf
Data publikacji:
2016
Wydawca:
Zachodniopomorski Uniwersytet Technologiczny w Szczecinie. Wydawnictwo Uczelniane ZUT w Szczecinie
Tematy:
l-menthol
inclusion complex
release characteristics
binding energy
release kinetics
Opis:
l-menthol has been widely used in flavour, food and pharmaceuticals. Because of its high volatility and whisker growth, l-menthol-hydroxypropyl-β-cyclodextrin inclusion complex was produced to improve shelf-life, provide protection, and enhance the stability of l-menthol. The inclusion complex was characterized by Fourier transform infrared spectroscopy, X-ray diffraction. The results show that l-menthol was successfully encapsulated in hydroxypropyl-β-cyclodextrin. l-menthol loading capacity is about 8.44%. Geometries and binding energies of l-menthol-hydroxypropyl-β-cyclodextrin inclusion complexes were investigated using molecular mechanics calculations. The shape and orientation of the most stable complex, and the minimum binding energy were determined. L-menthol release from complex was determined by thermogravimetric analysis. Two l-menthol release rate peaks were observed at 69.3 and 279.1°C. The l-menthol release reaction order, release activation energy and the preexponential factor were obtained.
Źródło:
Polish Journal of Chemical Technology; 2016, 18, 3; 110-116
1509-8117
1899-4741
Pojawia się w:
Polish Journal of Chemical Technology
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies