Tytuł:
A device for testing of the tribological properties of interverebral disc endoprosthesis - SBT-03.1 simulator
Autorzy:
Mróz, A.
Wiśniewski, T.
Gierzyńska-Dolna, M.
Magda, J.
Powiązania:
https://bibliotekanauki.pl/articles/285417.pdf
Data publikacji:
2012
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie. Polskie Towarzystwo Biominerałów
Tematy:
intervertebral disc endoprosthesis of the spine
friction and wear tests
SBT-03.1 simulator
friction coefficient
Opis:
As a result of research conducted in the Metal Forming Institute in Poznan, SBT-03 simulator for friction and wear testing of human intervertebral disc endoprostheses was modernized. The structure of the device allows reflecting of the range of mobility and loads present in the natural spine. Moreover, the device allows recording and measurement of such parameters as axial compression force, moment of friction, temperature in the friction loop and number of operation cycles. This enables an evaluation of the intensity of wear processes of different designs of structures of a lumbar spine intervertebral disc endoprostheses depending on the type of materials used and production method.
Źródło:
Engineering of Biomaterials; 2012, 15, no. 116-117 spec. iss.; 5-6
1429-7248
Pojawia się w:
Engineering of Biomaterials
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
An assessment of the return to professional activity of patients aged ≤30 years after hip replacement surgery
Autorzy:
Drobniewski, Marek
Synder, Marek
Krasińska, Magdalena
Sibiński, Marcin
Borowski, Andrzej
Powiązania:
https://bibliotekanauki.pl/articles/2093867.pdf
Data publikacji:
2021-12-13
Wydawca:
Instytut Medycyny Pracy im. prof. dra Jerzego Nofera w Łodzi
Tematy:
return to work
arthroplasty
total hip replacement
hip arthritis
clinical and radiological outcome
endoprosthesis
Opis:
ObjectivesThe study evaluated the professional activity of patients after a total cementless hip replacement surgery performed at the age of ≤30 years.Material and MethodsThe study group comprised 87 patients, with 95 total cementless hip replacements. The mean age was 25.7 years. The youngest patient was 17 years old, and the oldest 30 years old. The mean length of observation was 20.1 years, ranging 5–33 years. All patients underwent clinical and radiological evaluations before the surgery, and again in the third, sixth and twelfth months after the surgery. Further follow-up visits were performed every year. The tests were scored according to the Merle d’Aubigné and Postel (MAP) classification, as recommended by the Polish Society of Orthopaedics and Traumatology. Postoperative radiographs were used to assess the position of the endoprosthesis, and the degree of implant healing in the bone tissue. The data was subjected to statistical analysis.ResultsOf the surveyed group, 67 patients were professionally active before the surgery: 34 were white-collar workers, 29 manual workers, and 4 students or school pupils. The remaining 20 had not worked for many years, and were receiving sickness or disability benefits. An excellent result, according to the Kellgren-Lawrence classification, was noted in 22 cases, a good result in 42 cases, and a satisfactory result in 6 cases. In 25 cases, a poor result was observed. All of the patients professionally active before the surgery returned to work following the procedure. A further analysis found that 15 previously-unemployed patients commenced employment following the procedure. The mean length of the sick leave was 196.2 days, and rehabilitation payments were granted in 5 cases.ConclusionsTotal cementless hip replacement is a valuable method of treating osteoarthritis in young patients. All of the patients who worked before the surgery returned to work in the same position and on the same employment conditions. Most of the previously-unemployed patients commenced employment following the procedure.
Źródło:
International Journal of Occupational Medicine and Environmental Health; 2021, 34, 6; 747-754
1232-1087
1896-494X
Pojawia się w:
International Journal of Occupational Medicine and Environmental Health
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analiza materiałoznawcza deimplantowanego elementu endoprotezy stawu biodrowego
Material analysis of the deimplanted element of hip joint endoprosthesis
Autorzy:
Płatek, Marta
Dudek, Agata
Ucieklak, Jarosław
Powiązania:
https://bibliotekanauki.pl/articles/285276.pdf
Data publikacji:
2019
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie. Polskie Towarzystwo Biominerałów
Tematy:
endoprotezoplastyka stawu biodrowego
trzpień endoprotezy
rewizja
stop Co-Cr-Mo
hip joint endoprosthesis
stem of endoprosthesis
revision
Co-Cr-Mo alloy
Opis:
Pomimo postępu jaki dokonał się w ostatnich latach w zakresie endoprotezoplastyk stawu biodrowego jednym z nierozwiązanych do końca zagadnień pozostaje problem aseptycznych i septycznych obluzowań elementów endoprotez. Dlatego stale trwają poszukiwania rozwiązań pozwalających zminimalizować ryzyko zapaleń okołoprotezowych i aseptycznych obluzowań endoprotez. Przedmiotem badania był trzpień endoprotezy Mittelmeiera usunięty z powodu aseptycznego obluzowania po 16 latach od wszczepienia. Przeprowadzano analizę strukturalną wykorzystując mikroskop świetlny i skaningowy oraz zbadano skład chemiczny materiału, z którego wykonano implant. Dokonano również oceny stopnia degradacji jego powierzchni. Analiza składu chemicznego porównana do pierwotnego składu tego trzpienia ujawniła, iż bezpośredni kontakt implantu z płynami ustrojowymi i żywą tkanką wpływa na zmianę ilościową poszczególnych pierwiastków. Mikroskopia skaningowa elektronowa ujawniła na metalowym trzpieniu liczne wżery, pęknięcia oraz ubytki powstałe na skutek zużycia oraz korozji. Wykonane badania wykazały, że nie tylko implant osadzony w kości oddziałuje na okoliczne tkanki, ale zachodzą zmiany również w obrębie wszczepionego implantu. Bezpośrednią przyczyną obluzowania implantu była osteoliza związana z nagromadzeniem w przestrzeni pomiędzy implantem a kością elementów zużycia korozyjnego i erozyjnego. Na podstawie zebranych danych z Oddziału Chirurgii Urazowo-Ortopedycznej Szpitala Czerniakowskiego Sp. z o.o. w Warszawie wykonano ponadto analizę statystyczną przeprowadzonych endoprotezoplastyk pierwotnych i rewizyjnych oraz występujących powikłań, ze szczególnym uwzględnieniem obluzowań elementów endoprotez, które wymagały operacji rewizyjnych.
Despite the progress that has been made in recent years in the field of hip joint endoprostheses, the problem of aseptic and septic loosening of endoprosthetic elements remains one of the unresolved issues. Therefore, the research on solutions to minimize the risk of periprosthetic inflammations and aseptic loosening of endoprostheses is still ongoing. The subject of the study was a stem of the Mittelmeier’s endoprosthesis removed due to its aseptic loosening after 16 years of implantation. The structural analysis was carried out using a light and scanning microscope and the chemical composition of the implant material was examined. The analysis of the chemical composition compared to the original composition of the stem revealed that direct contact of the implant with body fluids and living tissue affects the quantitative change of individual elements. Scanning electron microscopy revealed numerous pitting, cracks and losses caused by wear and corrosion on the metal stem. The research carried out showed that not only does the implant inserted in the bone affect the surrounding tissue, but there are also changes within the implanted prosthesis. The direct cause of the implant loosening was osteolysis in the space between the implant and the bone, associated with the accumulation of elements of corrosion and erosion wear. Based on the collected results from the Trauma and Orthopaedic Surgery Department of the Czerniakowski Hospital in Warsaw, a statistical analysis of primary and revision endoprostheses and complications was performed, with particular emphasis on the loosening of the endoprostheses elements that required revision surgeries.
Źródło:
Engineering of Biomaterials; 2019, 22, 150; 2-9
1429-7248
Pojawia się w:
Engineering of Biomaterials
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analiza procesów tribologicznych występujących w skojarzeniu panewka–główka endoprotezy stawu biodrowego
The analysis of the tribological processes occurring in the socket-and-ball friction pair of a hip joint endoprosthesis
Autorzy:
Niemczewska-Wójcik, M.
Piekoszewski, W.
Powiązania:
https://bibliotekanauki.pl/articles/190930.pdf
Data publikacji:
2015
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
staw biodrowy
endoproteza
topografia powierzchni
zużywanie
hip joint
endoprosthesis
surface topography
wear
Opis:
W pracy przedstawiono staw biodrowy jako idealne biołożysko. Omówiono przyczyny uszkodzenia naturalnego stawu biodrowego człowieka oraz sposoby przywrócenia utraconych funkcji, w tym alloplastykę stawów. W części badawczo- -analitycznej pracy omówiono przyczyny obniżenia trwałości endoprotez stawu biodrowego w oparciu obadania własne in vitro. Przedmiotem badań było skojarzenie panewka–główka endoprotezy stawu biodrowego. Powierzchnie badanych elementów zostały przygotowane zgodnie z wytycznymi norm. Badania tribologiczne przeprowadzono w otoczeniu płynu Ringera. Badania stanu powierzchni przed i po eksploatacji przeprowadzono na trzech urządzeniach: współrzędnościowej maszynie pomiarowej, mikroskopie interferometrycznym oraz skaningowym mikroskopie elektronowym. Wyniki przeanalizowano pod kątem procesów tribologicznych (mechanizmów zużycia) występujących w skojarzeniu polimerowa panewka–metalowa główka endoprotezy stawu biodrowego.
The paper presents a hip joint as an ideal system. The causes of the damage to a natural human hip joint and the ways of restoring its lost functions along with hip joint alloplasty are discussed. In the research part of this paper, based on in vitro study, the reasons for the loss of artificial hip joint durability are described. The subject of the research was the socket-andball friction pair, making the elements of a hip joint endoprosthesis. The surfaces of the analysed samples were prepared in accordance with the guidelines of the standards. The tribological tests were conducted in the environment of Ringer's solution. The examination of the surface topography before and after tribological tests was carried out with three units: a coordinate measurement machine, white light interferometry, and a scanning electron microscope. The results were analysed in terms of tribological processes (wear mechanisms) occurring in the friction pair consisting of the polymer socket and the metal head of a hip joint endoprosthesis.
Źródło:
Tribologia; 2015, 6; 81-92
0208-7774
Pojawia się w:
Tribologia
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analiza stanu biomechanicznego w stawie biodrowym po całkowitej alloplastyce z różnymi wariantami endoprotez bezcementowych
The analysis of biomechanical state in a hip joint after complete alloplastics with different variant of cementless endoprosthesis
Autorzy:
Ryniewicz, A.M.
Madej, T.
Powiązania:
https://bibliotekanauki.pl/articles/189404.pdf
Data publikacji:
2010
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
staw biodrowy
endoprotezy bezcementowe
analiza
naprężenia
przemieszczenia
hip joint
cementless endoprosthesis
analysis
stresses
translations
Opis:
W opracowaniu wykonano modelowanie i symulacje rozkładów naprężeń i przemieszczeń w aplikacjach z bezcementowymi endoprotezami stawu biodrowego. Analizie poddano biołożyska z panewkami o strukturze warstwowej wykonane z polietylenu wysokocząsteczkowego oraz korundu i polietylenu wysokocząsteczkowego, z zewnętrznymi obejmami z tytanu. We wszystkich endoprotezach głowy były korundowe, a trzpienie tytanowe. Endoprotezy osadzano wirtualnie, w odwzorowanych na podstawie tomografii komputerowej strukturach kostnych. Dla zamodelowanych geometrycznie obiektów badań dokonano analizy wytrzymałościowej z wykorzystaniem metody elementów skończonych. Wyniki badań pozwoliły porównać rozwiązania konstrukcyjne endoprotez oraz ocenić charakter oddziaływania sztucznego stawu na otaczające tkanki kostne w warunkach indywidualnego pacjenta.
Modelling and simulation of the stress distribution and displacements in the applications with cementless endoprosthesis of a hip joint were carried out. The analysis subjected biobearings with cups of layered structures made from high molecular polyethylene, corundum, and high molecular polyethylene with external connection clips from titanium. The heads in all endoprosthesis were from corundum and the stems from titanium. The endoprosthesis were seated virtually in natural bone struc- tures that had been obtained from computer tomography. The stress analysis for the geometrically modelled objects of research was made using the finite element method. The results of the analysis allowed us to estimate the stress and displacements distribution in endoprosthesis and the character of the interaction of the artificial joint on the surrounding bone tissue in the conditions of an individual patient.
Źródło:
Tribologia; 2010, 2; 137-152
0208-7774
Pojawia się w:
Tribologia
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analiza wytrzymałościowa endoprotezy stawu kolanowego
Strength analysis of total knee prosthesis
Autorzy:
Tejszerska, D
Długoszewski, T.
Gąsiorek, D
Powiązania:
https://bibliotekanauki.pl/articles/99077.pdf
Data publikacji:
2010
Wydawca:
Politechnika Śląska. Katedra Biomechatroniki
Tematy:
analiza wytrzymałościowa
endoproteza
staw kolanowy
ANSYS
strength analysis
endoprosthesis
knee joint
Opis:
W artykule przedstawiono analizę wytrzymałościową endoprotezy stawu kolanowego z wyłączeniem elementu udowego dla kilku wariantów obciążenia. Analiza ta pozwala na obserwację wpływu obciążenia na stan naprężeń i odkształceń w kości i endoprotezie. Model i jego analizę przeprowadzono metodą elementów skończonych w programie Ansys Workbench.
Numerical strength analysis of total knee prosthesis without femur element for few variants of load was presented in this paper. This analysis allow us observe the influence of load on the state of stress and strain in tibia bone and prosthesis . The model and its finite element analysis was performed in ANSYS Workbench.
Źródło:
Aktualne Problemy Biomechaniki; 2010, 4; 213-218
1898-763X
Pojawia się w:
Aktualne Problemy Biomechaniki
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analysis of selected roughness parameters describing the degree of surface wear of Weller endoprostheses heads
Analiza wybranych parametrów chropowatości opisujących stopień zużycia powierzchni głów endoprotez Wellera
Autorzy:
Cwanek, J.
Czajkowski, A. A.
Powiązania:
https://bibliotekanauki.pl/articles/135910.pdf
Data publikacji:
2017
Wydawca:
Wyższa Szkoła Techniczno-Ekonomiczna w Szczecinie
Tematy:
orthopaedics
Weller endoprosthesis
heads exploitation
parameters St
parameters Sz
parameters Sa
parameters Sds
ortopedia
endoprotezy Wellera
eksploatacja głów
parametry St
parametry Sz
parametry Sa
parametry Sds
Opis:
Introduction and aims: The results of analysis for surface geometry of Weller endoprosthesis heads removed from the aseptic loosening of artificial hip joint are presented in the paper. A dependence between the values of amplitude parameters and time period of endoprosthesis exploitation are shown in this paper. Moreover the dependence between the various amplitude parameters of analysed heads surface is described in the paper. Material and methods: It was tested the surface of 37 heads of Weller endoprosthesis, which were exploited from 5 to 20 years. Measurements of geometrical structure were realized by using the Rank Taylor Hobson Talyscan 150 apparatus. The scanning region of Weller endoprosthesis heads had the range of 1,5-2,0 mm2 scanning velocity about 5,0 mm/s. Obtained data were saved and analysed by the Talymap 3.0 computing program. Results: The effect of exploitation of Weller endoprosthesis heads refers to decreasing the values of analysed parameters St, Sz, Sa and Sds. That fact means not only the worse work conditions in the wear point “polyethylene cup - head” of Weller endoprosthesis but also early occurring of aseptic loosening in implanted artificial joint. Conclusions: The dependence between the parameters Sds and St, and also between the parameters Sds and Sz showed rather little correlation with decreasing trend [p<0,05]. The relations between the parameters values Sz and St describing the heads surface of Weller endoprosthesis and time period of their exploitation showed some significant decreasing dependence [p<0,001]. From comparison of parameters St, Sz and Sds implies that each pair of analysed parameters has negative directly proportional relation.
Wstęp i cele: W pracy przedstawiono wyniki analizy geometrii powierzchni głów endoprotez Wellera usuniętych z powodu aseptycznego obluzowania sztucznego stawu biodrowego. W pracy przedstawiono zależność między wartościami parametrów amplitudy i czasem eksploatacji endoprotezy. Ponadto opisano zależności między różnymi parametrami amplitudy powierzchni analizowanych głów. Materiał i metody: Testowano powierzchnię 37 głów endoprotez Wellera, które były eksploatowane od 5 do 20 lat. Pomiary struktury geometrycznej zrealizowano za pomocą aparatu Rank Taylor Hobson Talyscan 150. Obszar skanowania głów endoprotez Weller miał zakres 1,5-2,0 mm2 z prędkością skanowania około 5,0 mm/s. Uzyskane dane zostały zapisane i przeanalizowane przez program obliczeniowy Talymap 3.0. Wyniki: Wpływ eksploatacji głów endoprotez Wellera odnosi się do obniżenia wartości analizowanych parametrów St, Sz, Sa i Sds. Fakt ten oznacza nie tylko gorsze warunki pracy w punkcie zużycia „polietylenowa panewka - głowa” endoprotezy Wellera, ale także wczesne pojawienie się aseptycznego obluzowania w wszczepionym sztucznym stawie. Wnioski: Zależność między parametrami Sds i St, a także między parametrami Sds i Sz wykazywała raczej niewielką korelację z tendencją malejącą [p<0,05]. Zależność między wartościami parametrów Sz i St opisującymi powierzchnię główek endoprotezy Wellera a okresem ich eksploatacji wykazała istotną zależność malejącą [p<0,001]. Z porównania parametrów St, Sz i Sds wynika, że każda para analizowanych parametrów ma ujemną wprost proporcjonalną zależność.
Źródło:
Problemy Nauk Stosowanych; 2017, 7; 157-168
2300-6110
Pojawia się w:
Problemy Nauk Stosowanych
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analysis of Stresses and Strains Distribution of Polyethylene Cups in Hip Joint Endoprosthesis at Various Articular Joints and Friction Conditions
Autorzy:
Mordal, Katarzyna
Szarek, Arkadiusz
Powiązania:
https://bibliotekanauki.pl/articles/2049722.pdf
Data publikacji:
2021
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
polyethylene
UHMWPE
hip joint endoprosthesis
friction conditions
computer modelling
Opis:
The article has been devoted to issues connected with the alloplasty and hip joint endoprostheses, that elements are being developed, which is supported by strength, tribological tests on used biomaterials, incl. polyethylene or computer modelling based on e.g. finite element method (FEM). In this paper, the results of research on the impact of the material articulations of the system head – acetabular and friction conditions on strength parameters of polyethylene components in the hip joint endoprosthesis. Numerical analysis of this friction node was carried out, using the ADINA System computer program and the simulations were performed at various friction conditions for metal/ polyethylene and ceramic/ polyethylene articulations with various UHMWPE modifications. The simulations results have shown the influence of tested material associations and friction conditions on parameters related to the strength of polyethylene cups, i.e. their displacements, stresses and deformations.
Źródło:
Archives of Metallurgy and Materials; 2021, 66, 2; 523-530
1733-3490
Pojawia się w:
Archives of Metallurgy and Materials
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analysis of the loads occurring in a modular hip joint endoprosthesis
Autorzy:
Sobociński, M.
Powiązania:
https://bibliotekanauki.pl/articles/122656.pdf
Data publikacji:
2016
Wydawca:
Politechnika Częstochowska. Wydawnictwo Politechniki Częstochowskiej
Tematy:
endoprosthesis
FEM
finite elements method
contact stress
endoproteza
naprężenia kontaktowe
analiza obciążenia
Opis:
This paper contains the results of the load analysis of a modular hip joint endoprosthesis, performed by means of the finite elements method, using Autodesk Simulation Mechanical 2016 software. A geometric model was created based on real solutions using Autodesk Inventor Professional. The obtained results make it possible to indicate the “weak points” of the accepted solution, and thus counteract the subsequent effects resulting from premature wear of endoprosthesis elements.
Źródło:
Journal of Applied Mathematics and Computational Mechanics; 2016, 15, 3; 135-142
2299-9965
Pojawia się w:
Journal of Applied Mathematics and Computational Mechanics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analysis of wear of polyethylene hip joint cup related to its positioning in patient’s body
Autorzy:
Rońda, J.
Wojnarowski, P.
Powiązania:
https://bibliotekanauki.pl/articles/307555.pdf
Data publikacji:
2013
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
hip joint endoprosthesis
wear
coefficient of wear
finite element method
proteza stawu biodrowego
metoda elementów skończonych
zużycie
Opis:
Polyethylene parts of endoprosthesis are the weakest parts of each medical implant. They can be worn out within several years. During this period, a patient can enjoy good physical efficiency until the wear of polyethylene part limits his/her mobility. Then the reoperation is necessary and positioning of all parts of endoprosthesis has an effect on future patient’s mobility and durability of implant. Elements of endoprosthesis during exploitation are heavily loaded both by normal and tangential forces and moments. In this paper, the dependence of wear of polyethylene cup on its positioning in pelvis is the major problem. Wear of the cup is determined by two measures: the depth and volume of a material rubbed off from the contact surface. The sensitivity of the depth of rubbing off is evaluated relative to two angles of anteversion and abduction, and radii of the cup. Numerical results are obtained by using Abaqus FE system with data related to patient’s activity identified on the basis of medical reports.
Źródło:
Acta of Bioengineering and Biomechanics; 2013, 15, 1; 77-86
1509-409X
2450-6303
Pojawia się w:
Acta of Bioengineering and Biomechanics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Assessment of the effects of Proprioceptive Neuromuscular Facilitation therapy on the improvement of motor function in a patient after total hip replacement – a case study
Autorzy:
Guzik, Agnieszka
(, Anna Szpitman
Drużbicki, Mariusz
Wyszyńska, Justyna
Wolan-Nieroda, Andżelina
Powiązania:
https://bibliotekanauki.pl/articles/454875.pdf
Data publikacji:
2017
Wydawca:
Uniwersytet Rzeszowski. Wydawnictwo Uniwersytetu Rzeszowskiego
Tematy:
hip joint
osteoarthritis
endoprosthesis plasty
PNF method
total hip arthroplasty
Opis:
Hip osteoarthritis is a serious clinical and social problem. The number of patients who suffer from degenerative changes in the hip joints and require endoprosthesis-plasty is constantly increasing. This paper presents physiotherapeutic activities based on Proprioceptive Neuromuscular Facilitation (PNF) which optimize a patient’s mobilization using the reserves in their body fully to make improvements in movement and to regain lost functions for achieving beneficial therapeutic effects. The aim of the study was to evaluate the influence of PNF therapy on changes in muscle strength, mobility, and gait pattern in patients after Total Hip Arthroplasty. The case described here regards a 63-year-old woman diagnosed with left hip osteoarthritis who had Total Hip Arthroplasty. The patient was examined twice before and after PNF therapy. The range of mobility of hip joints, level of pain, muscular strength and gait were assessed. Applied PNF therapy, including dynamic (eccentric, concentric) and static muscle training, post-isometric relaxation, stabilization and control in the stance phase, resulted in improved hip joint mobility, muscle strength, gait pattern and pain reduction in the patient. The case study demonstrates that a short (two-week) but intensive (over two hours per day) PNF therapy positively influenced selected motor functions after Total Hip Arthroplasty.
Źródło:
European Journal of Clinical and Experimental Medicine; 2017, 3; 287-294
2544-2406
2544-1361
Pojawia się w:
European Journal of Clinical and Experimental Medicine
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Badania struktury geometrycznej powierzchni ceramicznych elementów trących endoprotezy stawu biodrowego
The surface geometrical structure research of ceramic friction elements of hip joint endoprosthesis
Autorzy:
Niemczewska-Wójcik, M.
Powiązania:
https://bibliotekanauki.pl/articles/189253.pdf
Data publikacji:
2009
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
endoproteza
technologia wytwarzania
struktura geometryczna powierzchni
funkcjonalność
endoprosthesis
manufacturing process
surface geometrical structure
functionality
Opis:
W referacie przedstawiono zasady kształtowania struktury geometrycznej powierzchni elementów endoprotez (głów) wykonanych z mono- i polikrystalicznych materiałów ceramicznych. Przytoczono wymagania odnoszące się do biomateriałów, elementów endoprotezy stawu biodrowego oraz przeprowadzania badań struktury geometrycznej ich powierzchni (błąd kształtu i chropowatość). Uzyskane wyniki pomiarów błędów kształtu (odchyłki okrągłości) oraz chropowatości poddano analizie, na podstawie której wysunięto wnioski dotyczące kształtowania głów endoprotez stawu biodrowego.
The paper presents the rules of forming the surface geometrical structure for endoprosthesis elements (femoral head) made of mono and polycrystalline ceramic materials. The requirements for biomaterials and elements of hip joint endoprosthesis were described. The surface geometrical structure research (shape deviations and roughness) was discussed. The results of shape deviations (departure from roundness) and surface roughness measurements were analysed. On the basis of the analysis, conclusions on the manufacturing process of the head of hip joint endoprosthesis were drawn.
Źródło:
Tribologia; 2009, 2; 107-118
0208-7774
Pojawia się w:
Tribologia
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Badania tribologiczne i biotribologiczne w Laboratorium Inżynierii Powierzchni i Tribologii Sieci Badawczej Łukasiewicz – Instytutu Obróbki Plastycznej
Tribological and biotribological research in the Laboratory of Surface Engineering and Tribology of Łukasiewicz Research Network – Metal Forming Institute
Autorzy:
Wiśniewski, Tomasz
Sulej-Chojnacka, Joanna
Leshchynsky, Volf
Lijewski, Marcin
Łapaj, Łukasz
Powiązania:
https://bibliotekanauki.pl/articles/212004.pdf
Data publikacji:
2019
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Obróbki Plastycznej
Tematy:
tribologia
tarcie
narzędzia kuźnicze
endoproteza
tester tribologiczny
tribology
friction
forging tools
endoprosthesis
tribological tester
Opis:
W niniejszej pracy przedstawiono wyniki badań, które są efektem realizowanych w Sieci Badawczej Łukasiewicz – Instytucie Obróbki Plastycznej zarówno projektów krajowych, jak i międzynarodowych, dotyczących tematyki tribologicznej oraz biotribologicznej. Przedstawiono wyniki badań, których efektem jest opracowanie nowej generacji narzędzi kuźniczych (zaprojektowanie narzędzi do kucia na zimno z odpowiednio przygotowaną powierzchnią roboczą i opracowanie nowych wielowarstwowych, nanostrukturalnych powłok gradientowych) oraz rozwiązanie problemu wczesnego zużywania się części pracujących w trudnych warunkach eksploatacyjnych. Dla elementów trących pracujących w wysokiej temperaturze opracowano rozwiązanie, które znalazło praktyczne zastosowanie w przemyśle w zakresie poprawy technologii smarowania. Opracowanie technologii wprowadzenia cząstek smarów stałych na powierzchnie współpracujących tribologicznie części pracujących w podwyższonych temperaturach stało się niezwykle istotne dla wielu gałęzi przemysłu, które spotykają się na co dzień z problemami wczesnego zużywania elementów współpracujących. W drugiej części pracy skupiono się na problemach biotribologicznych, gdzie głównym wyzwaniem jest wydłużenie trwałości endoprotez stawu biodrowego. W związku z tym prowadzono prace związane z dokładnym poznaniem procesu zużywania się endoprotez. Bardzo ważną kwestię stanowi również badanie właściwości tribologicznych nowych materiałów przeznaczonych na elementy endoprotez. Badania prowadzono na specjalnie do tego celu zaprojektowanym i zbudowanym symulatorze stawu biodrowego, który spełnia wymogi normy ISO.
This paper presents the results of research, which are the effect of national and international projects carried out at the Łukasiewicz Research Network – Metal Forming Institute, concerning both tribological and biotribological topics. The research results, the effect of which is the development of a new generation of forging tools (the design of cold forging tools with a properly prepared work surface and the development of new multilayered, nanostructured gradient coatings) and the solution to the problem of early wear of the parts working in difficult conditions are presented. For friction elements operating at high temperature, a solution has been developed that has found practical applications in the industry in the field of improving lubrication technology. The development of the technology of introducing solid lubricant particles onto the surfaces of tribologically cooperating parts operating at elevated temperatures has become extremely important for many industries that daily face problems with the early wear of cooperating elements. The second part of the work focuses on biotribological problems and the main challenge is to extend the durability of hip joint endoprostheses. In connection with this, work was carried out to thoroughly understand the process of endoprosthesis wear. Examination of the tribological properties of new materials intended for elements of endoprostheses is also a very important issue. The research was conducted on a specially designed and built hip joint simulator, which meets the requirements of the ISO standard.
Źródło:
Obróbka Plastyczna Metali; 2019, 30, 3; 247-272
0867-2628
Pojawia się w:
Obróbka Plastyczna Metali
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Badania wpływu czasu na właściwości mechaniczne polietylenowych panewek endoprotez stawu biodrowego
Examination of times influence on mechanical properties of polyethylene hip cup endoprostheses
Autorzy:
Kolczyk, E.
Sobczyk, K.
Myalski, J.
Balin, A.
Powiązania:
https://bibliotekanauki.pl/articles/284860.pdf
Data publikacji:
2008
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie. Polskie Towarzystwo Biominerałów
Tematy:
endoproteza
panewka
właściwości mechaniczne
twardość
wytrzymałość na rozciąganie
moduł sprężystości
endoprosthesis
cup
mechanical properties
hardness
tensile strength
elasticity modulus
Opis:
W pracy badano wpływ czasu na właściwości polietylenowych panewek endoprotez stawu biodrowego. Badaniom poddano oryginalne panewki z wysokocząsteczkowego polietylenu, wyprodukowane w latach od 1991 do 2003. Przeprowadzono pomiar twardości oraz statyczną próbę rozciągania próbek wykonanych z panewek. Stwierdzono niekorzystny wpływ czasu na właściwości mechaniczne panewek polietylenowych. Wraz z upływem czasu wystąpił wzrost twardości i modułu sprężystości E oraz spadek wytrzymałości na rozciąganie Rm polietylenu, z którego wykonane były panewki. Zmiany właściwości mechanicznych polietylenowych panewek mogą prowadzić do kruchego pękania materiału.
The paper refers to the study of the influence of time on the properties of polyethylene hip joint cups. Original cups made of a high-molecular-weight polyethylene, produced in the years 1991-2003, were used for the study. Hardness measurement and a static tensile test of cup specimens were carried out. A disadvantageous impact of time upon the polyethylene cups' mechanical properties was observed. Over time, an increase in hardness and elasticity modulus E was observed coupled with a decrease in tensile strength Rm of the polyethylene of which the cups were made. Changes in the polyethylene cups' mechanical properties may lead to material's brittle cracking.
Źródło:
Engineering of Biomaterials; 2008, 11, 74; 11-15
1429-7248
Pojawia się w:
Engineering of Biomaterials
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Badanie własności fizykochemicznych bezcementowych panewek stawu biodrowego
Electrochemical study of uncemented hip endoprosthesis cups
Autorzy:
Kajzer, W.
Kajzer, A.
Grzeszczuk, O.
Semenowicz, J.
Mroczka, A.
Powiązania:
https://bibliotekanauki.pl/articles/284760.pdf
Data publikacji:
2015
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie. Polskie Towarzystwo Biominerałów
Tematy:
stal Cr-Ni-Mo
panewka stawu biodrowego
odporność korozyjna
stainless steel
hip endoprosthesis
corrosion resistance
Opis:
Celem prowadzonych badań było porównanie własności panewki nowej oraz po alloplastyce rewizyjnej przebywającej w organizmie człowieka przez 68 miesięcy. W ramach badań przeprowadzono analizę składu chemicznego, własności mechanicznych oraz fizykochemicznych. Własności te analizowano na podstawie badań z wykorzystaniem optycznej spektrometrii emisyjnej ze wzbudzeniem jarzeniowym, pomiarów twardości oraz badań potencjodynamicznych odporności na korozję wżerową i elektrochemicznej spektroskopii impedancyjnej EIS. Badanie elektrochemiczne przeprowadzono w roztworze Ringera. Dodatkowo przeprowadzono analizę makroskopową powierzchni. Na podstawie przeprowadzonych badań stwierdzono, że badane panewki zostały wytworzone ze stali Cr-Ni-Mo spełniającej zalecenia normy ISO 5832-9. Wyniki pomiarów twardości ujawniły obszary o zróżnicowanym umocnieniu biomateriału panewki. Uzyskane parametry odporności korozyjnej dla panewki po implantacji były porównywalne do wartości uzyskanych dla panewki w stanie wyjściowym. Dodatkowo przeprowadzone badania EIS określiły charakter warstwy tlenkowej występującej na powierzchni implantu po usunięciu z organizmu. Wykazały one występowanie warstwy podwójnej stanowiące dobre zabezpieczenie biomateriału metalowego przed rozwojem niekorzystnych zjawisk korozyjnych. Natomiast przeprowadzone obserwacje makroskopowe ujawniły występowanie warstwy hydroksyapatytu na powierzchni panewki po 68-miesięcznym przebywaniu w organizmie. Podsumowując można stwierdzić, że przyczyną alloplastyki rewizyjnej był brak osteointegracji powierzchni zewnętrznej implantu spowodowany nierównomiernym przyleganiem implantu do powierzchni kości. Nie zaobserwowano jednak zmniejszenia odporności korozyjnej panewki po implantacji, co wskazuje na jej biokompatybilność w środowisku tkankowym.
The aim of the research was to compare the properties of the new cup and the cup after alloplastic revision surgery which has been staying in the human body for 68 months. In the studies chemical composition, mechanical and physicochemical properties were analyzed. The properties were analyzed on the basis of studies of glow discharge atomic emission, measurements of hardness and potentiodynamic studies of resistance to pitting corrosion and electrochemical impedance spectroscopy (EIS). The electrochemical research was conducted in Ringer’s solution. Additionally, analysis of the macroscopic surface was conducted. The results revealed that the cups were produced from high nitrogen stainless steel which chemical composition and mechanical properties met the requirements of the ISO 5832-9 standards. The results of hardness revealed areas with varied strengthening of the cup’s biomaterial. Parameters of the corrosion resistance for the cup after implantation were comparable to the values obtained for the cup in the initial state. Additionally, EIS study determined the nature of the oxide layer on the surface of the implant removed from the body. The results showed the existence of a double layer forming good protection of the metal biomaterial against corrosion. The performed macroscopic observation revealed the presence of hydroxyapatite on the surface of the cup after the 68 months in the body. We conclude that the reason for revision arthroplasty was the lack of osteointegration of the outer surface of the implant caused by non- -uniform adhesion of the implant to the bone surface. However, no reduction in corrosion resistance of the cup after implantation was observed which indicates its biocompatibility in the tissue environment.
Źródło:
Engineering of Biomaterials; 2015, 18, 132; 9-16
1429-7248
Pojawia się w:
Engineering of Biomaterials
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies