Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "elemental composition" wg kryterium: Temat


Tytuł:
PM10, PM25 and PM10 Indoor and Outdoor Concentrations and Chemical Composition in School Environment
Stężenia oraz skład chemiczny pyłu PM10, PM25 oraz PM10 w powietrzu wewnętrznym i zewnętrznym szkoły
Autorzy:
Zwoździak, A.
Sówka, I.
Skrzętowicz, M.
Worobiec, A.
Nych, A.
Zwoździak, J.
Grieken, R.
Powiązania:
https://bibliotekanauki.pl/articles/389676.pdf
Data publikacji:
2011
Wydawca:
Towarzystwo Chemii i Inżynierii Ekologicznej
Tematy:
PM1.0
PM2.5
PM10
powietrze wewnętrzne i zewnętrzne
skład elementarny
PM10 indoor-outdoor particles
elemental composition
Opis:
Simultaneous daily indoor and outdoor measurements of PM1.0, PM2.5, PM10 have been conducted during winter season of 2009/2010 in the secondary school in Wroclaw, Poland. Aerosol samples were analysed for mass concentrations and elemental composition. The factor analysis was applied to identify possible emission sources of the PM1.0 fraction. Mean daily PM10 concentrations was 81 g/m3 indoors and 54 g/m3 outdoors. The corresponding means for PM2.5 and PM1.0 were 62 and 22 g/m3 indoors and 46 and 24 g/m3 outdoors. There were reported 90 % of days with daily mean exceeding the WHO AQG for PM2.5 – 25 g/m3. In many cases the I/O ratio was higher than 1.0, what means that there are some particles sources inside the school building, particularly for the fractions PM10 and PM2.5. The most abundant elements in the PM1.0 fraction were S, Cl and K. Zn and Pb were the dominant heavy metals. Combustion processes contributed to high concentrations of K, S, As, Cl and vehicular emission to Cu, Pb and Zn.
Jednoczesne pomiary stężeń pyłu PM1.0, PM2.5, PM10 w powietrzu wewnętrznym i zewnętrznym zostały przeprowadzone w szkole średniej we Wrocławiu w sezonie zimowym 2009/2010 roku. Pobrane próbki aerozolu analizowano pod względem wysokości stężenia masowego oraz składu pierwiastkowego. Analizę czynnikową wykorzystano do oceny źródeł pochodzenia cząstek frakcji PM1.0. W powietrzu wewnętrznym średnie dobowe stężenie PM10 wynosiło 81 g/m3, a zewnętrznym 54 g/m3. Odpowiednie średnie dla PM2.5 i PM1.0 wynosiły 62 i 22 g/m3 wewnątrz i 46 i 24 g/m3 na zewnątrz budynku. Na podstawie przeprowadzonych pomiarów odnotowano 90 % dni ze średnim dobowym stężeniem frakcji PM2.5 powyżej wartości zalecanej w wytycznych Światowej Organizacji Zdrowia, tj. 25 g/m3. W wielu przypadkach stosunek stężeń w powietrzu wewnętrznym (I) do stężeń w powietrzu zewnętrznym (O), tj. I/O, był większy od 1.0, co oznaczało istnienie źródeł pyłów wewnątrz budynku, a dotyczyło do przede wszystkim frakcji PM10 i PM2.5. We frakcji PM1.0 w największych koncentracjach pojawiały się S, Cl i K, a wśród metali ciężkich Zn i Pb. Procesy spalania miały największy udział w stężeniach K, S, As i Cl, natomiast motoryzacja w przypadku stężeń Cu, Pb i Zn.
Źródło:
Ecological Chemistry and Engineering. A; 2011, 18, 7; 933-940
1898-6188
2084-4530
Pojawia się w:
Ecological Chemistry and Engineering. A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Molecular composition of humic substances isolated from permafrost peat soils of the eastern European Arctic
Autorzy:
Vasilevich, Roman
Lodygin, Evgeny
Abakumov, Evgeny
Powiązania:
https://bibliotekanauki.pl/articles/2041913.pdf
Data publikacji:
2018
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
Arctic
forest-tundra
Histosols
humic and fulvic acids
13C NMR
elemental and amino acid composition
Źródło:
Polish Polar Research; 2018, 39, 4; 481-503
0138-0338
2081-8262
Pojawia się w:
Polish Polar Research
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The elemental composition of biomass ashes as a preliminary assessment of the recovery potential
Charakterystyka pierwiastkowych składów chemicznych popiołów ze spalania biomasy jako wstępna ocena kierunku odzysku
Autorzy:
Uliasz-Bocheńczyk, A.
Mokrzycki, E.
Powiązania:
https://bibliotekanauki.pl/articles/216753.pdf
Data publikacji:
2018
Wydawca:
Polska Akademia Nauk. Instytut Gospodarki Surowcami Mineralnymi i Energią PAN
Tematy:
popiół lotny
spalanie biomasy
skład pierwiastkowy
odzysk odpadów
recovery
elemental composition
biomass ash
fly ash
Opis:
The use of biomass in the energy industry is the consequence of ongoing efforts to replace Energy from fossil fuels with energy from renewable sources. However, due to the diversity of the biomass, its use as a solid fuel generates waste with diverse and unstable chemical composition. Waste from biomass combustion is a raw material with a very diverse composition, even in the case of using only one type of biomass. The content of individual elements in fly ash from the combustion of biomass ranges from zero to tens of percent. This makes it difficult to determine the optimal recovery methods. The ashes from the combustion of biomass are most commonly used in the production of building materials and agriculture. This article presents the elemental composition of the most commonly used biomass fuels. The results of the analysis of elemental composition of fly ashes from the combustion of forest and agricultural biomass in fluidized bed boilers used in the commercial power industry were presented. These ashes are characterized by a high content of calcium (12.3–19.4%), silicon (1.2–8.3%), potassium (0.05–1.46%), chlorine (1.1–6.1%), and iron (0.8–6.5%). The discussed ashes contained no sodium. Aluminum was found only in one of the five ashes. Manganese, chromium, copper, nickel, lead, zinc, sulfur, bismuth, titanium and zirconium were found in all of the examined ashes. The analysis of elemental composition may allow for a preliminary assessment of the recovery potential of a given ash.
Stosowanie biomasy w energetyce jest działaniem w ramach zastępowania paliw kopalnych pozyskiwaniem energii ze źródeł odnawialnych. Jednak jej stosowanie jako paliwa stałego ze względu na różnorodność stosowanej biomasy powoduje powstawanie odpadów o bardzo zróżnicowanym i niestabilnym składzie chemicznym. Odpady ze spalania biomasy są surowcem o bardzo zróżnicowanym składzie nawet w przypadku spalania biomasy jednego rodzaju. Zawartość poszczególnych pierwiastków w popiołach lotnych ze spalania biomasy waha się od zera do kilkudziesięciu procent. To zróżnicowanie powoduje, że trudno znaleźć dla nich metody odzysku. Najczęściej rozpatrywane kierunki stosowania popiołów ze spalania biomasy to produkcja materiałów budowlanych i rolnictwo. W artykule przedstawiono wyniki badań pierwiastkowych składów chemicznych z podziałem na najczęściej stosowane paliwa z biomasy. Zaprezentowane zostały wyniki dotyczące pierwiastkowych składów chemicznych popiołów lotnych ze spalania biomasy leśnej i rolniczej w kotłach fluidalnych w energetyce zawodowej. Popioły te charakteryzują się wysoką zawartością: wapnia (12,3–19,4%), krzemu (1,2–8,3%), potasu (0,05–1,46%), chloru (1,1–6,1%), żelaza (0,8–6,5%). Nie stwierdzono w nich obecności sodu. Tylko w jednym z 5 popiołów stwierdzono obecność glinu. We wszystkich badanych popiołach stwierdzono obecność: manganu, chromu, miedzi, niklu, ołowiu, cynku, siarki, bizmutu, cyrkonu, tytanu. Analiza pierwiastkowych składów chemicznych może pozwolić na wstępne określenie kierunku odzysku dla danego popiołu.
Źródło:
Gospodarka Surowcami Mineralnymi; 2018, 34, 4; 115-132
0860-0953
Pojawia się w:
Gospodarka Surowcami Mineralnymi
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Średni ciężar atomowy chondrytów LL5: Siena, Hautes Fagnes i NWA 7915
Mean atomic weight of LL5 chondrites: Siena, Hautes Fagnes and NWA 7915
Autorzy:
Szurgot, Marian
Powiązania:
https://bibliotekanauki.pl/articles/1033066.pdf
Data publikacji:
2016
Wydawca:
Polskie Towarzystwo Meteorytowe
Tematy:
Hautes Fagnes
NWA 7915 chondrite
Siena chondrite
chondrites
elemental composition
grain density
mean atomic number
mean atomic weight
Opis:
Mean atomic weights Amean of Siena (LL5, fall 1794), Hautes Fagnes (LL5, S1, W1, find 1965) and NWA 7915 (LL5, S2, W3, find 2010) ordinary chondrites have been determined using literature data on chemical composition of the meteorites and using relationship between mean atomic weight and Fe/Si atomic ratio (Szurgot 2015). It was shown that NWA 7915 Amean = 22.80 is close to mean atomic weight of LL chondrites (Amean = 23.00), and is close to mean atomic weight of LL chondrite falls (Amean = 22.90, Szurgot 2015). NWA 7915’s Fe/Si atomic ratio (0.529) leads to Amean = 23.28 which is close to the value determined by bulk composition. This means that NWA 7915 belongs to LL5 chondrites, as previously classified (Brawata et al. 2014). Mean atomic weight Amean of Hautes Fagnes determined by bulk composition is between 23.11 and 23.35. Lower Amean value is close to Amean of LL chondrites, but higher value is the same as Amean of intermediate L/LL chondrites (23.34 for L/LL, Szurgot 2016). Hautes Fagnes Fe/Si atomic ratio and Amean(Fe/Si) are identical with those for NWA 7915 (Fe/Si = 0.529, Amean = 23.28). Amean data indicate that Hautes Fagnes can belong to LL5 chondrites, as previously classified (Vandeginste et al. 2012) or can be one of L/LL chondrites. Mean atomic weight of Siena meteorite is much higher than expected for LL chondrite. Siena’s bulk composition gives Amean = 24.47, and Amean(Fe/Si) dependence gives Amean = 24.45 (Fe/Si = 0.7345). Using dependence between mean atomic weight and grain density (Szurgot 2015) leads to Amean = 23.24 (dgr = 3.46 g/cm3, Macke 2010), and using dependence between Amean and magnetic susceptibility (Szurgot 2016) gives Amean = 23.53±0.13 (logc = 4.65±0.09, Macke 2010). Bulk composition and Fe/Si ratio indicate that Siena has the same Amean as intermediate H/L chondrites, for which Amean = 24.3 (Szurgot 2016). Grain density indicates rather L/LL intermediate group for Siena, and magnetic susceptibility indicates intermediate L/LL or L chondrites (23.34 for L/LL, and 23.67 for L, Szurgot 2016). Mean atomic number Zmean, and Amean/Zmean ratio of the three meteorites have been also determined. Siena’s Zmean = 12.104, Hautes Fagnes Zmean = 11.445–11.562, and NWA 7915’s Zmean = 11.293. Amean/Zmean ratios are: 2.022 for Siena, 2.019–2.020 for Hautes Fagnes, and 2.019 for NWA 7915.
Źródło:
Acta Societatis Metheoriticae Polonorum; 2016, 7; 133-143
2080-5497
Pojawia się w:
Acta Societatis Metheoriticae Polonorum
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Średni ciężar atomowy chondrytu Sołtmany, chondrytów L6 i minerałów pozaziemskich
Mean atomic weight of Sołtmany chondrite, L6 chondrites and extraterrestrial minerals
Autorzy:
Szurgot, Marian
Powiązania:
https://bibliotekanauki.pl/articles/1033038.pdf
Data publikacji:
2015
Wydawca:
Polskie Towarzystwo Meteorytowe
Tematy:
Girgenti chondrite
Holbrook chondrite
Jesenice chondrite
Leedey chondrite
Modoc chondrite
Sołtmany chondrite
chondrites
elemental composition
grain density
mean atomic weight
Opis:
Mean atomic weight Amean of Sołtmany (L6, S2, W0) ordinary chondrite, various L6 chondrites such as: Jesenice, Girgenti, Leedey, Bruderheim, Holbrook and Modoc, as well as LL, L and H chondrites has been determined using literature data on chemical composition of the meteorites. Relationship between mean atomic weight and Fe/Si atomic ratio for ordinary chondrites has been established. It was shown that Sołtmany’s Amean = 23.97 is close to mean atomic weight of L chondrites Amean = 23.70, and is close to mean atomic weight of L6 chondrites Amean = 24.06±0.16. It has been established that Sołtmany’s Fe/Si atomic ratio (Fe/Si = 0.588) is close to Fe/Si ratio for L6 chondrites (Fe/Si = 0.598). This means that Sołtmany belongs to L6 chondrites, as previously classified. Using discovered by the author (Szurgot, 2015) dependence between mean atomic weight and uncompressed density of planetary matter it was established that grain density of Sołtmany meteorite should be equal to 3.56±0.12 g/cm3, which is about 4% lower than previously estimated by porosity data. Mean atomic weight of extraterrestrial minerals present in ordinary chondrites and in Sołtmany meteorite have been also determined.
Źródło:
Acta Societatis Metheoriticae Polonorum; 2015, 6; 107-128
2080-5497
Pojawia się w:
Acta Societatis Metheoriticae Polonorum
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Stężenie oraz skład elementarny cząstek pyłu zawieszonego w powietrzu wewnętrznym wybranej szkoły i w atmosferze Wrocławia
Indoor and outdoor air particulate matter concentrations and chemical composition in naturally yentilated school enyironment and Wroclaws atmosphere
Autorzy:
Sówka, I.
Zwoździak, A.
Skrętowicz, M.
Worobiec, A.
Nych, A.
Grieken, R.
Zwoździak, J.
Powiązania:
https://bibliotekanauki.pl/articles/125717.pdf
Data publikacji:
2011
Wydawca:
Towarzystwo Chemii i Inżynierii Ekologicznej
Tematy:
PM1.0
PM2.5
PM10
powietrze wewnętrzne
powietrze zewnętrzne
skład elementarny cząstek pyłu w powietrzu
PM10 indoor-outdoor particles
elemental composition
Opis:
Pomiary stężeń pyłu PM1.0, PM2.5, PM10 zostały przeprowadzone w okresie zimowym 2009 i 2010 roku w szkole średniej oraz na obszarach miejskich we Wrocławiu. Pobrane w powietrzu wewnętrznym oraz zewnętrznym próbki aerozolu analizowano pod względem poziomu stężenia oraz składu pierwiastkowego. W powietrzu wewnętrznym stężenia PM 1.0, PM2.5 i PM10 wyniosły kolejno: 13-36, 18+143 oraz 21-190 ug/m3. Pomiary wykazały, że w powietrzu zewnętrznym stężenia pyłu zawieszonego były mniejsze i mieściły się w granicach: 15-41 (PM1.0), 24-79 (PM2.5) oraz 26-95 Hg/m3 (PM10). Jakość powietrza we Wrocławiu oceniono zgodnie w wytycznymi Jakości Powietrza Światowej Organizacji Zdrowia (WHO AQO). Na podstawie przeprowadzonych obliczeń odnotowano 90% dni ze średnią dobową powyżej wartości stężeń określonych w ww. wytycznych: w przypadku frakcji PM2.5 - 25 ug/m3. Zmierzone we Wrocławiu stężenia PM2.5 w zakresie 24-79 ug/m3 mogą zatem wskazywać na wzrost ryzyka zachorowalności związanej z zanieczyszczeniem powietrza pyłem zawieszonym.
The measurements of PM1.0, PM2.5, PMIO have been conducted during the winter season of 2009 and 2010 in the secondary school and over urban area in Wrocław, Poland. Both, indoor and outdoor aerosol samples were analyzed for their weight and elemental composition. Indoor PM1.0, PM2.5 and PMIO concentrations ranged 13-36, 18-143 and 21-190 Hg/m3, respectively. The results showed that outdoor particulate matter concentrations were lower than indoor one and ranged 15-41 (PM1.0), 24-79 (PM2.5), and 26-95 ug/m3 (PMIO). Air quality in Wrocław has been categorized according to World Health Organization Air Quality Guideline (WHO AQG). There were reported 90% of days with daily mean exceeding the WHO AQG for PM2.5 - 25 ug/m3. Within the measured concentration range 24-79 ug/m3 a significant daily increase in morbidity risk has been deduced.
Źródło:
Proceedings of ECOpole; 2011, 5, 2; 617-622
1898-617X
2084-4557
Pojawia się w:
Proceedings of ECOpole
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Kalibracja wyników analiz chemicznych piaskowców czerwonego spągowca wykonanych przenośnym spektrometrem XRF
Calibration of the results of Rotliegend sandstones chemical analyses performed with a handheld XRF spectrometer
Autorzy:
Skupio, Rafał
Zagórska, Urszula
Kowalska, Sylwia
Powiązania:
https://bibliotekanauki.pl/articles/1834126.pdf
Data publikacji:
2020
Wydawca:
Instytut Nafty i Gazu - Państwowy Instytut Badawczy
Tematy:
fluorescencja rentgenowska
spektrometria XRF
kalibracja
skład pierwiastkowy
analiza skał
X-ray fluorescence
XRF spectrometry
calibration
elemental composition
rock analysis
Opis:
Handheld X-ray fluorescence spectrometers with energy dispersion (EDXRF) are increasingly used to determine the chemical composition of rocks for the oil and gas industry. The results of our research allow to create or support the lithological interpretation based on mineralogical models. In the case of quantitative interpretation based on the results of measurements using a handheld XRF device, high accuracy of measurements is required. This paper presents the problems to which attention should be paid when applying the assumed methodology, mainly related to the underestimated percentages for light (main) elements. The tests were carried out on powdered samples of drill cores taken from borehole directed to Rotliegend rocks. The measurements were carried out using Bruker’s XRF S1 TITAN spectrometer. The calibration and correction tests led to the elimination of two factors affecting the inaccuracy of the analyses. The first is the progressive aging of the X-ray tube, which should be checked by conducting systematic measurements of the standard reference material. The second concerns the effect of a change in the density of the sample after grinding, which has a significant impact on light elements (mainly silicon and aluminium), causing a decrease in absolute values in the results of measurements using a handheld XRF device. Due to the type of rock material analysed, the focus was on the calibration of the results of the main elements building the Rotliegend sandstone rock matrix. The paper presents the possibility of calibrating the results directly in the device, which results in obtaining calibrated results after each measurement, as well as calibration of results in an external file. By using external calibration, errors caused by changing the rock matrix can be avoided while ensuring that possibility the results can be recalculated. The resulting calibration coefficients are applicable to the Rotliegend rocks and the XRF spectrometer with current software and GeoChem calibrations provided by Bruker. A change in any of the factors requires re-testing and recalibration of the results. Mineralogical models prepared based on XRF analyses can be used in the future, if those appropriate calibration coefficients are used.
Źródło:
Nafta-Gaz; 2020, 76, 1; 12-17
0867-8871
Pojawia się w:
Nafta-Gaz
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Elemental analysis of sediments from the urban storm water drainage depending on granulometric fractions
Analiza elementarna osadów pochodzących z miejskiej kanalizacji deszczowej w zależności od frakcji granulometrycznych
Autorzy:
Sałata, A.
Dąbek, L.
Powiązania:
https://bibliotekanauki.pl/articles/402153.pdf
Data publikacji:
2010
Wydawca:
Politechnika Świętokrzyska w Kielcach. Wydawnictwo PŚw
Tematy:
osady ściekowe
kanalizacja
analiza granulometryczna
skaningowy mikroskop elektronowy
wody opadowe
runoff sediments
sewer
granulometric analysis
scanning electron microscope
elemental composition
Opis:
This is an investigation of the physical and chemical properties of sediments from the urban storm water drainage to determine the relationship between its quality and particle size. The catchment area of 85 ha is located in the center of the city with the main thoroughfares. The study included: granulometric analysis, content of mineral and organic substances, elemental composition and Scanning Electron Microscope (SEM) analysis. The results showed presence of eleven particular fractions, content of mineral substances on the level 80.46%. and organic substances on the level 19.54%. Article presents also the results of studies of elemental composition and SEM analysis in the sediments depending on the factions to confirm significant part of minerals.
Źródło:
Structure and Environment; 2010, 2. no. 4; 25-28
2081-1500
Pojawia się w:
Structure and Environment
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wpływ emisji komunikacyjnej na stężenie dwóch form węgla i rozkład ich masy względem wielkości cząstek w aerozolu atmosferycznym obszaru miejskiego
Influence of Vehicular Traffic on Ambient Concentration and Mass Size Distribution of Two Fractions of Carbon in an Urban Area Atmospheric Aerosol
Autorzy:
Rogula-Kozłowska, W.
Rogula-Kopiec, P.
Klejnowski, K.
Błaszczyk, J.
Powiązania:
https://bibliotekanauki.pl/articles/1819029.pdf
Data publikacji:
2013
Wydawca:
Politechnika Koszalińska. Wydawnictwo Uczelniane
Tematy:
obszar miejski
emisja komunikacyjna
particulate air-pollution
diesel exhaust particles
chemical composition
elemental carbon
organic carbon
road
vehicles
matter
Opis:
Ambient particulate matter (PM) is a component of the natural environment and a certain number of particles that varies with time, having many different properties which also change over time, is constantly present in the air. It can be assumed that the scope of environmental effects of PM is the broadest among all air pollutants: it affects the human health, climate, ecological conditions and visibility. Organic carbon (OC) and elemental carbon (EC) are the two most important components of suspended dust. The continuously increasing road traffic intensity is highly correlated with increasing concentrations of both of these components in the air of urbanized areas all over the world. In spite of this, the amount of data on OC and EC concentrations in Poland is still insufficient, especially in the case of areas located close to busy roads. The aim of this study was to determine the influence of vehicular traffic on ambient concentrations of PM-related OC and EC, and their mass size distribution in a typical urban area of the Upper Silesia. PM samples were collected simultaneously at two sites located in the Katowice city. One of the selected measurement points was situated in the city centre and characterized so-called urban background. The second measurement point, located near the A4 motorway, was in the area directly exposed to the influence of traffic emission. Dust was sampled during two measurement periods (2–10 August and 15–22 September 2011) using thirteen-stage impactors – DEKATI Ltd. (DLPI, Dekati Low Pressure Impactor). Analysis for the content of OC and EC in the collected dust samples was carried out by means of a thermo-optical method with the use of a Sunset Laboratory OC/EC carbon analyzer. During the entire measurement program strict adherence to the rigorous requirements for quality control of the obtained results was ensured. Concentrations of PM1-, PM2.5- and PM10-related OC and EC in Katowice, near the A4 motorway, were close to values obtained in other parts of the world in different measurement periods, at traffic sites of similar characteristics. Also values of the concentration ratio of OC bound to PM10 and PM2,5 (or PM2,5) were similar to quantities determined in different locations. In Katowice, due to municipal emission and poor quality of vehicles travelling the roads, also the coarse fraction of dust was enriched in EC. This situation is unusual in comparison to other regions. The effect of emission from engines of the cars travelling the motorway manifested itself mainly by elevated EC concentrations compared to the urban background site. For TSP the EC concentration was higher, five times in the beginning of August and two times in the second half of September. The largest differences between EC concentrations in the location near the motorway and in the urban background area were observed for the PM0.06–0.108, PM0.108–0.17 and PM0.17–0.26 fractions. In both measurement periods, at the traffic site in Katowice, the maxima of mass size distribution of EC were in the diameter range characteristic for soot emitted from Diesel engines (0.108–0.26µm). The fact that the influence of exhaust emission from vehicles travelling the motorway on EC concentrations was more pronounced in the second half of September than in the first half of August, was caused by larger EC emission from various sources in Katowice during the period following summer holidays. Concentrations of organic carbon bound to TSP in both measurement periods in Katowice was only 10% higher in the urban traffic site than in the urban background site. The largest differences between OC concentrations near the motorway and in the urban background are observed in the ranges 0.06–0.17 and 1.0–2.5 µm. Maxima of the mass size distribution of PM-related OC, both at the urban traffic site and at the background site, were similar in both measurement periods. It was inferred that the small differences between OC concentrations in the traffic and the background site are caused by the process of secondary aerosol formation, less intensive near the motorway than in the urban site.
Źródło:
Rocznik Ochrona Środowiska; 2013, Tom 15, cz. 2; 1623-1644
1506-218X
Pojawia się w:
Rocznik Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Molecular composition of humic substances isolated from selected soils and cryconite of the Grønfjorden area, Spitsbergen
Autorzy:
Polyakov, Vyacheslav
Zazovskaya, Elya
Abakumov, Evgeny
Powiązania:
https://bibliotekanauki.pl/articles/2041903.pdf
Data publikacji:
2019
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
Arctic
Svalbard
CP/MAS 13C-NMR
elemental composition
organic matter
Źródło:
Polish Polar Research; 2019, 40, 2; 105-120
0138-0338
2081-8262
Pojawia się w:
Polish Polar Research
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The origin and chronology of medieval silver coins based on the analysis of chemical composition
Autorzy:
Pańczyk, E.
Sartowska, B.
Waliś, L.
Dudek, J.
Weker, W.
Widawski, M.
Powiązania:
https://bibliotekanauki.pl/articles/147506.pdf
Data publikacji:
2015
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
elemental composition
medieval Central Europe coins
scanning electron microscopy (SEM)
laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS)
numismatists
Opis:
Medieval Central Europe coins – the Saxon coins, also called as the Otto and Adelheid denarii, as well as the Polish ones, the Władysław Herman and Bolesław Śmiały coins – were examined to determine their provenance and dating. Their attribution and chronology often constitute a serious problem for historians and numismatists. For hundreds of years, coins were in uncontrolled conditions and in variable environment. Destructed and inhomogeneous surface were the effect of corrosion processes. Electron microscopy with energy dispersive X-ray analysis (scanning electron microscopy with energy dispersive X-ray spectroscopy (SEM-EDS)), X-ray fluorescence (XRF) analysis (energy dispersive X-ray fluorescence (EDXRF) and total reflection X-ray fluorescence (TXRF)), and laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS) were applied. The results of these investigations are significant for our knowledge of the history of Central European coinage, especially of Polish coinage.
Źródło:
Nukleonika; 2015, 60, No. 3, part 2; 657-663
0029-5922
1508-5791
Pojawia się w:
Nukleonika
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Możliwości energetycznego wykorzystania osadów ściekowych jako paliwa
Possibilities of energy use sewage sludge as fuel
Autorzy:
Ostojski, A.
Gajewska, M.
Powiązania:
https://bibliotekanauki.pl/articles/297752.pdf
Data publikacji:
2014
Wydawca:
Politechnika Częstochowska. Wydawnictwo Politechniki Częstochowskiej
Tematy:
osady ściekowe
przekształcenie termiczne
skład pierwiastkowy
wartość opałowa
bilans energetyczny
sewage sludge
thermal processing
elemental composition
calorific value
energy balance
Opis:
Obecnie szeroko dyskutowana jest efektywność energetyczna oczyszczalni, stąd istotnym zagadnieniem staje się prawidłowe wykorzystanie potencjału energetycznego osadów ściekowych (CHP i ITPO). Realizacja termicznej przeróbki osadów ściekowych wymaga znajomości właściwości energetycznych (ciepło spalania, wartość opałowa, zawartość wody) oraz składu pierwiastkowego, wskazującego na zawartość substancji lotnych i mineralnych osadów przeznaczonych do spalania. W pracy przedstawiono wyniki badań prowadzonych w dwóch dużych trójmiejskich oczyszczalniach ścieków. Analizie poddano osady ściekowe po kolejnych stopniach przetwarzania, a więc osady surowe, zmieszane i przefermentowane. Wykazano, że osady ściekowe w obu analizowanych oczyszczalniach, pomimo innych warunków i procesów przeróbki, charakteryzowały się bardzo podobnym składem pierwiastkowym odwodnionych, przefermentowanych osadów C - 30÷31%, H - 4,5%, N - 4%, O - 26,5÷30%, S - 1%, przy zawartości popiołu 30÷33% (w odniesieniu do suchej masy). Wykazano, że osady są dobrym źródłem energii. Średnie ciepło spalania dla osadów nieprzefermentowanych wynosiło 17,5 MJ/kg, a proces fermentacji obniżał je jedynie o 20 do 30%. Oceniając uzyskane wyniki, zauważyć można, że szanse na autotermiczny proces spalania daje jedynie zastosowanie osadu wysuszonego. Gdynia posiada instalację do suszenia osadu i uzyskuje osady o wartości opałowej wynoszącej około 10 MJ/kg przy 30% zawartości popiołu. W tym przypadku jedna tona węgla kamiennego jest równoważna energetycznie 3 tonom suchego osadu.
Energy efficiency of WWTP is currently widely discussed thus sewage sludge processing becomes an important issue hence it could be a potential source of energy (CHP and ITPO). Execution of thermal sludge treatment requires knowledge of the energetic properties (heat of combustion, calorific value, water content) and elemental composition indicating content of volatile substances and mineral deposits to be incinerated. The paper presents the results of research carried out in two major WWTP Tricities. The sludge after subsequent stages of processing : raw, mixed and fermented sludge were analyzed. It has been shown that sludge in both analyzed WWTPs, in spite of other conditions and treatment processes, showed very similar properties in case of digested and dewatered ones: C - 30÷31%, H - 4.5%, N - 4%, O - 26.5÷30% S - 1%, with ash content of 30-33% (based on dry weight). It has been shown that the sludge could be a good source of energy. Average heat of combustion for undigested sludge was 17.8 MJ/kg and the fermentation process decreased it only by 20 to 30%. When evaluating the results it can be seen that the chances of autothermal combustion process gives only the use of the dried sludge (not digested one). Gdynia WWTP is equipped with installation for sludge drying and in this way and obtained calorific value is of about 10 MJ/kg at 30% ash content. In this case, one ton of coal energy is equivalent to three tons of dry sludge.
Źródło:
Inżynieria i Ochrona Środowiska; 2014, 17, 4; 521-531
1505-3695
2391-7253
Pojawia się w:
Inżynieria i Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Znaczenie potencjału energetycznego osadów ściekowych w aspekcie gospodarki o obiegu zamkniętym – przykład oczyszczalni w Gdańsku
Importance of Energy Potential of Sewage Sludge in Terms of Closed Circuit Management – the "Wschód" WWTP Case Study
Autorzy:
Ostojski, A.
Swinarski, M.
Powiązania:
https://bibliotekanauki.pl/articles/1813751.pdf
Data publikacji:
2018
Wydawca:
Politechnika Koszalińska. Wydawnictwo Uczelniane
Tematy:
osady ściekowe
biogaz
energia cieplna
energia elektryczna
skład pierwiastkowy
ciepło spalania
wartość opałowa
sewage sludge
biogas
heat
electricity
elemental composition
higher heating value
HHV
lover heating value
LHV
Opis:
W artykule przedstawiono ciepło spalania, wartość opałową oraz skład pierwiastkowy osadów ściekowych na kolejnych etapach przeróbki w oczyszczalni ścieków "Wschód" w Gdańsku. Osad ściekowy jest cennym źródłem energii. Średnia wartość ciepła spalania (HHV) osadów ściekowych w oczyszczalni ścieków w Gdańsku wynosi 14-15 MJ/kg dla osadów przefermentowanych i 17,5 MJ/kg dla osadów przed fermentacją. Niestety wysoka ich wilgotność, obniża wartość opałową i utrudnia skuteczne odzyskiwanie energii z osadów. Pomimo około 70% wilgotności, osady są spalane w złożu fluidalnym w instalacji ITPO w oczyszczalni. Termiczna utylizacja przebiega w temperaturze 850-870° odbywa się autotermicznie. Gospodarka osadowa, obejmująca fermentację w ZKF wraz z produkcją biogazu i wykorzystanie metanu w systemie produkcji energii elektrycznej i ciepła, suszenie, spalanie w piecu fluidalnym i ostatecznie, odzyskiwanie ciepła z gazów spalinowych, generuje dodatni bilans energetyczny. Stwarza to możliwość wykorzystania energii elektrycznej oraz cieplnej w procesach oczyszczania ścieków i pełnego zamknięcia bilansu produkowanej i zużywanej energii w całej oczyszczalni. W oczyszczalni ścieków "Wschód" w Gdańsku obieg energetyczny nie jest jeszcze zamknięty. Konieczne jest intensyfikacja produkcji energii elektrycznej lub/i zmniejszenie jej zużycia w procesach oczyszczania ścieków. Najwięcej energii pozyskiwane jest z elektrowni biogazowej. Wartość opałowa biogazu z osadów w Gdańsku wynosi 21,34 MJ/Nm3. Pozwala to uznać osady ściekowe za bardzo wydajne źródło energii. Ilość wytworzonej energii cieplnej (SPE i ITPO) jest znacznie wyższa niż potrzeby oczyszczalni. Produkcja energii elektrycznej netto w systemie SPE, po odjęciu energii zużytej przez instalację ITPO, zapewnia około 68% całkowitego zużycia energii w oczyszczalni ścieków. Instalacja termicznej konwersji osadów ściekowych, która działa w Gdańsku, spełnia wymagania Dyrektywy Parlamentu Europejskiego (IPPC DYREKTYWA 2008/1/WE) o zintegrowanym zapobieganiu zanieczyszczeniom i ich kontroli. Monospalarnia pozwala na wykorzystanie całej ilości wytworzonego osadu. Pomimo dużej zawartości wody w osadzie, co zmniejsza jego potencjał energetyczny, proces spalania nie wymaga dodatkowego paliwa (poza fazą rozruchu lub stanem utrzymywania gotowości). Obecnie nie ma alternatywy dla termicznego wykorzystania osadów ściekowych, zwłaszcza w dużych oczyszczalniach ścieków. Problem ostatecznego usuwania popiołów paleniskowych pozostaje jednak nierozwiązany. Jest to ważna kwestia w kontekście postulatu zarządzania zamkniętym cyklem, przyjętego w 2015 roku.
In the article the higher heating values (HHV), lower heating values (LHV) and elemental composition of sewage sludge at subsequent stages of processing in wastewater treatment plant (WWTP) “Wschód” in Gdańsk are presented. Sewage sludge is a valuable source of energy. The average value of the HHV of sewage sludge in the sewage treatment plant in Gdańsk is 14-15 MJ/kg for digested sludge and 17.5 MJ/kg for non-fermented sludge. However, high humidity, which reduces their heating value, hinders effective energy recovery from the sludge. Despite the high humidity (about 70%), the sediments are successfully burned in the fluidized bed in the sewage thermal treatment plants (ITPO). Burning at 850-870º takes place autothermally. Adequate processing, consisting of biogas production and methane utilization within Electricity and Heat production system, drying, combustion in a fluidized furnace and, finally, heat recovery from the exhaust gases, creates an opportunity of achieving full balance of energy produced and consumed. In WWTP “Wschód” in Gdańsk the energy balance is incomplete yet. It is necessary to supplement the electric energy or/and to decrease energy consumption in sewage treatment processes. The largest energy contribution is obtained from the biogas power plant and thanks to the biogas generated from sediments, it is possible to recognize them as a very efficient source of energy. The calorific value of this fuel in Gdansk is 21.34 MJ/Nm3. The amount of thermal energy produced (SPE and ITPO) is much higher than the needs of the treatment plant. The net electricity production in the SPE system, after deducting the energy consumed by the ITPO installation, accounts for about 68% of the total energy consumption at the sewage treatment plant. The installation of thermal conversion of sewage sludge which is working in Gdańsk meets the objectives of European Parliament Directive (IPPC DIRECTIVE 2008/1/EC) regarding integrated prevention and pollution control. The mono-combustion plant allows for utilization of the total amount of produced sludge. Despite of high water content in the sludge, which decreases its energetic potential, the combustion process does not require additional fuel (apart from the start-up phase or stanby conditions). At present there is no alternative for thermal sewage sludge utilization, especially at large WWTPs. However, the problem of final disposal of combustion ashes remains unsolved. This is an important issue in the context of the postulate of closed cycle management that was accepted in 2015.
Źródło:
Rocznik Ochrona Środowiska; 2018, Tom 20, cz. 2; 1252-1268
1506-218X
Pojawia się w:
Rocznik Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Ocena zawartości wybranych pierwiastków w różnych rodzajach czekolad
Assessing contents of selected elements in different types of chocolates
Autorzy:
Olechnowicz, J.
Staniek, H.
Powiązania:
https://bibliotekanauki.pl/articles/826492.pdf
Data publikacji:
2017
Wydawca:
Polskie Towarzystwo Technologów Żywności
Tematy:
czekolada
czekolada biala
czekolada mleczna
czekolada gorzka
pierwiastki chemiczne
wapn
magnez
miedz
zelazo
mangan
cynk
zawartosc pierwiastkow
zawartosc wapnia
zawartosc magnezu
zawartosc miedzi
zawartosc zelaza
zawartosc manganu
zawartosc cynku
chocolate
white chocolate
milk chocolate
dark chocolate
chemical element
calcium
magnesium
copper
iron
manganese
zinc
elemental composition
calcium content
magnesium content
copper content
iron content
manganese content
zinc content
Opis:
Celem pracy była ocena zawartości wybranych pierwiastków (Ca, Mg, Cu, Fe, Mn i Zn) w różnych rodzajach czekolad. Analizie poddano 20 czekolad, w tym: białe (B), mleczne (M) i gorzkie (G) o różnej zawartości masy kakaowej. Pogrupowano je według zawartości suchej masy kakaowej następująco [%]: G6 – 60, G7 – 70, G8 – do 85, G9 – 90. Suchą masę w próbkach oznaczono metodą suszarkowo-wagową. Oznaczenie zawartości Ca, Mg, Cu, Fe, Mn i Zn wykonano metodą płomieniowej atomowej spektrometrii absorpcyjnej (F-AAS) przy użyciu spektrometru AAS-3 Carl-Zeiss po uprzedniej mineralizacji próbek techniką spopielenia w piecu muflowym. Zaobserwowano istotnie większą zawartość Mg, Fe, Zn, Mn oraz Cu w czekoladach gorzkich w porównaniu z czekoladami mleczną i białą. Zawartość tych pierwiastków była tym większa, im większy był udział kakao w czekoladzie. W czekoladach gorzkich zawartość magnezu wynosiła 1545,40 ÷ 2862,55 μg/g s.m. Wykazano także znaczne ilości cynku (356,70 ÷ 511,35 μg/g s.m.) i żelaza (127,47 ÷ 155,74 μg/g s.m.), a mniejsze – miedzi (16,49 ÷ 25,37 μg/g s.m.) i manganu (15,85 ÷ 21,46 μg/g s.m.). Z kolei w czekoladach mlecznych i białych przeważał wapń, którego zawartość wahała się w granicach 3396,21 ÷ 4313,44 μg/g s.m. Czekolady gorzkie o większej zawartości suchej masy kakaowej mogą być dobrym źródłem Mg, Fe, Zn oraz Mn i Cu w diecie. Natomiast znaczącymi nośnikami wapnia mogą być czekolady białe i mleczne.
The objective of the research study was to assess the contents of some selected elements (Ca, Mg, Cu, Fe, Mn, and Zn) in different types of chocolates. 20 chocolates were analyzed, including: white chocolates (B), milk chocolates (M), and dark chocolates (G) with various contents of cocoa mass. Based on the content of dry cocoa mass, they were grouped as follows [%]: G6: 60; G7: 70 %; G8: up to 85; G9: 90 %. The dry mass in the samples was determined using a dry oven test. The contents of Ca, Mg, Cu, Fe, Mn, and Zn were determined by a flame atomic absorption spectrophotometry (F-AAS) method using an AAS3 Carl-Zeiss spectrometer (Jena, Germany) after the “dry” method mineralization of samples in a muffle furnace. It was found that the contents of Mg, Fe, Cu, Mn, and Zn were significantly higher in the dark chocolates than in the milk and white chocolates. The content of those elements was the higher the greater the cocoa content therein was. In the dark chocolates, the content of magnesium was between 1545.40 μg/g and 2862.55 μg/g d.m. There were shown considerable contents of zinc (356.70 ÷ 511.35 μg/g d.m.) and iron (127.47 ÷ 155.74 μg/g s.m.) and lower contents of copper (16.49 ÷ 25.37 μg/g d.m.) and manganese (15.85 ÷ 21.46 μg/g s.m.). Then, calcium was prevalent in the milk and whites chocolates and its content ranged between 3396.21 μg/g d.m. and 4313.44 μg/g d.m. The dark chocolates with a higher content of dry matter can be a good source of Mg, Fe, Zn, Mn, and Cu in the diet. And white and milk chocolates can be significant carriers of calcium.
Źródło:
Żywność Nauka Technologia Jakość; 2017, 24, 1
1425-6959
Pojawia się w:
Żywność Nauka Technologia Jakość
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Between-population variation in plant performance traits and elemental composition of Colchicum autumnale L. and its relation to edaphic environments
Autorzy:
Mroz, L
Powiązania:
https://bibliotekanauki.pl/articles/57397.pdf
Data publikacji:
2008
Wydawca:
Polskie Towarzystwo Botaniczne
Tematy:
population variation
plant performance
vegetative performance
reproductive performance
elemental composition
mineral composition
parent material
soil property
redundancy analysis
Colchicum autumnale
edaphic environment
Opis:
Variation in vegetative and reproductive performance and leaf mineral composition among 25 populations of Colchicum autumnale (meadow saffron) from soils derived from six parent materials (limestone, marl, sandstone, greenstone, melaphyre and serpentine) in southwestern Poland has been investigated. The plant size (PS), total le-af area (TLA), leaf shape (LS), number of fruits per plant (NFP), number of seeds per plant (NFP), total weight seed per plant (TWSP) were estimated, and concentrations of seventeen elements (N, P, K, Ca, Mg, Na, S, Fe, Mn, Cu, Zn, Pb, Cd, Ni, Co, Cr, Mo) were analyzed in leaf and soil samples. In soil samples, also soil pH, organic matter content and sand, silt and clay content were determined. All soils (except melaphyre soil) contained elevated levels of Cr. Concentrations of soil Ni and Zn, Pb, Cd in serpentinite soil and polluted marl soils (respectively) were significantly higher than those of other examined soils. Meadow saffron leaves from all sites (except marl sites) contained elevated levels of Cr, Co and Ni. Statistical analysis, carried out with principal component analysis (PCA) revealed that a good correlation exists between the element content in leaves and plant performance traits and soil environment. The leaf Ca content and NFP were correlated and were much higher in populations from metal (except Cr) and nutrient-poor marl soils than in those from metal (except Ni in serpentine soil)and nutrient moderate rich soils derived from melaphyre, greenstones, serpentinite, limestones and sandstones and in those from metal-rich and nutrient-poor polluted marl soils. Meadow saffron plants tended to take up higher amounts of N, P, K, Mn, Cu and Na and lower amounts of S and had much higher TLA in populations from sandstone soils than those in populations from serpentinite, melaphyre, greenstone, marl and limestone soils. The leaf Co, Ni, Cr, Mg concentrations were correlated and were much higher in populations from serpentinite, melaphyre, greenstone, polluted marl and limestone soils than those from marl and sandstone soils. The pattern of variation in NFP and TLA across the different soil types was the opposite of that for leaf N, Cu, Na, Ni, Mg and S concentrations. Redundancy analysis (RDA) enables identification of the soil variables that best explain the variance pattern of plant response. The variation explained by the soil variables (15 soil elements and soil pH) was high (79%). The forward selection of soil variables identified soil Co, Mo, Ni, Ca and Zn concentrations as significantly influencing the ordination plant traits. The variation explained by these selected variables was 55%. Thus the five soil variables appeared to be the main factors determining the pattern variation of vegetative, reproductive and nutrient traits of Colchicum autumnale.
Źródło:
Acta Societatis Botanicorum Poloniae; 2008, 77, 3; 229-239
0001-6977
2083-9480
Pojawia się w:
Acta Societatis Botanicorum Poloniae
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies