Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "electron-beam radiation" wg kryterium: Temat


Tytuł:
Mechanical and thermal properties of commercial multilayer flexible plastic packaging materials irradiated with electron beam
Autorzy:
Oliveira, V. M.
Nogueira, B. R.
Ortiz, A. V.
Moura, E. A. B.
Powiązania:
https://bibliotekanauki.pl/articles/146772.pdf
Data publikacji:
2008
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
electron-beam radiation
multilayer packaging materials
mechanical properties
thermal properties
Opis:
The effects of electron-beam irradiation on mechanical and thermal properties were studied for two commercial multilayer structures of flexible food packaging. Both the laminated poly(ethylene terephthalate) (PET)/ low-density polyethylene (LDPE) and the coextruded LDPE/polyamide(PA)/LDPE structures were irradiated up to 120 kGy using a 1.5 MeV electron beam accelerator, at room temperature in the presence of air. Mechanical properties showed significant changes (p < 0.05), specially in sealability that was severely affected. Changes in mechanical properties were discussed in relation to the eight day and the six month period after irradiation. In addition, the DSC analysis six months after treatment showed that the fusion enthalpy of the PET/LDPE structure components increase for the LDPE from 10 kGy and decrease for the PET up to 120 kGy (p < 0.05). On the other hand, the LDPE/PA6/ LDPE presented increase in the LDPE and PA up to 120 kGy, except for LDPE at 10 and 15 kGy and PA at 5 kGy doses (p < 0.05). The effects of irradiation were less severe for the LDPE/PA6/LDPE than for the PET/LDPE. The electron-beam irradiation did not show advantageous results that could be of interest for commercial applications for the film industry, but brings important information about the packaging behavior for food producers who may decide to use irradiation as a form of cold pasteurization of their packed products.
Źródło:
Nukleonika; 2008, 53, suppl. 2; 141-144
0029-5922
1508-5791
Pojawia się w:
Nukleonika
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Badanie metodą EPR wolnych rodników w polimerze UHMWPE stosowanym w biomedycznych węzłach tarcia
The EPR method investigation of free radicals in polymer UHMWPE applied in the biomedical knots of the friction
Autorzy:
Czaja, P.
Cybo, J.
Maszybrocka, J.
Barylski, A.
Michniowski, J.
Powiązania:
https://bibliotekanauki.pl/articles/189804.pdf
Data publikacji:
2011
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
polietylen UHMWPE
napromieniowanie strumieniem elektronów
wolne rodniki
EPR
polyethylene UHMWPE
electron beam radiation
free radicals
EPR method
Opis:
W artykule zostały przedstawione wyniki badań EPR wolnych rodników dla dwu gatunków polietylenu o ultrawysokiej masie cząsteczkowej: GUR 1020 i GUR 1050, poddanych napromieniowaniu wiązką elektronów o energii 10 MeV i o krotności napromieniowania i = 1, 2, 3, 4, 6, dawką o mocy 26 kGy. Wraz ze wzrostem dawki promieniowania zwiększa się ilość wolnych rodników w badanym materiale. Zarówno w przypadku polietylenu GUR 1020, jak i GUR 1050 nie obserwuje się stanu nasycenia przy maksymalnej dawce promieniowania równej 156 kGy. Świadczyć to może o zbliżonej odporności radiacyjnej badanych materiałów.
In this paper, the results of EPR measuring of free radicals for two types of polyethylene of ultra high molecular weight: GUR 1020 and GUR 1050 are presented. Samples were irradiated by electron beam energy of 10 MeV and dose 26 kGy a number of times (i = 1, 2, 3, 4, or 6). With the increase of radiation, the amount of free radicals increases as well. In both cases of polyethylene GUR 1020 and GUR 1050, the effect of saturation at the maximum dose of radiation equal 156 kGy was not observed. This proves that both types of material show similar radiation resistance.
Źródło:
Tribologia; 2011, 5; 39-47
0208-7774
Pojawia się w:
Tribologia
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wpływ promieniowania elektronowego na bioresorbowalne terpolimery zawierające paklitaksel
The influence of electron beam radiation on bioresorbable terpolymers containing paclitaxel
Autorzy:
Musiał-Kulik, M.
Kasperczyk, J.
Jelonek, K.
Gębarowska, K.
Janeczek, H.
Dobrzyński, P.
Powiązania:
https://bibliotekanauki.pl/articles/284820.pdf
Data publikacji:
2010
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie. Polskie Towarzystwo Biominerałów
Tematy:
bioresorbowalne terpolimery
paklitaksel
promieniowanie elektronowe
sterylizacja
polimery z pamięcią kształtu
bioresorbable terpolymers
paclitaxel
electron beam radiation
sterilization
shape memory polymers
Opis:
Sterylizacja jest bardzo ważnym czynnikiem uzależniającym przydatność materiałów do zastosowań medycznych. Obiecującą metodą sterylizacji wydaje się być promieniowanie wiązką elektronową. Celem badania była analiza wpływu promieniowania elektro-nowego (EB) na terpolimery zawierające paklitaksel. Dwa typy materiałów użyto do przygotowania matryc zawierających 5 i 10% leku, jak również matryc bez leku: poli(L-laktyd-ko-glikolid-ko-ε-kaprolakton) (44:32:24) – P(LA:GA:Cap) oraz poli(L-laktyd-ko-gli-kolid-ko-węglan trimetylenu) (62:27:11) – P(LA:GA:TMC). Wszystkie otrzymane matryce badano przed i po procesie elektronowego napromieniania dawką 25kGy za pomocą spektroskopii NMR, DSC i GPC. Nie wykazano różnic w składzie komonomerów, temperaturze zeszklenia, liczbowo średniej masie cząsteczkowej jak również w rozrzucie mas cząsteczkowych (dyspersyjność) pomiędzy matrycami otrzymanymi z tego samego typu terpolimeru przed procesem sterylizacji. Promieniowanie elektronowe spowodowało spadek liczbowo średniej masy cząsteczkowej oraz temperatury zeszklenia. Zmiany w składzie komonomerów zauważono tylko w przypadku matryc z P(LA:GA:Cap), co może sugerować mniejszą odporność jednostek kaproilowych na sterylizację.
Sterilization is a very important factor determining usefulness of materials for medical application. The promising method of sterilization seems to be electron beam radiation. The aim of this study was to analyze the influence of the EB radiation on terpolymers containing paclitaxel. Two types of materials were used to prepare three kinds of matrices – with 5% and 10% of paclitaxel as well as drug free matrices. The selected terpolymers were: poly(L-lactide-co-glycolide-co-ε-caprolactone) (44:32:24) – P(LA:GA:Cap) and poly(L-lactide-co-glycolide-co-trimethylene carbon-ate) (62:27:11) – P(LA:GA:TMC). All of the obtained matrices were investigated before and after electron beam (EB) irradiation with the dose of 25 kGy with the use of 1H NMR spectroscopy, DSC and GPC. There were no differences in comonomer molar ratio, glass transition temperature, the number average molecular weight and dispersity index between non-irradiated matrices prepared from the same terpolymer type, regardless paclitaxel content. EB radiation caused decrease of the number average molecular weight as well as the glass-transition temperature. The changes of comonomer units’ ratio were noticed only in the case of P(LA:GA:Cap) matrices that may suggest lower susceptibility to sterilization of caproyl units.
Źródło:
Engineering of Biomaterials; 2010, 13, 94; 24-27
1429-7248
Pojawia się w:
Engineering of Biomaterials
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Sterylizacja radiacyjna bioresorbowalnych kopolimerów zawierających lek cytostatyczny
Radiation sterilization of bioresorbable copolymers with the cytostatic drug
Autorzy:
Musiał-Kulik, M.
Gębarowska, K.
Janeczek, H.
Pastusiak, M.
Kasperczyk, J.
Dobrzyński, P.
Powiązania:
https://bibliotekanauki.pl/articles/284740.pdf
Data publikacji:
2013
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie. Polskie Towarzystwo Biominerałów
Tematy:
poli(L-laktydo-ko-węglan trimetylen)
paklitaksel
promieniowanie gamma
napromienianie wiązką elektronów
sterylizacja
poly(L-lactide-co-trimethylene carbonate)
paclitaxel
gamma irradiation
electron beam radiation
sterilization
Opis:
Istnieje wiele metod sterylizacji wyrobów medycznych. Jednak najbardziej użytecznymi metodami sterylizacji syntetycznych, bioresorbowalnych polimerów wydają się być promieniowanie gamma oraz napromienianie wiązką elektronów (EB). Celem tej pracy było określenie wpływu wspomnianych metod na trzy rodzaje matryc - zawierających 3%, 5% paklitakselu oraz matryc bez leku. Badane matryce otrzymano z dwóch rodzajówpoli(L-laktydo-ko-węglanu trimetylenu) zsyntezowanych w 150°C (P1) oraz 120°C (P2). Nie zaobserwowano znaczących różnic w składzie komonomerów matryc sterylnych i niesterylnych, zawierających paklitaksel, jak i matryc bez leku. Spadek temperatury zeszklenia (Tg) wynikał ze zmniejszenia się średniej długości bloków laktydylowych oraz węglanowych, a także utraty Mn po procesie sterylizacji. Zauważalne były niewielkie różnice we właściwościach fizykochemicznych matryc napromienianych promieniowaniem gamma oraz wiązką elektronów. Otrzymane wyniki pokazują, iż lepszą metodą sterylizacji poli(L-laktydo-ko-węglanu trimetylenu) wydaje się być napromienianie wiązką elektronów.
There are many methods of sterilization approved for medical devices. However, the most usable methods of synthetic, bioresorbable polymers sterilization seem to be gamma radiation and electron beam irradiation (EB). The aim of this work was to determine the impact of mentioned methods on three types of matrices - containing 3%, 5% of paclitaxel and also drug free matrices. The studied matrices were obtained from two poly(L-lactide-co-trimethylene-carbonates) synthesized at 150°C (P1) and 120°C (P2). No significant differences of comonomers' composition were observed in sterile and non-sterile matrices containing paclitaxel as well as drug free matrices. The decrease of the glass transition temperature (Tg) resulted from decrease of the lactidyl and carbonate units' content and the Mn loss after radiation. Small dissimilarities of physicochemical features between gamma and EB radiated matrices were noticeable. Thus, the obtained data showed that better method of sterilization of poly(L-lactide-co-trimethylene carbonates) seems to be electron beam radiation.
Źródło:
Engineering of Biomaterials; 2013, 16, 118; 18-22
1429-7248
Pojawia się w:
Engineering of Biomaterials
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Sterylizacja radiacyjna bioresorbowalnych kopolimerów zawierających lek cytostatyczny
Radiation sterilization of bioresorbable copolymers with the cytostatic drug
Autorzy:
Musiał-Kulik, M.
Gębarowska, K.
Janeczek, H.
Pastusiak, M.
Kasperczyk, J.
Dobrzyński, P.
Powiązania:
https://bibliotekanauki.pl/articles/286205.pdf
Data publikacji:
2012
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie. Polskie Towarzystwo Biominerałów
Tematy:
poli(L-laktydo-ko-węglan trimetylen)
paklitaksel
promieniowanie gamma
napromieniowanie wiązką elektronów
sterylizacja
poly(L-lactide-co-trimethylene carbonate)
paclitaxel
gamma irradiation
electron beam radiation
sterilization
Opis:
Istnieje wiele metod sterylizacji wyrobów medycznych. Jednak najbardziej użytecznymi metodami sterylizacji syntetycznych, bioresorbowalnych polimerów wydają się być promieniowanie gamma oraz napromienianie wiązką elektronów (EB). Celem tej pracy było określenie wpływu wspomnianych metod na trzy rodzaje matryc - zawierających 3%, 5% paklitakselu oraz matryc bez leku. Badane matryce otrzymano z dwóch rodzajów poli(L-laktydo-ko-węglanu trimetylenu) zsyntezowanych w 150°C (P1) oraz 120°C (P2). Nie zaobserwowano znaczących różnic w składzie komonomerów matryc sterylnych i niesterylnych, zawierających paklitaksel, jak i matryc bez leku. Spadek temperatury zeszklenia, Tg, wynikał ze zmniejszenia się średniej długości bloków laktydylowych oraz węglanowych, a także utraty Mn po procesie sterylizacji. Zauważalne były niewielkie różnice we właściwościach fizykochemicznych matryc napromienianych promieniowaniem gamma oraz wiązką elektronów. Otrzymane wyniki pokazują, iż lepszą metodą sterylizacji poli(L-laktydo-ko-węglanu trimetylenu) wydaje się być napromienianie wiązką elektronów.
There are many methods of sterilization approved for medical devices. However, the most usable methods of synthetic, bioresorbable polymers sterilization seem to be gamma radiation and electron beam irradiation (EB). The aim of this work was to determine the impact of mentioned methods on three types of matrices - containing 3%, 5% of paclitaxel and also drug free matrices. The studied matrices were obtained from two poly(L-lactide-co-trimethylene-carbonates) synthesized at 150°C (P1) and 120°C (P2). No significant differences of comonomers' composition were observed in sterile and non-sterile matrices containing paclitaxel as well as drug free matrices. The decrease of the glass transition temperature, Tg, resulted from decrease of the lactidyl and carbonate units' content and the Mn loss after radiation. Small dissimilarities of physicochemical features between gamma and EB radiated matrices were noticeable. Thus, the obtained data showed that better method of sterilization poly(L-lactide-co-trimethylene carbonates) seems to be electron beam radiation.
Źródło:
Engineering of Biomaterials; 2012, 15, no. 116-117 spec. iss.; 74-78
1429-7248
Pojawia się w:
Engineering of Biomaterials
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Atomic force microscopy investigation of electron beam (EB) irradiated composites based on biodegradable polymers and coconut fiber*
Autorzy:
Kodama, Y.
Oishi, A.
Nagasawa, N.
Nakayama, K.
Tamada, M.
Machado, L. D. B.
Powiązania:
https://bibliotekanauki.pl/articles/147470.pdf
Data publikacji:
2013
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
atomic force microscopy (AFM)
coconut fiber
electron beam (EB) radiation
force modulation microscopy (FMM)
poly(ε-caprolactone) (PCL)
poly(L-lactic acid) (PLLA)
scanning electron microscopy (SEM)
Opis:
In this study, the addition of natural fibers to biodegradable PCL, PLLA blend and the effect of ionizing radiation on the surface of composites were investigated by force modulation microscopy (FMM), atomic force microscopy (AFM) and scanning electron microscopy (SEM). Hot pressed sheets were prepared using pellets of twin extruded PCL:PLLA 20:80 (w:w) blend containing 5% or 10% weight concentration of coconut fiber. In this study coconut fibers non treated chemically and acetylated ones were used. Irradiation was performed using an electron beam (EB) accelerator and an absorbed dose of 100 kGy. FMM images acquisition was obtained using a silicon cantilever, intermittent contact mode (tapping mode). Also, AFM images were obtained using tapping mode but J scanner. By FMM, it was possible to observe regions with different elasticity indicating fiber presence under the surface of the composite. Furthermore, it appears that the spherical structures size decreased on composites. This probably was induced by ionizing radiation.
Źródło:
Nukleonika; 2013, 58, 4; 459-468
0029-5922
1508-5791
Pojawia się w:
Nukleonika
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Radiation processing of polymers and semiconductors at the Institute of Nuclear Chemistry and Technology
Autorzy:
Zimek, Z.
Przybytniak, G.
Kałuska, I.
Powiązania:
https://bibliotekanauki.pl/articles/146107.pdf
Data publikacji:
2006
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
electron beam accelerators
radiation processing
Opis:
R&D studies in the field of radiation technology in Poland are mostly concentrated at the Institute of Nuclear Chemistry and Technology (INCT). The results of the INCT works on polymer and semiconductor modification have been implemented in various branches of national economy, particularly in industry and medicine. Radiation technology for polymer modification was implemented in the middle of the 1970-ties. Among others, the processes of irradiation and heat shrinkable products expansion have been developed. The transfer of this technology to Polish industry was performed in the middle of the 1980-ties. The present study aims at the formulation of new PE composites better suited to new generation of heat shrinkable products, for example, a new generation of hot-melt adhesives has been developed to meet specific requirements of customers. Modified polypropylene was used for the production of medical devices sterilized by radiation, especially disposable syringes, to overcome the low radiation resistance of the basic material. Modified polypropylene (PP-M) has been formulated at the INCT to provide material suitable for medical application and radiation sterilization process. Modification of semiconductor devices by EB was applied on an industrial scale since 1978 when the INCT and the LAMINA semiconductor factory successfully adopted that technology to improve specific semiconductor devices. This activity is continued on commercial basis where the INCT facilities served to contract irradiation of certain semiconductor devices according to the manufacturing program of the Polish factory and customers from abroad.
Źródło:
Nukleonika; 2006, 51,suppl.1; 129-132
0029-5922
1508-5791
Pojawia się w:
Nukleonika
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Specific heat of selected graphites used in calorimetry of electron beam and its influence on the accuracy of measurement of large dose
Autorzy:
Panta, P.
Głuszewski, W.
Powiązania:
https://bibliotekanauki.pl/articles/147858.pdf
Data publikacji:
2005
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
radiation processing
radiation sterilization
electron beam (EB)
high dose calorimetry
calibration
electron energy
Opis:
Calorimetry is applicable to both absolute calibration of routine dosimeters and absolute measurements of electron beam (EB) intensity (for industrial radiation processing). Advantages of graphite as the absorbing calorimetric material are a good heat capacity and negligible heat defect of this material. Knowledge of the specific heat capacities of the calorimetric core materials is fundamental in making absolute dose measurements. Two kinds of high-purity graphite used in calorimeters were analysed, i.e. Union Carbide grade AGOT and nuclear grade graphite [10]. There are some differences of specific heat of these graphites, up to 2% , which influence dosimetric response of calorimeters made of them.
Źródło:
Nukleonika; 2005, 50,suppl.2; 55-57
0029-5922
1508-5791
Pojawia się w:
Nukleonika
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Combination of methods of thermal and radiation treatment of sediments associated with PCBs : the Delor type
Autorzy:
Fülöp, Marko
Šagátová, Andrea
Benkovský, Ivan
Prokes, Karel
Foltinova, Lubica
Powiązania:
https://bibliotekanauki.pl/articles/2055684.pdf
Data publikacji:
2021
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
electron beam
heat treatment
polychlorinated biphenyls
radiation degradation
Opis:
An efficient method of burning polychlorinated biphenyls (PCBs) is often used to remove the environmental burden of PCBs. However, combustion produces toxic dioxins and furans (PCDD/F), so residents are increasingly rejecting this method. The heat treatment (HT) method does not burn PCBs but evaporates it from sediments. Even in this process, PCDD/Fs are formed to a lesser extent, which are destroyed by radiation processing (RP) following the HT. At the same time, the RP method degrades PCB congeners down to biphenyls, which decompose easily in the environment. A block assembly of a complex synergistic combination of equipment for methods of thermal (HT) and radiation (RP) destruction of PCBs in sediments is proposed. The efficacy of this complex was preliminarily determined at a level of 70-fold reduction in PCB concentration in sediments. To achieve a higher reduction factor in the concentration of PCBs, possible procedures for optimizing the settings of individual devices of this complex are presented.
Źródło:
Nukleonika; 2021, 66, 4; 207--211
0029-5922
1508-5791
Pojawia się w:
Nukleonika
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Remediation of polluted waters and wastewater by radiation processing
Autorzy:
Sampa, M. H. O.
Takács, E.
Gehringer, P.
Rela, P. R.
Ramirez, T.
Amro, H.
Trojanowicz, M.
Botelho, M. L.
Han, B.
Solpan, D.
Cooper, W. J.
Emmi, S. S.
Wojnárovits, L.
Powiązania:
https://bibliotekanauki.pl/articles/147644.pdf
Data publikacji:
2007
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
electron beam
wastewater treatment
pesticides
dyes
degradation
radiation technology
Opis:
Application of radiation processing for drinking water, wastewater, and groundwater treatment is a cost effective process which may insure adequate availability of that resource worldwide. This paper summarizes the results of a Coordinated Research Project (organized by the IAEA) with participants from 10 countries with the purpose of describing the degradation mechanism of organic impurities, and establishing optimal treatment conditions. Decoloration, disinfection, microbiological and toxicological experiments are also mentioned. These experiments led to pilot plants and also to a large scale industrial realization of radiation technology.
Źródło:
Nukleonika; 2007, 52, 4; 137-144
0029-5922
1508-5791
Pojawia się w:
Nukleonika
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Effect of electron radiation on sugar content in inverted liquid sugar
Autorzy:
Podadera, P.
Sabato, S. F.
Powiązania:
https://bibliotekanauki.pl/articles/148037.pdf
Data publikacji:
2009
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
electron beam
ionizing radiation
inverted liquid sugar
physicochemical properties
Opis:
Inverted liquid sugar is a mixture of sucrose, glucose and fructose, which shows its relevant characteristic on high sweetness power. Ionizing radiation has been applied to different kind of food and ingredients for different reasons, such as pathogens reduction, disinfestations, quarantine purposes, ripening delay among others. Radiation from an electron beam can be utilized as a technique to treat this ingredient because it can process a great volume of material per unit of time. The main goal of this paper was to verify the effect of radiation on the properties of inverted liquid sugar. This ingredient was irradiated in an electron accelerator (Radiation Dynamics) at a dose ranging from 5 to 50 kGy. Sucrose content measurements were reduced by 23% at 30 kGy when compared to control and the reduced sugar content increased around 11%. Density and moisture values were not affected by radiation. The total soluble solids (Brix degrees) rose in function of the absorbed dose.
Źródło:
Nukleonika; 2009, 54, 2; 85-87
0029-5922
1508-5791
Pojawia się w:
Nukleonika
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Radiation curing: coatings and composites
Autorzy:
Berejka, A. J.
Montoney, D.
Cleland, M. R.
Loiseau, L.
Powiązania:
https://bibliotekanauki.pl/articles/148453.pdf
Data publikacji:
2010
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
radiation curing
fiber composites
coatings
electron beam
X-ray
matrices
Opis:
The initial experiments conducted in the late 1960's at Radiation Dynamics, Inc. (now IBA Industrial, Inc.) showed that by removing the pigment from a radiation curable coating formulation, the same binder system could be used as a matrix system for electron beam (EB) cured fiber reinforced composites. Recently, the binder systems used for EB curable coatings have also been successfully used (without pigments) as the matrices for EB and X-ray cured fiber composites. Insights gained from the development of coatings were translated into desirable properties for matrix materials. For example, understanding the surface wetting characteristics of a coating facilitated the development of a matrix that would wet fibers; the development of coatings that would adhere to rigid substrates as metal while being bent, as for coil coatings, and which would exhibit impact resistance when cured on a metal also imparted impact resistance to cured composite materials. Thermal analyses conducted on the coating binder cured at low energies were consistent with analyses performed on thick cross-sections as used for matrices. The configuration of the final product then dictated the modality of curing, be it low-energy EB for coatings or higher energy EB or X-ray curing for composites. In industrial radiation chemistry, one deals with monomers and oligomers (similar to 102 and similar to 103 to 104 Daltons molecular weight, respectively). Thus, one can approach the development of coating binders or matrix systems as one would approach the synthesis of organic polymers. The desired final material is a fully cured and cross-linked polymer. In contrast, concepts involved in “formulating” are often derived from dealing with high molecular weight polymers (similar to 105 + Daltons) in which intense mechanical mixing is used to bring different ingredients together. When synthesizing a radiation curable coating or matrix system, greater attention is given to microphase compatibility as reflected in the microhomogeneity of the entire material.
Źródło:
Nukleonika; 2010, 55, 1; 97-106
0029-5922
1508-5791
Pojawia się w:
Nukleonika
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Chemia radiacyjna jako źródło unikatowych technologii syntezy i modyfikacji polimerów
Radiation chemistry as a source of unique technologies of synthesis and modification of polymers
Autorzy:
Głuszewski, W.
Powiązania:
https://bibliotekanauki.pl/articles/214135.pdf
Data publikacji:
2017
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
radioliza
polimery
promieniowanie jonizujące
wiązka elektronów
promieniowanie gamma
radiolysis
polymers
ionizing radiation
electron beam
gamma radiation
Opis:
Nawiązując do obchodzonej w tym roku 150. rocznicy urodzin Marii Skłodowskiej-Curie przypominam publikację, która dała początek radiacyjnej sterylizacji wyrobów medycznych jednorazowego użytku. W pracy tej uczona zwróciła również uwagę na heterogoniczny charakter oddziaływania promieniowania jonizującego na materię. Dopiero współcześnie posługując się modelem gniazd jonizacji wyjaśniono otrzymane eksperymentalnie krzywe radiacyjnej inaktywacji. Pierwotne procesy zachodzące w gniazdach jonizacji są nadal obiektem badań. W szczególności dyskutowane są mechanizmy zjawiska ochronnego obserwowanego w chemii radiacyjnej związków organicznych. Tłumaczone jest ono zarówno przeniesieniem wolnego rodnika jak i energii lub ładunku. Prowadzone przy nas badania skłaniają do stwierdzenia, że najbardziej prawdopodobny jest mechanizm wędrówki stanu wzbudzonego (energii). W ten sposób można wytłumaczyć raczej mało prawdopodobne spotkanie się dwóch makrorodników w procesie radiacyjnego sieciowania. Zwracam uwagę na rolę gniazd wielojonizacyjnych w radiolizie tworzyw polimerowych. Również w tym przypadku eksperymentalnie potwierdzono ochronne działanie związków aromatycznych. Benzen i jego pochodne oraz wyższe węglowodory aromatyczne mogą częściowo rozpraszać energię deponowaną w gniazdach o dużym LET (linear energy transfer). Warto podkreślić, że znakomita większość naturalnych i syntetycznych antyoksydantów to związki aromatyczne. Unikatowe cechy obróbki radiacyjnej wynikają ze stosunkowo prostego, wydajnego i łatwego w kontroli sposobu tworzenia wolnych rodników. Z tego powodu relatywnie kosztowne techniki radiacyjne znajdują liczne zastosowania.
Referring to the celebrated 150th anniversary of Marii Skłodowskiej-Curie birthday this year, I recall a publication that gave rise to the radiation sterilization of disposable medical devices. In this work, the scholar also drew attention to the heterogeneous nature of the impact of ionizing radiation on matter. Only now, using the model of the ionization spurs, the experiments have been performed on radiation inactivation curves. Primary processes occurring in ionization nests are still subject to investigation. Particularly discussed are the mechanisms of the protective phenomenon observed in the radiation chemistry of organic compounds. It is translated both by the transfer of free radicals and energy or by charge. The research conducted by us suggests that the most likely mechanism is the travel of the excited state (energy). In this way, it is possible to explain the rather unlikely encounter of two radicals in the radiation crosslinking process. I would like to point out the role of multi-ionization spurs in the radiolysis of polymer materials. Also in this case, the protective effect of the aromatic compounds was experimentally confirmed. Benzene and its derivatives and higher aromatic hydrocarbons may partially dissipate the energy deposited in large LET spurs. It is important to note that the vast majority of natural and synthetic antioxidants are aromatic compounds. The unique features of the radiation treatment result from a relatively simple, efficient and easy to control how to create free radicals. For this reason, relatively expensive radiation techniques find many applications.
Źródło:
Postępy Techniki Jądrowej; 2017, 4; 21-25
0551-6846
Pojawia się w:
Postępy Techniki Jądrowej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Od radiacyjnej sterylizacji do modyfikacji polimerów
From radiation sterilization to polymer modification
Autorzy:
Głuszewski, Wojciech
Powiązania:
https://bibliotekanauki.pl/articles/24201006.pdf
Data publikacji:
2023
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
radioliza
sterylizacja radiacyjna
chemia radiacyjna polimerów
wiązka elektronów
promieniowanie gamma
promieniowanie hamowania
radiolysis
radiation sterilization
radiation chemistry of polymers
electron beam
gamma radiation
braking radiation
Opis:
Zapotrzebowanie na tzw. zimne metody sterylizacji spowodowało, że opłacalne stało się projektowanie i budowa źródeł promieniowania jonizującego dużej mocy. Technologie radiacyjne pozwalają wyjaławiać wyroby w: dowolnej temperaturze, krótkim czasie oraz całej objętości (opakowaniu indywidulanym i zbiorczym). Działanie wiązki elektronów (EB), promieniowania gamma (γ) oraz hamowania nie pozostawia szkodliwych zanieczyszczeń. W artykule opisano, jak poszukiwania odpornych radiacyjnie tworzyw sztucznych dla zastosowań medycznych dały początek chemii radiacyjnej polimerów. Kolejnym przełomem było odkrycie zjawiska radiacyjnego sieciowania polietylenu, które współcześnie wykorzystuje się np. w: produkcji opon samochodowych, kabli elektrycznych i materiałów z tzw. pamięcią kształtu. Technologie radiacyjne rozwinęły się w kierunku bardzo zaawansowanych rozwiązań w zakresie naturalnych i syntetycznych polimerów. Przykładowo wymieniono badania nad: sieciowaniem materiałów komórkowych w produkcji wałków dylatacyjnych, modyfikację kompozytów polimerowych polipropylen(PP)/włókna konopne(HF) oraz PP/ścier drzewny.
The demand for the so-called cold sterilization methods made it profitable to design and build high-power ionizing radiation sources. Radiation technologies allow sterilization of products at: any temperature, short time and the entire volume (individual and collective packaging). The action of electron beam (EB), gamma radiation (γ) and bremsstrahlung no harmful contaminants. The article describes how the search for radiation-resistant plastics for medical applications gave rise to the radiation chemistry of polymers. Another breakthrough was the discovery of the phenomenon of radiation cross-linking of polyethylene, which is currently used, for example, in the production of car tires, electric cables and materials from the so-called shape memory. Radiation technologies have developed into very advanced solutions in the field of natural and synthetic polymers. Examples include research on: cross-linking of cellular materials in the production of expansion rolls, modification of polymer composites polypropylene (PP) / hemp fibers (HF) and PP / wood pulp.
Źródło:
Postępy Techniki Jądrowej; 2023, 3; 21--27
0551-6846
Pojawia się w:
Postępy Techniki Jądrowej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Electron beam technology for biogas and biofertilizer generation at municipal resource recovery facilities
Autorzy:
Chmielewski, Andrzej G.
Sudlitz, Marcin
Han, Bumsoo
Pillai, Suresh D.
Powiązania:
https://bibliotekanauki.pl/articles/2055685.pdf
Data publikacji:
2021
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
biogas
biofertilizer
cogeneration
electron beam
ionizing radiation
municipal wastewater plant sludge
phosphorus
resource recovery facility
sludge hygenization
Opis:
In the era of circular economies, municipal wastewater treatment plants (WWTPs) are viewed as resource recovery facilities. At the very minimum, the targeted resources are water, biogas, and phosphorus. However, municipal wastewater streams (sludge and effluent) need to be adequately treated to eliminate the potential for the transmission of microbial pathogens including protozoa, bacteria, and viruses. This paper presents the results from a study demonstrating the use of electron beam technology for sludge hygenization and enhanced methane (biogas) production using municipal wastewater samples. Cogeneration of heat for fertilizer drying and granulation and electricity for powering the electron beam system are also demonstrated.
Źródło:
Nukleonika; 2021, 66, 4; 213--219
0029-5922
1508-5791
Pojawia się w:
Nukleonika
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies