Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "electromyogram" wg kryterium: Temat


Wyświetlanie 1-3 z 3
Tytuł:
Influence of a hybrid manual - electric wheelchair propulsion system on the users muscular effort
Autorzy:
Wieczorek, Bartosz
Warguła, Łukasz
Kukla, Mateusz
Powiązania:
https://bibliotekanauki.pl/articles/2204666.pdf
Data publikacji:
2023
Wydawca:
Politechnika Białostocka. Oficyna Wydawnicza Politechniki Białostockiej
Tematy:
assistive technology
wheelchair
electromyogram
EMG
electric propulsion
control
Opis:
Self-propelled wheelchairs favour the rehabilitation process, forcing the user to be physically active. Unfortunately, in most cases, the manual propulsion is not adapted to the individual needs and physical capabilities of the user. This paper presents the results of operational tests of a wheelchair equipped with a hybrid propulsion system in which the muscle strength generated by the user is assisted by two independent electric motors. The research aimed to investigate the influence of the applied control algorithm and the assistance factor (W) on the value of the muscular effort (MA) while propelling the wheelchair with the use of push rims. A modified ARmedical AR-405 wheelchair equipped with two MagicPie 5 electric motors built into the wheelchair’s hubs with a power of 500 W was used in this research. The tests were carried out on a wheelchair test bench simulating the moment of resistance within the range of 8–11 Nm. Surface electromyography was employed for the measurement of MA, specifically, a four-channel Noraxon Mini DTS apparatus. The research was carried out on five patients from the group of C50 anthropometric dimensions. The effort was measured for four muscles: deltoid–anterior part, deltoid–posteriori part, and triceps brachii and extensor carpi radialis longus. The effectiveness of the hybrid propulsion system was observed based on the extensor carpi radialis longus muscle. In this case, for the standard wheelchair, the MA ranged from 93% to 123%. In contrast, for a wheelchair equipped with the hybrid propulsion system, at W = 70%, the MA was within the range of 43%–75%.
Źródło:
Acta Mechanica et Automatica; 2023, 17, 1; 28--34
1898-4088
2300-5319
Pojawia się w:
Acta Mechanica et Automatica
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Relevance of the EMG/Grip Relationship in Isometric Anisotonic Conditions
Autorzy:
Claudon, L.
Powiązania:
https://bibliotekanauki.pl/articles/91069.pdf
Data publikacji:
2003
Wydawca:
Centralny Instytut Ochrony Pracy
Tematy:
cumulative trauma disorders
upper limb
electromyogram (EMG)
force
isometric contraction
anisotonic contraction
schorzenia kończyn górnych
uraz kończyny górnej
kończyna górna
nadgarstek
ręka
Opis:
The aim of the present study was to develop a relationship to evaluate grip force using the electromyogram (EMG) in isometric anisotonic conditions. The EMGs of the flexor digitorum superficialis (FDS) and the extensor digitorum (ED) were recorded in 3 flexion-extension positions of the wrist (30° flexion, 30° extension, and 60° extension) associated with 3 positions of the forearm (70° pronation, prono-supination, and 70° supination). For each position, the participants had to follow linear ramp targets (2 rates of increase and decrease) displayed on an oscilloscope. The results show the best fit is a quadratic type force-EMG relationship. Some aspects such as the rate of force variation and the forearm and wrist positions are then discussed along with the limitations of the relationship.
Źródło:
International Journal of Occupational Safety and Ergonomics; 2003, 9, 2; 121-134
1080-3548
Pojawia się w:
International Journal of Occupational Safety and Ergonomics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The condition of the masticatory muscle group in the treatment of patients with reduced occlusion height
Stan grupy mięśni żucia podczas leczenia pacjentów z obniżoną wysokością zgryzu
Autorzy:
Grygus, Igor
Kostyshyn, Andrii
Ilnytska, Oleksandra
Ornat, Halyna
Powiązania:
https://bibliotekanauki.pl/articles/2056592.pdf
Data publikacji:
2022
Wydawca:
Akademia Bialska Nauk Stosowanych im. Jana Pawła II w Białej Podlaskiej
Tematy:
masticatory muscles
dental occlusion
electromyogram
masseter muscle
temporalis muscle
mięśnie żucia
zgryz
elektromiogram
mięsień żwacz
mięsień skroniowy
Opis:
Background. Dysfunction of the masticatory muscle group occurs in all types of masticatory system pathology. This is sometimes associated with changes in the musculoskeletal system, which are manifested in hypertension and hypotonia of the masticatory group of muscles, that cause a decrease in occlusal height. Material and methods. There were 123 patients enrolled, aged 35-54 years, who were made temporary fixed, fiberglass-reinforced plastic prostheses for the upper or lower jaw. There are several methods to improve the quality of orthopedic treatment with fixed bridges with reduced occlusal height, considering the condition of the masticatory muscles. One is the use of temporary fixed structures that provide a gradual increase in occlusal height, allow muscles to adapt to new conditions, and promote restructuring of “usual” myostatic reflexes. Results. To examine the effect of fixed structures on the m. masseter and m. temporalis, a technology for the manufacture of advanced temporary bridges was developed. This allowed us to study the process of masticatory muscle group adaptation to fixed orthopedic structures kept on the abutment teeth of patients without fractures for 6 months. In addition, it was possible to prepare the dental and maxillofacial system for permanent orthopedic treatment. Conclusions. Determination of the average total values of m. masseter and m. temporalis allowed us to establish the most effective intervention for patients with reduced occlusion height before, 1 month, and 6 months after temporary orthopedic treatment. There was a tendency for patients of all groups to approach the absolute symmetry.
Wprowadzenie. Dysfunkcja grupy mięśni żucia występuje we wszystkich rodzajach patologii układu żucia. Jest to niekiedy związane ze zmianami w układzie mięśniowo-szkieletowym, które objawiają się hipertensją i hipotonią grupy mięśni żucia, które powodują obniżenie wysokości zgryzu. Materiał i metody. W badaniu wzięło udział 123 pacjentów w wieku 35-54 lat, u których wykonano tymczasowe stałe protezy z tworzywa sztucznego wzmocnionego włóknem szklanym dla górnej lub dolnej szczęki. Istnieje kilka metod poprawy jakości leczenia ortopedycznego za pomocą mostów stałych o zredukowanej wysokości zgryzu, uwzględniających stan mięśni żucia. Jedną z nich jest zastosowanie tymczasowych konstrukcji stałych, które zapewniają stopniowe zwiększanie wysokości zgryzu, pozwalają mięśniom na adaptację do nowych warunków oraz sprzyjają przebudowie „zwykłych” odruchów miostatycznych. Wyniki. W celu zbadania wpływu stałych struktur na mięśnie żwaczy i mięśnie skroniowe, opracowano technologię wytwarzania zaawansowanych mostów tymczasowych. To pozwoliło na zbadanie procesu adaptacji grupy mięśni żucia do stałych struktur ortopedycznych pozostawionych na zębach filarowych u pacjentów bez pęknięć przez okres 6 miesięcy. Ponadto stało się możliwe przygotowanie układu stomatologicznego i szczękowo-twarzowego do stałego leczenia ortopedycznego. Wnioski. Wyznaczenie średnich wartości całkowitych mięśni żwaczy i mięśni skroniowych pozwoliło na ustalenie najkorzystniejszego zabiegu dla pacjentów z obniżoną wysokością zgryzu przed leczeniem, 1 miesiąc i 6 miesięcy po tymczasowym leczeniu ortopedycznym. U pacjentów wszystkich grup zaobserwowano tendencję do zbliżania się do symetrii bezwzględnej.
Źródło:
Health Problems of Civilization; 2022, 16, 2; 164-172
2353-6942
2354-0265
Pojawia się w:
Health Problems of Civilization
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-3 z 3

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies