Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "electrohysterography" wg kryterium: Temat


Wyświetlanie 1-4 z 4
Tytuł:
Analysis of electrical uterine contractile activity for prediction of preterm delivery
Autorzy:
Horoba, K.
Jezewski, J.
Matonia, A.
Wrobel, J.
Czabanski, R.
Jezewski, M.
Powiązania:
https://bibliotekanauki.pl/articles/333763.pdf
Data publikacji:
2015
Wydawca:
Uniwersytet Śląski. Wydział Informatyki i Nauki o Materiałach. Instytut Informatyki. Zakład Systemów Komputerowych
Tematy:
electrical uterine activity
electrohysterography
preterm delivery prediction
aktywność elektryczna macicy
elektrohisterografia
przewidywanie porodu przedwczesnego
Opis:
This study is aimed at evaluation of the capability to indicate the preterm delivery risk analysing the features extracted from signals of electrical uterine activity. Free access database was used with signals acquired in two groups of pregnant women who delivered at term and preterm. Signal features comprised classical time domain and spectral parameters of contractile activity, as well as the sample entropy. Their mean values were calculated over all contraction episodes detected in each record and their statistical significance for separating the two groups of recordings was provided. Influence of electrodes location, band-pass filter settings and gestation week was investigated. The obtained results showed that a spectral parameter – the median frequency was the most promising indicator of the preterm delivery risk.
Źródło:
Journal of Medical Informatics & Technologies; 2015, 24; 199-205
1642-6037
Pojawia się w:
Journal of Medical Informatics & Technologies
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Identification of a Nonlinear Association between Components of the Electrohysterographical Signal
Autorzy:
Radomski, D.
Małkiewicz, A.
Powiązania:
https://bibliotekanauki.pl/articles/226806.pdf
Data publikacji:
2010
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
bomeasurements
electrohysterography
nonlinear signal analysis
h2 index
nonlinear association
Opis:
Electrohysterography is a method for measuring of bioelectrical potentials generated by a contracting uterus. It is used for monitoring of uterine activities mainly during a pregnancy and for prediction of an upcoming pretermlabour. However, there is still unknown the best method of EHG analysis which gives clinically useful information about a uterine activity. To achieve this goal we propose to use information about nonlinear associations between EHG signals registered from an uterine fundus and an uterine cervix. The h² index was applied to identify these relationships. The obtained results reveal that there exists a nonlinear correlation between biopotentials generated from two parts of a pregnant uterus. Moreover, this correlation seems to be higher as a labour is upcoming. It suggests a possibility of using the h² index for prediction of an upcoming labour based on EHG signals.
Źródło:
International Journal of Electronics and Telecommunications; 2010, 56, 3; 287-290
2300-1933
Pojawia się w:
International Journal of Electronics and Telecommunications
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Method for Simultaneous Monitoring of Uterine Contractions and Abdominal Pushing in a Childbirth
Autorzy:
Radomski, Dariusz S.
Powiązania:
https://bibliotekanauki.pl/articles/27311956.pdf
Data publikacji:
2023
Wydawca:
Polska Akademia Nauk. Czasopisma i Monografie PAN
Tematy:
labour
electrohysterography
electromyography
instantaneous frequency
Opis:
Effective and safe labour requires good cooperation of all the physiological systems. A proper synchronization of uterine and abdominal muscles is necessary for labour progression. Therefore, a new method for simultaneous monitoring of uterine activities and parturient’s pushing efforts is presented. A high sampled, rectified electrohysterographic signal is divided into a low, uterine passband (0.1-3.00Hz) and a high, muscular (40-100Hz) one. The time-dependent mean frequencies arse estimated for each passband separately. At the moments of uterine contraction the time-dependent LOW mean frequency was locally increased. During parturient’s pushing effort the HIGH mean frequency was increased in the manner typical for the skeletal muscles. It seems that the proposed method would be less sensitive to a measuring noise than the previously published RMS based estimators. Moreover, the proposed method enables to monitor fatigue of a uterus or abdominal muscles during the prolonged 2nd stage of a labour. It can be helpful to make a decision of Caesarean section.
Źródło:
International Journal of Electronics and Telecommunications; 2023, 69, 2; 247--252
2300-1933
Pojawia się w:
International Journal of Electronics and Telecommunications
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The prognostic value of electrohysterography in prediction of premature labour
Autorzy:
Sikora, J.
Matonia, A.
Horoba, K.
Ziętek, J.
Jeżewski, J.
Powiązania:
https://bibliotekanauki.pl/articles/332889.pdf
Data publikacji:
2008
Wydawca:
Uniwersytet Śląski. Wydział Informatyki i Nauki o Materiałach. Instytut Informatyki. Zakład Systemów Komputerowych
Tematy:
elektrohisterografia
aktywność skurczowa macicy
electrohysterography
uterine activity
premature labour
Opis:
Premature birth is the leading cause of a neonatal death, so, it is extremely important to distinguish the pregnancy at risk of preterm threatening labour. The electrohysterography seems very promising as a method which enables noninvasive recording of readable bioelectrical signal of uterine muscle. The developed instrumentation enabled simultaneous recording of bioelectrical signals by means of electrodes attached to abdominal wall and mechanical activity of uterine muscle using fetal monitor. Material comprised 27 patients in physiological pregnancy (27 ÷ 40 week), and 21 patients (23 ÷ 36 week) with the symptoms of threatening premature labour. The obtained results showed that quantitative parameters of detected uterine contractions: amplitude and contraction area, obtained both for mechanical and electrical activity, were statistically significant (p < 0.05) to distinguish the patients at risk of premature labour. However, their reliability is low because they strongly depend on individual patient features. We consider the parameters characteristic for electrohysterogram exclusively e.g. contraction power and its median frequency as more useful (p < 0.05). Noninvasive electrohysterography ensures higher sensitivity and specificity for recognition of uterine contraction activity in comparison to classical mechanical method.
Źródło:
Journal of Medical Informatics & Technologies; 2008, 12; 71-76
1642-6037
Pojawia się w:
Journal of Medical Informatics & Technologies
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-4 z 4

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies