Wyświetlanie 1-5 z 5
Tytuł:
Self-absorption correction and efficiency calibration for radioactivity measurement of environmental samples by gamma-ray spectrometry
Autorzy:
Misiak, R.
Hajduk, R.
Stobiński, M.
Bartyzel, M.
Szarłowicz, K.
Kubica, B.
Powiązania:
https://bibliotekanauki.pl/articles/147063.pdf
Data publikacji:
2011
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
gamma spectrometry
efficiency calibration
self-absorption
environmental
Opis:
In this work empirical functions which relate the full-energy peak efficiency with sample height, energy, matrix composition and bulk density for voluminal samples in a cylindrical counting geometry were found. Accurate determination of the radioactivity of gamma-emitting radionuclides in environmental samples requires taking into account self-absorption. For the obtained self-absorption correction factor, a direct transmission method was chosen. Finally, this paper proposes a simple correlation between the self-absorption correction factor and the bulk density and height of the measured sample for a given energy.
Źródło:
Nukleonika; 2011, 56, 1; 23-28
0029-5922
1508-5791
Pojawia się w:
Nukleonika
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Automatyczne stanowisko pomiarowe do badań charakterystyk pracy plazmotronów łukowych
Automated measurement system for investigation of arc plasmatron characteristics
Autorzy:
Szałatkiewicz, J.
Kłoda, R.
Szewczyk, R.
Powiązania:
https://bibliotekanauki.pl/articles/276625.pdf
Data publikacji:
2012
Wydawca:
Sieć Badawcza Łukasiewicz - Przemysłowy Instytut Automatyki i Pomiarów
Tematy:
bilans energetyczny
pomiary
badania sprawności
cechowanie
plazmotron
automatyka
energia
plazma
chłodzenie
energy balance
measurements
efficiency measurement
calibration
plasmatron
automation
energy
plasma
cooling
Opis:
W artykule przedstawiono rozwiązanie stanowiska pomiarowego, umożliwiającego badanie najważniejszych parametrów pracy plazmotronów. Opracowanie stanowiska badawczego jest niezbędne w celu pozyskiwania powtarzalnych danych z pomiarów parametrów pracy plazmotronów, optymalizacji ich konstrukcji, określenia bilansu energetycznego oraz ich cechowania, certyfikacji. Plazmotrony zasilane są energią elektryczną i gazem roboczym, a do ich chłodzenia stosuje się wodę. Parametry robocze plazmotronu zależą od wielu zmiennych związanych z ich geometrią, mocą, przepływem gazu roboczego i chłodzeniem. Stąd, aby określić wpływ poszczególnych zmiennych i ich wzajemne relacje, niezbędnym jest wykonanie wielu równoległych pomiarów. Pomiary poszczególnych wielkości fizycznych realizowane są przy użyciu specjalistycznych, zespolonych przyrządów pomiarowych, umieszczonych w szafie pomiarowej. Pozwala to na integrację wszystkich pomiarów i ich digitalizację w jednym miejscu. Aby wykonać pomiary w trakcie pracy plazmotronu, szafę wyposażono w złącza umożliwiające wpięcie jej układów pomiarowych w obwody mierzonego urządzenia. Dobrano metody pomiarów: napięcia (V), prądu pracy (A), mocy pobieranej z sieci (W), przepływu gazu roboczego dm3/min, przepływu i temperatury wody chłodzącej niezależnie dla anody i katody (dm3/s). Mierzone parametry pracy plazmotronu są jednocześnie zapisywane co 1 s i wizualizowane w programie w środowisku LabView, na ekranie komputera PC. System pomiarowy, na podstawie wielkości mierzonych, automatycznie wylicza bilans energetyczny, sprawność cieplną plazmotronu oraz inne istotne parametry eksploatacyjne urządzenia.
The paper, presents automated measurement system for investigation of key arc plasmatrons parameters. Automated measurement system allows to simultaneously and broadly investigate plasmatron work parameters. Collection of plasmatron operational data is required for optimization of theirs construction, efficiency determination, energy balance calculation, and calibration. Plasmatrons are powered with electrical energy and work gas, theirs cooling is carried out by water circuit. Work parameters of plasmatrons are depending on many factors, theirs geometry, power, gas flow and cooling. So to investigate influence of each factor, it is necessary to perform many simultaneous measurements. Each measurement of physical value is performed by specialist combined sensor, located in measurement cabinet. Such approach allows for integration of all the measurements and digitalization of collected data in one place. Measuremetns have to be performed during normal operation of plasmotron, to allow such action, the measurement cabinet is equipped with connections allowing to hook it up to the plasmatron circuits. Developed automated measurement system carries out key measurements of plasmatron parameters: voltage, amperage, power, flow of plasma gas, flow and temperature of cooling fluid for anode, and cathode. Measured values, are simultaneously stored each second, and visualized in application software developed in LabView, on PC. Based on collected data the software of automated measurement system calculates energy balance, efficiency, and other important parameters of plasmatorn during its exploitation.
Źródło:
Pomiary Automatyka Robotyka; 2012, 16, 2; 546-551
1427-9126
Pojawia się w:
Pomiary Automatyka Robotyka
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Precise determination of HPGe detector efficiency for gamma spectrometry measurements of environmental samples with variable geometry and density
Autorzy:
Barrera, M.
Casas-Ruiz, M.
Alonso, J. J.
Vidal, J.
Powiązania:
https://bibliotekanauki.pl/articles/146350.pdf
Data publikacji:
2017
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
efficiency calibration
environmental radioactivity
gamma spectrometry
geometric dependence of the efficiency
self-attenuation corrections
Opis:
A methodology to determine the full energy peak efficiency (FEPE) for precise gamma spectrometry measurements of environmental samples with high-purity germanium (HPGe) detector, valid when this efficiency depends on the energy of the radiation E, the height of the cylindrical sample H, and its density ρ is introduced. The methodology consists of an initial calibration as a function of E and H and the application of a self-attenuation factor, depending on the density of the sample ρ, in order to correct for the different attenuation of the generic sample in relation to the measured standard. The obtained efficiency can be used in the whole range of interest studied, E = 120–2000 keV, H = 1–5 cm, and ρ = 0.8–1.7 g/cm3, being its uncertainty below 5%. The efficiency has been checked by the measurement of standards, resulting in a good agreement between experimental and expected activities. The described methodology can be extended to similar situations when samples show geometric and compaction differences.
Źródło:
Nukleonika; 2017, 62, 1; 47-59
0029-5922
1508-5791
Pojawia się w:
Nukleonika
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Traceability of gas flow measurements in complex distribution systems - uncertainty approach vs error approach
Autorzy:
Džemić, Zijad
Širok, Brane
Drnovšek, Janko
Powiązania:
https://bibliotekanauki.pl/articles/220509.pdf
Data publikacji:
2019
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
calibration
energy efficiency
error analyses
measurement uncertainty
traceability
Opis:
The objective of the paper is to analyse traceability issues in real-life gas flow measurements in complex distribution systems. The initial aim is to provide complete and traceable measurement results and calibration certificates of gas-flow meters, which correspond to specific installation conditions. Extensive work has been done to enable a more credible decision on how to deal in particular situations with the measurement uncertainty which is always subject of a flow meter’s calibration as a quantitative parameter value obtained in laboratory, and with the qualitative statement about the error of an outdoor meter. The laboratory simulation of a complex, real-life distributed system has been designed to achieve the initial aim. As an extension of standardized procedures that refer to the laboratory conditions, the proposed methods introduce additional “installation-specific” error sources. These sources could be either corrected (if identified) or considered as an additional “installation-specific” uncertainty contribution otherwise. The analysis and the results of the experimental work will contribute to more precise and accurate measurement results, thus assuring proper measurements with a known/estimated uncertainty for a specific gas flow installation. Also, the analysis will improve the existing normative documents by here presented findings, as well as fair trade in one of the most important and growing energy consumption areas regarding the legal metrology aspects. These facts will enable comparing the entire quantity of gas at the input of a complex distributed system with the cumulative sum of all individual gas meters in a specific installation.
Źródło:
Metrology and Measurement Systems; 2019, 26, 2; 419-429
0860-8229
Pojawia się w:
Metrology and Measurement Systems
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Developing calibration estimators for population mean using robust measures of dispersion under stratified random sampling
Autorzy:
Audu, Ahmed
Singh, Rajesh
Khare, Supriya
Powiązania:
https://bibliotekanauki.pl/articles/1054567.pdf
Data publikacji:
2021-06-04
Wydawca:
Główny Urząd Statystyczny
Tematy:
calibration
outliers
percentage relative efficiency (PRE)
stratified sampling
Opis:
In this paper, two modified, design-based calibration ratio-type estimators are presented. The suggested estimators were developed under stratified random sampling using information on an auxiliary variable in the form of robust statistical measures, including Gini’s mean difference, Downton’s method and probability weighted moments. The properties (biases and MSEs) of the proposed estimators are studied up to the terms of firstorder approximation by means of Taylor’s Series approximation. The theoretical results were supported by a simulation study conducted on four bivariate populations and generated using normal, chi-square, exponential and gamma populations. The results of the study indicate that the proposed calibration scheme is more precise than any of the others considered in this paper.
Źródło:
Statistics in Transition new series; 2021, 22, 2; 125-142
1234-7655
Pojawia się w:
Statistics in Transition new series
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-5 z 5

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies