Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "double cage induction motor" wg kryterium: Temat


Wyświetlanie 1-2 z 2
Tytuł:
Stator current spectrum analysis of a double cage induction motor with rotor asymmetry
Autorzy:
Tulicki, Jarosław
Sobczyk, Tadeusz Jan
Sułowicz, Maciej
Powiązania:
https://bibliotekanauki.pl/articles/24202742.pdf
Data publikacji:
2023
Wydawca:
Polska Akademia Nauk. Czasopisma i Monografie PAN
Tematy:
cage asymmetry
double cage induction motor
harmonic balance method
steady-state analysis
stator current Fourier spectra
Opis:
This study presents a method to directly calculate the stator current Fourier spectra in double-cage induction motors to diagnose faults in rotor cages. A circuit model is developed for this purpose, allowing the modelling of any asymmetry in the outer and inner rotor cages. The model extends the conventional model of a cage motor by considering the higher space harmonics generated by the stator windings. The asymmetry of the cages is modelled by growing the resistance of any of the rotor bars. This results in various model equations, to be solved by looking for diagnostic signals. Motor current signature analysis is typically used to diagnose cage motors based on the Fourier spectra of the stator currents during steady-state operation. This study determines these spectra for double cage motors using the harmonic balance method, omitting the transient calculations. The calculation results confirmed the sensitivity of the stator current Fourier spectra as a diagnostic signal to distinguish faults in the outer and inner cages.
Źródło:
Archives of Electrical Engineering; 2023, 72, 2; 357--371
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wykrywanie niesymetrii klatki rozruchowej silnika indukcyjnego dwuklatkowego w stanie ustalonym
Detection of asymmetry of starting cage in a double cage induction motor in steady state
Autorzy:
Tulicki, J.
Sułowicz, M.
Powiązania:
https://bibliotekanauki.pl/articles/1197467.pdf
Data publikacji:
2018
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Napędów i Maszyn Elektrycznych Komel
Tematy:
silnik indukcyjny dwuklatkowy
asymetria klatki wirnika
diagnostyka uszkodzeń
model polowy
double cage induction motor
rotor cage asymmetry
fault diagnosis
finite element mode
Opis:
Detecting internal damages of an electrical rotor of double cage induction motors is a difficult and multistage task. Particularly important, in the case of determining the scope of repair of the rotor, is the information that would allow one to determine which cage of the rotor has been damaged. The purpose of the article is to indicate an effective method of distinguishing failures of the starting cage from a working cage, with the resistive asymmetries of bars or rings. In the article the authors considered a motor with two most common rotor designs, i.e. with the common and separate rings the circuits of cages, respectively. Diagnostic analysis was performed for a double cage low-power induction motor prototype for which stator current signals were recorded during the measurements in the laboratory.The results of the measurements were compared against the calculations obtained using the finite element model (FEM).
Wykrywanie uszkodzeń wewnętrznych wirnika o charakterze elektrycznym silników indukcyjnych dwuklatkowych jest zadaniem trudnym i wieloetapowym. Szczególnie ważna, w przypadku określenia zakresu remontu wirnika jest informacja, która klatka uległa uszkodzeniu. Celem niniejszego artykułu jest wskazanie skutecznej metody rozróżnienia uszkodzeń obwodów klatki rozruchowej od klatki pracy w stanie ustalonym z niesymetriami rezystancyjnymi prętów lub pierścieni zwierających. W pracy rozważono silnik z dwoma najczęściej występującymi konstrukcjami wirnika ze wspólnym i osobnymi pierścieniami zwierającymi obwody klatek. Przeprowadzono analizy diagnostyczne dla prototypowego silnika indukcyjnego dwuklatkowego małej mocy, w przypadku którego zarejestrowano sygnały prądów stojana podczas pomiarów w laboratorium. Wyniki pomiarów porównano z obliczeniami uzyskanymi z modelu polowego silnika indukcyjnego dwuklatkowego z niesymetrycznymi obwodami wirnika.
Źródło:
Maszyny Elektryczne: zeszyty problemowe; 2018, 3, 119; 131-137
0239-3646
2084-5618
Pojawia się w:
Maszyny Elektryczne: zeszyty problemowe
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-2 z 2

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies