Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "dose equivalent" wg kryterium: Temat


Wyświetlanie 1-12 z 12
Tytuł:
A study of the photoneutron dose equivalent resulting from a Saturne 20 medical linac using Monte Carlo method
Autorzy:
Hashemi, F.
Hashemi-Malayeri, B.
Raisali, G.
Shokrani, P.
Sharafi, A.
Powiązania:
https://bibliotekanauki.pl/articles/148191.pdf
Data publikacji:
2007
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
photoneutron
linac
Monte Carlo method
MCNP4C
dose equivalent
Opis:
High energy linacs have several advantages including lower skin dose and higher dose rate at deep sighted tumors. But, at higher energies photonuclear reactions produce neutron contamination. Photoneutron contamination has been investigated from the early days of modern linacs. However, more studies have become possible using Monte Carlo codes developed in recent years. The aim of this study was to investigate the photoneutron spectrum and dose equivalent produced by an 18 MV Saturne linac at different points of a treatment room and its maze. The MCNP4C code was used to simulate the transport of photoneutrons produced by a typical 18 MV Saturne linac. The treatment room of a radiotherapy facility in which a Saturne 20 linac is installed was modeled. Neutron dose equivalent was calculated and its variations at various distances from the center of the X-ray beam was studied. It was noted that by increasing the distance from the center of the beam, fast neutrons decrease rapidly, but thermal neutrons do not change significantly. In addition, the photoneutron dose equivalent was lower for smaller fields. The fast photoneutrons were not recorded in the maze. It can be concluded that the fast photoneutrons are highly attenuated by concrete barrier, while the slow photoneutrons are increased. In addition, increasing the X-ray field size increases the photoneutron dose equivalent around the treatment room and maze. It seems that the walls play an effective role in increasing the photoneutron dose equivalent.
Źródło:
Nukleonika; 2007, 52, 1; 39-43
0029-5922
1508-5791
Pojawia się w:
Nukleonika
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Luminescence dating of Quaternary sediments – some practical aspects
Autorzy:
Moska, Piotr
Powiązania:
https://bibliotekanauki.pl/articles/2025218.pdf
Data publikacji:
2019
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
luminescence dating
dose rate
equivalent dose
Opis:
Luminescence dating is based mainly on the dosimetric properties of quartz and feldspar. These minerals are among the most popular found on Earth, resulting in the possibility of using luminescence methods in practically any environment. Currently, quartz remains the best recognized mineral in terms of dosimetric properties, particularly with regards to results obtained for quartz grains, which are regarded as being the most reliable in luminescence dating. Supporters of luminescence methods are constantly growing, however, these groups do not always have sufficient knowledge to avoid even the most basic of issues that may be encountered overall – from the process of sampling through to the awareness of what a single luminescence result represents. The present paper provides an overview of several practical aspects of luminescence dating such as correct sampling procedures and all necessary information regarding the calculation of the dose rate and equivalent dose with particular reference to potential problems that occur when the age of the sample is being determined. All these aspects are crucial for obtaining a reliable dating result, on the other hand, they remain a potential source of uncertainty.
Źródło:
Studia Quaternaria; 2019, 36; 161-169
1641-5558
2300-0384
Pojawia się w:
Studia Quaternaria
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wpływ algorytmów obliczających rozkłady dawek w radioterapii na prawdopodobieństwo miejscowego wyleczenia
The influence of dose calculation algorithms on TCP in radiotherapy
Autorzy:
Ślosarek, Krzysztof
Stąpór-Fudzińska, Małgorzata
Osewski, Wojciech
Szlag, Marta
Powiązania:
https://bibliotekanauki.pl/articles/985960.pdf
Data publikacji:
2019
Wydawca:
Indygo Zahir Media
Tematy:
algorytm
TCP/NTCP
dawka równoważna
algorithm
equivalent dose
Opis:
W planowaniu rozkładu dawki w radioterapii stosowane są różne algorytmy obliczające. Najprostsze z nich, stosowane od wielu lat, dają dobrą zgodność: obliczenia – pomiar, ale tylko w przypadku najprostszych modeli, np. w ośrodku o jednorodnej gęstości. Wraz z rozwojem technik obliczeniowych pojawiły się algorytmy, które uwzględniały coraz więcej zjawisk fizycznych oddziaływania promieniowania z materią. Różnice pomiędzy dawkami obliczonymi i zmierzonymi, dla bardzo wyrafinowanych sytuacji klinicznych, są coraz mniejsze, mieszczą się granicach niepewności metody. Czy zatem dokładność obliczeń może mieć wpływ na wyniki radioterapii? Aby odpowiedzieć na to pytanie, należy rozkłady dawek fizycznych połączyć z dawkami biologicznie równoważnymi i obliczyć prawdopodobieństwo miejscowego wyleczenia. Skorzystano z modelu liniowo-kwadratowego oraz modelu Poissona. Wykonane obliczenia wskazują, że istnieje wpływ algorytmu obliczającego na prawdopodobieństwo miejscowego wyleczenia. Jednak jest on uzależniony od lokalizacji guza nowotworowego. W sytuacji, kiedy różnice gęstości w napromienianej objętości nie są zbyt duże – najprostsze i najbardziej zaawansowane modele wyliczają podobne dawki, czyli nie wykazują wpływu na prawdopodobieństwo miejscowego wyleczenia. Jednak w sytuacji dużych różnic w gęstościach, prostsze modele mogą znacznie zafałszować rozkłady dawek, co przekłada się na TCP.
In the radiotherapy treatment planning, different calculation algorithms are used. Can the accuracy of calculations affect the results of radiotherapy? Physical dose distributions should be combined with biologically equivalent doses and calculated the local control probability. The Linear-Quadratic model and the Poisson model were used. The dose calculations indicates that there is an effect of a computing algorithm on the local control probability. However, it depends on the location of the tumor. In the case of large differences in densities, more simple models can significantly distort dose distribution, which affects the TCP.
Źródło:
Inżynier i Fizyk Medyczny; 2019, 8, 1; 27-32
2300-1410
Pojawia się w:
Inżynier i Fizyk Medyczny
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
214Bi/214Pb radioactivity ratio three-year monitoring in rainwater in Prague
Autorzy:
Ambrosino, Fabrizio
Thinová, Lenka
Hýža, Miroslav
Sabbarese, Carlo
Powiązania:
https://bibliotekanauki.pl/articles/148739.pdf
Data publikacji:
2020
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
214Bi/214Pb gamma-ray ratio
ambient dose equivalent rate
hybrid method
rainfall
time-series analysis
Opis:
Continuous monitoring of natural gamma radiation in air has been carried out, during December 2014 – January 2018, with 1-min cyclic measurement in Prague, Czech Republic using a NaI(Tl) probe. The 214Bi/214Pb ratio as a tracer in rainwater has been investigated to study its variations related to both the ambient dose equivalent rate per hour and the amount of rainfall. A hybrid methodology for time series analysis, composed of the aggregation of two signal decomposition methods (multiple linear regression and empirical mode decomposition) and one forecasting method (support vector regression), has been applied to identify the anomalies in the studied signals in order to better find correlations among them. The results show a strong correlation between the ambient dose equivalent rate and the 214Bi/214Pb ratio values and between both these signals and rainfall amount≥5 mm/h. Furthermore, the considered descendants of radon are mainly responsible for the overall ambient dose equivalent rate.
Źródło:
Nukleonika; 2020, 65, 2; 115-119
0029-5922
1508-5791
Pojawia się w:
Nukleonika
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Exposure to ionizing radiation by service personnel working with cyclotrons used to produce radiopharmaceuticals in PET diagnostics
Autorzy:
Biegała, Michał
Jakubowska, Teresa
Wrzesień, Małgorzata
Albiniak, Łukasz
Powiązania:
https://bibliotekanauki.pl/articles/2152980.pdf
Data publikacji:
2022
Wydawca:
Instytut Medycyny Pracy im. prof. dra Jerzego Nofera w Łodzi
Tematy:
nuclear medicine
PET
equivalent dose
service
radiological protection
cyclotron
Opis:
Objectives While working with cyclotrons used for the production of radiopharmaceuticals, workers can experience significant exposure to the adverse effects of ionizing radiation. The aim of this paper was to determine the typical level of such exposure received by such personnel while servicing cyclotrons. Material and Methods Exposure was assessed using TLD detectors placed in an anthropomorphic phantom, as well as dose meter to determine whole body and eye lens exposure. The phantom was placed in locations receiving the greatest exposure to ionizing radiation during service activities. The time spent by employees during servicing was assessed based on routine visits by service technicians. The obtained results were compared with readings of detectors worn by employees during service activities. Results The highest equivalent doses in the thoracic area were found to be received by the lungs (211.16 μSv/year). In the head and neck area, the highest dose was measured in the eye lens (3410 μSv/year). The effective dose for the whole body was found to be 1154.4 μSv/year, based on the phantom, and 149 μSv per service visit (1192 μSv/year), based on the dose meters carried by the workers. Conclusions Service workers are exposed to significant doses of ionizing radiation, representing a clear radiological protection issue. To reduce exposure to eye lenses, it is recommended to use protective goggles when working with highly-radioactive elements.
Źródło:
International Journal of Occupational Medicine and Environmental Health; 2022, 35, 6; 753-760
1232-1087
1896-494X
Pojawia się w:
International Journal of Occupational Medicine and Environmental Health
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Spatial distribution of equivalent gamma dose rate in the vicinity of mine water sedimentation ponds in Upper Silesian Coal Basin
Autorzy:
Śleziak, M.
Duliński, M.
Powiązania:
https://bibliotekanauki.pl/articles/146886.pdf
Data publikacji:
2012
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
spatial equivalent gamma dose rate
natural radioactivity
sedimentation pond
Opis:
In the Upper Silesian Coal Basin highly mineralized mine waters are pumped into numerous sedimentary ponds before discharge to the Vistula river. They contain elevated concentrations of natural radionuclides (mainly radium). In ponds, some fraction of radionuclides is removed from the water column by adsorption on settling particles, precipitation or co-precipitation, thus increasing radioactivity levels in the deposits. Due to fluctuations of water level and wind action, fine fraction of the deposited material can be distributed in the vicinity of ponds. Three ponds have been selected for survey of the gamma equivalent dose: Brzeszcze, Kaniów, and Rontok Duży. The lowest dose rates, below 0.33 miSv/h, were detected in the area of the Brzeszcze pond. The highest values were measured over the sediments of the Kaniow pond (8.37 miSv/h), being 30 times higher than the dose rate received by population in Poland from natural sources.
Źródło:
Nukleonika; 2012, 57, 4; 597-599
0029-5922
1508-5791
Pojawia się w:
Nukleonika
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Assessment of individual dose equivalents Hp(0.07) of medical staff occupationally exposed to ionizing radiation in 2012
Ocena wielkości indywidualnych równoważników dawek Hp(0,07) u pracowników medycznych zawodowo narażonych na działanie promieniowania jonizującego w 2012 roku
Autorzy:
Papierz, Sylwia
Kamiński, Zbigniew
Adamowicz, Małgorzata
Zmyślony, Marek
Powiązania:
https://bibliotekanauki.pl/articles/2166245.pdf
Data publikacji:
2014-10-27
Wydawca:
Instytut Medycyny Pracy im. prof. dra Jerzego Nofera w Łodzi
Tematy:
promieniowanie X
indywidualny równoważnik dawki
dozymetr termoluminescencyjny
radiologia interwencyjna
dozymetria pierścionkowa
X-rays
personal dose equivalent
thermoluminescence detector
interventional radiology
ring dosimetry
Opis:
Background: The paper presents the Nofer Institutes of Occupational Medicine in Łódź's results of the assessment of individual dose equivalents Hp(0.07) of medical staff exposed to X-rays in Poland in 2012. In addition, the collected data was analysed in terms of types of medical units performing medical procedures and the categorization of personnel. Material and Methods: Dosimetric service was provided for medical staff of interventional radiology departments occupationally exposed to ionizing radiation in terms of individual dose equivalents Hp(0.07). In 2012, personal dosimetry Hp(0.07) determinations were performed by the Nofer Institute of Occupational Medicine in Łódź and covered 2044 employees from 174 health facilities. The determinations were performed using thermoluminescence dosimetry according to the procedure accredited by the Polish Centre for Accreditation (document number AB 327). The measurements were performed using ring-dosimeters in the periods of 1 or 2 months. Results: Mean annual individual dose equivalent Hp(0.07) in 2012 was equal to 3.3 mSv (annual limit for Hp(0.07) is 500 mSv). The average value of annual individual dose equivalent Hp(0.07) decreased comparing to the previous year. In 2012, no single case of exceeding the annual limit for Hp(0.07) was reported. Data stored in the file indicates that more than 96% of all of the annual doses did not exceed the level of 10 mSv. Conclusions: The analysis of data on occupational exposure to ionizing radiation confirms a stable level of exposure and satisfactory radiological protection in interventional radiology facilities monitored by the Nofer Institute of Occupational Medicine in Łódź in Poland in 2012. Med Pr 2014;65(2):167–171
Wstęp: W prezentowanej pracy przedstawiono wyniki oceny indywidualnych równoważników dawek Hp(0,07) promieniowania jonizującego u personelu medycznego zakładów radiologii interwencyjnej zawodowo narażonego na promieniowanie rentgenowskie w Polsce w 2012 r. według danych Zakładu Ochrony Radiologicznej Instytutu Medycyny Pracy im. prof. J. Nofera w Łodzi. Ponadto dane zgromadzone w bazie szczegółowo analizowano w zależności od typu oddziału medycznego oraz personelu medycznego. Materiał i metody: Pomiary dozymetryczne dla pracowników zakładów radiologii interwencyjnej zawodowo narażonych na promieniowanie jonizujące prowadzono na podstawie pomiarów indywidualnego równoważnika dawki Hp(0,07). W 2012 r. Instytut Medycyny Pracy im. prof. J. Nofera w Łodzi objął pomiarami 2044 osoby zatrudnione w 174 placówkach służby zdrowia. Badania wykonano techniką dozymetrii termoluminescencyjnej zgodnie z procedurą badawczą (zakres akredytacji AB 327) akredytowaną przez Polskie Centrum Akredytacyjne. Pomiary indywidualnego równoważnika dawki Hp(0,07) wykonywane są w sposób ciągły w cyklach 1-miesięcznych lub 2-miesięcznych. Wyniki: Średni roczny indywidualny równoważnik dawki Hp(0,07) w 2012 r. wynosił 3,3 mSv (roczny limit dla dawki Hp(0,07) wynosi 500 mSv). Średnia wartość rocznego indywidualnego równoważnika dawki Hp(0,07) zmalała w porównaniu z rokiem poprzednim. W 2012 r. nie odnotowano ani jednego przypadku przekroczenia rocznego limitu dla Hp(0,07). Dane zgromadzone w bazie wskazują, że ponad 96% wszystkich rocznych dawek Hp(0,07) nie przekroczyło poziomu 10 mSv. Wnioski: Analiza zebranych w bazie Instytutu Medycyny Pracy w Łodzi wyników średnich rocznych dawek Hp(0,07) w 2012 r. potwierdza ustabilizowany poziom narażenia zawodowego powodowanego promieniowaniem X w zakładach radiologii interwencyjnej. Med. Pr. 2014;65(2):167–171
Źródło:
Medycyna Pracy; 2014, 65, 2; 167-171
0465-5893
2353-1339
Pojawia się w:
Medycyna Pracy
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Occupational exposure to radon for underground tourist routes in Poland: Doses to lung and the risk of developing lung cancer
Autorzy:
Walczak, Katarzyna
Olszewski, Jerzy
Politański, Piotr
Zmyślony, Marek
Powiązania:
https://bibliotekanauki.pl/articles/2161885.pdf
Data publikacji:
2017-07-14
Wydawca:
Instytut Medycyny Pracy im. prof. dra Jerzego Nofera w Łodzi
Tematy:
occupational exposure
radon
effective dose
relative risk of lung cancer
equivalent dose to lung
underground tourist routes
Opis:
Objectives Radon concentrations for 31 Polish underground tourist routes were analyzed. The equivalent dose to the lung, the effective dose and the relative risk were calculated for employees of the analyzed routes on the grounds of information on radon concentrations, work time, etc. Material and Methods The relative risk for lung cancers was calculated using the Biological Effects of Ionizing Radiation (BEIR) VI Committee model. Equivalent doses to the lungs of workers were determined using the coefficients calculated by the Kendall and Smith. The conversion coefficient proposed by the International Atomic Energy Agency (IAEA) in the report No. 33 was used for estimating the effective doses. Results In 13 routes, the effective dose was found to be above 1 mSv/year, and in 3 routes, it exceeded 6 mSv/year. For 5 routes, the equivalent dose to lungs was higher than 100 mSv/year, and in 1 case it was as high as 490 mSv/year. In 22.6% of underground workplaces the risk of developing lung cancer among employees was about 2 times higher than that for the general population, and for 1 tourist route it was about 5 times higher. The geometric mean of the relative risk of lung cancer for all workers of underground tourist routes was 1.73 (95% confidence interval (CI): 1.6–1.87). Routes were divided into: caves, mines, post-military underground constructions and urban underground constructions. Conclusions The difference between levels of the relative risk of developing lung cancer for all types of underground tourist routes was not found to be significant. If we include the professional group of the employees of underground tourist routes into the group of occupational exposure, the number of persons who are included in the Category A due to occupational exposure may increase by about 3/4. The professional group of the employees of underground tourist routes should be monitored for their exposure to radon. Int J Occup Med Environ Health 2017;30(5):687–694
Źródło:
International Journal of Occupational Medicine and Environmental Health; 2017, 30, 5; 687-694
1232-1087
1896-494X
Pojawia się w:
International Journal of Occupational Medicine and Environmental Health
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Pomiar indywidualnego równoważnika dawki promieniowania X i gamma za pomocą dozymetru pierścionkowego – wyniki porównań międzylaboratoryjnych
Measurement of personal dose equivalent of X and gamma radiation by ring dosimeter: Results of intercomparison measurements
Autorzy:
Adamowicz, Małgorzata
Papierz, Sylwia
Kacprzyk, Janusz
Kamiński, Zbigniew
Zmyślony, Marek
Powiązania:
https://bibliotekanauki.pl/articles/2166303.pdf
Data publikacji:
2014-11-05
Wydawca:
Instytut Medycyny Pracy im. prof. dra Jerzego Nofera w Łodzi
Tematy:
porównania międzylaboratoryjne
promieniowanie rentgenowskie i gamma
indywidualny równoważnik dawki
dozymetr pierścionkowy
detektor termoluminescencyjny
interlaboratory comparisons
X-ray and gamma radiation
personal dose equivalent
ring dosimeter
thermoluminescence detectors
Opis:
Wstęp: Celem pracy było potwierdzenie, na podstawie wyników porównań międzylaboratoryjnych dla dozymetrów pierścionkowych, że stosowana metoda badawcza jest odpowiednia do pomiaru indywidualnego równoważnika dawki HP(0,07). Ponadto w pracy przedstawiono procedury kalibracyjne stosowane podczas walidacji metody badawczej przed wdrożeniem do rutynowych pomiarów związanych z oceną narażenia pracowników na działanie promieniowania X i γ. Materiał i metody: Przedmiotem porównań międzylaboratoryjnych były dozymetry pierścionkowe wykonane z elastycznego tworzywa o standardowej średnicy 20 mm i z umieszczonymi wewnątrz dwoma detektorami termoluminescencyjnymi (TL) typu MTS-N - po naeksponowaniu u organizatora porównań odczytywano je za pomocą nowego, manualnego czytnika detektorów TL (prod. FIMEL, Francja). Wszystkie ekspozycje dozymetrów, przeprowadzone dla celów walidacyjnych ww. czytnika, wykonano we wzorcowych wiązkach promieniowania X i γ z zastosowaniem fantomu prętowego ISO. Metodyka wykonanych ekspozycji była odpowiednia do potrzeb pracowni oraz zgodna z metodami stosowanymi przez Europejskę Grupę ds. Dozymetrii Promieniowania (European Radiation Dosimetry Group - EURADOS) - organizatora porównań międzylaboratoryjnych o europejskim zasięgu w zakresie dozymetrii indywidualnej. Wyniki: Wykonane charakterystyki - energetyczna, dawkowa i kątowa dozymetru pierścionkowego - umożliwiły opracowanie wzoru dotyczącego oszacowania indywidualnego równoważnika dawki HP(0,07) oraz poddania go testowi weryfikacyjnemu. Stwierdzono zadowalający wynik testu oceny wielkości HP(0,07) i tym samym potwierdzono gotowość wdrożenia czytnika termoluminescencyjnego do stosowanej metody badawczej oraz uczestniczenia w porównaniach międzylaboratoryjnych. Wnioski: Laboratorium - zgodnie z wymaganiami Polskiego Centrum Akredytacji - uczestniczyło w porównaniach międzylaboratoryjnych (organizowanych przez grupę EURADOS) w zakresie pomiaru dawki równoważnej na ręce promieniowania jonizującego X i γ. Wynik porównania był pozytywny, a jego przedmiotem były dozymetry pierścionkowe. Potwierdzono tym samym prawidłowość realizowanej procedury badawczej. Med. Pr. 2013;64(5):631–637
Background: The aim of the study was to present the results of the interlaboratory comparisons for ring dosimeters and to confirm that the applied method is suitable for measuring the personal dose equivalent HP(0.07). In addition, calibration procedures used in dosimetric measurements in persons occupationally exposed to ionizing photon radiation X and γ were presented. Materials and Methods: Ring dosimeters made of flexible plastics with the diameter of approximately 20 mm, equipped with two thermoluminescence (TL) detectors type MTS-N, were the subject of interlaboratory comparisons. Irradiated detectors were red out using a new manual TLD's reader (FIMEL, France). All TLD exposures were done for validation of TLD readers and were performed using the reference X-ray and γ beams with the ISO rod phantom. The methodology of performed exposures corresponded with the methods applied by the European Radiation Dosimetry Group (EURADOS), the European organizer of interlaboratory comparisons. Results: The energy, dose and angular characteristics of the ring dosimeter allowed to elaborate the formula for estimating and verifying the personal dose equivalent HP(0.07). The test was performed to check and confirm the correctness of the estimated characteristics. The test results were satisfactory, and thus the readiness to implement TLD reader in the used method and to participate in interlaboratory comparisons was confirmed. Conclusions: According to the requirements of the Polish Centre for Accreditation, the laboratory was participating in the interlaboratory comparison organized by EURADOS in terms of the personal dose equivalent HP(0.07). The result of the comparison was satisfactory, therefore the correctness of the testing procedure was confirmed. Med Pr 2013;64(5):631–637
Źródło:
Medycyna Pracy; 2013, 64, 5; 631-637
0465-5893
2353-1339
Pojawia się w:
Medycyna Pracy
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wyznaczanie jednorodnych dawek równoważnych dla pacjentów leczonych techniką Simultaneous Integrated Boost
Determination of Equivalent Uniform Doses for patient treated with the Simultaneous Integrated Boost technique
Autorzy:
Araszkiewicz, Martyna
Korgul, Agnieszka
Kukołowicz, Paweł
Powiązania:
https://bibliotekanauki.pl/articles/2146769.pdf
Data publikacji:
2020
Wydawca:
Indygo Zahir Media
Tematy:
jednorodna dawka równoważna
radioterapia
IMRT
Simultaneous Integrated Boost
PTV
equivalent Uniform Dose
radiotherapy
Opis:
Celem radioterapii jest dostarczenie zaplanowanej dawki promieniowania do targetu przy jednoczesnym zminimalizowaniu dawki deponowanej w narządach krytycznych. Istnieją przypadki, gdzie w planie leczenia jednego pacjenta uwzględniono kilka obszarów tarczowych (ang. Planning Target Volume – PTV). Jedną z możliwych technik napromieniania jest wtedy tzw. technika Simultaneous Integrated Boost (SIB). Polega ona na jednoczesnym napromienianiu różnymi dawkami więcej niż jednej objętości tarczowej. Ze względu na konieczność jednoczesnego podania dawek w kilku targetach otrzymują one dawkę różną od zleconej. W pracy, stosując koncepcję jednorodnej dawki równoważnej (ang. Equivalent Uniform Dose – EUD), oceniono wzajemny wpływ dawek deponowanych w poszczególnych targetach.
Radiotherapy aims to deliver an appropriate dose of ionizing radiation to the target, minimizing the doses in critical organs. There are cases where several Planning Target Volume (PTV) are planned in the treatment plan for one patient that require different doses to be deposited. In such cases, one of the possible irradiation techniques is the so-called Simultaneous Integrated Boost (SIB) technique, in which all PTV are simultaneously irradiated with different doses. Due to the existing Beam Penumbra Effect, the application of a dose in one PTV affects the doses in the second PTV receiving a lower dose. In this paper, using the concept of the Equivalent Uniform Dose – EUD (EUD) the mutual influence of doses deposited in particular PTVs was assessed.
Źródło:
Inżynier i Fizyk Medyczny; 2020, 9, 3; 159--160
2300-1410
Pojawia się w:
Inżynier i Fizyk Medyczny
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Międzynarodowe podstawowe normy ochrony przed promieniowaniem i bezpieczeństwa źródeł promieniowania
“Radiation Protection and Safety of Radiadion Sources: International Basic Safety Standards” (No.GSR Part 3 IAEA, Vienna 2014)
Autorzy:
Musiałowicz, T.
Powiązania:
https://bibliotekanauki.pl/articles/214664.pdf
Data publikacji:
2015
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
bezpieczeństwo radiacyjne
bezpieczeństwo fizyczne
dawka efektywna
dawka równoważna
dawka graniczna
ogranicznik dawki
poziom odniesienia
dozór jądrowy
narażenie planowane
narażenie wyjątkowe
narażenie istniejące
narażenie zawodowe
narażenie ludności
narażenie medyczne
optymalizacja
ochrona przed promieniowaniem
równoważnik dawki
radiation safety
nuclear security
effective dose
equivalent dose
dose limit
dose constraint
reference level
regulator body
planned exposure
emergency exposure
existing exposure
occupational exposure
population exposure
medical exposure
optimisation
radiation protection
dose equivalent
Opis:
W artykule omówiono wydaną w roku ubiegłym przez MAEA publikację zawierającą „MIĘDZYNARODOWE PODSTAWOWE NORMY OCHRONY PRZED PROMIENIOWANIEM I BEZPIECZEŃSTWA ŹRÓDEŁ PROMIENIOWANIA”. Odrębnie scharakteryzowano wymagania dotyczące różnych sytuacji narażenia: planowanego narażenia, wyjątkowego narażenia i istniejącego narażenia. W zakończeniu artykułu, jego autor i współautor poprzednich wydań NORM (1967, 1996), przedstawia swoją opinię na temat omawianej publikacji.
New IAEA publication entitled “Radiation Protection and Safety of Radiadion Sources: International Basic Safety Standards”. (No.GSR PART 3 IAEA) was described in the paper. The main parts of that publication concerning different exposure situations: planned exposure, emergency exposure, existing exposure are discussed separately. In the conclusion author of the article and simultaneously co-author of former editions (1967, 1996) of the BESIC SAFETY REQUIREMENTS presents his own opinion on the described book.
Źródło:
Postępy Techniki Jądrowej; 2015, 3; 15-22
0551-6846
Pojawia się w:
Postępy Techniki Jądrowej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Prostota czy złożoność procesu wytwarzania radiofarmaceutyków w świetle optymalizacji ochrony radiologicznej personelu – $ \text{}^\text{99m}\text{Tc} $ vs $ \text{}^\text{18}\text{F} $
Simplicity or complexity of the radiopharmaceutical production process in the light of optimization of radiation protection of staff – $ \text{}^\text{99m}\text{Tc} $ vs $ \text{}^\text{18}\text{F} $
Autorzy:
Wrzesień, Małgorzata
Powiązania:
https://bibliotekanauki.pl/articles/2162470.pdf
Data publikacji:
2018-05-22
Wydawca:
Instytut Medycyny Pracy im. prof. dra Jerzego Nofera w Łodzi
Tematy:
medycyna nuklearna
detektor termoluminescencyjny
optymalizacja
radiofarmaceutyk
izotop
dawka równoważna
nuclear medicine
thermoluminescent detector
optimization
radiopharmaceutical
isotope
equivalent dose
Opis:
Wstęp Radiofarmaceutyk to produkt będący połączeniem niepromieniotwórczego związku chemicznego i znacznika izotopowego. Na bogatej liście izotopów mających zastosowane w medycynie na uwagę zasługują 2 – technet-99m ($ \text{}^\text{99m}\text{Tc} $) i fluor-18 ($ \text{}^\text{18}\text{F} $). Ich podobieństwo ogranicza się jedynie do diagnostycznego obszaru stosowalności, a dzieli je m.in. rodzaj i energia emitowanego promieniowania, czas połowicznego rozpadu czy w szczególności sposób produkcji. Izotop $ \text{}^\text{99m}\text{Tc} $ uzyskuje się dzięki generatorom nuklidów krótkożyciowych – molibdenu-99 ($ \text{}^\text{99}\text{Mo} $)/$ \text{}^\text{99m}\text{Tc} $, a $ \text{}^\text{18}\text{F} $ powstaje w reakcji jądrowej zachodzącej w cyklotronie. Stosunkowo łatwy sposób obsługi generatora $ \text{}^\text{99}\text{Mo} $/$ \text{}^\text{99m}\text{Tc} $ w porównaniu z koniecznością wykorzystania cyklotronu wydaje się sprzyjać zasadzie optymalizacji ochrony radiologicznej personelu. Weryfikacja tezy dotyczącej wpływu automatyki zarówno produkcji znacznika $ \text{}^\text{18}\text{F} $, jak i procesu znakowania deoksyglukozy na zoptymalizowanie ochrony radiologicznej pracowników w porównaniu z manualnymi procedurami wykonywanymi podczas znakowania preparatów izotopem $ \text{}^\text{99m}\text{Tc} $. Materiał i metody Dawki równoważne Hp(0,07) zmierzono w 5 zakładach medycyny nuklearnej i 2 ośrodkach produkujących znaczniki pozytonowe, w szczególności $ \text{}^\text{18}\text{F} $. W pomiarach dozymetrycznych wykorzystano wysokoczułe detektory termoluminescencyjne wykonane z fluorku litu (LiF: Mg, Cu, P – MCP-N). Wyniki Wśród czynności wykonywanych przez pracowników zarówno placówek produkujących $ \text{}^\text{18}\text{F} $-fluorodeoksyglukozę ($ \text{}^\text{18}\text{F} $-FDG), jak i zakładów medycyny nuklearnej manualne procedury kontroli jakości oraz znakowanie preparatu mają największy wkład do zarejestrowanych wartości dawek Hp(0,07). Wnioski Prosty sposób uzyskania znacznika $ \text{}^\text{99m}\text{Tc} $ podobnie jak złożony (choć w pełni zautomatyzowany) proces produkcji $ \text{}^\text{18}\text{F} $-FDG optymalizuje ochronę radiologiczną personelu z wyłączeniem manualnych procesów znakowania związków chemicznych $ \text{}^\text{99m}\text{Tc} $ bądź kontroli jakości $ \text{}^\text{18}\text{F} $-FDG. Med. Pr. 2018;69(3):317–327
Background A radiopharmaceutical is a combination of a non-radioactive compound with a radioactive isotope. Two isotopes: technetium- 99m ($ \text{}^\text{99m}\text{Tc} $) and fluorine-18 ($ \text{}^\text{18}\text{F} $) are worth mentioning on the rich list of isotopes which have found numerous medical applications. Their similarity is limited only to the diagnostic area of applicability. The type and the energy of emitted radiation, the half-life and, in particular, the production method demonstrate their diversity. The $ \text{}^\text{99m}\text{Tc} $ isotope is produced by a short-lived nuclide generator – molybdenum-99 ($ \text{}^\text{99}\text{Mo} $)/$ \text{}^\text{99m}\text{Tc} $, while $ \text{}^\text{18}\text{F} $ is resulting from nuclear reaction occurring in a cyclotron. A relatively simple and easy handling of the $ \text{}^\text{99}\text{Mo} $ \text{}^\text{99m}\text{Tc} $ generator, compared to the necessary use a cyclotron, seems to favor the principle of optimizing the radiological protection of personnel. The thesis on the effect of automation of both the $ \text{}^\text{18}\text{F} $ isotope production and the deoxyglucose labelling process on the optimization of radiological protection of workers compared to manual procedures during handling of radiopharmaceuticals labelled with $ \text{}^\text{99m}\text{Tc} $ need to be verified. Material and Methods Measurements of personal dose equivalent Hp(0.07) were made in 5 nuclear medicine departments and 2 radiopharmaceuticals production centers. High-sensitivity thermoluminescent detectors (LiF: Mg, Cu, P – MCP-N) were used to determine the doses. Results Among the activities performed by employees of both $ \text{}^\text{18}\text{F} $-fluorodeoxyglucose ($ \text{}^\text{18}\text{F} $-FDG) production centers and nuclear medicine departments, the manual quality control procedures and labelling of radiopharmaceuticals with $ \text{}^\text{99m}\text{Tc} $ isotope manifest the greatest contribution to the recorded Hp(0.07). Conclusions The simplicity of obtaining the $ \text{}^\text{99m}\text{Tc} $ isotope as well as the complex, but fully automated production process of the $ \text{}^\text{18}\text{F} $-FDG radiopharmaceutical optimize the radiation protection of workers, excluding manual procedures labelling with $ \text{}^\text{99m}\text{Tc} $ or quality control of $ \text{}^\text{18}\text{F} $-FDG. Med Pr 2018;69(3):317–327
Źródło:
Medycyna Pracy; 2018, 69, 3; 317-327
0465-5893
2353-1339
Pojawia się w:
Medycyna Pracy
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-12 z 12

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies