Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "diving suit" wg kryterium: Temat


Wyświetlanie 1-4 z 4
Tytuł:
Habitable underwater hyperbaric facilities: respiratory balance in the human organism during adapting to saturation nitrogen-oxygen hyperbaria
Zamieszkiwalne hiperbaryczne obiekty podwodne: równowaga oddechowa w organizmie człowieka podczas adaptacji do hiperbarii azotowo-tlenowej
Autorzy:
Gulyar, Sergiy A.
Barats, Yuri M.
Powiązania:
https://bibliotekanauki.pl/articles/366241.pdf
Data publikacji:
2019
Wydawca:
Polskie Towarzystwo Medycyny i Techniki Hiperbarycznej
Tematy:
underwater laboratory
Ikhtiander
hyperbaria
aquanaut
respiratory gases transport
saturation diving
regimes of oxygen dioxide in the organism
regimes of carbon dioxide in the organism
autonomous diving suit
submersible drilling rigs
laboratorium podwodne
hiperbaria
akwanaut
transport gazów oddechowych
nurkowanie nasycone
reżim tlenowy w organizmie
reżim dwutlenku węgla w organizmie
autonomiczny kombinezon nurkowy
wiertnice podwodne
Opis:
There were evaluated responses of the respiratory system to changes in the variables of the external environment under increased pressure. To the model of professional underwater human activity underwater served the conditions of full saturation in compressed air or nitrogen-oxygen gas mixtures. Technical devices were presented by a number of underwater laboratories, mounted at the bottom (Ikhtiander-66, 67 and 68), hyperbaric chambers, submersible drilling rigs (Bur-1 and 2), and an autonomous diving Ikhtiander-2 for a long stay in the water. Studies of respiratory gases mass transport conditions in man showed than within the pressure range of 0.25-1.1 MPa at density of moderate hyperoxic and nitrogen-helio-oxygen environment up to 14 kg/m3 oxygen and carbon dioxide regimes of the organism come to a new functional level which provides the adaptation to the extremal conditions. It is determined that an increase of physiological dead breathing space, a decrease of the rate of the O2 diffusion through the alveole-capillary barrier, intensification of unevenness of ventilator-perfusional relations in lungs and an increase of blood shunting in lungs are the main respiratory mechanisms which regulate mass transfer of O2 and CO2 in man under hyperbaria. The leading hemodynamic mechanism is the retention of volume blood circulation and cardiac output. It is studied how the compression rate, high partial pressures of oxygen and nitrogen, microclimate parameters in inhabited hypebaric chambers influence changes of functional breathing system. Absence of hypoxic state is proved in man (full saturation of man with nitrogen) under normoxia in nitrogen-oxygen environment with the density 6.34 kg/m3. These are also the data about accelerated rehabilitation of divers using the method of active adaptation o high altitudes. Basic directions in physiological studies of functional breathing system under increased pressure of gas and water environment are described.
Eksperymenty polegały na ocenie reakcji układu oddechowego na zmiany zmiennych środowiska zewnętrznego pod zwiększonym ciśnieniem. Badania dotyczyły wpływu na organizm ludzki całkowitego nasycenia mieszanin sprężonego powietrza lub azotu i tlenu. Szereg laboratoriów podwodnych zaprezentowało różnego rodzaju urządzenia techniczne do stosowania w środowisku podwodnym (Ikhtiander-66, 67 i 68). Należą do nich: komory hiperbaryczne, wiertnice podwodne (Bur-1 i 2) oraz autonomiczny kombinezon nurkowy przeznaczony do długotrwałych pobytów w wodzie. Badania dotyczące warunków transportu masowego gazów oddechowych u człowieka wykazały, że w zakresie ciśnień 0,25-1,1 MPa, przy gęstościach środowiska umiarkowanie hiperoksyjnego i azotowo-heliotlenowego do 14 kg/m3 w reżimie tlenowym i dla poziomu dwutlenku węgla w organizmie, osiągają one nowy poziom funkcjonalny, który ułatwia adaptację do warunków ekstremalnych. Stwierdzono, że zwiększenie fizjologicznej martwej przestrzeni oddechowej, zmniejszenie szybkości dyfuzji O2 poprzez barierę pęcherzykowo-kapilarną, nasilenie nierównomierności relacji powietrzno-perfuzjalnych w płucach oraz wzrost przepływu krwi w płucach są głównymi mechanizmami oddechowymi regulującymi masowy transfer O2 i CO2 u człowieka w warunkach hiperbarii. Głównym mechanizmem hemodynamicznym jest utrzymanie odpowiedniego krążenia krwi i rzutu serca. Zbadano, w jaki sposób stopień sprężania, wysokie ciśnienia cząstkowe tlenu i azotu oraz parametry mikroklimatyczne w komorach hiperbarycznych wpływają na zmiany w rozwoju układu oddechowego. Brak stanu niedotlenienia u człowieka (pełne nasycenie człowieka azotem) wykazano w warunkach normoksji w środowisku azot-tlen o gęstości 6,34 kg/m3. Dane te dotyczą również przyspieszonej rehabilitacji nurków z zastosowaniem metody aktywnej adaptacji na dużych wysokościach. Opisano podstawowe kierunki badań fizjologicznych czynnościowych układów oddechowych w warunkach zwiększonego ciśnienia gazu i środowiska wodnego.
Źródło:
Polish Hyperbaric Research; 2019, 3(68); 93-118
1734-7009
2084-0535
Pojawia się w:
Polish Hyperbaric Research
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The risk of developing a contact allergy to materials present in diving suits and diving equipment
Narażenie na alergię kontaktową na materiały skafandra i wyposażenia nurka
Autorzy:
Gadomski, K.
Siermontowski, P.
Dąbrowiecki, Z.
Olszaski, R.
Powiązania:
https://bibliotekanauki.pl/articles/1359796.pdf
Data publikacji:
2017
Wydawca:
Polskie Towarzystwo Medycyny i Techniki Hiperbarycznej
Tematy:
Allergic contact dermatitis
allergens
diving suit
diving
patch tests
alergiczny wyprysk kontaktowy skóry
alergeny
skafander nurkowy
nurkowanie
testy płatkowe
Opis:
Allergic contact eczema is the most common occupational skin disease caused by allergens. Thus far, no research has been conducted in Poland in relation to the development of contact allergies amongst divers resulting from particular diving suit components. A group of 86 divers were examined using allergy patch tests. Standard products of contact allergy diagnostics were used containing 40 allergens.
Alergiczny wyprysk kontaktowy jest najczęściej występującą chorobą zawodową skóry wywołaną przez alergeny. W Polsce dotychczas nie przeprowadzono badań dotyczących narażenia na alergię kontaktową na składniki skafandra nurkowego. Przebadano alergicznymi testami płatkowymi grupę 86 nurków. Zastosowano standardowe produkty do diagnostyki alergii kontaktowej z 40 alergenami.
Źródło:
Polish Hyperbaric Research; 2017, 2(59); 57-60
1734-7009
2084-0535
Pojawia się w:
Polish Hyperbaric Research
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Decontamination of a diving suit
Dekontaminacja kombinezonu nurkowego
Autorzy:
Dąbrowiecki, Z.
Dąbrowiecka, M.
Olszański, R.
Siermontowski, P.
Powiązania:
https://bibliotekanauki.pl/articles/366608.pdf
Data publikacji:
2016
Wydawca:
Polskie Towarzystwo Medycyny i Techniki Hiperbarycznej
Tematy:
diving
diving suit
decontamination
nurkowanie
kombinezon nurkowy
dekontaminacja
Opis:
When working in chemical or biological environments, contamination is an extremely dangerous issue for the rescue services of the fire department, police and the army. Modern protective overalls worn by fire fighters or dry "Viking" diving suits made from neoprene or nylon covered with polyurethane, have been proven to ensure sufficient protection. However, once the contaminated area is left, there is a need to perform decontamination of the external and internal surfaces of the protective overalls; in order to ensure the clothing continues to offer a high level of comfort and to retain the durability of said protective clothing, it is of course also necessary to perform a drying procedure. Moreover, there is a risk of a transfer of pathogenic micro-organisms between persons utilising the same protective clothes, particularly in the case of expensive specialist suits. Micro-organisms which may potentially spread through clothing include intestinal bacteria, such as: Salmonella, Shigella, Campylobacter, E. coli (including E. coli O157), C. difficile, viruses inducing infections of the upper respiratory tract and alimentary tract (noraviruses, rotaviruses, adeno and astroviruses). The risk of infection also involves the presence of the flu viruses, herpesviruses and pathogens transferred through skin, such as S. aureus (including MRSA), yeast-like fungi (Candida albicans), fungal strains inducing Tinea pedis and Tinea corporis [1]. Pathogenic micro-organisms can easily transfer from fabric surface onto the body of a person wearing protective clothing. From the numerous available techniques of decontamination of surfaces, equipment and protective clothing we propose to use for this purpose gaseous hydrogen peroxide (H2O2), a very effective biocidal agent. In field conditions, typical for the activities of rescue crews of the fire department, police and army we assume utilisation of a portable decontamination chamber enabling performance of a complete decontamination process. The process lasting approximately 3 hours encompasses 3 phases: • Drying phase; • Decontamination with gaseous hydrogen peroxide; • Catalytic combustion phase of hydrogen peroxide residues to a level safe for the environment. The integrated humidity and H2O2 level sensors ensure automatic control of the entire process and the unique distribution system of gaseous H2O2 secures full accessibility of the biocidal agent to the external surface of protective clothing as well as its interior. Moreover, the container allows for the conduction of the complete decontamination of the rescue equipment, night vision devices, binoculars, field telephones, radio stations, etc. Upon decontamination cycle completion, we obtain a completely dried suit which can be safely used by another crew member.
Praca w warunkach chemicznego lub biologicznego skażenia środowiska jest ekstremalnie niebezpieczna dla służb ratowniczych straży pożarnej, policji i wojska.Nowoczesne kombinezony robocze strażaków, suche kombinezony nurków typu ”Viking”, wykonane z neoprenu lub nylonu pokrytego poliuretanem, w dostatecznym stopniu zabezpieczają pracujących w nich ludzi. Jednak po opuszczeniu skażonego terenu istnieje konieczność odkażenia zewnętrznej i wewnętrznej powierzchni kombinezonów, a w celu utrzymania wysokiego komfortu pracy i długiej trwałości odzieży roboczej również przeprowadzenie procedury osuszenia wnętrza kombinezonu. Dodatkowo istnieje ryzyko przeniesienia patogennych drobnoustrojów pomiędzy osobami używającymi tej samej odzieży roboczej, szczególnie w przypadku drogich, specjalistycznych kombinezonów. Mikroorganizmy, które mogą potencjalnie rozprzestrzeniać się poprzez odzież obejmują bakterie jelitowe, takie jak: Salmonella, Shigella, Campylobacter, E.coli (w tym E.coli O157), C.difficile, wirusy wywołujące infekcje górnych dróg oddechowych oraz układu pokarmowego (norowirusy, rotawirusy, adeno- i astrowirusy). Ryzyko kontaminacji obejmuje również wirusy grypy, herpeswirusy oraz patogeny przenoszone poprzez skórę, takie jak S.aureus (w tym MRSA), grzyby drożdżopodobne (Candida albicans), szczepy grzybów wywołujących Tinea pedis (grzybica stóp) i Tinea corporis (grzybica skóry gładkiej). Drobnoustroje chorobotwórcze bardzo łatwo mogą przenosić się z powierzchni tkaniny na powierzchnię ciała pracownika używającego kombinezonu ochronnego. Z wielu dostępnych technik dekontaminacji powierzchni pomieszczeń, sprzętu i odzieży roboczej proponujemy wykorzystanie w tym celu gazowego nadtlenku wodoru (H2O2), bardzo efektywnego środka biobójczego. W warunkach polowych, typowych dla działań grup ratowniczych straży pożarnej, policji i wojska zakładamy użycie mobilnej komory dekontaminacyjnej, w której będzie można przeprowadzić cały proces odkażania. W trwającym około 3 godzin procesie występują trzy fazy: • Faza osuszenia; • Faza dekontaminacji gazowym nadtlenkiem wodoru; • Faza katalitycznego spalenia pozostałości nadtlenku wodoru do poziomu bezpiecznego dla środowiska. Wbudowane w komorę czujniki wilgotności i poziomu H2O2 będą automatycznie nadzorowały cały proces, a unikalny system rozprowadzenia gazowego H2O2 zabezpieczy pełną dostępność czynnika biobójczego do zewnętrznej powierzchni odzieży roboczej oraz do wszystkich miejsc we wnętrzu kombinezonu. W kontenerze można będzie również przeprowadzić pełną dekontaminację sprzętu ratowniczego, noktowizorów, lornetek, komputerów polowych, telefonów, radiostacji, itp. Po zakończeniu cyklu dekontaminacji uzyskujemy całkowicie osuszony kombinezon, który może być bezpiecznie użyty przez dowolnego członka zespołu.
Źródło:
Polish Hyperbaric Research; 2016, 4(57); 45-54
1734-7009
2084-0535
Pojawia się w:
Polish Hyperbaric Research
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Skażenie mikrobiologiczne kombinezonu nurkowego
Microbial contamination of a diving suit
Autorzy:
Dąbrowiecki, Z.
Dąbrowiecka, M.
Olszański, R.
Siermontowski, P.
Powiązania:
https://bibliotekanauki.pl/articles/1359550.pdf
Data publikacji:
2018
Wydawca:
Polskie Towarzystwo Medycyny i Techniki Hiperbarycznej
Tematy:
nurkowanie
kombinezon nurkowy
kontaminacja
diving
diving suit
contamination
Opis:
Drobnoustroje chorobotwórcze bardzo łatwo mogą przenosić się z powierzchni skóry nurka na powierzchnie tkaniny kombinezonu ochronnego. Długotrwały pobyt w komorze hiperbarycznej , jaki występuje podczas nurkowania saturowanego zwiększa ryzyko infekcji jeśli w komorze znajdzie się chociaż jeden nosiciel chorobotwórczych patogenów. Przeprowadzone badania potwierdziły, że sprzęt nurkowy znajdujący się w Ośrodkach Nurkowych, jest siedliskiem wielu różnych bakterii i grzybów, również tych patogennych. Ogromna większość drobnoustrojów znajdujących się na powierzchni pianek, kombinezonów itp. to komensale (niektóre z nich są organizmami oportunistycznymi), lecz fakt ten uświadamia nam, że powierzchnie sprzętu nurkowego są wspaniałą „drogą przenoszenia” różnych dermatoz i innych chorób. Aby zmniejszyć możliwość zakażenia należy sprzęt nurkowy, z którego korzystają różne osoby poddawać procesowi dekontaminacji. Autorzy rekomendują dekontaminację gazowym nadtlenkiem wodoru, który nie uszkadza sprzętu.
Pathogenic micro-organisms can easily transfer from the surface of a diver's skin onto the surfaces of a protective suit. A long-term stay in a hyperbaric chamber during a saturation dive increases the risk of infection if in the chamber there is even a single carrier of disease-causing pathogens. The conducted research has confirmed that the diving equipment located in Diving Centres is a place of many different bacteria and fungi, including pathogenic ones. The vast majority of microbes found on the surfaces of wetsuits, etc. are commensals (with some being opportunistic organisms). This fact allows us to realise that the surfaces of diving equipment are an excellent "transmission route" for various dermatoses and other diseases. In order to reduce the risk of infection the diving equipment used by various people should be subject to the process of decontamination. The authors recommend decontamination with the use of gaseous hydrogen peroxide which does not cause damage to equipment.
Źródło:
Polish Hyperbaric Research; 2018, 1(62); 61-74
1734-7009
2084-0535
Pojawia się w:
Polish Hyperbaric Research
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-4 z 4

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies