Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "dissipation factor" wg kryterium: Temat


Wyświetlanie 1-7 z 7
Tytuł:
Effect of dissipation factor on reflected and transmitted powers of a structure containing left-handed material waveguide
Autorzy:
Ubeid, M.F.
Shabat, M.M.
Sid-Ahmed, M.O.
Powiązania:
https://bibliotekanauki.pl/articles/412265.pdf
Data publikacji:
2013
Wydawca:
Przedsiębiorstwo Wydawnictw Naukowych Darwin / Scientific Publishing House DARWIN
Tematy:
electromagnetic waves
left-handed material
dissipation factor
frequency
transmitted power
reflected power
Opis:
In this paper a waveguide structure consisting of a pair of left-handed material (LHM) and dielectric slabs inserted in vacuum is investigated theoretically. Two cases of the LHM are considered, loss-less case and loss case as well as the frequency dependence of permittivity and permeability of it is taken into account. Maxwell's equations are used to determine the electric and magnetic fields of the incident waves at each layer. Snell's law is applied and the boundary conditions are imposed at each layer interface to calculate the reflected, transmitted and loss powers of the structure. Numerical results are illustrated to show the effect of frequency, angle of incidence and LHM thickness on the mentioned powers when the dissipation factor changes. The obtained results are in agreement with the law of conservation of energy.
Źródło:
International Letters of Chemistry, Physics and Astronomy; 2013, 3; 1-11
2299-3843
Pojawia się w:
International Letters of Chemistry, Physics and Astronomy
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wzorzec współczynnika strat dielektrycznych
Dielectric Dissipation Factor Standard
Autorzy:
Lisowski, M.
Powiązania:
https://bibliotekanauki.pl/articles/151650.pdf
Data publikacji:
2008
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
współczynnik stratności dielektrycznej
wzorzec
niskie wartości
niepewność
dialectic dissipation factor
standard
low value
uncertainty
Opis:
Wzorcowanie mierników pojemności elektrycznej C i współczynnika strat dielektrycznych tgδ jest utrudnione z powodu braku odpowiednio dokładnych wzorców tgδn. Wzorzec tgδn realizuje się najczęściej poprzez szere-gowe połączenie kondensatora z rezystorem o znanej wartości. Główną przyczyną niedokładności takiego wzorca, w zakresie niskich wartości, są parametry resztkowe rezystora. Opisane tutaj oryginalne rozwiązania wzorców tgδn przy częstotliwości 50 Hz mają wartości w zakresie (0,1÷10)×10^-4 określone z niepewnością 10^-5.
Calibration of electric capacitance C and the tgδ -factor of meters, used for permittivity and dielectric dissipation factor tgδ measurements, is difficult as there is no adequately accurate tgδn standards. Dielectric dissipation factor standards are made of series connection of known value capacitor and resistor. Main reason of inaccuracy this type of standard are mainly residual parameters of resistor. In this paper the special construction of the standards tgδn is described and results of testing measurement are gives. The standard tgbn has at frequency 50 Hz the range (0.1÷10)×10-4 and uncertainty of value 10-5.
Źródło:
Pomiary Automatyka Kontrola; 2008, R. 54, nr 9, 9; 650-652
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
A new method for on-line monitoring of bushings, transients and PD of power transformers
Nowe metody monitoringu on-line przepustów, przepięć i wyładowań niezupełnych transformatorów energetycznych
Autorzy:
Koch, M.
Kołtunowicz, W.
Krüger, M.
Powiązania:
https://bibliotekanauki.pl/articles/156993.pdf
Data publikacji:
2013
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
power transformers
bushings
on-line monitoring
dissipation factor
capacitance
PD
UHF
transformator energetyczny
przepust
monitoring on-line
współczynnik strat
pojemność
WNZ
Opis:
This paper describes a new on-line method for capacitance and dissipation factor measurements of high voltage bushings, for recording grid transients and for partial discharge monitoring at power transformers. The needed accuracy for reliable detection of failures is in the range of 5 pF for capacitance and 0.1 % for dissipation factor. To overcome these shortcomings, this paper introduces an absolute method for measuring capacitance and dissipation factor of HV bushings. As for off-line measurements, the discrimination between noise and true internal discharges is the key for successful diagnosis. Strategies for sensitive partial discharge measurements under disturbed on-line conditions are described, also involving measurements in the UHF range.
Artykuł opisuje nowe metody pomiaru on-line pojemności i współczynnika strat przepustów wysokonapięciowych na potrzeby, monitorowania przepięć w sieci i wyładowań niezupełnych w transformatorach energetycznych. Według statystyk awaryjności przepusty WN są jedną z głównych przyczyn awarii transformatorów, co motywuje operatorów do ciągłego monitoringu on-line stanu układów izolacyjnych. Na potrzeby wiarygodnej diagnostyki wymagana jest dokładność pomiaru pojemności rzędu 5 pF i współczynnika strat rzędu 0,1%. Aby uzyskać taką rozdzielczość, wskutek braku symetrii w sieci, nie wystarczy względne porównanie prądów mierzonych w zaciskach pomiarowych w przepustach trzech faz. Dodatkowo, ten sposób pomiaru nie pozwala identyfikować procesu starzenia przebiegającego w trzech fazach ze zbliżonym tempem. W artykule przedstawiono metodę pomiaru rzeczywistych wartości pojemności i współczynnika strat przepustów WN. Pozwala ona uzyskać dokładność podobną do pomiarów off-line nawet w warunkach eksploatacyjnych. Wyładowania niezupełne są wczesnym wskaźnikiem zbliżającego się przebicia w izolacji WN. Ich pomiar na zacisku przepustu WN umożliwia wykrycie defektów w izolacji przepustu oraz transformatora. Podobnie jak w pomiarach off-line, rozróżnienie zakłóceń od rzeczywistych wyładowań wewnętrz izolacji jest kluczem do poprawnej diagnostyki. Opisano strategie czułego pomiaru wyładowań niezupełnych w warunkach on-line, z uwzględnieniem zakresu UHF.
Źródło:
Pomiary Automatyka Kontrola; 2013, R. 59, nr 2, 2; 120-124
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Capacitor sensor impedance parameter measurement method for the degradation degree evaluation of hydraulic oil in the process of thermal oxidation
Metoda pomiaru parametrów impedancyjnych czujnika pojemnościowego do oszacowania stopnia degradacji oleju hydraulicznego w procesie termoutleniania
Autorzy:
Umiński, W.
Powiązania:
https://bibliotekanauki.pl/articles/256420.pdf
Data publikacji:
2013
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Technologii Eksploatacji - Państwowy Instytut Badawczy
Tematy:
oil degradation
capacitive sensor
capacitor impedance
quality factor
dissipation factor
equivalent series resistance
microprocessor LCR meter
stan oleju
czujnik pojemnościowy
impedancja kondensatora
współczynnik stratności
rezystancja strat kondensatora
mikroprocesorowy miernik pojemności
Opis:
The paper describes a diagnostic method for the evaluation of the condition of hydraulic oil with the use of the dependence between oil degradation and changes in capacitor sensor impedance components. A series of new capacitive sensors has been developed, and impedance components measurements of hydraulic oil HL-46 laboratory oxidative degradation were conducted by means of microprocessor-based LCR meter. Preliminary laboratory measurement results have shown that equivalent series resistance ESR and quality factor Q of a capacitor series circuit model are most suitable for the evaluation of the condition of oil. The measurements indicated the best capacitive sensor sensitivity.
W artykule przedstawiono metodę badawczą umożliwiającą ocenę zmian stanu oleju hydraulicznego w procesie termoutleniania poprzez pomiar za pomocą mikroprocesorowego miernika LCR, zmian parametrów impedancyjnych zastępczego układu szeregowego lub równoległego czujnika pojemnościowego (określanego również jako kondensator pomiarowy) zanurzonego w oleju. Opisano konstrukcję czujnika oraz zaprezentowano wybrane wyniki wstępnych pomiarów parametrów impedancyjnych dla różnych typów i rodzajów czujników dla próbek oleju hydraulicznego HL-46 poddanych laboratoryjnemu termoutlenianiu. Wyniki pomiarów pozwoliły wytypować zarówno parametry impedancyjne, jak i wykonanie czujnika w aspekcie najlepszej detekcji zmian stanu oleju.
Źródło:
Problemy Eksploatacji; 2013, 3; 147-158
1232-9312
Pojawia się w:
Problemy Eksploatacji
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The influence of temperature on the damping characteristic of hydraulic shock absorbers
Autorzy:
Hryciów, Zdzisław
Rybak, Piotr
Gieleta, Roman
Powiązania:
https://bibliotekanauki.pl/articles/1841747.pdf
Data publikacji:
2020
Wydawca:
Polska Akademia Nauk. Polskie Naukowo-Techniczne Towarzystwo Eksploatacyjne PAN
Tematy:
hydraulic shock absorber
performance
damping factor
temperature
dissipation energy
Opis:
This paper presents the results of bench-tests and calculations assessing the influence of temperature on the performance of a two-pipe hydraulic shock absorber. The shock absorber prepared for the tests was cooled with dry ice to a temperature corresponding to that associated with the average winter conditions in a temperate climate. The temperature range of the shock absorber during testing was ensured via equipping it with a thermocouple and monitoring it with a thermal imaging camera. During testing, the shock absorber was subjected to kinematic forces of a selected frequency with two different, fixed displacement amplitudes. The results of the tests showed a direct correlation between the decrease of component resistance at lower temperatures. The rate of change in resistance was higher at lower temperatures. It was also found that the energy dissipated in one shock cycle decreased linearly with an increasing temperature. Finally, a method for determining the ideal use temperature of the shock absorber for the assumed operating conditions was also presented.
Źródło:
Eksploatacja i Niezawodność; 2021, 23, 2; 346-351
1507-2711
Pojawia się w:
Eksploatacja i Niezawodność
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Antiplane deformation of a bimaterial containing an interfacial crack with the account of friction. [P.] 1, Single loading
Autorzy:
Sulym, H.
Piskozub, L.
Piskozub, Y.
Pasternak, I.
Powiązania:
https://bibliotekanauki.pl/articles/386802.pdf
Data publikacji:
2015
Wydawca:
Politechnika Białostocka. Oficyna Wydawnicza Politechniki Białostockiej
Tematy:
friction
interfacial crack
energy dissipation
stress intensity factor
antiplane deformation
longitudinal shear
bi-material
discontinuity functions
tarcie
pęknięcia międzyfazowe
rozproszenie energii
ścinanie podłużne
biomateriały
funkcje nieciągłe
Opis:
The paper presents the exact analytic solution to the antiplane problem for a non-homogeneous bimaterial medium containing closed interfacial cracks, which faces can move relatively to each other with dry friction. The medium is subjected to the action of normal and arbitrary single loading in a longitudinal direction. Based on the discontinuity function method the problem is reduced to the solution of the system of singular integral-differential equations for stress and displacement discontinuities at the possible slippage zones. Influence of loading parameters and the effects of friction on the sizes of these zones is analyzed. The stress intensity factors, stress and displacement discontinuities, energy dissipation are determined for several characteristic types of external loading.
Źródło:
Acta Mechanica et Automatica; 2015, 9, 2; 115-121
1898-4088
2300-5319
Pojawia się w:
Acta Mechanica et Automatica
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Antiplane deformation of a bimaterial containing an interfacial crack with the account of friction 2. Repeating and cyclic loading
Autorzy:
Sulym, H.
Piskozub, L.
Piskozub, Y.
Pasternak, I.
Powiązania:
https://bibliotekanauki.pl/articles/387479.pdf
Data publikacji:
2015
Wydawca:
Politechnika Białostocka. Oficyna Wydawnicza Politechniki Białostockiej
Tematy:
friction
tribofatigue
cyclic loading
interfacial crack
energy dissipation
stress intensity factor
antiplane deformation
bi-material
hysteresis
discontinuity functions
tarcie
obciążenie cykliczne
pęknięcia międzyfazowe
rozpraszanie energii
współczynnik intensywności naprężeń
histereza
bimateriał
Opis:
The paper presents the exact solution of the antiplane problem for an inhomogeneous bimaterial with the interface crack exposed to the normal load and cyclic loading by a concentrated force in the longitudinal direction. Using discontinuity function method the problem is reduced to the solution of singular integral equations for the displacement and stress discontinuities at the domains with sliding friction. The paper provides the analysis of the effect of friction and loading parameters on the size of these zones. Hysteretic behaviour of the stress and displacement discontinuities in these domains is observed.
Źródło:
Acta Mechanica et Automatica; 2015, 9, 3; 178-184
1898-4088
2300-5319
Pojawia się w:
Acta Mechanica et Automatica
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-7 z 7

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies