Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "disinfection of waste" wg kryterium: Temat


Wyświetlanie 1-2 z 2
Tytuł:
Ecological and economically optimal management of waste from healthcare facilities
Autorzy:
Marczak, H.
Powiązania:
https://bibliotekanauki.pl/articles/123818.pdf
Data publikacji:
2013
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
management
medical waste
infectious waste
municipal waste
disinfection of waste
disposal of waste
cost of waste management
Opis:
Modern healthcare facilities generate more and more waste, and their management isa significant constitutes a significant cost of their functioning. The undertakings aimed at lowering the costs of expenses in waste management may have a positive influence on budgetary accounts in the institutions rendering health care services. On the example of a hospital in Lublin the costs of waste management and the possibilities to lower these costs by intensifying segregation procedures were presented. Moreover, the article presents the influence of specific waste neutralisation on the costs of waste
Źródło:
Journal of Ecological Engineering; 2013, 14, 2; 43-48
2299-8993
Pojawia się w:
Journal of Ecological Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The Phenomenon of Medical Waste Recycling in Indonesia: Contact Time and Chlorine Dose as a Disinfectant with the Bio-Indicator Bacillus subtilis and Bacillus stearothermophilus
Autorzy:
Fikri, Elanda
Kurniati, Iis
Wartiniyati, -
Prijanto, Teguh Budi
Pujiono, -
Syarief, Osman
Khair, Amar Sharaf Eldin
Powiązania:
https://bibliotekanauki.pl/articles/1839585.pdf
Data publikacji:
2021
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
recycling
medical waste
dosage
duration of contact
chlorine
disinfection
Opis:
Efforts that have been done to manage the Hazardous and Toxic waste into non-Hazardous and Toxic waste are done by emptying, shredding, washing, and rinsing at least 3 times and disinfecting using chlorine. This is in accordance with the Indonesian Regulation of Ministry of Health No. 27 of 2017, which has stated that surface cleaning is permitted to use 0.05% chlorine during the process. Furthermore, in the Indonesian Regulation of the Ministry of Environment and Forestry No.56 of 2015, the chemical disinfection process is permitted to use an additional 3–6% sodium hypochlorite (NaOCl). However, there are still differences in dosage and it has not been mentioned regarding the immersion period during the disinfection process on both of the regulations. The purpose of this study was to determine the difference in contact time and the dose of chlorine as a disinfectant on the number of Bacillus subtilis and Bacillus stearothermophilus in the medical waste recycling process. The research design used in this study was a Randomized Factorial Design with experimental research type. A total of 104 recyclable medical waste samples were taken, using 3 treatments and 6 repetitions. The average temperature of the chlorine solution at the contact time of 15 minutes, 30 minutes, and 45 minutes was 24.34 °C; 24,53 °C; and 24,54 °C respectively, while the average pH of the chlorine solution at the contact time of 15 minutes, 30 minutes, and 45 minutes was 8.344; 8,375; and 8,461 respectively. The results showed that there was no difference in the duration of contact and the dose of chlorine as a disinfectant in the medical waste recycling process with a p-value of 0.377. The percentage reduction in the number of Bacillus subtilis and Bacillus stearothermophilus before and after treatment was 99.99% based on 4 positive controls. The findings in this study were the duration of contact time and the effective dose used in the recycling process of medical waste, which was at a dosage of 0.03% with 45 minutes of contact time. The government needs to conduct a re-assessment regarding the recommended ideal dosage in the surface disinfection process so that it would not cause a potential risk to humans or the environment.
Źródło:
Journal of Ecological Engineering; 2021, 22, 4; 47-58
2299-8993
Pojawia się w:
Journal of Ecological Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-2 z 2

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies