Tytuł:
Rola tomosyntezy oraz mammografii spektralnej w diagnostyce kobiet z gęstym utkaniem piersi
The role of tomosynthesis and spectral mammography in the diagnostic of women with dense breast
Autorzy:
Bojkowski, Małgorzata
Wojnarska, Aleksandra
Koper, Beata
Powiązania:
https://bibliotekanauki.pl/articles/2146772.pdf
Data publikacji:
2020
Wydawca:
Indygo Zahir Media
Tematy:
cyfrowa tomosynteza piersi
mammografia spektralna
rak piersi
diagnostyka piersi
digital breast tomosynthesis
spectral mammography
contrast enhanced spectral mammography
breast cancer
breast diagnostics
Opis:
Podstawowym badaniem przesiewowym we wczesnym rozpoznawaniu raka piersi jest klasyczna mammografia rentgenowska. Ze względu na jej ograniczenia obserwowany jest ciągły rozwój nowych technik obrazowania piersi. Cyfrowa tomosynteza piersi DBT (Digital Breast Tomosynthesis) i mammografia spektralna CESM (Contrast Enhanced Spectral Mammography) znajdują szczególne zastosowanie w diagnostyce kobiet o gęstym utkaniu gruczołów piersiowych. Metody te są obecnie wykonywane jako badania uzupełniające w diagnostyce, stagingu oraz odpowiedzi na leczenie chemioterapią. Celem artykułu jest omówienie, w oparciu o literaturę, cyfrowej tomosyntezy piersi oraz mammografii spektralnej ze szczególnym uwzględnieniem ich zastosowania w diagnostyce uzupełniającej piersi o gęstej strukturze.
The primary screening test for early diagnosis of breast cancer is classic X-ray mammography. Due to its limitations, continuous development of new breast imaging techniques is observed. DBT (Digital Breast Tomosynthesis) and spectral mammography CESM (Contrast Enhanced Spectral Mammography) are used especially in the diagnosis of women with dense breast gland. At present these methods are available as complementary studies in diagnostics, staging and response to chemotherapy. The aim of the article is to discuss, based on literature, digital tomosynthesis and spectral mammography with particular emphasis on their use in complementary diagnostics of densely structured breasts.
Źródło:
Inżynier i Fizyk Medyczny; 2020, 9, 3; 203--206
2300-1410
Pojawia się w:
Inżynier i Fizyk Medyczny
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The threshold contrast thickness evaluated with different CDMAM phantoms and software
Autorzy:
Fabiszewska, E.
Grabska, I.
Pasicz, K.
Powiązania:
https://bibliotekanauki.pl/articles/146660.pdf
Data publikacji:
2016
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
CDMAM phantom
digital mammography
threshold visibility
Opis:
The image quality in digital mammography is described by specifying the thickness and diameter of disks with threshold visibility. The European Commission recommends the CDMAM phantom as a tool to evaluate threshold contrast visibility in digital mammography [1, 2]. Inaccuracy of the manufacturing process of CDMAM 3.4 phantoms (Artinis Medical System BV), as well as differences between software used to analyze the images, may lead to discrepancies in the evaluation of threshold contrast visibility. The authors of this work used three CDMAM 3.4 phantoms with serial numbers 1669, 1840, and 1841 and two mammography systems of the same manufacturer with an identical types of detectors. The images were analyzed with EUREF software (version 1.5.5 with CDCOM 1.6. exe fi le) and Artinis software (version 1.2 with CDCOM 1.6. exe fi le). The differences between the observed thicknesses of the threshold contrast structures, which were caused by differences between the CDMAM 3.4 phantoms, were not reproduced in the same way on two mammography units of the same type. The thickness reported by the Artinis software (version 1.2 with CDCOM 1.6. exe fi le) was generally greater than the one determined by the EUREF software (version 1.5.5 with CDCOM 1.6. exe fi le), but the ratio of the results depended on the phantom and diameter of the structure. It was not possible to establish correction factors, which would allow correction of the differences between the results obtained for different CDMAM 3.4 phantoms, or to correct the differences between software. Great care must be taken when results of the tests performed with different CDMAM 3.4 phantoms and with different software application are interpreted.
Źródło:
Nukleonika; 2016, 61, 1; 53-59
0029-5922
1508-5791
Pojawia się w:
Nukleonika
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Porównanie wybranych systemów obrazowania cyfrowego w mammografii
Comparison of chosen digital imaging systems in mammography
Autorzy:
Jakubowska, T.
Powiązania:
https://bibliotekanauki.pl/articles/262184.pdf
Data publikacji:
2012
Wydawca:
Politechnika Wrocławska. Wydział Podstawowych Problemów Techniki. Katedra Inżynierii Biomedycznej
Tematy:
mammografia cyfrowa
obrazowanie cyfrowe
DR
CR
digital mammography
digital imaging
dynamic replacement (DR)
computed radiography (CR)
Opis:
Mammografia jest najbardziej czułym i specyficznym badaniem w diagnozowaniu raka sutka. Zastosowanie techniki cyfrowej CR (Computed Radiography) i DR (Digital Radiography) ma na celu poprawę jakości obrazów, a co za tym idzie poprawę wykrywalności zmian przy jednoczesnym skróceniu czasu badania i obniżeniu dawki promieniowania. Niniejsza praca przedstawia porównanie stosowanych obecnie w mammografii wybranych systemów cyfrowych pod względem jakości obrazowania, jak również stosowanych dawek.
Mammography is a most sensitive and specific examination used in the breast cancer diagnosis. Digital radiographic systems CR (Computed Radiography) and DR (Digital Radiography) offer the high quality imaging with shorter exposure times, thus lowering the radiation dose. In this paper, the comparison of frequently used mammographic digital systems in terms of the imaging quality and doses applied, is presented.
Źródło:
Acta Bio-Optica et Informatica Medica. Inżynieria Biomedyczna; 2012, 18, 4; 260-266
1234-5563
Pojawia się w:
Acta Bio-Optica et Informatica Medica. Inżynieria Biomedyczna
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-3 z 3

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies