Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "diffraction phase microscopy" wg kryterium: Temat


Wyświetlanie 1-5 z 5
Tytuł:
Phase Object Observation System Based on Diffraction Phase Microscopy
Autorzy:
Babicz, S.
Stawarz-Graczyk, B.
Wierzba, P.
Powiązania:
https://bibliotekanauki.pl/articles/221523.pdf
Data publikacji:
2018
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
diffraction phase microscopy
DPM
phase objects
Opis:
In the paper authors present a special measurement system for observing phase objects. The diffraction phas microscopy makes it possible to measure the dimensions of a tested object with a nanometre resolution. To meet this requirement, it is proposed to apply a spatial transform. The proposed setup can be based either on a two lenses system (called 4f) or a Wollaston prism. Both solutions with all construction aspects are described in the paper. To make a full analysis of the object shape the authors developed an accurate image processing algorithm, also presented in the paper.
Źródło:
Metrology and Measurement Systems; 2018, 25, 1; 213-221
0860-8229
Pojawia się w:
Metrology and Measurement Systems
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Diffraction phase microscopy for observation on red blood cells fluctuation
Układ do obserwacji fluktuacji erytrocytów z wykorzystaniem dyfrakcyjnego mikroskopu fazowego
Autorzy:
Babicz-Kiewlicz, S.
Stawarz-Graczyk, B.
Wierzba, P.
Mazikowski, A.
Powiązania:
https://bibliotekanauki.pl/articles/268183.pdf
Data publikacji:
2015
Wydawca:
Politechnika Gdańska. Wydział Elektrotechniki i Automatyki
Tematy:
diffraction phase microscopy
RBC
medical diagnostics
dyfrakcyjny mikroskop fazowy
diagnostyka medyczna
Opis:
Nowadays there is quite huge need for more and more precise and effective fast diagnostics methods in hematology diseases. One of the most important blood components are erythrocytes – RBCs (Red Blood Cells). Due to their size they are easy to observe using microscopy. It is commonly known that the shape and lifetime of RBCs allows for early disease identification. Authors present special measurement system for RBCs fluctuations observation using diffraction phase microscopy which is also described in theory.
Istnieje zapotrzebowanie na coraz bardziej precyzyjne i bardziej efektywne metody szybkiej diagnostyki w kierunku chorób hematologicznych. Jednym z głównych składników krwi są erytrocyty (RBC –Red Blood Cells), które z uwagi na swój rozmiar mogą być łatwo obserwowalne. Powszechnie wiadomo, że kształt i długość życia tych komórek pozwala na wczesną identyfikację stanów chorobowych. Najnowsze wyniki badań świadczą też, że oprócz tych cech istotną informację zawiera przebieg fluktuacyjny erytrocytów. Autorzy proponują układ do obserwacji fluktuacji czerwonych komórek krwi z wykorzystaniem dyfrakcyjnego mikroskopu fazowego.
Źródło:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej; 2015, 46; 13-16
1425-5766
2353-1290
Pojawia się w:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Structural Transition in SrZnO Laser Pulse Deposited Alloy
Autorzy:
Albrithen, H. A.
Elnaggar, M.
Ozga, K.
Szota, M.
Alahmed, Z. A.
Alanazi, A. Q.
Alshahrani, H.
Alfaifi, E.
Djouadi, M. A.
Labis, J. P.
Powiązania:
https://bibliotekanauki.pl/articles/355190.pdf
Data publikacji:
2017
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
oxide materials
solid state alloys
structural phase transition
X-ray diffraction
scanning electron microscopy
Opis:
We have discovered a structural transition for the SrZnO alloy films from a wurtzite to a rock-salt structure, leading to a reduction in the (112̲0)/(0001) surface energy ratio. The films were grown by pulsed laser deposition using different SrO ratios, x. We have revealed that growth at a higher temperature, 750°C, resulted in a sharp 0002 peak at a low SrO content (5%), whereas growth at a higher SrO content (10%) resulted in a non-crystalline film with minute crystallites with a (112̲0) orientation. Generally the crystallinity decreased as the SrO content increased. No results obtained for the crystalline films showed any orientation of significant peaks besides the peak attributed to the (0001) plane, suggesting epitaxial growth. Optical measurements showed difference in transmission widows of alloys with different SrO percentage, and this was correlated to SrO influence on growth mode as indicated by scanning electron imaging. The studied SrZnO films, with SrO/(SrO + ZnO) ≤ 0.25, were grown by pulsed laser deposition using different SrO ratios, x. The effects of temperature and oxygen pressure during growth on the films’ structural properties were investigated. XRD results indicate that the film crystallinity was improved as the temperature and O2 pressure increased up to 650°C and 0.5 Torr, respectively.
Źródło:
Archives of Metallurgy and Materials; 2017, 62, 1; 211-216
1733-3490
Pojawia się w:
Archives of Metallurgy and Materials
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Evaluation of the Possibility of Applying Spatial 3D Imaging Using X-Ray Computed Tomography Reconstruction Methods for Quantitative Analysis of Multiphase Materials
Rentgenowska analiza ilościowa materiałów wielofazowych z wykorzystaniem przestrzennego obrazowania (3D) przy użyciu metod rekonstrukcji tomografii komputerowej
Autorzy:
Matysik, P.
Chojnacki, M.
Jóźwiak, S.
Czujko, T.
Lipiński, S.
Powiązania:
https://bibliotekanauki.pl/articles/353166.pdf
Data publikacji:
2015
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
computed tomography
electron microscopy
X-ray diffraction
stereology
phase analysis
quantitative research
tomografia komputerowa
mikroskopia elektronowa
dyfrakcja rentgenowska
stereologia
analiza fazy
badania ilościowe
Opis:
In this paper the possibility of using X-ray computed tomography (CT) in quantitative metallographic studies of homogeneous and composite materials is presented. Samples of spheroidal cast iron, Fe-Ti powder mixture compact and epoxy composite reinforced with glass fibers, were subjected to comparative structural tests. Volume fractions of each of the phase structure components were determined by conventional methods with the use of a scanning electron microscopy (SEM) and X-ray diffraction (XRD) quantitative analysis methods. These results were compared with those obtained by the method of spatial analysis of the reconstructed CT image. Based on the comparative analysis, taking into account the selectivity of data verification methods and the accuracy of the obtained results, the authors conclude that the method of computed tomography is suitable for quantitative analysis of several types of structural materials.
W pracy przedstawiono możliwość wykorzystania rentgenowskiej tomografii komputerowej (CT) w ilościowych badaniach metalograficznych materiałów jednorodnych oraz kompozytowych. Badaniom porównawczym poddano wypraskę mieszaniny proszkowej Fe – Ti, żeliwo sferoidalne, a także kompozyt epoksydowy zbrojony włóknami szklanymi. Udział objętościowy poszczególnych składników strukturalnych określano za pomocą klasycznych metod stereologicznych z wykorzystaniem skaningowej mikroskopii elektronowej (SEM) oraz metodami rentgenowskiej analizy ilościowej (XRD). Uzyskane typowymi metodykami wyniki porównano z rezultatami otrzymanymi za pomocą metody przestrzennej analizy obrazu tomografii komputerowej. Na podstawie przeprowadzonych analiz, biorąc pod uwagę selektywny sposób weryfikacji danych oraz dokładność uzyskiwanych wyników, można stwierdzić przydatność wykorzystania metody tomografii komputerowej, w obszarze ilościowej analizy strukturalnej szerokiego spektrum materiałów konstrukcyjnych.
Źródło:
Archives of Metallurgy and Materials; 2015, 60, 4; 2663-2670
1733-3490
Pojawia się w:
Archives of Metallurgy and Materials
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Techniki dyfrakcji rentgenowskiej
Autorzy:
Bonarski, J
Powiązania:
https://bibliotekanauki.pl/articles/273763.pdf
Data publikacji:
2013
Wydawca:
Roble
Tematy:
dyfrakcja rentgenowska
mikrostruktura
rentgenowska ilościowa analiza fazowa
RIAF
rentgenowska tomografia teksturowa
RTT
mikroskopia akustyczna
X-ray diffraction
microstructure
X-ray quantitative phase analysis
X-ray texture chromatography
acoustic microscopy
Źródło:
LAB Laboratoria, Aparatura, Badania; 2013, 18, 4; 26-30
1427-5619
Pojawia się w:
LAB Laboratoria, Aparatura, Badania
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-5 z 5

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies