Tytuł:
Uboczne produkty dezynfekcji wody
By-products of water disinfection
Autorzy:
Zbieć, E.
Dojlido, J.
Powiązania:
https://bibliotekanauki.pl/articles/237031.pdf
Data publikacji:
1999
Wydawca:
Polskie Zrzeszenie Inżynierów i Techników Sanitarnych
Tematy:
dezynfekcja wody
dezynfekcja chemiczna wody
utleniacze
Opis:
Three oxidants have found wide acceptance in water disin-fection-chlorine, chlorine dioxide and ozone. Of these, chlorine has been preferred for the past decades. Unfortunately, chlorine has the inherent disadvantage of reacting with the micropollu-tants present in the water to produce derivatives of the halogen group, which are all cancerogenic or mutagenic compounds. Thus, in order to overcome the problem of chlorine derivative formation, the use of ozone as disinfectant has become more and more frequent. But it soon became obvious that the reaction of ozone with water pollutants yielded equally hazardous pro ducts, mostly carbonyl derivatives and bromoacetonitriles. Although ozone is a strong biocide, it is seldom used singly because of its instability. The most frequent use of ozone as disinfectant is in combination with chlorine or chlorine dioxide, which, again leads to the formation of a number of toxic by-products. The mechanisms tfiat govern the production of these toxic species or are responsible for their toxicity have not been satisfactorilyexplainedyet. The authors of the present paper provide adetailed account of the chemical compounds produced in a variety of Poland's waterworks in the course of the disinfection process. Particular consideration is given to the water treatment plants of the city of Warsaw, where use is made of chlorine, ozone and chlorine dioxide as disinfectants. Presented are also the potentialities for determining the by-products in potable water.
Źródło:
Ochrona Środowiska; 1999, 3; 37-44
1230-6169
Pojawia się w:
Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analiza azotanów i bromianów powstających podczas dezynsekcji wody ozonem
Analysis of pollutants found in municipal water and of those forming in the course of ozon disinfection
Autorzy:
Gierak, A.
Leboda, R.
Powiązania:
https://bibliotekanauki.pl/articles/236969.pdf
Data publikacji:
1999
Wydawca:
Polskie Zrzeszenie Inżynierów i Techników Sanitarnych
Tematy:
azotany
bromiany
dezynfekcja wody
Opis:
When the surface water to be treated contains bromides and ammonium salts, ozonation will stimulate the formation of bromates, nitrites and nitrates, which have been identified as potential cancerogenic species. The admissible concentration of nitrates defined in Polish Standards is 10 gN/m (which corresponds to ca. 44 gNO3/m3 ). In Germany, the admissible concentration of nitrites must not exceed 0.1 gN/m3 . In Poland, the admissible concentration ofbromates has not been established yet. The maximal admissible concentrations of bromates in drinking water recommended by US EPA and WHO range between 10 and 50mgBr03 /m3. Moreover, it is postulated that, in future, these levels should be decreased to 5 mg/m3 , as soon as appropriate methods have been developed to enable determination of such low bromate levels. The objective of the present study was to discuss the problems that have to be tackled when determining bromate and nitrate concentrations in municipal water by high-performance ion-exchange chromatograpliy (IC-HPLC) or other teclmiques. Our investigations fiave sliown that direct determinations of nitrates and bromates are feasible at concentrations of 2 gNO3/m3 and over 0.2 gBrO3/m3, respectively.
Źródło:
Ochrona Środowiska; 1999, 4; 13-16
1230-6169
Pojawia się w:
Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Technologiczno-techniczne i ekonomiczne aspekty dezynfekcji wody roztworami produkowanymi w elektrolizerach
Technological and Economical Aspects of Water Disinfection With the Compounds Produced in Electrolyzers
Autorzy:
Wąsowski, J.
Waściszewska, M.
Powiązania:
https://bibliotekanauki.pl/articles/236446.pdf
Data publikacji:
2003
Wydawca:
Polskie Zrzeszenie Inżynierów i Techników Sanitarnych
Tematy:
dezynfekcja wody
elektrochlorowanie
Miox
water disinfection
electrochlorination
Opis:
W pracy omówiono zasadę i typową instalację do produkcji dezynfektanta z chlorku sodu metodą elektrolityczną. Przedstawiono korzyści jak i wady metody elektrochlorowania wody na tle powszechnie stosowanego w stacjach uzdatniania chloru gazowego i handlowego podchlorynu sodu. Do głównych korzyści wynikających z produkcji dezynfektanta w miejscu jego zastosowania należy zaliczono eliminację zagrożeń dla środowiska, ograniczenie problemów związanych z korozją oraz dodatkowo - w wypadku stosowania mieszaniny utleniaczy wytwarzanej w systemie Miox - zmniejszenie ilości powstających THM i HAA5 w uzdatnionej wodzie, efektywniejsze niszczenie mikroorganizmów oraz skuteczne usuwanie biofilmu z sieci wodociągowej. Przeprowadzona analiza ekonomiczna wykazała, iż produkowanie podchlorynu sodu i mieszaniny Miox metodą elektrolityczną jest szczególnie korzystne dla potrzeb dezynfekcji wody w małych i średnich stacjach uzdatniania wody.
The principles of operation of a typical system for disinfectant production from sodium chlorite by the electrolytic method are described. The advantages and and disadvantages of applying "electrochlorination" to water disinfection are compared with those of using gas chlorine or sodium hypochloride as disinfectants (apopular approach widely practiced in water treatment plants). The benefits from utilizing the disinfectant at the source of origin can be itemized as follows: elimination of environmental hazards, abatement of corrosion problems, reduction in the amount of THM and HAA5 in the treated water (when use is made of a mixture of oxidizers generated in the Miox system), more effective destruction of mocroorganisms in the water, and efficient removal of the biofilm from the water-pipe network. Economic considerations have shown that the production of sodium hypochlorite and a MIOX mixture by the electrolytic method for water disinfection is cost-effective primarily in small and medium-size water treatment plants.
Źródło:
Ochrona Środowiska; 2003, R. 25, nr 4, 4; 23-26
1230-6169
Pojawia się w:
Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Dezynfekcja wody dwutlenkiem chloru-doświadczenia Zakładu Wodociągu Praskiego
Disinfection of drinking water with chlorine dioxide:a case study
Autorzy:
Mossakowska, A.
Powiązania:
https://bibliotekanauki.pl/articles/236979.pdf
Data publikacji:
1999
Wydawca:
Polskie Zrzeszenie Inżynierów i Techników Sanitarnych
Tematy:
dwutlenek chloru
Zakład Wodociągu Praskiego
dezynfekcja wody
Opis:
The object under study is the Waterworks of Warsaw. The water to be treated comesfrom the Yistula River. Recently use has been made of chlorine dioxide (generated in situ) for disinfection ofdrinking water. The paper describes in detail the on-site generation of CIO2, the CIO2 dosing system, and the quality ofthe water at the outletfrom the plant and in the network.Two methodsof disinfection werestudied-one involved chlorine dioxide alone, the other one a ClO2-Cl2 mixture. The yield of THM formation was found to depend on the proportion of chlorine involved in the disinfection process. The criteria for the determination ofthe CIO2 demand were proposed.
Źródło:
Ochrona Środowiska; 1999, 4; 49-51
1230-6169
Pojawia się w:
Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Znaczenie hydrodynamiki komór reakcji w procesie ozonowania wody
Role of hydrodynamic behaviour of contact columns in the ozonation process
Autorzy:
Olsińska, U.
Kuś, K.
Powiązania:
https://bibliotekanauki.pl/articles/237664.pdf
Data publikacji:
2001
Wydawca:
Polskie Zrzeszenie Inżynierów i Techników Sanitarnych
Tematy:
dezynfekcja wody
ozonowanie wody
hydrodynamika
badania hydrauliczne
komory kontaktowe
Opis:
The efficiency of the ozonation process is affected by the following major factors: gas-liquid dispersion (interfacial gas-liquid surface) and contact time, as well as some other parameters influencing the mass transfer rate and the kinetics of chemical and biochemical reactions. And this is why the intensity of mixing in the dissolution system becomes a key issue. Mixing intensity depends on the following operating parameters: volumetric liquid flow rate, volumetric gas flow rate and reactor geometry. The primary objective of the study reported in the present paper was to analyze the problem of how the said parameters influence the hydraulic behavior of the contact column. Tracer studies were carried out with a contact column in a co- and counter-current gas-to-water-flow system. It was found that the presence of the gas phase changed the behavior of the reaction column - basically due to the increase of mixing intensity. When the intensity of mixing increases and the quality of the oxidant dose cannot be changed, there will be a concomitant increase in the yield of the oxidation/disinfection reactions, which produce undesirable intermediates. This increase is paralleled by the shortening of both mean residence time and t10, which deteriorates the efficiency of disinfection. The results of the study evidence that the selection of the plug flow reactor is a prerequisite of an effective ozone use for microorganism inactivation.
Źródło:
Ochrona Środowiska; 2001, 2; 15-20
1230-6169
Pojawia się w:
Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The possibilities of using constructed wetlands to disinfect water
Badania nad możliwością zastosowania złóż hydrofitowych do wstępnej dezynfekcji wody pitnej
Autorzy:
Włodyka-Bergier, A.
Dziugieł, M.
Bergier, T.
Powiązania:
https://bibliotekanauki.pl/articles/385801.pdf
Data publikacji:
2010
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie. Wydawnictwo AGH
Tematy:
dezynfekcja wody
złoża hydrofitowe
water disinfection
constructed wetlands
Opis:
This paper presents the results of the research on the possibilities to use constructed wetlands for water disinfection. The research was conducted in the laboratory conditions on the model beds filled with gravel and sand, with and without plants. During the experiments the influence of the flow rate and the initial concentration of microorganisms on the disinfection effectiveness were examined for culturable microorganisms incubated at 36°C and 22°C. The possibilities to remove bacteria from coli group, thermotolerant coli bacteria, Escherichia coli was also examinated. The research showed the high usefulness of the constructed wetlands for the water disinfection.
W artykule przedstawiono wyniki badań nad możliwością zastosowania złóż hydrofitowych do dezynfekcji wody pitnej. Badania przeprowadzono w warunkach laboratoryjnych na modelowych złożach z wypełnieniem żwirowym i piaskowym, z roślinnością i bez roślinności. Podczas eksperymentów badano wpływ prędkości przepływu i początkowej zawartości mikroorganizmów na efektywność usuwania ogólnej liczby mikroorganizmów inkubowanych w temperaturze 36°C i 22°C. Zbadano również możliwość usuwania bakterii z grupy coli, bakterii coli termotolerancyjnych oraz bakterii Escherichia coli. Badania wykazały dużą przydatność złóż hydrofitowych do wstępnej dezynfekcji wody.
Źródło:
Geomatics and Environmental Engineering; 2010, 4, 3; 87-93
1898-1135
Pojawia się w:
Geomatics and Environmental Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Ocena możliwości zastosowania ultradźwięków do wspomagania koagulacji domieszek wody
On the utility of ultrasounds as coagulant aid in water treatment
Autorzy:
Bień, J.
Stępniak, L.
Powiązania:
https://bibliotekanauki.pl/articles/237001.pdf
Data publikacji:
2000
Wydawca:
Polskie Zrzeszenie Inżynierów i Techników Sanitarnych
Tematy:
uzdatnianie wody
dezynfekcja wody
metody koagulacji
koagulacja siarczanem glinu
ultradźwięki
pole ultradźwiękowe
mętność wody
Opis:
The experiments were carried out on natural water samples which were subject to alum coagulation in an ultrasounds + coagulant (Al2(S04)3x18H20) system. The ultrasonic field made use of in the study had a frequency of 22 kHz and a vibration amplitude of 8 žm, the time of exposure ranging from 1 to 5 minutes. The findings of the study can be noticeably upgraded by the use of ultrasounds; a 5-minute exposure to the ultrasonic field brought about the maximum efficiency of turbidity removal but, in terms of cost-effectiveness, a one-minute exposure was sufficient to produce a turbidity removal efficiency which was only slightly below the maximum value; the contribution of ultrasounds to the treatment effect was the most favourable when the seta potential value tended to zero.
Źródło:
Ochrona Środowiska; 2000, 3; 17-19
1230-6169
Pojawia się w:
Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Bakteryjne wskaźniki zanieczyszczenia wody w pływalniach z uwzględnieniem różnych sposobów dezynfekcji wody
Bacterial indices of water pollution in swimming pools with reference to various methods of water disinfection
Autorzy:
Haman, S.
Powiązania:
https://bibliotekanauki.pl/articles/874596.pdf
Data publikacji:
1975
Wydawca:
Narodowy Instytut Zdrowia Publicznego. Państwowy Zakład Higieny
Tematy:
zanieczyszczenia wod
plywalnie
dezynfekcja wody
bakterie
srodki dezynfekcyjne
zanieczyszczenia bakteryjne
opornosc
Źródło:
Roczniki Państwowego Zakładu Higieny; 1975, 26, 6
0035-7715
Pojawia się w:
Roczniki Państwowego Zakładu Higieny
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wykorzystanie dwutlenku chloru do dezynfekcji i stabilizacji mikrobiologicznej wody na przykładzie sieci wodociągowej w Nowym Targu
Chlorine Dioxide as a Disinfectant Stabilizing Potable Water: A Case Study
Autorzy:
Lipiak, D.
Kniotek, W.
Suchański, W.
Powiązania:
https://bibliotekanauki.pl/articles/236420.pdf
Data publikacji:
2003
Wydawca:
Polskie Zrzeszenie Inżynierów i Techników Sanitarnych
Tematy:
Clostridium perfringens
dwutlenek chloru
dezynfekcja wody
chlorine dioxide
water disinfection
Opis:
Dwutlenek chloru należy do najbardziej trwałych środków dezynfekcyjnych i oprócz skutecznej dezynfekcji znacznie ogranicza dalszy rozwój bakterii w sieci wodociągowej, a jednocześnie ogranicza ilość powstających produktów ubocznych. Dwutlenek chloru jest bardzo dobrym środkiem do mikrobiologicznej kontroli sieci wodociągowych, zwłaszcza tych, które są narażone na skażenie ze względu na specyfikę ujęć wody. Dwutlenek chloru ma ponadto zdolność do zmniejszania warstwy osadów biologicznych w przewodach wodociągowych (biofilm) oraz znacznie lepiej ogranicza w nich obecność żywych bakterii w porównaniu do chloru. W pracy omówiono wykorzystanie dwutlenku chloru do dezynfekcji i kontroli mikrobiologicznej jakości wody do picia, ze szczególnym uwzględnieniem większości występujących w niej zanieczyszczeń bakteryjnych, a zwłaszcza form przetrwalnikujących. Omówiono skuteczne zastosowanie dwutlenku chloru do uzdatniania wody z ujęcia w Szaflarach, zaopatrującego Nowy Targ w wodę do picia, podczas skażenia wód Białego Dunajca bakteriami Clostridium perfringens.
The performance of chlorine dioxide as a biocide was investigated in the water-pipe network of Nowy Targ, which is a municipality of 34 thousands inhabitants in the south of Poland. This disinfectant enables an efficient control of protozoa, bacteria, viruses, algae and resting spores that might be present in the water-pipe network, and in many instances is more efficient then chlorine, UV, chloramines or ozone. The object under study is fed by the riverine water intake (Biały Dunajec) in Szaflary. The application of chlorine dioxide as a disinfectant to the treatment of potable water for the city of Nowy Targ was found to be effective even during episodes of riverine water contamination with the bacterial strain Clostridium perfringens.
Źródło:
Ochrona Środowiska; 2003, R. 25, nr 3, 3; 61-64
1230-6169
Pojawia się w:
Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Ocena sanitarno-higieniczna pływalni bydgoskich na podstawie badań jakości wody. Cz. I. Badania mikrobiologiczne
Evaluation of the sanitary and hygienic state of the swimming pools in Bydgoszcz based on investigations of water quality. Part I. Microbiological investigations
Sanitarno-gigienicheskaja ocenka plavatel’nykh bassejjnov v Bydgoshi na osnovanii issledovanijj kachestva vody. CH. I. Mikrobiologicheskie issledovanija
Autorzy:
Doboszyńska, B.
Dymek, D.
Sienkiewicz, J.
Powiązania:
https://bibliotekanauki.pl/articles/876168.pdf
Data publikacji:
1985
Wydawca:
Narodowy Instytut Zdrowia Publicznego. Państwowy Zakład Higieny
Tematy:
ocena sanitarna
plywalnie
jakosc wody
badania podstawowe
Bydgoszcz
dezynfekcja wody
wyniki badan
Źródło:
Roczniki Państwowego Zakładu Higieny; 1985, 36, 1
0035-7715
Pojawia się w:
Roczniki Państwowego Zakładu Higieny
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies