Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "dewatering pumps" wg kryterium: Temat


Wyświetlanie 1-4 z 4
Tytuł:
Energy consumption analysis of the main dewatering pumps in underground mines
Analiza energochłonności pomp głównego odwadniania kopalń podziemnych
Autorzy:
Michlowicz, Edward
Wojciechowski, Jerzy
Powiązania:
https://bibliotekanauki.pl/articles/2106524.pdf
Data publikacji:
2021
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie. Wydawnictwo AGH
Tematy:
dewatering pumps
energy consumption
pumping costs
charakterystyki pomp
energochłonność
koszty pompowania
Opis:
Mine dewatering is one of the main tasks and problems in the mining sector which do not affect output directly but are necessary for correct mine operations. The main dewatering pumps are located at various levels, but the pumping head is always a few hundred metres underground. The number and operating time of the pumps depends on the water inflow and are specified in the applicable regulations. Due to the capacity and required head, the power demand may well be in excess of 1 MW. Consequently, the correct use of main dewatering pumps, at low energy consumption, is a basic condition of limiting water pumping costs. The analysed pumping station is located at level 500, is equipped with ten Q = 500 m3 /h (0.139 m3 /s) OW-250/8 pumps. The operating time of most pumps exceeds 20 000 h and the energy consumption is from 2.17 to 2.67 kWh/m3 of pumped water. The analysis results and the energy consumption ratios have been compared with the data for new pumps which operate at data sheet parameters (efficiency). This was the basis to evaluate the impact of exceeding the time between repairs on operating parameters and the increase in the operating costs of the main dewatering pumps.
Odwadnianie kopalń należy do głównych zadań i problemów eksploatacji w górnictwie, które nie wpływają bezpośrednio na wydobycie, jednak stanowi nieodzowną działalność dla prawidłowej eksploatacji kopalń. Pompownie głównego odwadniana w kopalniach znajdują się na różnych poziomach, ale zawsze wysokość pompowania wynosi kilkaset metrów. Liczba pomp oraz czas ich pracy zależą od wielkości dopływów wód i jednoznacznie wynikają z przepisów. Ze względu na wydajność i wymaganą wysokość podnoszenia zapotrzebowanie mocy może znacznie przekraczać 1 MW. Dlatego prawidłowa eksploatacja pomp głównego odwadniania, przy niskiej energochłonności, stanowi podstawowy warunek ograniczenia kosztów wypompowania wody. Analizowana pompownia znajduje się na poziomie 500, jest wyposażona w dziesięć pomp OW-250/8 o wydajności Q = 500 m3 /h (0,139 m3 /s). Czas eksploatacji większości pomp przekracza 20 tysięcy godzin, co powoduje, że energochłonność wynosi od 2,17 do 2,67 kWh/m3 wypompowanej wody. Wyniki przeprowadzonej analizy eksploatacyjnej i wartości wskaźników określających energochłonność odniesiono do wskaźników dla nowych pomp pracujących z parametrami (sprawność) katalogowymi. Na tej podstawie oceniono wpływ przekroczenia czasów między remontami na parametry eksploatacyjne i zwiększenie kosztów eksploatacji pomp głównego odwadniania.
Źródło:
Mining – Informatics, Automation and Electrical Engineering; 2021, 59, 2; 47-54
2450-7326
2449-6421
Pojawia się w:
Mining – Informatics, Automation and Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analiza energochłonności pomp głównego odwadniania kopalń podziemnych
Energy consumption analysis of the main dewatering pumps in underground mines
Autorzy:
Michlowicz, Edward
Wojciechowski, Jerzy
Powiązania:
https://bibliotekanauki.pl/articles/2134397.pdf
Data publikacji:
2021
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie. Wydawnictwo AGH
Tematy:
charakterystyki pomp
energochłonność
koszty pompowania
dewatering pumps
energy consumption
pumping costs
Opis:
Odwadnianie kopalń należy do głównych zadań i problemów eksploatacji w górnictwie, które nie wpływają bezpośrednio na wydobycie, jednak stanowi nieodzowną działalność dla prawidłowej eksploatacji kopalń. Pompownie głównego odwadniana w kopalniach znajdują się na różnych poziomach, ale zawsze wysokość pompowania wynosi kilkaset metrów. Liczba pomp oraz czas ich pracy zależą od wielkości dopływów wód i jednoznacznie wynikają z przepisów. Ze względu na wydajność i wymaganą wysokość podnoszenia zapotrzebowanie mocy może znacznie przekraczać 1 MW. Dlatego prawidłowa eksploatacja pomp głównego odwadniania, przy niskiej energochłonności, stanowi podstawowy warunek ograniczenia kosztów wypompowania wody. Analizowana pompownia znajduje się na poziomie 500, jest wyposażona w dziesięć pomp OW-250/8 o wydajności Q = 500 m3 /h (0,139 m3 /s). Czas eksploatacji większości pomp przekracza 20 tysięcy godzin, co powoduje, że energochłonność wynosi od 2,17 do 2,67 kWh/m3 wypompowanej wody. Wyniki przeprowadzonej analizy eksploatacyjnej i wartości wskaźników określających energochłonność odniesiono do wskaźników dla nowych pomp pracujących z parametrami (sprawność) katalogowymi. Na tej podstawie oceniono wpływ przekroczenia czasów między remontami na parametry eksploatacyjne i zwiększenie kosztów eksploatacji pomp głównego odwadniania.
Mine dewatering is one of the main tasks and problems in the mining sector which do not affect output directly but are necessary for correct mine operations. The main dewatering pumps are located at various levels, but the pumping head is always a few hundred metres underground. The number and operating time of the pumps depends on the water inflow and are specified in the applicable regulations. Due to the capacity and required head, the power demand may well be in excess of 1 MW. Consequently, the correct use of main dewatering pumps, at low energy consumption, is a basic condition of limiting water pumping costs. The analysed pumping station is located at level 500, is equipped with ten Q = 500 m3 /h (0.139 m3 /s) OW-250/8 pumps. The operating time of most pumps exceeds 20 000 h and the energy consumption is from 2.17 to 2.67 kWh/m3 of pumped water. The analysis results and the energy consumption ratios have been compared with the data for new pumps which operate at data sheet parameters (efficiency). This was the basis to evaluate the impact of exceeding the time between repairs on operating parameters and the increase in the operating costs of the main dewatering pumps.
Źródło:
Mining – Informatics, Automation and Electrical Engineering; 2021, 59, 2; 55-62
2450-7326
2449-6421
Pojawia się w:
Mining – Informatics, Automation and Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analiza kosztów eksploatacji systemu głównego odwadniania kopalni węgla kamiennego
Analysis of operating costs of the main coal mine dewatering system
Autorzy:
Korbiel, Tomasz
Wojciechowski, Jerzy
Powiązania:
https://bibliotekanauki.pl/articles/1841099.pdf
Data publikacji:
2019
Wydawca:
STE GROUP
Tematy:
eksploatacja pomp
główne odwadnianie
redukcja kosztów
operation of pumps
main dewatering
cost reduction
Opis:
System głównego odwadniania kopalni jest elementem niezbędnym w eksploatacji podziemnych zakładów górniczych. System ten składa się z wielu elementów takich jak kanały i chodniki wodne, zbiorniki podziemie pompy z napędem oraz rurociągi tłoczne. Działanie tego systemu jest uniezależnione od aktualnego wydobycia, stanowiąc dla kopalni stały koszt utrzymania. W zależności od głębokości kopalni oraz średniego napływu wody na koszt ten składają się koszt energii elektrycznej zasilającej pompy, koszt amortyzacji urządzeń, koszt obsługi oraz koszty ewentualnej utylizacji wody wraz z opłatami środowiskowymi. W artykule przedstawiono rozważania dotyczące ograniczenia kosztów funkcjonowania odwadniania głównego poprzez odpowiednią eksploatację urządzeń oraz odpowiednią politykę remontową. Przedstawione wyniki oparte zostały o rzeczywistą analizę funkcjonowania systemu odwadniania jednej z polskich kopalń.
The main mine dewatering system is an essential element in the exploitation of underground mining plants. The system consists of many elements such as water channels and water walkways, underground tanks, powered pumps, and discharge pipelines. The operation of this system is independent of the current extraction, constituting a fixed cost of maintenance for the mine. Depending on the depth of the mine and the average inflow of water, this cost consists of the cost of electricity supplying the pump, the cost of depreciation of equipment, the cost of service and the costs of possible water disposal along with environmental charges. The article presents considerations regarding the reduction of main drainage operation costs through appropriate equipment operation and appropriate repair policy. The presented results are based on a real analysis of the functioning of the drainage system of one of the Polish mines.
Źródło:
Systemy Wspomagania w Inżynierii Produkcji; 2019, 8, 1; 413-419
2391-9361
Pojawia się w:
Systemy Wspomagania w Inżynierii Produkcji
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Economic aspects relating to machine operations on a mine main drainage system
Autorzy:
Korbiel, Tomasz
Czerwińska-Lubszczyk, Agnieszka
Brodny, Jarosław
Czerwiński, Stefan
Powiązania:
https://bibliotekanauki.pl/articles/24202574.pdf
Data publikacji:
2022
Wydawca:
Akademia Morska w Szczecinie. Wydawnictwo AMSz
Tematy:
coal mine dewatering
optimization of pumps operation
machine safety and reliability
maintenance of water pumps
economy of an underground coal mine
device diagnostics
Opis:
This article presents an economic analysis of the exploitation of the main mine drainage according to the condition of machines. The study is based on actual operating data obtained during the operation of an underground hard coal mine. Through the selection of state estimators, appropriate sensory systems, as well as a long-term economic approach, operating procedures were developed that allowed for the introduction of significant financial savings. Operating costs are reduced by lowering energy consumption and reducing the costs of current repairs and spare parts. In addition to the classic approach to monitoring the state of a machine, based on the observation of residual processes, a global coefficient, referred to as unit energy consumption, has been proposed. Thanks to this, the operation of the machine occurs not only on the basis of its current dynamic state, but also due to the control processes of the machine’s operation. Moreover, the article refers to the area related to water safety and the reliability of the pumping station.
Źródło:
Zeszyty Naukowe Akademii Morskiej w Szczecinie; 2022, 72 (144); 122--130
1733-8670
2392-0378
Pojawia się w:
Zeszyty Naukowe Akademii Morskiej w Szczecinie
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-4 z 4

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies