Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "dental composite" wg kryterium: Temat


Tytuł:
Influence of the light source and curing parameters on microhardness of a silorane-based dental composite material
Autorzy:
Malara, P.
Czech, Z.
Świderski, W.
Powiązania:
https://bibliotekanauki.pl/articles/356555.pdf
Data publikacji:
2016
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
dental composite material
light-curing
silorane
microhardness
Opis:
The aim of the study was to determine the influence of the light source and the light-curing parameters (the distance of the material from the light source and time of light-curing) on microhardness of Flitek Silorane dental composite material. Standardized samples of Filtek Silorane material were cured using two types of Light Curing Units (LCUs) - halogen and LED. The distance of the light source and time of curing differed between samples. The Knoops microhardness was tested using microhardness tester Micromet 5103. Using LED light curing unit allowed to achieve significantly higher microhardness of silorane-based dental material Filtek Silorane than using halogen light curing unit. Decreasing the distance from the light source to the surface of silorane-based material Filtek Silorane improved its microhardness. A prolonged curing time could compensate the drop in microhardness of Filtek Silorane material resulting from an increased distance from the light source to the surface of the material only in a limited range of intervals.
Źródło:
Archives of Metallurgy and Materials; 2016, 61, 3; 1331-1336
1733-3490
Pojawia się w:
Archives of Metallurgy and Materials
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Polymerization shrinkage of resin mixtures used in dental composites
Autorzy:
Pałka, Krzysztof
Janiczuk, Patrycja
Kleczewska, Joanna
Powiązania:
https://bibliotekanauki.pl/articles/286221.pdf
Data publikacji:
2020
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie. Polskie Towarzystwo Biominerałów
Tematy:
polymer blends
volumetric shrinkage
dimetacrylates
dental composite
Opis:
Polymerization of dental composites generates shrinkage in the matrix resulting in numerous clinical problems. The influence of the most commonly used resins on the shrinkage process has not been thoroughly examined so far in the literature. The purpose of this work is to determine the effect of the resin mixture compositions on the volumetric polymerization shrinkage. The mixtures used in the tests were pre-pared in specific weight proportions to determine the influence of particular monomers, such as Bis-GMA, Bis-EMA, UDMA, and TEGDMA. The shrinkage measurements were performed using the self-designed video-imaging device. The studies showed that the shrinkage decreased in opposite to the Bis-GMA concentration in the mixture with the simultaneous decrease in the Bis-EMA content. The shrinkage value decreased in opposite to the molecular weight only for some monomers and compositions. Bis-EMA resin as a flexible monomer achieved the lower shrinkage values than UDMA, and the highest shrinkage values, above 6%, were achieved by compositions with the 14wt% content of Bis-GMA. Regarding the shrinkage, the most optimal composition was 56wt% Bis-GMA with the addition of Bis-EMA (24wt%) and TEGDMA (20wt%). The obtained shrinkage value was 4.73%.
Źródło:
Engineering of Biomaterials; 2020, 23, 154; 16-21
1429-7248
Pojawia się w:
Engineering of Biomaterials
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Polymerization shrinkage of resin mixtures used in dental composites
Autorzy:
Pałka, Krzysztof
Janiczuk, Patrycja
Kleczewska, Joanna
Powiązania:
https://bibliotekanauki.pl/articles/1844982.pdf
Data publikacji:
2020
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie. Polskie Towarzystwo Biominerałów
Tematy:
polymer blends
volumetric shrinkage
dimetacrylates
dental composite
Opis:
Polymerization of dental composites generates shrinkage in the matrix resulting in numerous clinical problems. The influence of the most commonly used resins on the shrinkage process has not been thoroughly examined so far in the literature. The purpose of this work is to determine the effect of the resin mixture compositions on the volumetric polymerization shrinkage. The mixtures used in the tests were pre-pared in specific weight proportions to determine the influence of particular monomers, such as Bis-GMA, Bis-EMA, UDMA, and TEGDMA. The shrinkage measurements were performed using the self-designed video-imaging device. The studies showed that the shrinkage decreased in opposite to the Bis-GMA concentration in the mixture with the simultaneous decrease in the Bis-EMA content. The shrinkage value decreased in opposite to the molecular weight only for some monomers and compositions. Bis-EMA resin as a flexible monomer achieved the lower shrinkage values than UDMA, and the highest shrinkage values, above 6%, were achieved by compositions with the 14wt% content of Bis-GMA. Regarding the shrinkage, the most optimal composition was 56wt% Bis-GMA with the addition of Bis-EMA (24wt%) and TEGDMA (20wt%). The obtained shrinkage value was 4.73%.
Źródło:
Engineering of Biomaterials; 2020, 23, 154; 16-21
1429-7248
Pojawia się w:
Engineering of Biomaterials
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Microstructure and surface free energy of light-cured dental composites after their modification with liquid rubber
Autorzy:
Sowa, Monika
Przekora, Agata
Pałka, Krzysztof
Powiązania:
https://bibliotekanauki.pl/articles/2058402.pdf
Data publikacji:
2022
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie. Polskie Towarzystwo Biominerałów
Tematy:
dental composite
solubility
liquid rubber
wettability
surface free energy
Opis:
The use of liquid rubber as a component of light-cured dental composites is one of the methods of increasing their fracture toughness. It also reduces polymerization shrinkage and offers the potential to lower water sorption. The aim of the study was to evaluate the miscibility of liquid rubber in composite matrix resins as well as changes in the wettability and surface free energy (SFE) values of commercial lightcuring composites after their modification with liquid rubber. The research materials were Flow Art and Boston (Arkona) light-cured composites and resin mixtures used in their production. Liquid rubber Hypro 2000X168LC VTB (Huntsman Int.) was used as a modifier. The solubility of liquid rubber was assessed under light microscopy. The contact angle and SFE measurements were made on a DSA30 goniometer (Kruss) using water and diiodomethane. It was found that the liquid rubber solubility depended mainly on the viscosity of the resin, which was related to the amount of BisGMA. The resulting mixture showed good temporal stability without larger domains. The curing process released the liquid rubber as a separate phase formed as spherical domains. The morphology of these domains was homogeneous and their size did not exceed 50 µm in diameter. The presence of liquid rubber in modified composites increased their hydrophobicity and reduced the surface free energy value. The obtained properties might help to reduce the formation of bacterial biofilm on dental fillings.
Źródło:
Engineering of Biomaterials; 2022, 25, 164; 9--15
1429-7248
Pojawia się w:
Engineering of Biomaterials
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Method of evaluation of degradation of bio-mechanical tooth-composite filling system
Metoda oceny degradacji systemu biomechanicznego ząb - wypełnienie kompozytowe
Autorzy:
Niewczas, A.
Pieniak, D.
Niewczas, A. M.
Powiązania:
https://bibliotekanauki.pl/articles/329600.pdf
Data publikacji:
2010
Wydawca:
Polska Akademia Nauk. Polskie Towarzystwo Diagnostyki Technicznej PAN
Tematy:
niezawodność
test laboratoryjny
kompozyt stomatologiczny
reliability
laboratory test
dental composite
Opis:
This paper describes a method of an enhanced life evaluation of dental fillings based on the observation of the enlargement of the marginal fissure between the filling and hard tissue of the tooth. A width of marginal fissure was considered as the functional parameter of the whole tooth-filling system in the conducted tests. In this study development of the fissure influenced by the cyclic changes of thermal loads was analyzed. The extracted human teeth were used in the tests. In which a model lesions with microhybrid composite fillings were applied. All tests were conducted on the dedicated test stand. After performance of fatigue tests, measurements of the width of marginal fissure were taken by means of SEM electron scanning microscope and optical microscope with computer image analyzer. On this basis a risk of functional unfitness of the tooth-filling system was estimated.
W artykule opisano metodę przyspieszonej oceny trwałości wypełnień stomatologicznych na podstawie obserwacji rozbudowy szczeliny brzeżnej pomiędzy wypełnieniem a twardą tkanką zęba. W warunkach prowadzonych badań jako miarę zdatności czynnościowej całego systemu ząb - wypełnienie przyjęto szerokość szczeliny brzeżnej. Autorzy przeprowadzili analizę rozwoju szczeliny pod wpływem cyklicznie zmiennych obciążeń cieplnych. Do badań wykorzystano usunięte zęby ludzkie. W zębach wypreparowano modelowe ubytki i założono wypełnienia z kompozytu mikrohybrydowego. Badania zostały przeprowadzone na specjalnie opracowanym stanowisku badawczym. Po wykonaniu testów zmęczeniowych przeprowadzano pomiary szerokości badanej szczeliny brzeżnej, wykorzystując elektronowy mikroskop skaningowy SEM. Na tej podstawie oszacowano ryzyko niezdatności użytkowej układu ząb - wypełnienie.
Źródło:
Diagnostyka; 2010, 2(54); 51-58
1641-6414
2449-5220
Pojawia się w:
Diagnostyka
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Światłoutwardzalne kompozyty zawierające akrylowane żywice wielofunkcyjne : skrócony przegląd literaturowy
Light curable composites containing multifunctional acrylated resins : short literature review
Autorzy:
Czech, Z.
Minciel, E.
Powiązania:
https://bibliotekanauki.pl/articles/270972.pdf
Data publikacji:
2015
Wydawca:
Centralny Ośrodek Badawczo-Rozwojowy Aparatury Badawczej i Dydaktycznej, COBRABiD
Tematy:
stomatologiczne materiały kompozytowe
żywica akrylanowa
fotoutwardzanie
dental composite materials
acrylic resins
photocuring
Opis:
Bezpośredni proces fotoutwardzania kompozytów stomatologicznych zawierających akrylowane żywice wielofunkcyjne jest możliwy przy zastosowaniu światła widzialnego lub promieniowania UV z zakresu UV-A. Światłoutwardzalne żywice zawierają w swojej strukturze wiązania podwójne, których odległość od siebie ma wpływ na wielkość efektu skurczu polimeryzacyjnego. Proces utwardzania zależy również od doboru odpowiedniego fotoinicjatora, który wpływa na szybkość penetracji kompozytu stomatologicznego wiązką światła.
Directly curing process of dental composites is possible only by using of synthetic acrylic resins curable with visible light or UV-A radiation. Light curable resins contain in their structure a large number of double bonds which distance between double bonds is dependent on the effect of the polymerization shrinkage. The curing process also depends on select of the suitable photoinitiator which affects on the speed of the dental composite penetration using light beam.
Źródło:
Aparatura Badawcza i Dydaktyczna; 2015, 20, 4; 270-275
2392-1765
Pojawia się w:
Aparatura Badawcza i Dydaktyczna
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Badania właściwości mechanicznych światłoutwardzalnych kompozytów na bazie wielofunkcyjnych żywic akrylanowych
Light curable composites based on multifunctional acrylic resins
Autorzy:
Czech, Z.
Minciel, E.
Powiązania:
https://bibliotekanauki.pl/articles/271151.pdf
Data publikacji:
2016
Wydawca:
Centralny Ośrodek Badawczo-Rozwojowy Aparatury Badawczej i Dydaktycznej, COBRABiD
Tematy:
stomatologiczne materiały kompozytowe
żywica akrylanowa
fotoutwardzanie
dental composite materials
acrylic resins
photocuring
Opis:
Bezpośredni proces fotoutwardzania wypełnień stomatologicznych jest możliwy jedynie przy zastosowaniu syntetycznych żywic akrylanowych utwardzalnych za pomocą światła widzialnego lub promieniowania UV z zakresu UV-A. Fotoutwardzalne żywice zawierają w swojej strukturze wiązania podwójne, których odległość od siebie ma wpływ na wielkość efektu skurczu polimeryzacyjnego. Proces utwardzania zależy również od doboru odpowiedniego fotoinicjatora, który wpływa na szybkość penetracji kompozytu stomatologicznego wiązką światła.
Directly curing process of dental composites is possible only by using of synthetic acrylic resins curable with visible light or UV-A radiation. Photocurable resins contain in their structure a large number of double bonds which distance between double bonds is dependent on the effect of the polymerization shrinkage. The curing process also depends on select of the suitable photoinitiator which affects on the speed of the dental composite penetration using light beam.
Źródło:
Aparatura Badawcza i Dydaktyczna; 2016, 21, 1; 10-15
2392-1765
Pojawia się w:
Aparatura Badawcza i Dydaktyczna
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Charakterystyka kompozytowych materiałów stomatologicznych stosowanych w gabinetowych systemach CAD/CAM
Characteristic of composite dental materials used with CAD/CAM chairside systems
Autorzy:
Rogula, Jakub
Kuźniar-Folwarczny, Agnieszka
Sulewski, Mikołaj
Błaszczyk, Anna
Sulewska, Agnieszka
Kosior, Piotr
Dobrzyński, Maciej
Powiązania:
https://bibliotekanauki.pl/articles/985825.pdf
Data publikacji:
2020
Wydawca:
Indygo Zahir Media
Tematy:
CAD/CAM
uzupełnienia kompozytowe
kompozyt stomatologiczny
systemy gabinetowe
materiały dentystyczne
chairside systems
dental materials
composite restoration
dental composite
Opis:
Praca zawiera charakterystykę materiałów kompozytowych i hybrydowych stosowanych w gabinetowych systemach CAD/ CAM, jak również opis procedury zabiegowej podczas leczenia pacjenta z zastosowaniem jednego z nich. Materiały kompozytowe stosowane powszechnie do odbudowy bezpośredniej zębów posiadają wady, które zostały wyeliminowane w prefabrykowanych bloczkach zdatnych do obróbki skrawaniem. Frezowanie pracy ostatecznej podczas tej samej wizyty umożliwia uzyskanie uzupełnienia o lepszych właściwościach fizyko-chemicznych, lepszej estetyce i pozbawionego takich wad jak skurcz polimeryzacyjny, w podobnym czasie, co standardowe leczenie zachowawcze.
The work contains the characteristics of composite and hybrid materials used in the office CAD/CAM systems, as well as a description of the procedure during treatment of the patient using one of them. Composite materials commonly used for direct tooth reconstruction have defects that have been eliminated in prefabricated blocks suitable for machining. Milling the final work during the same visit makes it possible to obtain a restoration with better physico-chemical properties, better aesthetics and free of defects such as polymerization shrinkage. All that is at a similar time as standard conservative treatment.
Źródło:
Inżynier i Fizyk Medyczny; 2020, 9, 1; 57-61
2300-1410
Pojawia się w:
Inżynier i Fizyk Medyczny
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wpływ zmęczenia cieplnego oraz starzenia na mikrotwardość kompozytów polimerowo - ceramicznych do zastosowań biomedycznych
Influence of thermal fatigue and ageing on the microhardness of polymer-ceramic composites for biomedical applications
Autorzy:
Pieniak, D.
Niewczas, A. M.
Kordos, P.
Powiązania:
https://bibliotekanauki.pl/articles/1366276.pdf
Data publikacji:
2012
Wydawca:
Polska Akademia Nauk. Polskie Naukowo-Techniczne Towarzystwo Eksploatacyjne PAN
Tematy:
zmęczenie cieplne
starzenie
mikrotwardość
kompozytowe wypełnienia stomatologiczne
thermal fatigue
ageing
microhardness
dental composite fillings
Opis:
Badania prezentowane w niniejszej publikacji dotyczyły kompozytów polimerowo-ceramicznych stosowanych w stomatologii zachowawczej. Celem pracy była porównawcza ocena wpływu długotrwałego oddziaływania wilgotnego środowiska oraz cyklicznych obciążeń cieplnych na mikrotwardość nowego kompozytu bazującego na siloranach oraz dwóch tradycyjnych kompozytów bazujących na związkach metakrylanu. Próbki z kompozytów poddano oddziaływaniu środowiska soli fizjologicznej o cyklicznie zmiennych temperaturach (5°C i 65°C) wykorzystując specjalny symulator szoków termicznych. Wykonywano pomiary mikrotwardości metodą Vickersa przed rozpoczęciem testu zmęczenia cieplnego oraz po serii 4000 cykli termicznych. Wykazano, że w przeciwieństwie do tradycyjnych kompozytów stomatologicznych mikrotwardość kompozytu bazującego na siloranach nie zmniejsza się pod wpływem cyklicznego oddziaływania szoków termicznych odpowiadających warunkom fizjologicznym jamy ustnej. W warunkach przeprowadzonych badań stwierdzono nieznaczny wzrost tej mikrotwardości. Przeprowadzono również badania starzeniowe polegające na ocenie mikrotwardości próbek kompozytów przez okres 6 miesięcy. W tym okresie czasu próbki przechowywano w soli fizjologicznej. Pomiary mikrotwardości wykonywano po każdym miesiącu ekspozycji. Wykazano, że długotrwałe oddziaływanie środowiska soli fizjologicznej w warunkach stałej temperatury nie zmienia mikrotwardości żadnego z badanych materiałów.
Studies presented in this paper, concern polymer-ceramic composites applied in the conservative dentistry. The aim of the study was to evaluate a long-term impact of the humid environment and cyclic thermal loads on the microhardness of new silorane-based composites and two methacrylate-based composites. The composite samples were subjected to normal saline environment with cyclically variable temperatures (5°C and 65°C), using a special thermal shock simulator. Microhardness was measured with Vicker's method before the fatigue test and after a series of 4000 thermal cycles. It is known that microhardness of silorane-based composite in opposite to methacrylate-based composites not decrease under the influence of cyclic thermal loads. It was found slight increase of microhardness under conditions of conducted tests. The ageing studies were also conducted consisting in microhardness evaluation of the composite samples in 6 months period. During that time the samples were kept in normal saline. The studies of hardness were carried out after each month of the exposure time. No long-term impact of normal saline environment with constant temperature on the microhardness of the studied materials has been noticed.
Źródło:
Eksploatacja i Niezawodność; 2012, 14, 2; 181-188
1507-2711
Pojawia się w:
Eksploatacja i Niezawodność
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Influence of aging solutions on wear resistance and hardness of selected resin-based dental composites
Autorzy:
Chladek, G.
Basa, K.
Żmudzki, J.
Malara, P.
Nowak, A. J.
Kasperski, J.
Powiązania:
https://bibliotekanauki.pl/articles/306782.pdf
Data publikacji:
2016
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
właściwości
mikrotwardość
kompozyty stomatologiczne
tarcie
test
properties
microhardness
dental composite
friction
wear test
aging solution
Opis:
Purpose: The purpose of this study was to investigate the effect of different plasticizing aging solutions on wear resistance and hardness of selected universal resin-based dental composites. Methods: Three light cured (one nanofilled, two microhybride) and one hybride chemical cured composites were aged at 37 °C for 48 h in distillated water, ethyl alcohol solution or Listerine mouthwash. After aging the microhardness tests were carried out and then tribological tests were performed in the presence of aging solution at 37 °C. During wear testing coefficients of friction were determined. The maximal vertical loss in micrometers was determined with profilometer. Results: Aging in all liquids resulted in a significant decrease in hardness of the test materials, with the largest values obtained successively in ethanol solution, mouthwash and water. The effect of the liquid was dependent on the particular material, but not the type of material (interpreted as the size of filler used). Introduction of mouthwash instead of water or ethanol solution resulted in a significant reduction in the coefficient of friction. The lowest wear resistance was registered after aging in ethanol and for the chemical cured hybrid composite, but the vertical loss was strongly material dependent. Conclusions: The effect of different aging solution, including commercial mouthrinse, on hardness and wear was material dependent, and cannot be deduced from their category or filler loading. There is no simple correlation between hardness of resin-based dental composites and their wear resistance, but softening of particular composites materials during aging leads to the reduction of its wear resistance.
Źródło:
Acta of Bioengineering and Biomechanics; 2016, 18, 3; 43-52
1509-409X
2450-6303
Pojawia się w:
Acta of Bioengineering and Biomechanics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Probabilistic model for flexural strength of dental composites used in modeling reliability of the “tooth-dental composite” system
Probabilistyczny model wytrzymałości na zginanie kompozytów stomatologicznych w zastosowaniu do modelowania niezawodności układów "ząb – kompozyt stomatologiczny"
Autorzy:
Bartnik, G.
Pieniak, D.
Niewczas, A. M.
Marciniak, A.
Powiązania:
https://bibliotekanauki.pl/articles/1365809.pdf
Data publikacji:
2016
Wydawca:
Polska Akademia Nauk. Polskie Naukowo-Techniczne Towarzystwo Eksploatacyjne PAN
Tematy:
probabilistic modeling
reliability of tooth-dental composite system
dental composites
flexural strength
modelowanie probabilistyczne
niezawodność układów ząb-kompozyt stomatologiczny
kompozyty stomatologiczne
wytrzymałość na zginanie
Opis:
In the article the application of Bayesian probabilistic modeling was presented as a way to standardize analytics of measurement results, which completes the operational and procedural standardization of determining the strength of dental composites. The traditional way of conducting studies of strength performed as services and calculations, and which do not refer to previous studies, was changed into an adaptation process of knowledge accumulation in a form of an increasing precise models. Probabilistic flexural strength models were used to create a reliability ranking of studied dental composites. Conceptualization of reliability of a biotechnological system, such as a “tooth-dental composite” required the expansion of the notion of“failure” with random events involving the occurrence of compatibility failure.
W pracy przedstawiono zastosowanie bayesowskiego modelowania probabilistycznego jako sposobu standaryzacji opracowania wyników pomiarów, uzupełniającego standaryzację operatorowo – proceduralną wyznaczania wytrzymałości kompozytów stomatologicznych. Tradycyjny sposób prowadzenia badań wytrzymałościowych, wykonywanych usługowo i obliczeniowo nienawiązujących do badań poprzednich, zmieniono w adaptacyjny proces kumulacji wiedzy w postaci coraz dokładniejszych modeli. Probabilistyczne modele wytrzymałości na zginanie wykorzystano do utworzenia rankingu niezawodnościowego badanych kompozytów stomatologicznych. Konceptualizacja niezawodności układów biotechnologicznych takich jak „ząb – wypełnienie stomatologiczne” wymagała rozszerzenia zakresu pojęcia uszkodzenie o losowe zdarzenia polegające na zaistnieniu niezgodności pomiędzy komponentami układu biotechnologicznego (compability failure).
Źródło:
Eksploatacja i Niezawodność; 2016, 18, 1; 136-141
1507-2711
Pojawia się w:
Eksploatacja i Niezawodność
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Prognozowanie degradacji czynnościowej systemów biomechanicznych na przykładzie układu ząb - wypełnienie kompozytowe
Prognosing of functional degradation of bio-mechanical systems exemplified by the tooth-composite filling system
Autorzy:
Niewczas, A.
Pieniak, D.
Bachanek, T.
Surowska, B.
Bieniaś, J.
Pałka, K.
Powiązania:
https://bibliotekanauki.pl/articles/300996.pdf
Data publikacji:
2010
Wydawca:
Polska Akademia Nauk. Polskie Naukowo-Techniczne Towarzystwo Eksploatacyjne PAN
Tematy:
kompozytowe wypełnienia stomatologiczne
nieszczelność brzeżna
badania przyspieszone
composite dental fillings
marginal untightness
accelerated tests
Opis:
Opisana w niniejszym artykule metoda badań trwałości wypełnień stomatologicznych oparta jest na założeniu, że miarą degradacji systemu wypełnienie - tkanka zęba jest wielkość szczeliny brzeżnej. Szczelina brzeżna powstaje na powierzchni granicznej wypełnienia na skutek skurczu polimeryzacyjnego, a następnie w trakcie fizjologicznego procesu żucia powiększa się na skutek, między innymi, obciążeń mechanicznych i termicznych. Konsekwencją powstawania szczeliny brzeżnej jest zjawisko mikroprzecieku. Mikroprzeciek bakteryjny polega na penetracji mikroorganizmów i ich proliferacji w objętości pomiędzy wypełnieniem a ścianą ubytku. Wynikiem tego zjawiska jest próchnica wtórna wzdłuż granicy wypełnienia. W badaniach wykorzystano zęby ludzkie usunięte z powodów ortodontycznych i chirurgicznych. W zębach przeznaczonych do badań wypreparowano modelowe ubytki oraz założono wypełnienia z kompozytu mikrohybrydowego. Tak przygotowane próbki zębów poddano obciążeniom mechanicznym i termicznym symulującym warunki fizjologiczne na specjalnie opracowanym stanowisku badawczym. Po wykonaniu testu obciążeniowego przeprowadzono pomiary parametrów szczeliny brzeżnej wykorzystując mikroskop optyczny oraz skaningowy mikroskop elektronowy (SEM). Wyniki pomiarów poddano analizie statystycznej a następnie dokonano oceny przewidywanej trwałości układu ząb-wypełnienie. Badania wykazały, że możliwa jest przyśpieszona ocena procesu degradacji wypełnień stomatologicznych w warunkach in vitro. Opracowana metoda może mieć praktyczne zastosowanie, między innymi, w testowaniu nowych materiałów stomatologicznych.
The method of resistance testing of dental materials described in this article is based on the principle that the measurement of the degradation of the filling - tooth tissue system is the size of a marginal fissure. The marginal fissure forms on the bordering surface of the filling as a result of polymer spasm and consequently it expands in the course of physiological process of chewing due to, among others, mechanical and thermal loads. The consequence of marginal fissure formation is the phenomenon of a micro-leak. The bacterial micro-leak deals with the penetration of micro-organisms and their proliferation in volume between the filling and the wall of a defect. This results in secondary caries along the filling border. Human teeth extracted due to orthodontic and surgical reasons were used in the tests. Model defects were prepared in the teeth designated to the tests and micro-hybrid fillings were applied. The specimens prepared in this way were next submitted to mechanical and thermal loads simulating physiological conditions performed on the specially prepared research post. After the performance of the load test, the measurements of the marginal fissure were taken with the use of optical and scanning electron microscope ( SEM ). The results of the measurements were statistically analyzed and the assessment of expected resistance of the tooth-filling system was made. The tests have revealed that it is possible to make the accelerated assessment of the degradation process of dental fillings is possible in in vitro conditions.
Źródło:
Eksploatacja i Niezawodność; 2010, 1; 23-34
1507-2711
Pojawia się w:
Eksploatacja i Niezawodność
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analiza prawdopodobieństwa przetrwania i niezawodności układu ząb-wypełnienie kompozytowe
Analysis of survival probability and reliability of the tooth-composite filling system
Autorzy:
Pieniak, D.
Niewczas, A. M.
Niewczas, A.
Bieniaś, J.
Powiązania:
https://bibliotekanauki.pl/articles/301024.pdf
Data publikacji:
2011
Wydawca:
Polska Akademia Nauk. Polskie Naukowo-Techniczne Towarzystwo Eksploatacyjne PAN
Tematy:
niezawodność
kompozytowe wypełnienie stomatologiczne
symulator żucia
obciążenia mechaniczne
reliability
laboratory tests
composite dental fillings
Opis:
Ocenie niezawodności poddano układ biomechaniczny ząb-wypełnienie kompozytowe (kompozyt polimerowy z mikrowypełniaczem). Próbki zębów z wypełnieniami wykonanymi na powierzchni żującej zębów poddano obciążeniom mechanicznym symulującym warunki środowiska jamy ustnej. Badania przeprowadzono w laboratorium na symulatorze żucia. Miarą zużycia wypełnień była szczelina brzeżna, którą oceniano w przekroju podłużnym zęba wykorzystując mikroskop optyczny oraz na powierzchni żucia, wykorzystując skaningowy mikroskop elektronowy (SEM). Wyniki pomiarów uporządkowano w zależności od strefy pomiaru szczeliny oraz w zależności od liczby cykli zmęczeniowych. Obliczano parametry rozkładu statystycznego rozmiarów geometrycznych szczeliny brzeżnej wykorzystując testy Kolmogorova-Smirnova oraz Shapiro-Wilka. Do oceny różnic wykorzystano analizę wariancji ANOVA oraz test post hoc. Wyznaczono przebieg funkcji niezawodności przyjmując model Weibulla. Oceniono ryzyko uszkodzenia oraz prawdopodobieństwo przetrwania badanego układu.
The bio-mechanical tooth-composite filling system (polymer composite with micro-filler) has been evaluated with respect to its reliability. The tooth specimens with prepared fillings on the tooth chewing surface were submitted to mechanical and thermal loads simulating natural conditions in the oral cavity. The research was carried out in the laboratory scale on the mastication simulator. A marginal fissure width was a measurement of the filling's wear, and it was investigated both in the longitudinal section with the use of optical microscope as well as on the chewing surface with the use of scanning electron microscope (SEM). The results of measurements were grouped according to the zone of the fissure measurement and to the number of fatigue tests performed. Statistical distribution parameters of geometrical size of the marginal fissure were calculated based on the Kolmogorov-Smirnov and Shapiro-Wilk tests. ANOVA variation analysis and post hoc test was used to assess the differences. The reliability function was determined with the use of Weibull model. The risk of damage and survival likelihood was evaluated introducing authors' criterion of the limit state of the tooth - filling system.
Źródło:
Eksploatacja i Niezawodność; 2011, 2; 25-34
1507-2711
Pojawia się w:
Eksploatacja i Niezawodność
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Influence of blenching agents on the mechanical properties and colour of dental restorative nanocomposite
Autorzy:
Adeeb, S.
Chladek, Grzegorz
Powiązania:
https://bibliotekanauki.pl/articles/2175749.pdf
Data publikacji:
2021
Wydawca:
Stowarzyszenie Komputerowej Nauki o Materiałach i Inżynierii Powierzchni w Gliwicach
Tematy:
blenching agents
dental restorative composite
mechanical properties
colour measurement
środki wybielające
kompozyt stomatologiczny do uzupełnień
właściwości mechaniczne
pomiar koloru
Opis:
Purpose: Bleaching agents are commonly used to make the natural dentition look more attractive. Currently, in addition to products from reputable manufacturers, products of not fully known origin are available for purchase. The aim of the study was to investigate whether products of this type have a destructive influence on the mechanical and aesthetic properties of the dental restorative nanocomposite. Design/methodology/approach: Four bleaching agents were used, two recognized brands, and two products were purchased from Chinese websites (their manufacturer is unknown). Two gels and two types of whitening strips were used. One composite nanomaterial was used. Microhardness, diametral tensile strength,, compressive strength and colour measurements were tested. Findings: For some bleaching agents, studies have shown a relatively small effect on mechanical properties and an acceptable effect on colour changes. Regardless of the observed changes, the use of bleaching agents qualified for the experiment should be considered safe for composites. Research limitations/implications: The number of blenching agents used as well as dental composites in this study was limited. In future studies, increasing the number of cycles in the bleaching process should be considered. Practical implications: A popular method of improving the aesthetic properties of teeth is the use of a wide range of blenching agents. Most patients who use teeth whitening procedures are also users of composite fillings. The use of bleaching agents may have a different effect on the mechanical and aesthetic restorative composites. For economic reasons, many people decide to import cheap bleaching agents of unknown or dubious origin via Internet services to perform the bleaching process on their own. In this study, it was investigated whether products of this type have an influence on the mechanical and aesthetic properties of the dental restorative nanocomposite. Originality/value: Until now, no comparison of the safety of the use of bleaching agents of recognized manufacturers and of unknown origin in terms of the effect on composite materials has been presented, despite their high social importance.
Źródło:
Archives of Materials Science and Engineering; 2021, 111, 2; 78--85
1897-2764
Pojawia się w:
Archives of Materials Science and Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wykorzystanie symulatora żucia do badań trwałościowych wypełnień stomatologicznych : [streszczenie]
The use of mastification simulator for durability research of dental fillings : [abstract]
Autorzy:
Hunicz, J.
Niewczas, A.
Kordos, P.
Powiązania:
https://bibliotekanauki.pl/articles/284089.pdf
Data publikacji:
2007
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie. Polskie Towarzystwo Biominerałów
Tematy:
wypełnienia stomatologiczne
symulator żucia
stomatologiczne wypełnienia kompozytowe
szczelina brzeżna
badania zmęczeniowe
dental fillings
mastication simulator
composite dental fillings
marginal crevice
fatigue research
Opis:
We współczesnej stomatologii zachowawczej powszechnie stosowanymi materiałami do wypełnień stałych zębów są kompozyty polimerowe. Dalszy rozwój materiałów na wypełnienia stomatologiczne uzależniony będzie od możliwości poznania procesu degradacji układu wypełnienie-ząb. Dlatego też doskonalenie metod przyspieszonych badań in-vitro wypełnień kompozytowych stanowi wyzwanie dla inżynierów zajmujących się biomateriałami. Trwałość wypełnień stomatologicznych jest ograniczona przez rozwój szczeliny brzeżnej miedzy wypełnieniem a ścianą ubytku. Dotychczasowe badania nie w pełni wyjaśniają problem powstawania szczeliny brzeżnej oraz problem powstawania mikropęknieć w materiale wypełniającym i w twardych tkankach zęba. Dlatego też prace eksperymentalne dotyczące degradacji wypełnień stomatologicznych dostarczają nieocenionych informacji zwiększając wiedzę w tym zakresie. Każdy z wprowadzanych na rynek materiałów stomatologicznych musi spełniać rygorystyczne wymagania dotyczące właściwości mechanicznych i chemicznych. Jednakże potrzebne są szczegółowe badania materiałów w zakresie trwałości całego układu wypełnienie-ząb. Ze względu na długi czas badań klinicznych oraz możliwość narażenia pacjentów na utratę zdrowia, weryfikacja żywotności materiałów do wypełnień stomatologicznych musi odbywać się w warunkach laboratoryjnych. Autorzy pracy zdecydowali się na przeprowadzenie badań trwałościowych wyekstrahowanych zębów ludzkich z wypełnieniami. Do odwzorowania cyklicznych obciążeń mechanicznych zębów wykorzystano symulator żucia. Konstrukcje symulatora oparto na założeniu, że musi on w jak największym stopniu odwzorowywać obciążenia mechaniczne zębów występujące podczas aktu żucia. Symulator składa się z pneumatycznego mechanizmu docisku oraz plotera dwuosiowego napędzanego parą silników krokowych. Jedna z badanych próbek przymocowana jest do mechanizmu suwakowego wykonującego ruchy w kierunku pionowym, natomiast druga znajduje się na ploterze symulującym ruchy żuchwy. Aby zapewnić porównywalny rozkład sił niezależnie od geometrycznych uwarunkowań badanych próbek symulator wyposażony jest w układ pomiarowy pozwalający na określenie wektora siły reakcji współpracujących próbek.
The use of polymer composite dental fillings is nowaday very popular for treatment of dental cavities. Further improvement of materials for teeth treatment will be determined by possibilities of analysis of filling-tooth assembly degradation process. Considering the above, development of accelerated in vitro tests of dental materials poses a challenge for engineers who deal with biomaterials. Durability of dental fillings is limited by the development of marginal crevice between filling and tooth cavity wall. On the base of analysis of publications which deal with polymer composite dental fillings it should be noticed that the problems of marginal crevice and cracks propagation are not fully described. That is why research works considering degradation of dental fillings provide a lot of invaluable data to gain knowledge in this subject. All materials introduced into the market have to fulfill rigorous requirements considering mechanical and chemical properties. However, there is a need for detailed analysis of filling-tooth assembly durability. Due to relatively long-lasting clinical research and possibility of patients suffering, verification of dental materials should be conducted in laboratory conditions. The authors of this work decided to conduct durability tests of extracted human teeth with treated cavities. For simulation of natural working conditions a specially designed mastication simulator was used. The design of the device was based on assumption that it should simulate mechanical loads taking place during mastication process to the highest degree. The mastication simulator consists of a pneumatic pressing mechanism and biaxial plotter driven by stepper motors. The upper sample is fixed to a slider mechanism which can realize up and down movements while the lower sample is fixed to the biaxial plotter simulating submaxilla motions. In order to provide force field independent on geometry of tested samples, the simulator is equipped with a measurement system which allows for determination of cooperating samples reaction force vector. The curve of shear force occurring between cooperating samples at vertical force 400 N is presented at FIG.2. After realization of programmed mechanical load cycles the specimens are cut in order to measure marginal crevice width.
Źródło:
Engineering of Biomaterials; 2007, 10, no. 65-66; 40-41
1429-7248
Pojawia się w:
Engineering of Biomaterials
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies