Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "dam control network" wg kryterium: Temat


Wyświetlanie 1-2 z 2
Tytuł:
Control network reliability reconstruction for Zatonie dam
Autorzy:
Nowak, E.
Odziemczyk, W.
Powiązania:
https://bibliotekanauki.pl/articles/106901.pdf
Data publikacji:
2018
Wydawca:
Politechnika Warszawska. Wydział Geodezji i Kartografii
Tematy:
network reliability
accuracy harmonisation
dam control network
Zatonie dam
niezawodność sieci
harmonizacja dokładności
tama Zatonie
Opis:
Absolute horizontal displacements are an important element of dam safety level assessment. Appropriate design of measurement network is a prerequisite for the acquisition of displacement values that meet the reliability requirements. A network of this kind, apart from ensuring the required precision of displacement determination, should be characterised by reliability allowing for elimination of gross errors in the results of geodetic surveys. This study aims to propose a method to improve reliability characteristic of surveying network used for horizontal displacement identification in Zatonie dam. The desired effect (increase in the network’s reliability) is obtained by the authors in two stages. The first stage concerns expansion of the existing network by addition of three free stations. As the obtained effect did not prove to be satisfactory, in the second stage so called observation accuracy harmonisation was carried out, which optimally utilises the reliability potential of the measurement construction. In order to successfully carry out the harmonisation, a modification to the procedure’s algorithm had to be introduced. A design of a network ensuring detection of a gross error in any given observation was obtained as the result of the performed actions.
Źródło:
Reports on Geodesy and Geoinformatics; 2018, 105; 1-5
2391-8365
2391-8152
Pojawia się w:
Reports on Geodesy and Geoinformatics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Control network analysis of the dam "Wióry"
Autorzy:
Walo, J.
Szpunar, R.
Woźniak, M.
Powiązania:
https://bibliotekanauki.pl/articles/225005.pdf
Data publikacji:
2007
Wydawca:
Politechnika Warszawska. Wydział Geodezji i Kartografii
Tematy:
zapora ziemna
sieć kontrolna
Wióry
pomiary geodezyjne
earth dam
control network
engineering surveying
Opis:
The obtained results of the test measurements in the control network of the dam Wióry show that combined usage of length measurements and GPS observations enables to obtain high accuracy and reliability in defining point coordinates. The real determination accuracy of checkpoint displacements in this type of networks is at the level of (plus minus) 2-3mm. However, it should be added that in small networks covering an area up to 1 km in radius, classical measurements (most of all, length measurements) enable to obtain higher accuracies in determining point coordinates, obviously on condition that the net structure is well-designed and length measurement is possible. Having analyzed the obtained results, one can also formulate the following conclusions: - the assumed structure of a modified test network shows effective accuracy both for EDM measurements and GPS observations, - satellite measurements enable combined and direct observation of points between which there is no sight line. It is especially important in the case of reference points which are usually located around the monitored object, and it is rarely possible to link them by means of classical measurements; - GPS measurements make it possible to check the monitored network independently, at least limiting the incidence of major and systematic errors in processing the results and defining displacement values; so GPS observations may, in the case of small control networks, be treated as control measurements made periodically (e.g. every year); - accuracy assessment made for TDA5005 tachymeter observations even in the case of considerable target inclinations, made by means of standard reflectors, attested reflexive foil and CCR fulfills monitoring requirements of specific point (targets), enabling to obtain an accuracy of the (plus minus) 0.5 mm range in relation to reference points; - linear measurements in the test network of Wiory, made by means of a TDA5005 tachymeter and high precision reflectors can be accomplished within 2-3 days.
Źródło:
Reports on Geodesy; 2007, z. 1/82; 376-380
0867-3179
Pojawia się w:
Reports on Geodesy
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-2 z 2

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies