Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "current measurements" wg kryterium: Temat


Tytuł:
Possibilities for determining the interference between a power supply network and a converter fed drive
Autorzy:
Beniak, R.
Gardecki, A.
Powiązania:
https://bibliotekanauki.pl/articles/1193393.pdf
Data publikacji:
2017
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
power quality
converter drives
voltage and current measurements
Opis:
Measuring instruments, measurement methods, and an exemplary analysis of the impact of chosen operating stages of the converter drive on the power supply network have been presented. The measurements of electrical and mechanical parameters in drive systems used in industry are complex. The task is difficult due to the necessity of connecting a measuring instrument into electric circuits of an active facility with the use of only short non-operational periods of the device. However, a wellchosen model of a drive system allows the multivariate research of the impact of drive parameters and a control algorithm used on voltage and current harmonic content and performance of the system, and therefore on a simulation analysis of the impact of the drive on the power supply network.
Źródło:
Power Electronics and Drives; 2017, 2, 37/1; 17-26
2451-0262
2543-4292
Pojawia się w:
Power Electronics and Drives
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
System komputerowy do badań wiroprądowych z zastosowaniem cyfrowego przetwornika impedancji
Eddy current test system with digital impedance converter
Autorzy:
Wrzuszczak, M.
Khoma, V.
Powiązania:
https://bibliotekanauki.pl/articles/154270.pdf
Data publikacji:
2011
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
pomiary wiroprądowe
technika DDS
pomiary impedancji
eddy current measurements
DDS
impedance measurements
Opis:
Zwiększenie dokładności i funkcjonalności układów pomiarowych stosowanych w wyspecjalizowanych miernikach wiroprądowych, możliwe jest poprzez wykorzystanie coraz szerszego asortymentu układów scalonych analogowych, analogowo-cyfrowych oraz zastosowanie cyfrowej techniki przetwarzania sygnałów. Poniżej przedstawiony został komputerowy system pomiarowy przystosowany do współpracy z czujnikiem wiroprądowym transformatorowym z wykorzystaniem układu AD5933, mikrokontrolera oraz zastosowaniem techniki DDS.
The paper deals with a problem, how to decrease the measurement uncertainty and shorten the time response of the eddy current test system with a transform transducer. This transducer output signal is complex. Its amplitude and phase or real and imaginary part contain information about the measurand. An IC AD5933 from Analog Devices and two analog to digital converters were used for digital measurements of the eddy current transducer output impedance. The current in the eddy current transducer excitation coil should be sinusoidal. A sinusoidal source is realized through a Direct Digital Synthesis (DDS). AD5933 output registers deliver digital signals to DAC inputs for synthesis of the sin and cos function. The eddy current transducer output signal is processed by Hanning window and Discrete Fourier Transform (DFT). The ATmega micro-controller with the application program controls the mode and operation of the AD 5933 with the eddy current transducer and performs acquisition of the complex measurement signal to its flash memory via I2C interface. Then the RS 232C link to a PC provides transfer of the measurand data for further processing and visual-isation.
Źródło:
Pomiary Automatyka Kontrola; 2011, R. 57, nr 5, 5; 456-459
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Badania symulacyjne wpływu uszkodzeń łożysk silnika indukcyjnego na przebieg chwilowych wartości prądu i napięcia
Simulation researches on influence of bearings damages in induction motor on instantaneous value of current and voltage wave
Autorzy:
Swędrowski, L.
Dzwonkowski, A.
Powiązania:
https://bibliotekanauki.pl/articles/154085.pdf
Data publikacji:
2007
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
diagnostyka silnika
silniki indukcyjne
system diagnostyczny
analiza prądu
prąd
widmo
induction motors
current measurements
diagnostics
spectrum
current supply
Opis:
W referacie przedstawiono wyniki badań symulacyjnych wpływu uszkodzeń łożysk silnika indukcyjnego na przebiegi wartości chwilowych prądu i napięcia. Do analizy przyjęto model zjawisk zachodzących w silniku, polegający na tym, iż odkształcenia prądu i napięcia są skutkiem nieregularności momentu obciążenia silnika, które powodowane są zmiennym momentem oporowym od uszkodzonego łożyska. Odkształcenia mają postać dodatkowych harmonicznych widma, pojawiających się wskutek modulacji przebiegów harmonicznymi o częstotliwościach charakterystycznych dla danego typu uszkodzenia. Przedstawiono wyniki analizy symulacyjnej, wykonanej w programie PSpice. Badania wykonane zostały z wykorzystaniem uproszczonego modelu silnika indukcyjnego, składającego się z rezystancji zmiennej w czasie oraz z indukcyjności. Dla porównania przedstawiono również badania, wykonane przy stałych wartościach parametrów modelu silnika. Następnie omówiono wnioski płynące z wyników przeprowadzonych przez autorów badań.
The paper presents simulation researches of influence of damages in bearings in induction machine on instantaneous current and voltage supply. For analyze was adopted model of phenomena, which rely on the fact, that current and voltage deformation is result of irregularity of load torque in machine. Damages, which appear in the wave, are visible as additional harmonics in the spectrum, owing from modulation of waves by characteristic frequencies for given type of bearings damages. Results of simulations, made in PSpice program, are also shown in this paper. Simulations were made using simple model of induction machine, which consist of oscillating resistance and inductor circuit. Conclusions, which came from those simulations, are also showed.
Źródło:
Pomiary Automatyka Kontrola; 2007, R. 53, nr 4, 4; 41-43
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Design considerations for an 8-decade current-to-digital converter with fA sensitivity
Autorzy:
Voulgari, E.
Noy, M.
Anghinolfi, F.
Perrin, D.
Krummenacher, F.
Kayal, M.
Powiązania:
https://bibliotekanauki.pl/articles/398027.pdf
Data publikacji:
2015
Wydawca:
Politechnika Łódzka. Wydział Mikroelektroniki i Informatyki
Tematy:
radiation monitoring
ultra-low current sensing
leakage currents
sub-picoampere current measurements
pomiar promieniowania
prąd upływu
pomiar pikoamperów
Opis:
Radiation measurements for high energy physics experiments, nuclear facilities, hospitals and hadron therapy institutes require precise low current sensing. This paper provides a methodology for experimental characterisation of the leakage current sources present at the input of a current-to-digital converter. The limitations in sub-picoampere current measurements are presented along with the design of an ASIC that can accurately measure currents in the femto-ampere range after integrating over sufficient time. Proposals to minimise the subthreshold leakage current of the switches connected to the input, the leakage current of the package, the leakage of the PCB and the leakage related to the ESD protection diodes are shown. The remaining leakage current can be measured and subtracted. The front-end can digitise currents over 8 decades produced by a radiation detector. These guidelines were established during the current design and testing and will be used for the second version of the front-end electronics that will be installed at CERN for radiation protection and monitoring.
Źródło:
International Journal of Microelectronics and Computer Science; 2015, 6, 3; 79-85
2080-8755
2353-9607
Pojawia się w:
International Journal of Microelectronics and Computer Science
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Nowe rozwiązanie przetwornika prądu w diagnostyce prądowej silników indukcyjnych
A new solution of current transducer for induction motor current diagnostics
Autorzy:
Swędrowski, L.
Wołoszyk, M.
Ziółko, M.
Powiązania:
https://bibliotekanauki.pl/articles/156002.pdf
Data publikacji:
2011
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
pomiary prądu
diagnostyka
silnik indukcyjny
łożyska toczne
current measurements
diagnostics
asynchronous rotating machines
roll bearings
Opis:
Wadą praktycznie wszystkich opublikowanych systemów do diagnostyki łożysk metodą pomiaru prądu zasilającego w silniku indukcyjnym jest niska jakość układów do pomiaru prądu. W prezentowanej pracy jako przetwornik prądu na napięcie zaproponowano transformator o wysokich parametrach, pracujący z przetwarzaniem prądu na napięcie. W referacie zostaną przedstawione wyniki badań przetwornika, które potwierdziły oczekiwane parametry - niskie szumy własne i liniową charakterystykę w szerokim paśmie.
Vibrations, temperature, acoustic noise, current, instantaneous power [1] and magnetic flux are used for diagnostics of induction motor bearings [2, 3]. The primary source of other signals is shaft vibration. This is the source of disturbance in the machine air gap and, in effect, of the motor current modulation [4]. The main problem in current diagnostics of induction motor bearings [5, 6] is high level of noise in comparison with useful spectra components. Normally used hallotron type of current transducers have high level of noise and non-linear characteristics. In this case the special methods of data processing cannot be helpful in achieving the final result - reliable diagnosis [7, 8, 9]. In the presented paper a high quality current transformer (Fig. 1) was used as a component for current to voltage transformation. The transformer output signal is delivered to a low level noise amplifier and, finally, to a 24 bit DAQ in PXI module. The specially designed software in LabVIEW calculates the signal spectra, especially the amplitudes of spectrum components for certain damages. In the paper there are presented the results of noise investigations (Figs. 5, 6) of the constructed transducer as well as of the accuracy analyses (Figs. 3, 4, 5). All these investigations show that the proposed transducer is better than those used so far. It is expected that results of motor diagnostics obtained with use of the new transducer will have much higher reliability.
Źródło:
Pomiary Automatyka Kontrola; 2011, R. 57, nr 12, 12; 1570-1572
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wykorzystanie metod wibracyjnych do wzorcowania systemu diagnostycznego opartego na analizie prądu zasilającego silnik indukcyjny
Application of vibration methods for calibration of diagnostic system based on motor current analysis
Autorzy:
Swędrowski, L.
Dzwonkowski, A.
Powiązania:
https://bibliotekanauki.pl/articles/320274.pdf
Data publikacji:
2006
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie. Wydawnictwo AGH
Tematy:
diagnostyka wibracyjna
silniki indukcyjne
wzorcowanie
system diagnostyczny
analiza prądu
prąd stojana
widmo
induction motors
current measurements
vibration measurements
diagnostics
spectrum
Opis:
W artykule przedstawiono sposób oceny trafności diagnoz uzyskiwanych z wykorzystaniem nowej metody badawczej, opracowanej do badania uszkodzeń łożysk w silnikach indukcyjnych. Badana metoda diagnostyczna oparta jest na pomiarze i analizie prądu stojana silnika indukcyjnego. W metodzie tej, dla podwyższenia trafności diagnoz, obliczanie zarówno prędkości kątowej silnika, jak i częstotliwości sieci zasilającej jest wykonywane na podstawie tego samego widma, które dalej jest wykorzystywane do pomiaru składowych harmonicznych charakterystycznych dla uszkodzeń łożysk. Sztucznie uszkodzone łożyska poddawano kwalifikacji pod względem głębokości i rodzaju uszkodzenia, wykorzystując urządzenie pomiarowe zbudowane na podstawie opracowanej metody, również wykonując badania sprawdzonym systemem diagnostyki wibracyjnej. Niektóre wyniki badań łożysk o różnych typach i głębokości uszkodzenia oraz wnioski płynące z tych pomiarów zostały podane w niniejszym artykule.
Damage of the bearings is the most frequent cause of squirrel cage induction machines failure. In some applications the current signal is the only potential source of information about the state of the machine, including the state of its bearings. Damage of the raceway or of the rolling element is followed by additional vibrations of the rotor. These vibrations are reflected in spectral composition of the stator currents. The new measuring method and the supply current analysis were elaborated for diagnostic of the motor bearings. In this method it is possible to recognize type of bearing fault, checking the control sum for each type of possible fault. The investigation referring to real objects were performed. The investigations were carried out using motors with bearings having defects caused on purpose. Examples of diagnostic results in case of: a) faultless bearings, b) bearing with damaged outer ring are presented in Figures 2 and 3. Marks from L1 to L20 in the Figures 2 and 4 define loads from idle running (L1) to 75% of rated power (L20). The correctness of distinguishing the type of damage was investigated. The diagnosis was assumed to be correct if it conforms to the defects indicated by the standard system of the vibration diagnostics, of course, when other damages were not detected. Figures 1 and 3 show the vibration testing results. The probability of correct distinguishing the type of damage defined this way is shown in the Figure 4. The average probability of diagnostic correctness determined this way reaches 70%. The probability that the system will identify correctly at least one existing defect is more than 90%. The investigations shows, that for testing new diagnostic method it is not enough to make damage to bearing but also have other reliable diagnostic method. This method defines real state of investigated bearing.
Źródło:
Elektrotechnika i Elektronika; 2006, 25, 2; 202-206
1640-7202
Pojawia się w:
Elektrotechnika i Elektronika
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Pomiary w diagnostyce łożysk silników indukcyjnych
Measurements for diagnostics of induction motor bearings
Autorzy:
Swędrowski, L.
Powiązania:
https://bibliotekanauki.pl/articles/157816.pdf
Data publikacji:
2010
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
pomiary wibracji
pomiary prądu
diagnostyka
silnik indukcyjny
łożyska toczne
asynchronous rotating machines
current measurements
fault diagnosis
vibration measurements
roll bearings
Opis:
Jak wynika z szeregu badań, w silniku indukcyjnym najczęściej uszkodzeniom ulegają łożyska. W referacie omówione są badania, dotyczące diagnostyki łożysk silników z wykorzystaniem pomiarów wibracji (akcelerometrem piezoelektrycznym i laserowym) oraz prądu silnika. Są również wymienione inne sygnały, stosowane do diagnostyki łożysk. Przedstawione są wyniki dotychczasowych badań autora, świadczące o przydatności pomiarów wielkości elektrycznych w silniku do diagnostyki łożysk.
There can appear some damages of induction motor mechanical parts (such as bearings, rotor, shaft), or of induction motor electromagnetic system elements, for example the stator, rotor winding or the magnetic circuit. Extensive research shows that the bearings are the element most susceptible to damage. Therefore bearing diagnostics is so important in supervision of motor condition. The paper presents investigations which the author finds interesting, i.e. those concerning the diagnostics of motor bearings which utilises measurements of vibrations (by piezoelectric and laser vibrometer), motor current (MCSA) and instantaneous power consumed by the motor. The metod of motor current analysis, elaborated by the author, is shown in Fig.5. Other signals used for bearing diagnostics are also mentioned in the paper. The results obtained from the objects in which bearing damage was on purpose introduced are given in this paper. Verification of the obtained results was performed through assessment of bearing condition with use of a vibration diagnostics system. There are presented the conclusions drawn from the investigations at the present stage (Figs.6 and 7), regarding usability of electric signal measurements for diagnostics of bearings. In the future the author plans reduction of the measurement system noise as well as widening the range of faults recognised by the diagnostic system. Also the reliability of diagnosis from the motor current system will be improved.
Źródło:
Pomiary Automatyka Kontrola; 2010, R. 56, nr 9, 9; 1024-1027
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Pomiary mocy chwilowej w diagnostyce łożysk silników indukcyjnych
Instantaneous power measurements in induction motor bearing diagnostics
Autorzy:
Dzwonkowski, A.
Powiązania:
https://bibliotekanauki.pl/articles/156016.pdf
Data publikacji:
2011
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
diagnostyka łożysk
pomiary napięcia
pomiary prądu
moc chwilowa
widmo mocy chwilowej
wibracje
silnik indukcyjny
bearing diagnostics
voltage measurement
current measurements
instantaneous power spectrum
vibration
induction motor
Opis:
W artykule przedstawiono zagadnienia dotyczące diagnostyki łożysk z wykorzystaniem metody badawczej, opartej na pomiarze i analizie mocy chwilowej pobieranej przez silnik indukcyjny. Przedstawiono przykładowe wyniki wykonanych pomiarów w oparciu o proponowaną metodę oraz przeprowadzono ich analizę. Na podstawie przeprowadzonej analizy sformułowano wnioski dotyczące możliwości wykorzystania proponowanej metody do diagnostyki łożysk.
The paper deals with the issue of bearing diagnostics using the method based on measurements and analysis of a product of instantaneous values of the stator current and supply voltage of induction machines. The introduction of the paper contains general assumptions of the used method and description of the research methodology. The second and third sections present the laboratory stand used for investigations as well as the methodology of the research. The fourth section contains some examples of the measurement results obtained with use of the proposed method and the analysis of these results. The measurements were taken on induction motors. The investigation results for an undamaged machine are shown in Fig. 1, while those for motors with a damaged bearing outer and inner ring are presented in Figs. 2 and 4. The investigation results for a machine with damage of a bearing outer ring for different load torque values are shown in Fig. 6, whereas Figs. 3 and 5 present the vibration measurements of damaged machines. The summary contains the main conclusions concerning the possibility of using the proposed method for bearing diagnostics of induction motors.
Źródło:
Pomiary Automatyka Kontrola; 2011, R. 57, nr 12, 12; 1589-1591
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Design and test of a new high-current electronic current transformer with a Rogowski coil
Autorzy:
Zhang, M.
Li, K.
He, S.
Wang, J.
Powiązania:
https://bibliotekanauki.pl/articles/221051.pdf
Data publikacji:
2014
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
Rogowski coil
high-current
electronic current transformers
electrical measurements
Opis:
This paper describes the design and test of a new high-current electronic current transformer based on a Rogowski coil. For better performances, electronic current transformers are used to replace conventional electro-magnetic inductive current transformers based on ferromagnetic cores and windings to measure high-current on the high voltage distribution grids. The design of a new high-current electronic current transformer is described in this paper. The principal schemes of the prototype and partial evaluation results are presented. Through relative tests it is known that the prototype has a wide dynamic range and frequency band, and it can allow high accuracy measurements.
Źródło:
Metrology and Measurement Systems; 2014, 21, 1; 121-132
0860-8229
Pojawia się w:
Metrology and Measurement Systems
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Measurement Results Based Approximation of the Nonlinear Flux-Current Characteristic of an Electromechanical Actuator
Autorzy:
Kowalik, Z.
Powiązania:
https://bibliotekanauki.pl/articles/114487.pdf
Data publikacji:
2016
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
simplicial approximation
mathematical modelling
electrical measurements
flux-current characteristic
Opis:
A Hamiltonian model of an electromechanical actuator requires approximation of its flux-current characteristic. It can be made using a simplicial approximation, which requires the sets of corresponding points in the spaces of currents and fluxes. These points can be chosen from the trajectories that describe the behaviour of the electromechanical system in these spaces. In the paper, a method of obtaining these trajectories by measurements is shown and four original methods of choosing points lying on them to construct the required points sets are presented. The sets are constructed so that they contain a possibly small number of points, but the approximation which is based on them is precise. The presented methods are used to approximate a flux-current characteristic of the prototype synchronous reluctance machine. The simulation results, computed using the models based on these approximations, are also presented and discussed. The best results are obtained by methods using the computed value of the magnetic field coenergy in the modelled machine.
Źródło:
Measurement Automation Monitoring; 2016, 62, 2; 49-54
2450-2855
Pojawia się w:
Measurement Automation Monitoring
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Parametry częstotliwościowe przetworników prądowych wykonanych w technologii PCB1 i HDI2
Frequency parameters of current-mode converters made in PCB1 i HDI2 technologies
Autorzy:
Lisowiec, A.
Nowakowski, A.
Powiązania:
https://bibliotekanauki.pl/articles/186475.pdf
Data publikacji:
2014
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Technik Innowacyjnych EMAG
Tematy:
przetworniki prądowe
parametry częstotliwościowe
pomiary
current-mode converters
frequency parameter
measurements
Opis:
W artykule przedstawiono wyniki pomiarów oraz analizę charakterystyk częstotliwościowych przetworników prądowych wykonanych w technologii PCB HDI. Najpierw omówiono konstrukcję bez-rdzeniowych przetworników wykonanych w technologii PCB HDI. Następnie określono wartości elementów układu zastępczego przetwornika bezrdzeniowego. Na koniec przytoczono charakterystyki częstotliwościowe przetworników bezrdzeniowych wykonanych w tradycyjnej technologii PCB oraz w technologii HDI.
The article presents the measurement results and analysis of frequency characteristics of current-mode converters made with the use of the PCB HDI technology. First the structure of rodless PCB HDI converters was discussed. Then the values of the elements of an equivalent circuit in a rodless converter were determined. Finally, the authors discussed the frequency characteristics of rodless converters made with the use of either the traditional PCB technology or the HDI technology.
Źródło:
Mechanizacja i Automatyzacja Górnictwa; 2014, R. 52, nr 5, 5; 12-17
0208-7448
Pojawia się w:
Mechanizacja i Automatyzacja Górnictwa
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Evaluation of Applicability of Classic Methods of a Fault Loop Impedance Measurement to Circuits with Residual Current Devices
Ocena przydatności klasycznych metod pomiaru impedancji pętli zwarciowej do obwodów z wyłącznikami różnicowoprądowymi
Autorzy:
Czapp, S.
Borowski, K.
Powiązania:
https://bibliotekanauki.pl/articles/397224.pdf
Data publikacji:
2016
Wydawca:
ENERGA
Tematy:
wyłącznik różnicowoprądowy
impedancja pętli zwarciowej
pomiary
residual current device
fault loop impedance
measurements
Opis:
Measurement of fault loop impedance in low voltage grids and systems is in most cases performed to verify the effectiveness of protection against electric shock by automatic disconnection of supply. For the sake of measurement accuracy, it is advisable to perform it using large current. Unfortunately, in circuits with residual current devices which are very widely used nowadays, a large measurement current may trigger those devices unnecessarily. The study presents results of an investigation of residual current devices behaviour during measurements of fault loop impedance performed with selected measuring devices. The tests have been performed on circuits with residual current devices with a rated residual operating current IΔn = 30 mA, of AC and A type. Based on the performed tests and analyses, a method for measurement of fault loop impedance which does not unnecessarily trigger residual current devices has been proposed.
Pomiar impedancji pętli zwarciowej w sieciach i instalacjach niskiego napięcia wykonuje się najczęściej w celu oceny skuteczności ochrony przeciwporażeniowej przez samoczynne wyłączanie zasilania. Z punktu widzenia dokładności pomiaru korzystne jest, aby wykonać go dużym prądem. Niestety, w obwodach z wyłącznikami różnicowoprądowymi, które obecnie są stosowane na bardzo szeroką skalę, duży prąd pomiarowy może powodować ich zbędne wyzwalanie. W pracy przedstawiono wyniki badań zachowania się wyłączników różnicowoprądowych przy pomiarze impedancji pętli zwarciowej, wykonanym wybranymi miernikami. Badania przeprowadzono w obwodach z wyłącznikami różnicowoprądowymi o prądzie znamionowym różnicowym IΔn = 30 mA, typu AC oraz typu A. Na podstawie przeprowadzonych badań i analiz zaproponowano sposób pomiaru impedancji pętli zwarciowej, który nie powoduje zbędnego zadziałania wyłączników różnicowoprądowych.
Źródło:
Acta Energetica; 2016, 3; 45-52
2300-3022
Pojawia się w:
Acta Energetica
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Prototype of an Integrating Current Transformer for Beam Intensity Measurements in the Large Hadron Collider
Autorzy:
Krupa, M
Napieralski, A
Powiązania:
https://bibliotekanauki.pl/articles/398102.pdf
Data publikacji:
2013
Wydawca:
Politechnika Łódzka. Wydział Mikroelektroniki i Informatyki
Tematy:
diagnostyka wiązki
pomiar natężenia wiązki
transformator
ICT
FBCT
beam diagnostics
beam intensity measurements
Integrating Current Transformer
Fast Beam Current Transformer
Opis:
The beam intensity (number of particles forming the beam) in the Large Hadron Collider (LHC) is measured by eight current transformers. The average beam current is monitored by the four DC Current Transformers (DCCTs) and the range from a few hundred hertz to over a gigahertz is covered by the four Fast Beam Current Transformers (FBCTs). During the early run of the LHC the beam intensity measured by the FBCTs was observed to be correlated to the beam position and charge distribution. To address the consequential limitations a prototype of an Integrating Current Transformer (ICT) has been developed at CERN as a possible future replacement of the FBCTs. In this article, its design, principle of operation along with results of first beam tests are presented. The measured beam-position-dependency of the ICT has been improved, compared to the FBCT, by a factor of 35 and 50 in the vertical and horizontal planes, respectively.
Źródło:
International Journal of Microelectronics and Computer Science; 2013, 4, 1; 32-36
2080-8755
2353-9607
Pojawia się w:
International Journal of Microelectronics and Computer Science
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Electromagnetic Action of Heavy-Current Equipment Operating With Power Frequency
Autorzy:
Bednarek, K.
Powiązania:
https://bibliotekanauki.pl/articles/91077.pdf
Data publikacji:
2010
Wydawca:
Centralny Instytut Ochrony Pracy
Tematy:
electromagnetic action
heavy-current equipment
power frequency
calculation and measurements of EMF
ergonomic aspect
Opis:
The paper presents an analysis of the effect of magnetic fields of power frequency generated by heavy-current electric equipment on the environment. The results of computation and measurements of the magnetic field in the vicinity of power busducts are included. Possible hazards are considered that result from the effects of the magnetic field on workers present in the vicinity of busducts as well as secondary hazards caused by the degrading effect of the magnetic field on ferromagnetic structural materials (in reinforced concrete structures). Attention is given to an ergonomic aspect of interaction of the magnetic field with cathode ray tube computer monitors (annoying oscillation of the image).
Źródło:
International Journal of Occupational Safety and Ergonomics; 2010, 16, 3; 357-368
1080-3548
Pojawia się w:
International Journal of Occupational Safety and Ergonomics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Uncertainty of the magnetic flux linkage measurements performed by modified current decay test
Autorzy:
Kowalik, Z.
Powiązania:
https://bibliotekanauki.pl/articles/141517.pdf
Data publikacji:
2017
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
flux linkage measurements
modified current decay test
uncertainty of integral calculations
uncertainty of simplicial approximation
Opis:
The paper presents the estimation methodology for uncertainties of magnetic flux linkage measurements, when the flux linkage and current functions with respect to time are obtained instead of single values of these quantities. The computed uncertainties are then used to estimate the quality of an approximation of a current-flux characteristic in the mathematical model of an electrical machine when the approximation is based on the results of measurements.
Źródło:
Archives of Electrical Engineering; 2017, 66, 3; 643-653
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies