Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "current generator" wg kryterium: Temat


Tytuł:
The power electronics controlled current source utilized in the reference current generator
Autorzy:
Gwóźdź, M.
Powiązania:
https://bibliotekanauki.pl/articles/377579.pdf
Data publikacji:
2013
Wydawca:
Politechnika Poznańska. Wydawnictwo Politechniki Poznańskiej
Tematy:
power electronics
current controlled voltage source
current generator
Opis:
The paper considers wide-band voltage controlled power electronics current source. The current source has been designed as a part of 1-channel reference current generator designed for current meters testing. The control module of the generator utilizes specialized Analog Devices Inc. DSPs based microcomputer module for power electronics applications. Used solutions have allowed obtain high quality referencing of the output current within reference signal. The paper presents the structure and selected aspects of the control algorithm of the current source. Also selected investigations results of laboratory prototype of generator with utilization of controlled current source are presented.
Źródło:
Poznan University of Technology Academic Journals. Electrical Engineering; 2013, 76; 9-14
1897-0737
Pojawia się w:
Poznan University of Technology Academic Journals. Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Alternator diagnostics by means of an oscilloscope and infrared radiation – comparison of methods
Diagnostyka alternatora z wykorzystaniem oscyloskopu i promieniowania podczerwonego - porównanie metod
Autorzy:
Styla, S.
Wrobel, K.
Boguta, A.
Powiązania:
https://bibliotekanauki.pl/articles/793028.pdf
Data publikacji:
2013
Wydawca:
Komisja Motoryzacji i Energetyki Rolnictwa
Tematy:
alternative current generator
alternator
diagnostics
thermovision camera
electrical power supply
oscilloscope
infrared radiation
Źródło:
Teka Komisji Motoryzacji i Energetyki Rolnictwa; 2013, 13, 1
1641-7739
Pojawia się w:
Teka Komisji Motoryzacji i Energetyki Rolnictwa
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Power injection control system and experimental model based on manufacturer characteristic curves for a photovoltaic generation system
Autorzy:
Rico, A.
Cadaval, E. R.
Montero, M. I. M.
Powiązania:
https://bibliotekanauki.pl/articles/262582.pdf
Data publikacji:
2007
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie
Tematy:
Inverter Current Controller (ICC)
Inverter Reference Current Generator (ICRG)
maximum power point tracking (MPPT)
Photovoltaic Cell (PV Cell)
PV Voltage and PV Current
VI characteristic equations
Opis:
This paper attempts to validate the performance of a power injection control block for Photovoltaic Generation Systems (PVGS). This device uses a control module based on detecting the power injected into the supply by the inverter, instead of measuring the power generated by the PVGS. The performance is evaluated using the concept of Maximum Energy Curve that takes into account both transient and permanent control performance. The paper presents a basic and simple procedure to obtain a model from the manufacturer characteristic curves of the photovoltaic cells. MATLAB Simulink is used as simulation tool to obtain the response of the proposed system to changes in temperature and irradiance.
Źródło:
Electrical Power Quality and Utilisation. Journal; 2007, 13, 2; 69-75
1896-4672
Pojawia się w:
Electrical Power Quality and Utilisation. Journal
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Operation of electric hybrid drive systems in varied driving conditions
Eksploatacja elektrycznych układów napędowych pojazdów hybrydowych w zróżnicowanych warunkach ruchu
Autorzy:
Pielecha, I.
Cieślik, W.
Szałek, A.
Powiązania:
https://bibliotekanauki.pl/articles/1365373.pdf
Data publikacji:
2018
Wydawca:
Polska Akademia Nauk. Polskie Naukowo-Techniczne Towarzystwo Eksploatacyjne PAN
Tematy:
electric motor
current generator
hybrid drive
voltage boost
energy flow
high voltage battery
silnik elektryczny
generator prądu
napęd hybrydowy
wzmocnienie napięcia
przepływ energii
akumulator wysokonapięciowy
Opis:
Hybrid vehicles allow an increase in the powertrain efficiency thanks to their design. One such factor is the use of increased voltage supplying electric motors to the voltage supplying the high voltage battery. The battery voltage is increased several times in the inverter (boost) system to increase the final electric power supplied to the electric motor. The article presents the possibilities of using such a voltage boost in urban and non-urban driving conditions. The tests were performed on the latest generations of parallel hybrid drive systems in Lexus NX 300h and Toyota RAV4 hybrid vehicles. It has been shown that the boost system is used in about 30–40% of the urban drive distance (up to 20% of the driving time). The power supply voltage boost of the electric motors of both vehicles is used throughout the entire engine speed range of these machines at high torque values. Research has shown that the maximum voltage gain – approximately three times (up to 650 V) – is within the maximum torque range of the electric motors and allows for doubling the torque generated by the drive.
Pojazdy z napędem hybrydowym dzięki swojej konstrukcji, pozwalają na zwiększenie sprawności układu napędowego. Jednym z takich czynników jest stosowanie zwiększonego napięcia zasilającego silniki elektryczne w stosunku do napięcia zasilającego akumulator wysokonapięciowy. Napięcie akumulatora zostaje zwiększone kilkukrotnie w układzie inwertera (boost) w celu zwiększenia końcowej mocy elektrycznej doprowadzonej do silnika elektrycznego. W artykule przedstawiono możliwości wykorzystania takiego wzmocnienia napięcia w warunkach jazdy miejskiej i pozamiejskiej. W badaniach wykorzystano najnowsze generacje układów napędu hybrydowego równoległego w pojazdach Lexus NX 300h oraz Toyota RAV4 hybrid. Wykazano, że układ wzmocnienia napięcia w warunkach miejskich wykorzystany jest w około 30–40% dystansu (do 20% czasu jazdy). Wzmocnienie napięcia zasilającego maszyny elektryczne obu pojazdów wykorzystane jest w całym zakresie prędkości obrotowej tych maszyn przy dużych wartościach momentu obrotowego. Badania wykazały, że maksymalne wzmocnienie napięcia – około trzykrotne (do wartości 650 V) – występuje w zakresie maksymalnego momentu obrotowego silników elektrycznych i pozwala na ponad 2-krotne zwiększenie generowanego momentu obrotowego układu napędowego.
Źródło:
Eksploatacja i Niezawodność; 2018, 20, 1; 16-23
1507-2711
Pojawia się w:
Eksploatacja i Niezawodność
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Eddy current density asymmetric distribution of damper bars in bulb tubular turbine generator
Autorzy:
Qiu, H.
Fan, X.
Yi, R.
Feng, J.
Wu, J.
YANG, C.
ZHAO, H.
Powiązania:
https://bibliotekanauki.pl/articles/140467.pdf
Data publikacji:
2017
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
damper bars
bulb tubular turbine generator
electromagnetic field
eddy current
Opis:
The major reasons that cause the damage of damper bars in the leeward side are found in this paper. It provides a route for the structure optimization design of a hydro generator. Firstly, capacity of a 24 MW bulb tubular turbine generator is taken as an example in this paper. The transient electromagnetic field model is established, and the correctness of the model is verified by the comparison of experimental results and simulation data. Secondly, when the generator is operated at rated condition, the eddy current density distributions of damper bars are studied. And the asymmetric phenomenon of the eddy current density on damper bars is discovered. The change laws of the eddy currents in damper bars are determined through further analysis. Thirdly, through the study of eddy current distributions under different conditions, it is confirmed that the stator slots and armature reaction are the main factors to affect the asymmetric distribution of the eddy current in damper bars. Finally, the studies of the magnetic density distribution and theoretical analysis revealed the asymmetric distribution mechanism of eddy current density.
Źródło:
Archives of Electrical Engineering; 2017, 66, 3; 571-581
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Synchrogenverter - parallel connection of synchronous generator and power converter with energy storage
Autorzy:
Szulawski, P.
Koczara, W.
Powiązania:
https://bibliotekanauki.pl/articles/1193215.pdf
Data publikacji:
2016
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
synchronous generator
power electronic converter
synchrogenverter
energy storage current control
Opis:
The paper describes novel power generation topology wherein synchronous generator have a parallel connected power electronic converter. In this arrangement synchronous generator is only source of active power and power electronic converter is source of reactive power. Such power distribution allows to increase the synchronous generator generated active power by 25%, and operate with unity power factor. The power converter with energy storage system embedded can deliver additional active power in transient state to improve generator stability.
Źródło:
Power Electronics and Drives; 2016, 1, 36/1; 69-78
2451-0262
2543-4292
Pojawia się w:
Power Electronics and Drives
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Recognition of armature current of DC generator depending on rotor speed using FFT, MSAF-1 and LDA
Rozpoznawanie sygnałów prądu twornika generatora prądu stałego w zależności od prędkości obrotowej wirnika z zastosowaniem FFT, MSAF-1 i LDA
Autorzy:
Głowacz, A.
Głowacz, W.
Głowacz, Z.
Powiązania:
https://bibliotekanauki.pl/articles/1365895.pdf
Data publikacji:
2015
Wydawca:
Polska Akademia Nauk. Polskie Naukowo-Techniczne Towarzystwo Eksploatacyjne PAN
Tematy:
fault detection
pattern recognition
armature current
DC generator
detekcja uszkodzenia
rozpoznawanie wzorców
prąd twornika
generator prądu stałego
Opis:
Recognition of states of electrical systems is very important in industrial plants. Article describes a recognition method of early fault detection of DC generator. The proposed approach is based on an analysis of the patterns. These patterns are the armature currents of selected electrical machine. Information contained in signals of armature current is depending on generator state. Researches were carried out for four states of generator with the use of Fast Fourier Transform (FFT), method of selection of amplitudes of frequencies (MSAF-1) and Linear Discriminant Analysis (LDA). The results of analysis show that the method is efficient and can be used to protect DC generators. This method was verified with the aid of acoustic signals recognition method.
Rozpoznawanie stanów układów elektrycznych jest bardzo ważne w zakładach przemysłowych. W artykule opisano metodę rozpoznawania stanów przedawaryjnych generatora prądu stałego. Proponowane podejście jest oparte na badaniu wzorców. Wzorce te są prądami twornika wybranej maszyny elektrycznej. Informacja zawarta w sygnałach prądu twornika jest zależna od stanu generatora. Przeprowadzono badania dla czterech stanów generatora z zastosowaniem FFT, metody wyboru amplitud częstotliwości (MSAF-1) i liniowej analizy dyskryminacyjnej (LDA). Wyniki analizy pokazują, że metoda jest skuteczna i metoda może być stosowana do ochrony generatorów prądu stałego. Metoda została zweryfikowana za pomocą metody rozpoznawania sygnałów akustycznych.
Źródło:
Eksploatacja i Niezawodność; 2015, 17, 1; 64-69
1507-2711
Pojawia się w:
Eksploatacja i Niezawodność
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wpływ kompensacji prądowej na pracę generatora przy zmianach napięcia w KSE
Autorzy:
Zajczyk, R.
Szczeciński, P.
Powiązania:
https://bibliotekanauki.pl/articles/396885.pdf
Data publikacji:
2010
Wydawca:
ENERGA
Tematy:
Krajowy System Elektroenergetyczny
generator
kompensacja prądu
National Power System
current compensation
Opis:
Artykuł prezentuje wpływ kompensacji prądowej na wrażliwość zmian mocy biernej generatora przy zmianach napięcia w sieci. Wyniki badań przedstawiono dla dwóch różnych sposobów estymacji sygnału od kompensacji prądowej, które pozwalają regulatorowi generatora utrzymywać zadaną wartość napięcia w innym miejscu niż zaciski generatora. W artykule omówiono niezbędne zmiany, które należy wprowadzić w regulacji grupowej ARNE, przy wprowadzeniu kompensacji prądowej w układach regulacji generatorów.
Źródło:
Acta Energetica; 2010, 2; 77-82
2300-3022
Pojawia się w:
Acta Energetica
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The novel control method of switched reluctance generator
Autorzy:
Bogusz, P.
Powiązania:
https://bibliotekanauki.pl/articles/140482.pdf
Data publikacji:
2017
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
switched reluctance generator
electric vehicle
current control
low speed
high speed
Opis:
In the paper, a novel control method of a switched reluctance generator was discussed. The presented control method allows a rotor rotating at high speed to enter the continuous-conduction mode which causes an increase of generated output power. A control function of the presented method was given as well as simulation and laboratory tests.
Źródło:
Archives of Electrical Engineering; 2017, 66, 2; 409-422
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Fast control of the six phase asymmetric generator with the 3rd harmonic current injection
Autorzy:
Gołębiowski, M.
Powiązania:
https://bibliotekanauki.pl/articles/141252.pdf
Data publikacji:
2016
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
6-phase asymmetric generator
third harmonic current injection
control trajectories
MTPA
MTPF
Opis:
In this paper the MTPA, MTPF, constant torque and constant flux control trajectories are presented. These trajectories are calculated for a 6-phase asymmetric insettype SMPMSM generator with the assumption of a certain level of 3rd harmonic current injection. This injection technique increases the generator performance due to the cooperation of the fundamental and 3rd harmonic. The presented trajectories are used for fast control of the generator working in the gearless wind turbine system.
Źródło:
Archives of Electrical Engineering; 2016, 65, 1; 59-71
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies