Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "current compensation" wg kryterium: Temat


Wyświetlanie 1-14 z 14
Tytuł:
Parametric-active compensation of earth fault current in an IT-type network
Autorzy:
German-Galkin, S.
Hrynkiewicz, J.
Powiązania:
https://bibliotekanauki.pl/articles/1193299.pdf
Data publikacji:
2017
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
IT-type networks
earth current
fault current compensation
Opis:
The parametric-active compensation of earth leakage currents which minimalized virtual capacitance current in ships of IT-type network has been discussed. The protection is based on automatic compensation of leakage earth currents. The protection system is governed by a controller. The results of simulation tests have been presented. The parametric-active compensation of earth leakage currents which minimalized virtual capacitance current in ships with IT-type network has been discussed.
Źródło:
Power Electronics and Drives; 2017, 2, 37/1; 81-87
2451-0262
2543-4292
Pojawia się w:
Power Electronics and Drives
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Maximizing power output of a partially shaded total-cross-tied photovoltaic array
Autorzy:
Shah, N. S.
Patel, H. H.
Powiązania:
https://bibliotekanauki.pl/articles/136262.pdf
Data publikacji:
2017
Wydawca:
EEEIC International Barbara Leonowicz Szabłowska
Tematy:
current compensation
voltage equalization
MPPT
partial shading
TCT configuration
Opis:
Non-uniform conditions on the modules of the PV array, especially, partial shading reduces the output of the PV array to a large extent. The shaded module in a string limits the current of the entire string and hence, the output power of the string. The output power under such conditions is reported to be higher for total-cross-tied (TCT) configuration. This paper describes two different approaches, one based on current compensation (current equalization) and another based on voltage equalization, to extract higher power from the partially shaded total-cross-tied photovoltaic array. The TCT configuration is considered to minimize the number of converters, sensors, cost and complexity involved. The additional converters in the two distinct approaches evaluated here operate only when the partial shading occurs and are controlled to minimize the current and voltage miss-matches. The analysis and the control algorithm are presented. Simulation results obtained in MATLAB/Simulink are included to demonstrate the effectiveness of both methods and the relative merits and demerits of these approaches are highlighted.
Źródło:
Transactions on Environment and Electrical Engineering; 2017, 2, 1; 10-18
2450-5730
Pojawia się w:
Transactions on Environment and Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wpływ kompensacji prądowej na pracę generatora przy zmianach napięcia w KSE
Autorzy:
Zajczyk, R.
Szczeciński, P.
Powiązania:
https://bibliotekanauki.pl/articles/396885.pdf
Data publikacji:
2010
Wydawca:
ENERGA
Tematy:
Krajowy System Elektroenergetyczny
generator
kompensacja prądu
National Power System
current compensation
Opis:
Artykuł prezentuje wpływ kompensacji prądowej na wrażliwość zmian mocy biernej generatora przy zmianach napięcia w sieci. Wyniki badań przedstawiono dla dwóch różnych sposobów estymacji sygnału od kompensacji prądowej, które pozwalają regulatorowi generatora utrzymywać zadaną wartość napięcia w innym miejscu niż zaciski generatora. W artykule omówiono niezbędne zmiany, które należy wprowadzić w regulacji grupowej ARNE, przy wprowadzeniu kompensacji prądowej w układach regulacji generatorów.
Źródło:
Acta Energetica; 2010, 2; 77-82
2300-3022
Pojawia się w:
Acta Energetica
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
A concept of new current compensation in a hv/mv transformer’s semiconductor tap-changer controller
Koncepcja nowej kompensacji prądowej w regulatorze półprzewodnikowych przełączników zaczepów transformatora WN/SN
Autorzy:
Korpikiewicz, Jarosław Grzegorz
Powiązania:
https://bibliotekanauki.pl/articles/952888.pdf
Data publikacji:
2019
Wydawca:
ENERGA
Tematy:
regulacja napięcia
kompensacja prądowa
półprzewodnikowe przełączniki zaczepów
voltage regulation
current compensation
semiconductor tap-changers
Opis:
The purpose of the paper is to develop a new current compensation in the tap-changer controllers of HV/MV transformer. Problems in applying classical current compensation are presented. A mathematical model of current compensation has been created, taking into account the phase measurements offered by grid parameter meters. A new method of current compensation has been proposed for the controller of semiconductor tap-changers of HV/MV transformers.
Celem artykułu jest opracowanie nowej kompensacji prądowej w regulatorach przełączników zaczepów transformatora WN/SN. Zaprezentowano problemy w stosowaniu klasycznej kompensacji prądowej. Utworzono model matematyczny kompensacji prądowej z uwzględnieniem pomiarów fazowych oferowanych przez mierniki parametrów sieci. Zaproponowano nową metodę kompensacji prądowej dla regulatora półprzewodnikowych przełączników zaczepów transformatora WN/SN.
Źródło:
Acta Energetica; 2019, 1; 37-44
2300-3022
Pojawia się w:
Acta Energetica
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Current ripple reduction for finite control set model predictive control strategy of grid-tied inverter with reference current compensation
Autorzy:
Jin, Nan
Fan, Wuchuang
Fang, Jie
Wu, Jie
Shen, Yongpeng
Powiązania:
https://bibliotekanauki.pl/articles/2202542.pdf
Data publikacji:
2023
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
cost function
current ripple reduction
finite control set model predictive control
FCS-MPC
grid-tied inverter
reference current compensation
RCC
Opis:
In the finite control set model predictive control (FCS-MPC) strategy of the grid-tied inverter, the current ripple (CR) affects the selection of optimal voltage vectors, which leads to the increase of output current ripples. In order to solve this problem, this paper proposes a CR reduction method based on reference current compensation (RCC) for the FCS-MPC strategy of grid-tied inverters. Firstly, the influence of the CR on optimal voltage vector selection is analyzed. The conventional CR prediction method is improved, which uses inverter output voltage and grid voltage to calculate current ripples based on the space state equation. It makes up for the shortcomings that the conventional CR prediction method cannot predict in some switching states. The improved CR method is more suitable for the FCS-MPC strategy. In addition, the differences between the two cost functions are compared through visual analysis. It is found that the sensitivity of the square cost function to small errors is better than that of the absolute value function. Finally, the predicted CR is used to compensate the reference current. The compensated reference current is substituted into the square cost function to reduce the CR. The experimental results show that the proposed method reduces the CR by 47.3%. The total harmonic distortion (THD) of output current is reduced from 3.86% to 2.96%.
Źródło:
Archives of Electrical Engineering; 2023, 72, 1; 5--22
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Zastosowanie nowego algorytmu kompensacji prądowej w regulatorze przełącznika zaczepów transformatora WN/SN
Application of a new algorithm for current compensation at the regulator of the tap-changer for HV/MV transformers
Autorzy:
Korpikiewicz, Jarosław
Powiązania:
https://bibliotekanauki.pl/articles/268260.pdf
Data publikacji:
2019
Wydawca:
Politechnika Gdańska. Wydział Elektrotechniki i Automatyki
Tematy:
kompensacja prądowa
asymetria napięć
asymetria obciążenia
STM32
elektroniczne przełączniki zaczepów transformatora
current compensation
voltage asymmetry
load asymmetry
solid-state tap-changers for transformer
Opis:
Artykuł dotyczy regulacji napięcia w sieci SN za pomocą statycznych przełączników zaczepów. W artykule rozważano problematykę kompensacji prądowej w regulatorze przełączników zaczepów transformatora WN/SN. Kompensacja prądowa obecnie jest często wyłączana. Jest to spowodowane tym, że kompensacja dotyczy wirtualnej pojedynczej linii SN. W artykule przedstawiono wyniki symulacji na modelu fizycznym dla prostej sieci SN zasilanej ze stacji WN/SN przy występowaniu asymetrii napięć i obciążeń dla trzech przypadków: wyłączona kompensacja prądowa, klasyczna kompensacja oraz proponowana jej nowa formuła. Proponowany algorytm zaimplementowano na mikrokontrolerze STM32. W celu uwzględnienia asymetrii wykorzystano pomiary w trzech fazach, co wymaga modyfikację układu pomiarowego.
The article concerns voltage regulation in MV network by means of static tap changers. The article considers the problem of current compensation in the HV / MV transformer tap changer controller. Current compensation is often turned off. This is due to the fact that the compensation applies to a virtual single SN line. The article presents simulation results on a physical model for a simple MV network fed from a WN / SN station with the occurrence of voltage and load asymmetry for three cases: switched off current compensation, classical compensation and the proposed new formula. The proposed algorithm has been implemented on the STM32 microcontroller. In order to take into account the asymmetry, measurements in three phases were used, which requires modification of the measurement system.
Źródło:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej; 2019, 62; 105-108
1425-5766
2353-1290
Pojawia się w:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Budowa modelu symulacyjnego regulatora przełączników zaczepów transformatora WN/SN - kompensacja prądowa
Construction of a Simulation Model of the HV/MV Transformer Tap Changer Controller - Current Compensation
Autorzy:
Korpikiewicz, J. G.
Powiązania:
https://bibliotekanauki.pl/articles/277841.pdf
Data publikacji:
2018
Wydawca:
Sieć Badawcza Łukasiewicz - Przemysłowy Instytut Automatyki i Pomiarów
Tematy:
model symulacyjny regulatora przełącznika zaczepów
regulacja napięcia w sieci SN
kompensacja prądowa
simulation model of the tap-changer controller
voltage regulation in the MV network
current compensation
Opis:
W artykule poruszono problem realizacji kompensacji prądowej w regulatorach przełączników zaczepów transformatora. Przedstawiono strukturę regulatora przełącznika zaczepów transformatora WN/SN. Szczegółowo opisano układ pomiarowy wraz z układem kompensacji prądowej. Zaproponowano nową realizację kompensacji prądowej. Utworzono w środowisku MATLAB/Simulink model symulacyjny analizowanej części regulatora do testów. Zaprezentowano wyniki testów potwierdzające poprawność pracy utworzonego modelu. Zaproponowano koncepcję nowej metody kompensacji prądowej uwzględniającą pomiary trójfazowej sieci elektroenergetycznej.
The article presents the structure of the HV/MV transformer tap changer controller. All blocks of the regulator are described. The measuring system with the current compensation circuit is described in detail. A model was created in Simulink of the analyzed part of the regulator. Simplifications introduced – no block detection of the voltage correctness measurement. A simulation scheme was created to test the developed Simulink model. The results of tests confirming the correctness of the work of the created model are presented. The concept of a new method of current compensation considering the measurements of a three-phase power grid has been proposed.
Źródło:
Pomiary Automatyka Robotyka; 2018, 22, 4; 51-59
1427-9126
Pojawia się w:
Pomiary Automatyka Robotyka
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
A complex current ratio device for the calibration of current transformer test sets.
Autorzy:
Çayci, H.
Powiązania:
https://bibliotekanauki.pl/articles/221001.pdf
Data publikacji:
2011
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
current transformer test set
ratio error
phase displacement
current comparator
compensation
Opis:
A practical method with high accuracy in generation and application of error values for calibration of current transformer test sets is described. A PC-controlled three-phase power source with a standard wattmeter is used for generating the nominal and error test currents while an electronically compensated current comparator is used to provide summation and subtraction of them, precisely. With this method, any ratio error and phase displacement values could be generated automatically and nominal and test currents could be grounded on the test set safely. Because of its high accurate ratio and phase error generating capability, any type of test set regardless of its operating principles could be calibrated.
Źródło:
Metrology and Measurement Systems; 2011, 18, 1; 159-164
0860-8229
Pojawia się w:
Metrology and Measurement Systems
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
A study on the effect of harmonie components of the current supplying an induction motor with reactive power compensation with the use of capacitors on the power loss and voltage variations
Autorzy:
Nawrowski, R.
Stein, Z.
Zieliński, M.
Powiązania:
https://bibliotekanauki.pl/articles/97224.pdf
Data publikacji:
2014
Wydawca:
Politechnika Poznańska. Wydawnictwo Politechniki Poznańskiej
Tematy:
induction motor
current and voltage harmonics
power loss compensation
Opis:
The paper presents an analysis of the effect of voltage harmonics on the power loss in an LV line supplying an induction motor with reactive power compensation, with the use of capacitors, and analysis of the values of output voltage of an MV/LV transformer depending on the load type and value.
Źródło:
Computer Applications in Electrical Engineering; 2014, 12; 275-287
1508-4248
Pojawia się w:
Computer Applications in Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
A new active method of protection against electrical shock in low voltage ship networks: experimental results
Nowa aktywna metoda ochrony przeciwporażeniowej w sieciach okrętowych niskiego napięcia: badania eksperymentalne
Autorzy:
Tarnapowicz, D.
Powiązania:
https://bibliotekanauki.pl/articles/256131.pdf
Data publikacji:
2008
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Technologii Eksploatacji - Państwowy Instytut Badawczy
Tematy:
ochrona przeciwporażeniowa
kompensacja parametryczna
kompensacja aktywna
falownik czteroprzewodowy
protection against shock current
parametric compensation
active compensation
four-leg inverter
Opis:
The commonly applied electrical networks with an insulated neutral point in ships are not able to protect against electric shock, due to the presence of capacitance between phase wires and the hull, which increases the values of shock current. A new approach to solve this problem is presented. The new idea is based on active compensation of shock current using current sources inserted between the phase wires and the metallic hull. A four-leg transistor inverter controlled by a signal processor (DSP) and a logic programmable array (FPGA) was used as a set of current sources. The arrangement of the test stand obtained for the experimental checking of the concept compensation of shock current is presented together with the experimental results.
Powszechnie stosowane w okrętownictwie sieci elektryczne z izolowanym punktem zerowym z powodu występowania pojemności doziemnych (powodujących wzrost prądu rażenia) nie zapewniają ochrony przeciwporażeniowej. Autor prezentuje nowe podejście do rozwiązania tego problemu. Nowa idea aktywnej kompensacji prądu rażenia człowieka polega na włączaniu pomiędzy przewody fazowe a kadłub statku aktywnych źródeł prądu. W proponowanym rozwiązaniu jako źródła prądowe został wykorzystany falownik w układzie czteroprzewodowym. W referacie przedstawiono układ stanowiska badawczego, przeznaczonego do eksperymentalnego sprawdzenia koncepcji aktywnej kompensacji prądu rażenia w sieciach okrętowych niskiego napięcia, oraz wyniki badań.
Źródło:
Problemy Eksploatacji; 2008, 1; 137-145
1232-9312
Pojawia się w:
Problemy Eksploatacji
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Current limiting algorithm for three-phase grid-connected inverters
Autorzy:
Tran, Tho Quang
Powiązania:
https://bibliotekanauki.pl/articles/2135740.pdf
Data publikacji:
2022
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
current limitation
negative sequences
reactive power compensation
three-phase grid-connected inverter
unbalanced voltages
Opis:
Grid-connected inverters are commonly used in systems of renewable energy to convert this energy source into AC power with parameters suitable for connection to the grid. In the normal operating conditions, the grid-connected inverters mainly generate active power to the grid. However, when a voltage sag or voltage imbalance occurs, the grid voltage imbalance in the conventional control methods causes negative sequence components and increases the output current magnitude of inverters. The increase of current can damage power semiconductor devices. This paper presents a strategy to limit the current magnitude of inverters under unbalanced grid voltage conditions. In this strategy, a multiple-complex-coefficient filter is used to eliminate the negative sequence voltage components. This method does not require any additional hardware. A three-phase gridconnected photovoltaic inverter system using a solar array of 20 kWp is also used for the survey. The effectiveness has been validated when comparing the simulation results on Matlab/Simulink of the proposed method with those of the conventional method.
Źródło:
Archives of Electrical Engineering; 2022, 71, 3; 559--579
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Conductance-controlled global-compensation-type shunt active power filter
Autorzy:
Szromba, A.
Powiązania:
https://bibliotekanauki.pl/articles/140436.pdf
Data publikacji:
2015
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
shunt active power filter
active current
indirect control method
instantaneous compensation
load equivalent conductance
energy flow control
Opis:
This paper presents a load equivalent conductance based control method for a shunt active power filter. The principle of energy balance in the circuit, which means between supplying source - active filter - load, is used to obtain the control formula. The natural inertia of the active filter action is exploited, so no PI regulators are needed. The active filter can compensate for non-active current and, additionally, can stabilise the supplying source active power. In a case of generating loads energy harvesting is possible. The presented method is useful as well for voltage-source as current-source inverter based active filters, and for DC system as well as for AC single- or three-phase one.
Źródło:
Archives of Electrical Engineering; 2015, 64, 2; 259-275
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Charakter prawny roszczeń podmiotów prowadzących szkoły I placówki niepubliczne w zakresie dotacji oświatowych
Legal nature of claims of entities running schools and non-public institutions in terms of educational subsidies
Autorzy:
Zdziebło, Mateusz
Powiązania:
https://bibliotekanauki.pl/articles/2054206.pdf
Data publikacji:
2021-09-02
Wydawca:
Wyższa Szkoła Humanitas
Tematy:
dotacja oświatowa
roszczenie o odszkodowanie
zobowiązanie
wydatki bieżące
szkoda
educational subsidy
claim for compensation
obligation
current expenditure
damages
Opis:
Dotacje oświatowe pełnią ważną rolę w realizacji zadań związanych z procesem kształcenia i wypłacane są podmiotom prywatnym, które prowadzą niepubliczne szkoły i placówki. Doświadczenia ostatnich lat pokazują częste przypadki nieprawidłowości w obliczaniu kwot dotacji przez organy jednostek samorządu terytorialnego, co prowadziło do wstępowania na drogę sądową przez podmioty prowadzące szkoły i placówki niepubliczne. W niniejszym opracowaniu poddano analizie podstawy prawne roszczeń podmiotów prywatnych dotyczących dotacji, związanych z nienależytym określeniem ich wysokości przez samorządy. Roszczenie dotyczące dotacji może być oparte na różnych podstawach prawnych i przybierać postać roszczenia o wykonanie zobowiązania, roszczenia o odszkodowanie na podstawie odpowiedzialności deliktowej i kontraktowej. Wybór określonej podstawy prawnej niesie ze sobą dalsze konsekwencje dla podmiotów prowadzących szkoły i placówki niepubliczne. Dochodzenie roszczenia dotyczącego dotacji jako roszczenia o wykonanie zobowiązania rodzi problem związany z ewentualnym rozliczeniem należności uzyskanych tytułem dotacji, a wypłaconych po upływie okresu rozliczeniowego. Z kolei dochodzenie roszczenia o odszkodowanie wiąże się z trudnościami w zakresie sposobu ustalenia szkody.
Educational subsidies play an important role in the implementation of tasks related to the education process and are paid to private entities that run non-public schools and institutions. The experience of recent years shows frequent cases of irregularities in the calculation of grant amounts by local government units, which led to legal action by entities running schools and non-public institutions. This study analyses the legal grounds for claims by private entities regarding subsidies related to improper determination of their amount by local governments. A grant claim may be based on various legal bases and may take the form of a performance claim, a claim for damages based on tort and contractual liability. The choice of a specific legal basis carries further consequences for entities running schools and non-public institutions. Pursuing a claim regarding a subsidy as a claim for performance of an obligation raises a problem related to the possible settlement of receivables obtained as subsidies and paid after the settlement period. On the other hand, pursuing a claim for damages is associated with difficulties in the manner of determining the damage.
Źródło:
Roczniki Administracji i Prawa; 2021, 1, XXI; 45-59
1644-9126
Pojawia się w:
Roczniki Administracji i Prawa
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Problemy kačestva èlektrosnabženiâ promyšlennyh potrebitelej ot obmotki srednego naprâženiâ tâgovyh podstancij peremennogo toka
Problemy jakości zasilania konsumentów przemysłowych z uzwojenia średniego napięcia podstacji trakcyjnych prądu przemiennego
The Problems of Power Quality for Industrial Consumers Fed on the Medium-voltage Winding from AC Traction
Autorzy:
Bosyj, D. A.
Powiązania:
https://bibliotekanauki.pl/articles/215440.pdf
Data publikacji:
2014
Wydawca:
Instytut Kolejnictwa
Tematy:
podstacja trakcyjna
prąd zmienny
napięcie
asymetria
moc bierna
kompensacja
traction substation
alternating current
voltage
unbalance
reactive power
compensation
Opis:
W pracy podstacji trakcyjnych prądu zmiennego może występować znaczące pogorszenie jakości energii elektrycznej. Z powodu obniżenia jakości energii elektrycznej, straty ponoszą przede wszystkim odbiorcy przemysłowi zasilani z uzwojenia średniego napięcia transformatora trakcyjnego. Wyniki przeprowadzonych badań potwierdzają teoretycznie znane problemy z jakością napięcia, a mianowicie zawyżenie napięcia w jednej z faz, róż-nicę napięć na sąsiednich podstacjach, odchylenie trójfazowego układu wektorów napięcia. Analiza znanych metod symetryzacji opartych na zjawisku Scotta wykazała, że założenie o równości kątów obciążenia w odcinkach zasilania, powoduje znaczący błąd w określeniu zjawiska symetryzującego, które nie jest wystarczające do spełnienia wymagań normy w zakresie asymetrii napięć. Zaproponowano rozwiązanie techniczne, które polega na udoskonaleniu urządzeń do ciągłej kompensacji mocy biernej i zapewnia normowaną wartość wskaźnika asymetrii napięcia przy jednoczesnym zmniejszeniu przepływów mocy biernej.
Working of AC traction substations involves significant distortion of the quality of electric energy. First of all, suffer from poor quality of electric power, industrial consumers, which feed on the medium-voltage winding of the traction transformer. Conducted measurements confirm the theory known problems with the quality of voltage that is overstating the voltage in one phase, the difference between the substations, wry three-phase system voltage vectors. Analysis of the known methods of balancing based on the Scott effect showed that the assumption of the equality of the angles at the shoulders load power is making a significant error in the determination of the symmetry effect, which is not enough to ensure the standard requirements regarding voltage unbalance. The proposed solution, which is to improve the devices continuously reactive power compensation and allows normal coefficient of voltage unbalance simultaneously with a reduction in reactive power flows.
Źródło:
Problemy Kolejnictwa; 2014, 162; 21-32
0552-2145
2544-9451
Pojawia się w:
Problemy Kolejnictwa
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-14 z 14

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies