Tytuł:
Magnetizing current effect minimization in current transformers
Autorzy:
Dusza, D.
Rzepecki, B.
Powiązania:
https://bibliotekanauki.pl/articles/1813967.pdf
Data publikacji:
2013
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
current transformer
value converter
ratio
error minimization
magnetizing current effect
current transformer's error
current measurement
Opis:
Magnetizing current effect minimization in current transformers is considered in this paper. Double-core current transformer operation is described in the following text. The influence of the magnetizing current, which is a significant element of current transformer's error, has been minimized in a new type of double-core current transformer connection. The accuracy evaluation of built double-core current transformer has been carried out according to obtained transformation precision.
Źródło:
Prace Naukowe Instytutu Maszyn, Napędów i Pomiarów Elektrycznych Politechniki Wrocławskiej. Studia i Materiały; 2013, 69, 33; 469--476
1733-0718
Pojawia się w:
Prace Naukowe Instytutu Maszyn, Napędów i Pomiarów Elektrycznych Politechniki Wrocławskiej. Studia i Materiały
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Inductive current transducers in the frequency range up to 150 kHz
Autorzy:
Kosobudzki, G.
Dusza, D.
Powiązania:
https://bibliotekanauki.pl/articles/1193468.pdf
Data publikacji:
2017
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
current
Rogowski coil
inductive current transducer
Opis:
The article presents the results of the research on inductive current transducers in the form of a uniform winding non-magnetic ring with a rigid and flexible construction encompassing the flow of processed current in the frequency range of up to 150 kHz. The results for the developed transducer were related to the results obtained in simulations conducted on the transducer simplified model. The frequency tests of this type of transducers are of key significance in the assessment of the applicability of a given transducer in the measurements of network signals with high-order harmonics, and particularly in the assessment of the construction capacity of inductive current transducers in the form of the Rogowski coil.
Źródło:
Power Electronics and Drives; 2017, 2, 37/2; 167-176
2451-0262
2543-4292
Pojawia się w:
Power Electronics and Drives
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Current density in the unscreened three-phase high-current busduct
Autorzy:
Szczegielniak, T.
Piątek, Z.
Kusiak, D.
Powiązania:
https://bibliotekanauki.pl/articles/97582.pdf
Data publikacji:
2014
Wydawca:
Politechnika Poznańska. Wydawnictwo Politechniki Poznańskiej
Tematy:
analytical method
high-current busduct
current density
Opis:
Design of the high-current busducts on high currents and voltages causes necessity precise describing of electromagnetic, dynamic and thermal effects. Knowledge of the relations between electrodynamics and constructional parameters is necessary in the optimization construction process of the high-current busducts. Information about distribution electromagnetic field is a base into analysis of electrodynamics and thermal effects in the high-current busducts. The paper presents analytical calculations of the current density in the three-phase high-current busduct which phase conductors are placed in vertex of a square. Into account were taken skin and proximity effect. The electromagnetic field produced by high-current busducts are usually calculated numerically with the use of a computer. However, the analytical calculation of the electromagnetic field is preferable, because it results in a mathematical expression for showing its dependences on various parameters of the line arrangement.
Źródło:
Computer Applications in Electrical Engineering; 2014, 12; 57-64
1508-4248
Pojawia się w:
Computer Applications in Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Multiple output CMOS current amplifier
Autorzy:
Pankiewicz, B.
Powiązania:
https://bibliotekanauki.pl/articles/201141.pdf
Data publikacji:
2016
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
current amplifier
current follower
current mirror
CMOS technology
wzmacniacz prądowy
prąd
technologia CMOS
Opis:
In this paper the multiple output current amplifier basic cell is proposed. The triple output current mirror and current follower circuit are described in detail. The cell consists of a split nMOS differential pair and accompanying biasing current sources. It is suitable for low voltage operation and exhibits highly linear DC response. Through cell devices scaling, not only unity, but also any current gains are achievable. As examples, a current amplifier and bandpass biquad section designed in CMOS TSMC 90nm technology are presented. The current amplifier is powered from a 1.2V supply. MOS transistors scaling was chosen to obtain output gains equal to -2, 1 and 2. Simulated real gains are -1.941, 0.966 and 1.932 respectively. The 3dB passband obtained is above 20MHz, while current consumption is independent of input and output currents and is only 7.77μA. The bandpass biquad section utilises the previously presented amplifier, two capacitors and one resistor, and has a Q factor equal to 4 and pole frequency equal to 100 kHz.
Źródło:
Bulletin of the Polish Academy of Sciences. Technical Sciences; 2016, 64, 2; 301-306
0239-7528
Pojawia się w:
Bulletin of the Polish Academy of Sciences. Technical Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Indukcyjny przetwornik prądu sieciowego ze zworami ferromagnetycznymi
Power line current sensor with ferromagnetic cramps
Autorzy:
Dusza, D.
Nowak, J.
Powiązania:
https://bibliotekanauki.pl/articles/152173.pdf
Data publikacji:
2012
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
prąd
przetwarzanie
przetwornik indukcyjny
current
processing
current sensor
Opis:
W artykule przedstawiono wyniki badań właściwości modeli przetworników prądu sieciowego składających się z cewek cylindrycznych zwartych magnetowodami ferromagnetycznymi. Otrzymane wyniki dowodzą, że można osiągnąć dużą czułość przetwarzania, dobrą liniowość oraz dużą odporność na zakłócenia elektromagnetyczne przetworników charakteryzujących się prostą technologią realizacji. Przetworniki ze zworami ferromagnetycznymi mogą być montowane na przewodach prądowych bez przerywania obwodu prądowego.
The paper deals with an inductive current transducer in the form of cylindrical coils (Fig. 2) with ferromagnetic cramps (Figs. 3 and 4). The investigation results of properties and influence of external magnetic fields on the processing accuracy are presented. They show that it is possible to achieve high sensitivity, good linearity of the transient characteristic (Fig. 6) and high resistance to electromagnetic disturbances (Fig. 5 shows the results for a transducer with four coils, while Fig. 7. for a transducer with two coils). Use of cramps made of permalloy enables obtaining better results (Fig. 8). The proposed solution for current transducer construction is characterized by implementation of simple technology. Transducers with ferromagnetic cramps (ferrite, permalloy, electrical sheet, nanocrystalline materials) can be installed on current wires without breaking a current circuit. Research of the influence of disturbances from external magnetic fields plays a key role in the quality assessment of current transducers.
Źródło:
Pomiary Automatyka Kontrola; 2012, R. 58, nr 11, 11; 981-983
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Differential protection with better stabilization for external faults
Zabezpieczenie różnicowe z lepszą stabilizacją dla zwarć zewnętrznych
Autorzy:
Solak, K.
Rebizant, W.
Powiązania:
https://bibliotekanauki.pl/articles/410581.pdf
Data publikacji:
2011
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
current differential criterion
current transformer
fuzzy logic
saturation
Opis:
This paper presents a new differential protection scheme for transmission lines with application of fuzzy signal processing and support of phase comparison criterion. Traditional differential relays may have problems with proper classification of external faults with CT saturation. Better protection stabilization for such cases is obtained with support of fuzzy signal processing. In proposed solution the input signals as well as the standard percentage characteristic are fuzzified. The performance of presented fuzzy protection scheme has been tested with the signals generated with use of EMTP-ATP program and compared to the traditional solution.
W artykule zaprezentowano nowe zabezpieczenie różnicowe, w którym zastosowano rozmyte przetwarzanie sygnałów oraz dodatkowe kryterium porównawczo-fazowe. Proponowane zabezpieczenie jest bardziej odporne na zwarcia zewnętrzne z nasyceniem przekładników prądowych, co potwierdziły przeprowadzone testy. Proponowany algorytm testowany był na sygnałach pochodzących z symulacji w EMTP-ATP, a wyniki porównano ze standardowym przekaźnikiem różnicowym.
Źródło:
Present Problems of Power System Control; 2011, 1; 39-48
2084-2201
Pojawia się w:
Present Problems of Power System Control
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Parametric-active compensation of earth fault current in an IT-type network
Autorzy:
German-Galkin, S.
Hrynkiewicz, J.
Powiązania:
https://bibliotekanauki.pl/articles/1193299.pdf
Data publikacji:
2017
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
IT-type networks
earth current
fault current compensation
Opis:
The parametric-active compensation of earth leakage currents which minimalized virtual capacitance current in ships of IT-type network has been discussed. The protection is based on automatic compensation of leakage earth currents. The protection system is governed by a controller. The results of simulation tests have been presented. The parametric-active compensation of earth leakage currents which minimalized virtual capacitance current in ships with IT-type network has been discussed.
Źródło:
Power Electronics and Drives; 2017, 2, 37/1; 81-87
2451-0262
2543-4292
Pojawia się w:
Power Electronics and Drives
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Non-Cartesian Frame Transformation-Based Control of a Three-Phase Power Converter During Unbalanced Voltage Dip – Part II: Simulation And Experiment
Autorzy:
Iwański, Grzegorz
Maciejewski, Paweł
Łuszczyk, Tomasz
Powiązania:
https://bibliotekanauki.pl/articles/1193687.pdf
Data publikacji:
2019
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
AC/DC
power conversion
current control
current limitation
Opis:
The paper presents a control method for the three-phase power converter operating under unbalanced grid voltage conditions. The method uses a new transformation to the non-Cartesian frame, which makes the controlled current vector components balanced in this frame even if originally the three-phase current is referenced as unbalanced. Furthermore, Park’s transformation makes the controlled variables constant, which allows to apply proportional–integral terms as current controllers independent of the required control target. Several control targets known from literature have been analyzed with regard to the required new transformation parameters, and the transformation parameters for all targets have been found. Simulation results are shown to prove the theoretical analysis, and the experimental test results are presented as practical validation of the proposed use of the non-Cartesian frame in control.
Źródło:
Power Electronics and Drives; 2019, 4, 39; 63-77
2451-0262
2543-4292
Pojawia się w:
Power Electronics and Drives
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The power electronics controlled current source utilized in the reference current generator
Autorzy:
Gwóźdź, M.
Powiązania:
https://bibliotekanauki.pl/articles/377579.pdf
Data publikacji:
2013
Wydawca:
Politechnika Poznańska. Wydawnictwo Politechniki Poznańskiej
Tematy:
power electronics
current controlled voltage source
current generator
Opis:
The paper considers wide-band voltage controlled power electronics current source. The current source has been designed as a part of 1-channel reference current generator designed for current meters testing. The control module of the generator utilizes specialized Analog Devices Inc. DSPs based microcomputer module for power electronics applications. Used solutions have allowed obtain high quality referencing of the output current within reference signal. The paper presents the structure and selected aspects of the control algorithm of the current source. Also selected investigations results of laboratory prototype of generator with utilization of controlled current source are presented.
Źródło:
Poznan University of Technology Academic Journals. Electrical Engineering; 2013, 76; 9-14
1897-0737
Pojawia się w:
Poznan University of Technology Academic Journals. Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Klimatyczny wskaźnik aktywności Prądu Labradorskiego
Climatic index of Labrador Current activity
Autorzy:
Marsz, A. A.
Powiązania:
https://bibliotekanauki.pl/articles/260933.pdf
Data publikacji:
2003
Wydawca:
Stowarzyszenie Klimatologów Polskich
Tematy:
prądy morskie
Prąd Labradorski
sea current
Labrador Current
Opis:
Some of the sea currents show strong activity in climate formation and this fact is well known. Their activity represented as a time function is not stable but proves to be changeable. For this reason it seems quite reasonable to introduce appropriate indexes which could be used to characte-rise activity of a given current and, in an indirect way, to describe heat masses carried with this current. The aim of this article is to present an index which characterises the climatic activity of the Labrador Current. The basis to create such an index is the number of icebergs carried with this current. In consecutive ice seasons (October - September) this number passed south of 48°N of E from New Foundland (data from ?International Ice Patrol?). Changeable from year to year number of icebergs carried to the North Atlantic (see fig. 2) primarily represents the increase or decrease in the intensity of the Labrador Current. As the number of icebergs moved to the Atlantic comprises random component, which is very high, in order to create the index a logarythm was used to reduce the changeability of the amplitude. Formula [ 1 ] has been proposed to be used to calculate the index of intensity of the Labrador Current (WPL): WPL= (ln(G + 1))/2 where: ln - natural logarythm (base = e), G - the number of icebergs noted in a given ice season. Values of WPL index calculated in this way dated in January in ice season over a period 1900?2002 have been presented in Table 2 and their course in Fig. 3. The value of WPL indicates quite strong correlation with both winter (DJFM) and annual NAO indexes (r ~ 0.5), however the analysis showed that NAO is not the only element having influence on the Labrador Current activity. The analysis, carried out at random, of relations between the values of WPL and different climatic and hydroclimatic elements indicated to the fact that most of the relations are shifted/delayed in time - changeability of WPL takes place earlier than changes in these elements. For instance, the air temperature in August the following year in most area of Poland proves to have not too strong but clear correlation with the changes in WPL. Numerous correlations between WPL and occurring later monthly values of air temperature and monthly sums of precipitation at stations in the Atlantic sector of Arctica have been observed. The size of sea ice cover in the Barents Sea in the following year has shown especially high correlation with the changeability of WPL (the changeability of WPL explains ~50% of changeability in the area of the sea ice cover of the Barents Sea in January the following year). In this way WPL seems to be potentially useful in long term predictors of weather forecasts. The delayed activity of WPL can be explained by means of the following cause- and-effect chain of actions: winter (DJFM) atmpspheric circulation over the Davis Strait and the Labrador Sea has influence on the activity of the Labrador Current - the activity of the Labrador Current has influence on the extent and size of the anomalies in SST in the Labrador Sea and in NW part of the Atlantic (MJJA) - the presence of such anomalies in SST has a modifying effect on the atmospheric circulation occurring in the following autumn (SON) and winter (DJFM).
Źródło:
Problemy Klimatologii Polarnej; 2003, 13; 43-58
1234-0715
Pojawia się w:
Problemy Klimatologii Polarnej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
A comparison of the metrological properties of two-core current transformers
Porównanie właściwości metrologicznych dwurdzeniowych przekładników prądowych
Autorzy:
Dusza, D.
Powiązania:
https://bibliotekanauki.pl/articles/156954.pdf
Data publikacji:
2014
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
current
processing
current transducer
prąd
przetwarzanie
przekładnik prądowy
Opis:
The paper presents a comparative analysis of the two-core Brooks and Brooks &Holtz transformers used in precision measuring systems. The derived relations indicate that the two-core Brooks & Holtz transformer has much better metrological properties. The metrological analysis was verified by the results of tests carried out on standard transformers. The analysis and the results can be used in the design of two-core transformers.
W artykule przedstawiono porównanie właściwości metrologicznych przekładników prądowych Brooksa oraz Brooksa i Holtza [3]. W rozdziale 2.1 przedstawiono przekładnik jednordzeniowy, którego błąd opisano za pomocą impedancji jego obwodu zastępczego (rys. 1b). W rozdziale 2.2 pokazano schemat zastępczy przekładnika Brooksa i na tej podstawie wyprowadzono wzór (2) określający błąd przekładnika. Przy założeniu (3) uproszczono wzór (2) do postaci (5), z którego wynika, że błąd przekładnika zależy głównie od impedancji obciążenia. Pokazano również wpływ błędu przekładnika pomocniczego ACIT (6) na błąd przetwarzania przekładnika Brooksa. Ze wzoru (10) wynika, że magnetowód przekładnika pomocniczego powinien być wykonany z materiału ferromagnetycznego o dużej wartości przenikalności początkowej, tj. permaloj, taśma amorficzna. W rozdziale 2.3 pokazano strukturę i analizę przekładnika Brooksa i Holtza. Z analizy wynika, że przekładnik ten powinien charakteryzować się lepszymi parametrami metrologicznymi, niż przekładnik Brooksa i Holtza, ponieważ w równaniu występuje iloczyn błędów przekładnika głównego i pomocniczego. W rozdziale 3 pokazano zastosowane układy pomiarowe do wyznaczania błędów przekładnika Brooksa (rys. 4) oraz Brooksa i Holtza (rys.5), które realizują metodę kompensacyjno-różnicową. W rozdziale 4 przedstawiono wyniki badań dla błędów prądowych i kątowych. Z otrzymanych wyników badań określono klasę przekładnika Brooksa jako 0,5 oraz dla połączenia Brooksa i Holtza 0,05.
Źródło:
Pomiary Automatyka Kontrola; 2014, R. 60, nr 8, 8; 568-572
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Comparative Measurements on Loudspeaker Distortion: Current vs. Voltage Control
Autorzy:
Meriläinen, E.
Powiązania:
https://bibliotekanauki.pl/articles/176516.pdf
Data publikacji:
2017
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
current driving
current control
loudspeaker distortion
current distortion
inductance non-linearity
voice coil former
Opis:
Modulation and harmonic distortion produced by ordinary moving-coil direct-radiator drive units are measured under current control and voltage control. A realistic two-tone test signal is used to investigate the detrimental effect of the voice coil electromotive forces on the voltage-to-current conversion that is critical with voltage control. Dramatic improvements in distortion performance are obtained with current control. Current nonlinearities in voltage-controlled speakers are shown to be the dominant source of modulation and odd harmonic distortions at signal frequencies above the fundamental resonance region. Currents in conductive voice coil formers also seem to be significant sources of distortion; with current control and non-conductive formers, odd harmonics and related modulation products virtually vanished in the upper midrange.
Źródło:
Archives of Acoustics; 2017, 42, 1; 71-81
0137-5075
Pojawia się w:
Archives of Acoustics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Verification of the value of leakage current amperage of a rod insulator surface determined using an electric model of its surface percolation
Autorzy:
Frączak, P.
Powiązania:
https://bibliotekanauki.pl/articles/97353.pdf
Data publikacji:
2016
Wydawca:
Politechnika Poznańska. Wydawnictwo Politechniki Poznańskiej
Tematy:
insulator percolation current amperage
insulator percolation current amperage verification
Opis:
This work presents simulation of calculations related to the value of leakage current amperage on a porcelain surface of a rod insulator performed using the percolation theory. Surface of a rod insulator has been presented in the percolation model for grid nodes. This model is an electric circuit which includes a resistance grid and a power (voltage) source. This model includes a randomised method of “filled” node creation within the grid. The procedure of simulation calculations of the leakage current amperage using the percolation model included creation of its equivalent circuit and declaration of appropriate current analysis in the PSpice program. Thus obtained values of leakage current on amperage the surface of a rod insulator were compared with values measured on insulators studied at the testing station. Similar values of leakage current amperage on surfaces of insulators were obtained in simulation calculations (for the percolation theory), and in actual measurements at the testing station.
Źródło:
Computer Applications in Electrical Engineering; 2016, 14; 201-209
1508-4248
Pojawia się w:
Computer Applications in Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Design and test of a new high-current electronic current transformer with a Rogowski coil
Autorzy:
Zhang, M.
Li, K.
He, S.
Wang, J.
Powiązania:
https://bibliotekanauki.pl/articles/221051.pdf
Data publikacji:
2014
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
Rogowski coil
high-current
electronic current transformers
electrical measurements
Opis:
This paper describes the design and test of a new high-current electronic current transformer based on a Rogowski coil. For better performances, electronic current transformers are used to replace conventional electro-magnetic inductive current transformers based on ferromagnetic cores and windings to measure high-current on the high voltage distribution grids. The design of a new high-current electronic current transformer is described in this paper. The principal schemes of the prototype and partial evaluation results are presented. Through relative tests it is known that the prototype has a wide dynamic range and frequency band, and it can allow high accuracy measurements.
Źródło:
Metrology and Measurement Systems; 2014, 21, 1; 121-132
0860-8229
Pojawia się w:
Metrology and Measurement Systems
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Research on optimal configuration of fault current limiter based on reliability in large power network
Autorzy:
Zeng, Jianjun
Zhang, Yonggao
Powiązania:
https://bibliotekanauki.pl/articles/949918.pdf
Data publikacji:
2020
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
configuration optimization
fault current limiter
reliability
short circuit current
Opis:
With the availability of UHV engineering technology, the scale of the power network is expanding, and the level of the short-circuit current is getting higher, which brings hidden trouble to the safe and stable operation of the power network. Further this article issued a method that optimized the configuration of a current limiter based on the reliability of the power network. According to the reliability analysis under the influence of a short circuit, the quantitative evaluation of reliability of the power network is realized by the calculation of the short-circuit current. A quantitative model is established among reliability evaluation and the short-circuit current as well as load loss, the candidate installation site of a current limiter can be determined according to reliability quantification results. This method uses the particle swarm optimization algorithm to optimize the distribution of the limiter, aiming at the reliability level and the minimum number of current limiters in the short circuit of a power grid. Finally, taking the actual power grid of a province as an example, the result shows that this method can reduce the search space of the optimal solution, optimize the configuration of the current limiter, and effectively limit the short-circuit current and improve the reliability of the power network.
Źródło:
Archives of Electrical Engineering; 2020, 69, 3; 661-677
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Currents circulation in the waters of Admiralty Bay (region of Arctowski Station on King George Island)
Autorzy:
Pruszak, Zbigniew
Powiązania:
https://bibliotekanauki.pl/articles/2058278.pdf
Data publikacji:
1980
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
Antarctic
current circulation
Źródło:
Polish Polar Research; 1980, 1, 1; 55-74
0138-0338
2081-8262
Pojawia się w:
Polish Polar Research
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Nowy model elektronicznego przekładnika prądowego z kompensacją strumienia magnetycznego w rdzeniu
A new electronic transducer model with magnetic flux compensation in magnetic core
Autorzy:
Piwowarczyk, J.
Pacholski, K.
Powiązania:
https://bibliotekanauki.pl/articles/156292.pdf
Data publikacji:
2007
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
elektroniczny przekładnik prądowy
pomiar prądu
electronic current transducer
current measurement
Opis:
Przedstawiono nowy model elektronicznego przekładnika prądowego. Punktem wyjścia do realizacji tego modelu był model konwencjonalnego przekładnika prądowego, który połączono następnie z modelem bloku elektroniki. Tego typu podejście odzwierciedla budowę rzeczywistego układu. Parametry modelu elektronicznego przekładnika prądowego uzależniono od pulsacji sygnału mierzonego. Pozwoliło to nie tylko na analizę właściwości metrologicznych obiektu badań, ale i również na wyznaczenie częstotliwości ograniczającej od góry częstotliwościowe pasmo przetwarzania bloku elektronicznego. Autorzy dokonali weryfikacji nowego modelu przetwornika w trakcie badań laboratoryjnych.
The paper describes new electronic current transducer model. Starting point during constructing the new model was the model of typical current transducer that was connected to the electronic model block. Such solution reflect to the real object. The parameters of the electronic current transducer model were combined with pulsation of the primary signal. It allowed to analyse metrological properties of the object as well as to determine upper frequency, that limits electronic block work. Authors performed verification of the new transducer model during laboratory research.
Źródło:
Pomiary Automatyka Kontrola; 2007, R. 53, nr 9 bis, 9 bis; 669-672
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Investigations of Topographic effect on radial current in South Yellow Sea
Autorzy:
Chen, C.
Wang, Y.
Huang, H.
Powiązania:
https://bibliotekanauki.pl/articles/259574.pdf
Data publikacji:
2017
Wydawca:
Politechnika Gdańska. Wydział Inżynierii Mechanicznej i Okrętownictwa
Tematy:
field survey
numerical model
topography
radial current
lagrangian residual current
Opis:
Large scaled projects are conducted in South Yellow Sea in recent years. Topographic effect and tidal current are key issues to the coastal engineering and the ocean engineering. In this study, field surveys were conducted to investigate the tidal level, current velocity, and current direction in South Yellow Sea. A numerical model was developed to simulate the radial current field based on the field data. To investigate the mechanism of the radial current field, the actual topography and a smoothed topography were applied in the numerical model, respectively. Results show that, the current field appeares radial because of the tidal system rather than the submarine topography. Local topography centralized the radiation centre and shifted the high-velocity zones. The actual topographic effect is proposed, and results show that local topography increases the flood tide velocity and decreases the ebb tide velocity. Lagrangian residual currents are calculated to illustrate possible sediment sources and transport routes.
Źródło:
Polish Maritime Research; 2017, S 3; 123-129
1233-2585
Pojawia się w:
Polish Maritime Research
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Jednofazowe wyłączanie zwarć trójfazowych za pomocą bezstykowego ogranicznika prądów zwarciowych
The application of the contactless current limiter to single-phase switching off a three-phase fault arc
Autorzy:
Leśniewski, P.
Powiązania:
https://bibliotekanauki.pl/articles/268654.pdf
Data publikacji:
2012
Wydawca:
Politechnika Gdańska. Wydział Elektrotechniki i Automatyki
Tematy:
bezstykowy ogranicznik prądu zwarciowego
zwarcia łukowe
ograniczniki prądu
current limiting
contactless current limiter
fault arc
current limiter
Opis:
W artykule przedstawiono działanie bezstykowego ogranicznika prądów zwarciowych (CHCL). Bezpiecznik krótkotopikowy stanowi główny tor prądowy ogranicznika, a jego charakterystyki decydują o własnościach CHCL. Omówiono również wyniki modelowania matematycznego wyłączania 3-fazowych zwarć łukowych w rozdzielnicach niskonapięciowych za pomocą aparatów umieszczanych jedynie w środkowej fazie płaskiego układu szyn zbiorczych. Jako aparaty wyłączające stosowano: bezpieczniki oraz łączniki hybrydowe, szczególną uwagę zwracając na możliwość zastąpienia wyłącznika WACH ogranicznikiem CHCL. Po wyłączeniu w środkowej fazie 3-fazowe zwarcie łukowe przechodzi w zwarcie 2-fazowe, z łukiem palącym się między fazami skrajnymi. Zwarcia 2-fazowe, na skutek samoistnego gaśnięcia łuku przy najbliższym przejściu prądu przez zero, wyłączają się samoczynnie.
A new idea of a hybrid contactless current limiter and the properties of existing current limiter are discussed. On the substitution of a special ultra-short fuse for a contact switch in the hybrid current limiter a new device has been obtained, suitable for fast short-circuit fault cleaning. Experimental investigations carried out, of the fault arc in 3-phase l.v. switchboards show that it is possible to interrupt this fault by means of 1-phase interrupting apparatus. As a protective apparatus a fuse or circuit-breaker placed only in one central bar was used. After switching off the feeding by this fuse of the bar, the short-circuit goes into a 2-phase arcing fault between the outermost bars. Then this open arc is interrupted finally by the quenching at its natural current nearest to zero.
Źródło:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej; 2012, 31; 93-96
1425-5766
2353-1290
Pojawia się w:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Przetworniki pomiarowe prądu w urządzeniach zabezpieczeń nadprądowych
Current transducers for over current protecting devices
Autorzy:
Czucha, J.
Powiązania:
https://bibliotekanauki.pl/articles/154043.pdf
Data publikacji:
2007
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
przetworniki pomiarowe prądu
zabezpieczenia prądowe
current transducers
over current protecting devices
Opis:
Przeprowadzono analizę charakterystyk kilku typów przetworników pomiarowych prądu stosowanych w technice zabezpieczeń prądowych. Wykazano, że rozrzut charakterystyk dynamicznych "klasycznych" przetworników opartych na detekcji cieplnych skutków prądu jest bardzo duży. Również boczniki rezystancyjne i przekładniki prądowe indukcyjne w warunkach szybkich zmian prądu wnoszą wielki błąd pomiarowy, osiągający nawet kilkadziesiąt procent. Ze względu na szerokie pasmo przenoszenia coraz częściej stosowane są przetworniki z półprzewodnikowym czujnikiem Halla i dla pomiaru wielkich wartości prądów zmiennych, o bardzo dużej stromości zmian, układy z cewkami Rogowskiego.
In the paper, properties of various current transducers for overcurrent protecting devices are analysed. It is noticeable that dynamic characteristics of classical transducers based upon current thermal effects are broadly dispersed. Resistive shunts and instrument transformers may generate significant errors approaching even several tens percent. More and more frequently transducers comprising Hall sensors are applied due to their wide-band signal transmission in circuits with high rate of current rise Rogowski coils are used.
Źródło:
Pomiary Automatyka Kontrola; 2007, R. 53, nr 4, 4; 94-97
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
A complex current ratio device for the calibration of current transformer test sets.
Autorzy:
Çayci, H.
Powiązania:
https://bibliotekanauki.pl/articles/221001.pdf
Data publikacji:
2011
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
current transformer test set
ratio error
phase displacement
current comparator
compensation
Opis:
A practical method with high accuracy in generation and application of error values for calibration of current transformer test sets is described. A PC-controlled three-phase power source with a standard wattmeter is used for generating the nominal and error test currents while an electronically compensated current comparator is used to provide summation and subtraction of them, precisely. With this method, any ratio error and phase displacement values could be generated automatically and nominal and test currents could be grounded on the test set safely. Because of its high accurate ratio and phase error generating capability, any type of test set regardless of its operating principles could be calibrated.
Źródło:
Metrology and Measurement Systems; 2011, 18, 1; 159-164
0860-8229
Pojawia się w:
Metrology and Measurement Systems
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Tilt-shift eddy current probe impact on information value of response signal
Autorzy:
Chudacik, V.
Smetana, M.
Powiązania:
https://bibliotekanauki.pl/articles/140578.pdf
Data publikacji:
2016
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
eddy current testing
eddy current probe
response signals
tilt-shift probe
Opis:
This article deals with the possibility for increasing of the informational value of a response signal using tilt-shift eddy current probe. Numerical simulations based on the FEM method using the OPERA 3D software as well as gained experimental results are presented. The simulated cracks are evaluated at the selected eddy current probe tilts and shifts with respect to conductive plate to obtain additional data needed for its evaluation and localization. Obtained simulation results are compared and discussed with the experimental results.
Źródło:
Archives of Electrical Engineering; 2016, 65, 1; 133-140
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analiza prądu załączania transformatora
Analysis of transformer inrush current
Autorzy:
Horiszny, J.
Powiązania:
https://bibliotekanauki.pl/articles/153852.pdf
Data publikacji:
2007
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
transformator
prąd włączania
charakterystyka magnesowania
transformer
inrush current
flux-current characteristic
Opis:
Włączenie zasilania nieobciążonego transformatora może spowodować pobór prądu osiągającego znaczną wartość szczytową, przekraczającą wielokrotnie wartość znamionową. W artykule przedstawiono opis analityczny tego zjawiska. Analizę przeprowadzono w oparciu o zlinearyzowaną charakterystykę magnesowania rdzenia transformatora. Pozwoliło to na uzyskanie niezbyt skomplikowanych zależności opisujących przebiegi prądu włączania i strumienia magnetycznego. Na tej podstawie określono wpływ takich czynników, jak moment włączenia napięcia, charakter obwodu pierwotnego i stopień namagnesowania rdzenia na przebieg i wartość maksymalną prądu.
Energization of a transformer with no load is always accompanied by an inrush current. Peak of the current may be several times higher then its rated value. An analytical approach to the phenomenon is presented in the article. The analysis was carried out basing on piecewise linear flux-current characteristic. This resulted in obtaining simple formulas to describe variations of inrush current and magnetic flux. Basing on these the influence of several factors (including: time of switching on of the voltage, circuit inductance, residual flux of the core) upon variation and maximal value of current was determined.
Źródło:
Pomiary Automatyka Kontrola; 2007, R. 53, nr 4, 4; 139-141
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Stanowisko pomiarowe do wyznaczania różnicowego prądu wyłączania wyłączników różnicowo-prądowych typu AC
Autorzy:
Kidawa, A.
Głaz, J.
Powiązania:
https://bibliotekanauki.pl/articles/370912.pdf
Data publikacji:
2008
Wydawca:
Wyższa Szkoła Zarządzania Ochroną Pracy w Katowicach
Tematy:
prąd różnicowy
wyłączniki różnicowo-prądowe
current differential
Residual current circuit breakers
Źródło:
Zeszyty Naukowe Wyższej Szkoły Zarządzania Ochroną Pracy w Katowicach; 2008, 1(4); 91-95
1895-3794
2300-0376
Pojawia się w:
Zeszyty Naukowe Wyższej Szkoły Zarządzania Ochroną Pracy w Katowicach
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
An evaluation method of observable charge trap depth for the PEA method and its complementarity with the Q(t) method
Autorzy:
Ren, Hanwen
Takada, Tatsuo
Tanaka, Yasuhiro
Li, Qingmin
Powiązania:
https://bibliotekanauki.pl/articles/1848995.pdf
Data publikacji:
2021
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
pulsed electroacoustic method
trap depth
current integration charge method
leakage current
Opis:
This paper proposes an evaluation method for the observable trap depth range of space charge when using the pulsed electro-acoustic (PEA) method and its complementarity with the current integration charge (Q(t)) method. Based on the measurement process of the PEA method and the hopping conduction principle of space charge, the relationship between the trap depth and the residence time of charge is analysed. A method to analyse the effect of the measurement speed and the spatial resolution of the PEA system on the observable trap depth is then proposed. Further results show when the single measurement time needs 1 s and the resolution is 10 μm at room temperature, the corresponding trap depth is larger than 0.68 eV. Meanwhile, under high temperature or with voltage applied, the depth can further increase. The combined measurement results of the PEA and Q(t) methods indicate that the former focuses on charge distribution in deep traps, which allows to calculate the distorted electric field. The latter can measure the changing process of the total charge involved in all traps, which is applicable to analysing the leakage current. Therefore, the evaluation of HVDC insulation properties based on the joint application of the two methods is more reliable.
Źródło:
Metrology and Measurement Systems; 2021, 28, 3; 565-580
0860-8229
Pojawia się w:
Metrology and Measurement Systems
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
An evaluation method of observable charge trap depth for the PEA method and its complementarity with the Q(t) method
Autorzy:
Ren, Hanwen
Takada, Tatsuo
Tanaka, Yasuhiro
Li, Qingmin
Powiązania:
https://bibliotekanauki.pl/articles/1849041.pdf
Data publikacji:
2021
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
pulsed electroacoustic method
trap depth
current integration charge method
leakage current
Opis:
This paper proposes an evaluation method for the observable trap depth range of space charge when using the pulsed electro-acoustic (PEA) method and its complementarity with the current integration charge (Q(t)) method. Based on the measurement process of the PEA method and the hopping conduction principle of space charge, the relationship between the trap depth and the residence time of charge is analysed. A method to analyse the effect of the measurement speed and the spatial resolution of the PEA system on the observable trap depth is then proposed. Further results show when the single measurement time needs 1 s and the resolution is 10 μm at room temperature, the corresponding trap depth is larger than 0.68 eV. Meanwhile, under high temperature or with voltage applied, the depth can further increase. The combined measurement results of the PEA and Q(t) methods indicate that the former focuses on charge distribution in deep traps, which allows to calculate the distorted electric field. The latter can measure the changing process of the total charge involved in all traps, which is applicable to analysing the leakage current. Therefore, the evaluation of HVDC insulation properties based on the joint application of the two methods is more reliable.
Źródło:
Metrology and Measurement Systems; 2021, 28, 3; 565-580
0860-8229
Pojawia się w:
Metrology and Measurement Systems
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
An evaluation method of observable charge trap depth for the pea method and its complementarity with the Q(t) method
Autorzy:
Ren, Hanwen
Takada, Tatsuo
Tanaka, Yasuhiro
Li, Qingmin
Powiązania:
https://bibliotekanauki.pl/articles/1849058.pdf
Data publikacji:
2021
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
pulsed electroacoustic method
trap depth
current integration charge method
leakage current
Opis:
This paper proposes an evaluation method for the observable trap depth range of space charge when using the pulsed electro-acoustic (PEA) method and its complementarity with the current integration charge (Q(t)) method. Based on the measurement process of the PEA method and the hopping conduction principle of space charge, the relationship between the trap depth and the residence time of charge is analysed. A method to analyse the effect of the measurement speed and the spatial resolution of the PEA system on the observable trap depth is then proposed. Further results show when the single measurement time needs 1 s and the resolution is 10 μm at room temperature, the corresponding trap depth is larger than 0.68 eV. Meanwhile, under high temperature or with voltage applied, the depth can further increase. The combined measurement results of the PEA and Q(t) methods indicate that the former focuses on charge distribution in deep traps, which allows to calculate the distorted electric field. The latter can measure the changing process of the total charge involved in all traps, which is applicable to analysing the leakage current. Therefore, the evaluation of HVDC insulation properties based on the joint application of the two methods is more reliable.
Źródło:
Metrology and Measurement Systems; 2021, 28, 3; 565-580
0860-8229
Pojawia się w:
Metrology and Measurement Systems
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Testing of a oil spill mathematical model contained in PISCES II simulator
Autorzy:
Łazuga, K.
Powiązania:
https://bibliotekanauki.pl/articles/360616.pdf
Data publikacji:
2012
Wydawca:
Akademia Morska w Szczecinie. Wydawnictwo AMSz
Tematy:
SAR
wind
current
oil
Opis:
PISCES II is a simulator designed to conduct research and training related to the rescue operation in the event of an oil spill on any of the world region. The program includes a built-in mathematical model, enables the oil spill of crude oil to observe the interaction in user-specified external conditions. This paper presents the results of the analysis of mathematical model simulation Pisces II, the behavior of the oil slick in selected hydrometeorological conditions.
Źródło:
Zeszyty Naukowe Akademii Morskiej w Szczecinie; 2012, 32 (104) z. 2; 105-109
1733-8670
2392-0378
Pojawia się w:
Zeszyty Naukowe Akademii Morskiej w Szczecinie
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Generalized space vector control for current source inverters and rectifiers
Autorzy:
Anitha Roseline, J.
Senthil Kumaran, M.
Rajini, V.
Powiązania:
https://bibliotekanauki.pl/articles/140525.pdf
Data publikacji:
2016
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
current source rectifiers (CSR)
current source inverters (CSI)
current source multilevel inverter (CSMLI)
space vector pulse width modulation (SVPWM)
Opis:
Current source inverters (CSI) is one of the widely used converter topology in medium voltage drive applications due to its simplicity, motor friendly waveforms and reliable short circuit protection. The current source inverters are usually fed by controlled current source rectifiers (CSR) with a large inductor to provide a constant supply current. A generalized control applicable for both CSI and CSR and their extension namely current source multilevel inverters (CSMLI) are dealt in this paper. As space vector pulse width modulation (SVPWM) features the advantages of flexible control, faster dynamic response, better DC utilization and easy digital implementation it is considered for this work. This paper generalizes SVPWM that could be applied for CSI, CSR and CSMLI. The intense computation involved in framing a generalized space vector control are discussed in detail. The algorithm includes determination of band, region, subregions and vectors. The algorithm is validated by simulation using MATLAB /SIMULINK for CSR 5, 7, 13 level CSMLI and for CSR fed CSI.
Źródło:
Archives of Electrical Engineering; 2016, 65, 2; 235-248
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wpływ zakłóceń od zewnętrznych pól magnetycznych na przetworniki prądu o jednorodnym obwodzie magnetycznym
Influence of disturbance from external magnetic fields on current sensors with homogeneous magnetic circuit
Autorzy:
Dusza, D.
Powiązania:
https://bibliotekanauki.pl/articles/156088.pdf
Data publikacji:
2011
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
prąd
przetwarzanie
przetwornik indukcyjny
cewka Rogowskiego
current
processing
current sensor
Rogowski coil
Opis:
W artykule przedstawiono przetwornik indukcyjny w postaci równomiernie uzwojonego niemagnetycznego rdzenia obejmującego przepływ przetwarzanego prądu, jego właściwości, wyniki badań wpływu zewnętrznych pól magnetycznych na dokładność przetwarzania oraz oryginalny sposób wyznaczenia współczynnika przetwarzania. Wyniki badań wykonanego przetwornika zostały odniesione do wyników uzyskanych z cewki Rogowskiego w wykonaniu fabrycznym. Badania wpływu zakłóceń od zewnętrznych pól magnetycznych pełnią kluczową rolę w ocenie jakości wykonanego przetwornika, a w szczególności możliwa jest ocena niejednorodności nawinięcia uzwojenia wtórnego przetwornika na całym jego obwodzie.
The paper deals with an inductive sensor in the form of evenly winded nonmagnetic core including processed current flow (Fig. 1), its properties and research results of the influence of external magnetic fields (Fig. 3) on the processing accuracy. Moreover, the original method for determining the processing factor M (relation (11)) and its measurement with using the loop in ?E,?U coordinates for an inductive sensor (Fig. 2a) and for the Rogowski coil (Fig. 2b) are presented. The loop area was determined with use of the estimator described by relation (12). The research results of the constructed sensor (14) were compared with those for the mass produced Rogowski coil (15). The sensor output signal is exactly proportional to the derivative of the current, and the proportionality factor M is constant for any current values. Investigations of the influence of disturbances from external magnetic fields play a key role in the quality assessment of the constructed sensor (measured maximum value is 0.4%, in comparison to 2% of Rogowski coil), in particular the possibility of assessing the sensor secondary winding heterogeneity along the whole circuit.
Źródło:
Pomiary Automatyka Kontrola; 2011, R. 57, nr 12, 12; 1522-1524
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wavelet analysis of on-dimensional traction signals
Autorzy:
Kozłowski, M.
Powiązania:
https://bibliotekanauki.pl/articles/242386.pdf
Data publikacji:
2009
Wydawca:
Instytut Techniczny Wojsk Lotniczych
Tematy:
tram driving system with direct current engines
adhesion failure
engine current
recognition
Opis:
The article presents issues concerning the analysis of one-dimensional traction signals describing energy conversion processes in driving systems of electric traction vehicles. The method of FFT analysis has been compared to the wavelet method. The most crucial tasks have been discussed of wavelet analyses of signals connected with the problems of drive modelling. Fundamental tasks of coefficient analyses such as approximation, compression and denoising have been taken into account, as well as more complex tasks such as filtering band component and feature extraction. An example of analysis of current signal from tram driving system obtained in the conditions of tractive adhesion failure has been presented. A hypothesis has been demonstrated that coefficients obtained in subsequent stages of wavelet decomposition can constitute the basis for indicating electric current feature vector for the phenomenon of adhesion failure. Application has been proposed of simple characteristics of transform coefficients such as energy, number of zero transitions and power. A feature vector of coefficients has been chosen. A method of feature classification has been proposed in order to implement it in adhesion failure recognition. The results of verification of wavelet analysis application in adhesion failure recognition have been presented. As tance has been taken as to the results of the diagnosis taking into consideration currently used anti-slip systems of traction vehicles.
Źródło:
Journal of KONES; 2009, 16, 2; 231-237
1231-4005
2354-0133
Pojawia się w:
Journal of KONES
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Badania prądowe tramwajowych odbieraków prądu
Current tests of trams pantgraphs
Autorzy:
Sitarz, M.
Hełka, A.
Mańka, A.
Lipiński, F.
Powiązania:
https://bibliotekanauki.pl/articles/252816.pdf
Data publikacji:
2013
Wydawca:
Instytut Naukowo-Wydawniczy TTS
Tematy:
badanie prądowe
odbierak prądu
odbieraj tramwajowy
current research
current collector
get tram
Opis:
Odpowiednie wymogi i metodyka badań dotycząca tramwajowych odbieraków prądu zawarte są w normie PN-K-92004:1997 [1]. Jednakże jeśli chodzi o badania związane z obciążalnością prądową, to zarówno wytyczne dotyczące metodyki badań, jak i kryteriów oceny są bardzo skąpe. Brakuje wielu informacji o warunkach przeprowadzania badań, a kryteria oceny odwołują się do normy PN-69/E-0612 [2], która jest już wycofana. Ponadto norma PN-K-92004:1997 [1] nie przewiduje możliwości przeprowadzenia badań obciążalności prądowej pantografów dla parametrów prądu większych niż standardowe.
Źródło:
TTS Technika Transportu Szynowego; 2013, 12; 47-48
1232-3829
2543-5728
Pojawia się w:
TTS Technika Transportu Szynowego
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Variable-speed drive with series - excited motors in dynamic braking mode
Autorzy:
Kenessova, Perizat
Kaverin, Vladimir
Tatkeyeva, Galiya
Powiązania:
https://bibliotekanauki.pl/articles/24200808.pdf
Data publikacji:
2023
Wydawca:
Polska Akademia Nauk. Polskie Naukowo-Techniczne Towarzystwo Eksploatacyjne PAN
Tematy:
electric motor
power section
direct current drive
alternating current drive
circuit design
Opis:
Variable-speed DC drives with series-excited motors are widely used in the mining industry, transport and lifting equipment. The purpose of the study is to determine the dynamic characteristics of a variable direct current (DC) drive with a series-excited motor in the dynamic braking mode. In the article, there have been developed schematic diagrams of the power section that ensure stable braking of a variable-speed electric drive with a series-excited motor. The requirements for the braking mode have been developed. The studies have been carried out for a saturated and unsaturated magnetic circuit of an electric motor. The scientific novelty of the work consists in determining the zone of stable operation of the dynamic braking mode. As a result, there has been proposed technical implementation of the power section of a variable-speed electric drive with a series-excited motor that ensures stable braking. A special place in the study is the development of two models of an electric motor with subsequent excitation taking into account the saturation of the magnetic circuit - mathematical and simulation. Thus, the article has not only theoretical but also visual and practical significance in the context of already conducted studies on the subject. Options for the technical implementation of the braking regime were also considered in the course of the sequential implementation of the planned stages of the study.
Źródło:
Eksploatacja i Niezawodność; 2023, 25, 1; art. no. 9
1507-2711
Pojawia się w:
Eksploatacja i Niezawodność
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Performance of current-voltage converter with amorphous core
Działanie przetwornika prądowo-napięciowego z rdzeniem amorficznym
Autorzy:
Habrych, M.
Powiązania:
https://bibliotekanauki.pl/articles/1361018.pdf
Data publikacji:
2016
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie. Wydawnictwo AGH
Tematy:
amorphous material
current measurement
current-voltage converter
deformed current waveform
materiały amorficzne
pomiary prądu
przetwornik prądowo-napięciowy
zniekształcone przebiegi prądu
Opis:
The paper presents and discusses investigated results of metrological characteristics of a new generation of current-voltage converters manufactured with the use of the innovative technology of soft magnetic components. Current and angle errors of the converters together with current and frequency ranges of their work have been identified.
W artykule przedstawiono i omówiono wyniki badań charakterystyk metrologicznych nowej generacji przetworników prądowo-napięciowych wyprodukowanych przy użyciu innowacyjnej technologii miękkich części magnetycznych. Określono błędy prądowe i kątowe przetworników wraz z zakresami prądowymi i częstotliwościowymi ich pracy.
Źródło:
Mining – Informatics, Automation and Electrical Engineering; 2016, 54, 1; 15-20
2450-7326
2449-6421
Pojawia się w:
Mining – Informatics, Automation and Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
ADCP-referenced geostrophic velocity and transport in the West Spitsbergen current
Autorzy:
Osinski, R.
Wieczorek, P.
Beszczynska-Moller, A.
Goszczko, I.
Powiązania:
https://bibliotekanauki.pl/articles/48340.pdf
Data publikacji:
2003
Wydawca:
Polska Akademia Nauk. Instytut Oceanologii PAN
Tematy:
Arctic circulation
Atlantic water
acoustic Doppler current profiler
geostrophic flow
West Spitsbergen current
Źródło:
Oceanologia; 2003, 45, 3
0078-3234
Pojawia się w:
Oceanologia
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Coherent current oscillations and water exchange in the straits of the Gulf of Riga
Autorzy:
Talpsepp, L.
Powiązania:
https://bibliotekanauki.pl/articles/49149.pdf
Data publikacji:
2005
Wydawca:
Polska Akademia Nauk. Instytut Oceanologii PAN
Tematy:
current
water exchange
coherent current
Riga Gulf
Gulf of Riga Project
Baltic Sea
Opis:
The water exchange processes through the Irbe and Virtsu (Suur) Straits were investigated in 1993–1997 within the framework of a five-year study programme – the Gulf of Riga Project. Simultaneous current measurement data from autonomous mooring stations in both straits were available for the analysis in two periods. In addition to the dominant signals – inertial oscillations in the Virtsu Strait and diurnal oscillations in the Irbe Strait – low-frequency oscillations were found in both straits. During the experiment in July–August 1994, 12–14-day oscillations were observed in both straits: the maximum phase lag in the Virtsu Strait was 1 day. The other important low-frequency periodic component in both straits was 88 hours. In this case, the phase lag in the Virtsu Strait was about 20 hours. In the 1995 experiment in the Irbe Strait, 42-hour oscillations were observed with a phase lag of 10–12 hours. The amplitude was about 30 cm s−1 in both straits. As in Lilover et al. (1998), where the flow regime in the Irbe Strait was observed, we can interpret these oscillations as being wind-generated. The present work shows the existence of these disturbances also in the Virtsu Strait. The 88-hour oscillations observed in July–August 1994 can be interpreted as the first mode of the basin’s eigenoscillations according to the concept of Otsmann et al. (1997) of a basin with two separate outlets. The lowest frequency oscillation with the period of 12–14 days seemed to propagate to the Gulf of Riga from the Baltic Proper, but the generating force could not be established because there was no noticeable variability between depressions and anticyclones during that period. Based on the current measurements, two types of water exchange through the Irbe strait were established: the outflow over the whole cross-section of the strait, and a bidirectional flow with an inflow near the southern shore and increasing inflow in the near-bottom layers and an outflow in the northern part of the strait.
Źródło:
Oceanologia; 2005, 47, 2
0078-3234
Pojawia się w:
Oceanologia
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Estimation of the inductive current transformer derating for operation with distorted currents
Autorzy:
Kaczmarek, M.
Powiązania:
https://bibliotekanauki.pl/articles/201060.pdf
Data publikacji:
2014
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
current transformer
distorted current
derating conditions
composite errors
transformer correction factor
accuracy class
Opis:
The aim of the paper is to present a new method for estimation of the CT (Current Transformer) rated primary current and / or load of the secondary winding derating levels for transformation of distorted current in relation to the rated values fixed for transformation of sinusoidal current. This ensures the values of the CT composite errors/transformer correction factors as resulting from its IEC 60044-1/IEEE C57.13 accuracy class in condition of distorted currents transformation.
Źródło:
Bulletin of the Polish Academy of Sciences. Technical Sciences; 2014, 62, 2; 363-366
0239-7528
Pojawia się w:
Bulletin of the Polish Academy of Sciences. Technical Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Probabilistic assessment of the short-circuit duration on the 220 kV transmission line basing on simulation analysis
Autorzy:
Frąckowiak, R.
Piechocki, P.
Powiązania:
https://bibliotekanauki.pl/articles/97379.pdf
Data publikacji:
2012
Wydawca:
Politechnika Poznańska. Wydawnictwo Politechniki Poznańskiej
Tematy:
transmission lines
current
simulation analysis
Opis:
In the paper, the problem of defining the short circuit duration time for the short-circuit effect calculations, especially thermal and electromagnetic ones, has been discussed. In author’s opinion, the results of probabilistic research could be helpful when resolving the problem. Therefore, a tailored simulation model based on the analysis of the protections and circuit breakers operation during the transmission lines fault clearance has been developed. Due to the results of simulation study, the found values of the fault duration time could be related to the expected risk of their exceeding depending on both the protection system configuration and the type of the circuit breakers applied.
Źródło:
Computer Applications in Electrical Engineering; 2012, 10; 275-282
1508-4248
Pojawia się w:
Computer Applications in Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Illustration of the elliptical field in the screened flat 3-phase high current busduct
Autorzy:
Kusiak, D.
Piątek, Z.
Szczegielniak, T.
Powiązania:
https://bibliotekanauki.pl/articles/97732.pdf
Data publikacji:
2012
Wydawca:
Politechnika Poznańska. Wydawnictwo Politechniki Poznańskiej
Tematy:
high-current busduct
magnetic fields
Opis:
The paper demonstrates the elliptical magnetic field in the flat 3-phase high current screened busduct in the context of the both the external and internal proximity effect. The modules and the amplitudes of the complex components of the magnetic field strength in the high-current busducts of this type are the functions of the two variables: r and Ѳ of the cylindrical coordinate system which subsequently provokes to the conclusion that the harmonic magnetic field in shielded high-current busducts is a rotating elliptical field. For the characterisation of complex vector values for this field, it is suggested that the length of the longer semi axis of an ellipse as showed at the end of the vector within one period should be used. The article presents the elliptic magnetic field in the screen, and the internal and external area of the screen of the flat 3-phase high current busduct.
Źródło:
Computer Applications in Electrical Engineering; 2012, 10; 80-97
1508-4248
Pojawia się w:
Computer Applications in Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Influence of ship motion on waterway. Backward current velocity
Autorzy:
Kulczyk, J.
Werszko, R.
Powiązania:
https://bibliotekanauki.pl/articles/260512.pdf
Data publikacji:
2006
Wydawca:
Politechnika Gdańska. Wydział Inżynierii Mechanicznej i Okrętownictwa
Tematy:
waterway
bow form
backward current
Opis:
In this work was presented an influence of bow form of inland waterways ship and waterway limitations on values of backward current velocity. The analysis was performed on the basis of results of calculations with the use of numerical modeling the flow around ship hull. The applied HPSDK computation system (a computer software developed by these authors) is based on using surface distribution of vorticity to analyze the velocity field and pressure distribution around ship hull. It was proved that the generated backward current velocity exceeded its permissible non-scouring values.
Źródło:
Polish Maritime Research; 2006, S 2; 23-28
1233-2585
Pojawia się w:
Polish Maritime Research
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Performance comparison of varistor models under high current derivative impulses
Autorzy:
Edirisinghe, M.
Montańo, R.
Cooray, V.
Roman, F.
Powiązania:
https://bibliotekanauki.pl/articles/412116.pdf
Data publikacji:
2013
Wydawca:
Przedsiębiorstwo Wydawnictw Naukowych Darwin / Scientific Publishing House DARWIN
Tematy:
varistors
fast front current impulses
Opis:
Surge protective devices (SPD) testing procedures are mainly performed with standard current pulse types. However, none of these standard current waveforms reproduce the very fast rise time and the large peak current derivatives observed in subsequent return strokes. In the literature there are several mathematical models to represent metal oxide varistor that have been developed based on standard impulse conditions. These models are being used routinely in the analysis of the various electronic circuits under transient conditions. In this paper, a study was conducted to have a performance comparison between the two varistor models, simplified varistor model and Durbak's model, available in the literature under high current derivative impulses. The experiments and simulations were performed on disk type varistors with different diameter sizes, i.e., 20mm, 10mm, and 05mm with nominal operating voltage of 230 V. The Roman Generator developed at Uppsala University was used as the high current derivative impulse generator which can produce a peak current up to 1500 A with 10 ns rise time and its rate-of-rise is in the order of 1011 A/s. The results showed that for standard 8/20 ěs lightning impulses, simulation results of these models had a good agreement with the experimental data. However, these two models need to be improving in order to improve their performance under high current derivative impulses into the sub-microsecond range.
Źródło:
International Letters of Chemistry, Physics and Astronomy; 2013, 6; 40-53
2299-3843
Pojawia się w:
International Letters of Chemistry, Physics and Astronomy
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
New Control Algorithms for Three-Phase Four-Wire Unified Power Quality Conditioner - a simulation study
Autorzy:
Pal, Y.
Swarup, A.
Singh, B.
Powiązania:
https://bibliotekanauki.pl/articles/262781.pdf
Data publikacji:
2013
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie
Tematy:
UPQC
power quality improvement
source neutral current
mitigation
load balancing
voltage harmonics
current harmonics
Opis:
In this paper, some new control algorithms are proposed for a three-phase four-wire Unified Power Quality Conditioner. These control algorithms are based on the combination of Unit Vector Template Generation (UVTG) with Power Balance Theory (PBT), single phase d-q theory, Synchronous Current Detection (CSD) technique, and I CosΦ theory. The performance of each control algorithm of UPQC is evaluated in terms of power factor correction, load balancing and source neutral current mitigation, and voltage and current harmonic mitigation. The performance of proposed control algorithms are compared with synchronous reference frame (SRF) based control algorithm. In each proposed control scheme of the three-phase four-wire UPQC, the current/voltage control is applied over the fundamental supply currents/ load voltages instead of fast changing APFs currents/ voltages, thereby reducing the effects of computational delay. Moreover, the load neutral or shunt APF neutral currents are not sensed hence the required current sensors are reduced. MATLAB/ Simulink based simulations are obtained, which support the functionality of the UPQC.
Źródło:
Electrical Power Quality and Utilisation. Journal; 2013, 16, 1; 1-10
1896-4672
Pojawia się w:
Electrical Power Quality and Utilisation. Journal
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wpływ czterokrokowego układu komutacji prądu na odkształcenie prądu wyjściowego przekształtnika matrycowego
The effect of four-step current commutation on the matrix converter output current
Autorzy:
Łowiec, E.
Milak, A.
Powiązania:
https://bibliotekanauki.pl/articles/159727.pdf
Data publikacji:
2013
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Elektrotechniki
Tematy:
przekształtnik matrycowy
komutacja czterokrokowa prądu
odkształcenie prądu
matrix converter
four step current commutation
current distortion
Opis:
W artykule przedstawiono realizację czterokrokowej komutacji prądu w przekształtniku matrycowym za pomocą układu CPLD firmy ALTERA. Wykonano badania empiryczne zależności zniekształcenia prądu wyjściowego przekształtnika matrycowego od długości kroku komutacji i wzmocnienia napięciowego. Badania wykonano w oparciu o laboratoryjny model przekształtnika typu podwójnego.
The paper presents the implementation of the fourstep current commutation in matrix converter using the programmable ALTERA CPLD device. The dependence of the output current distortion on modulation parameters i.e. step length and voltage gain has been investigated empirically. The tests were done using a laboratory model of a double converter.
Źródło:
Prace Instytutu Elektrotechniki; 2013, 262; 67-80
0032-6216
Pojawia się w:
Prace Instytutu Elektrotechniki
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Badanie działania wyłączników różnicowoprądowych przy częstotliwościach prądu różnicowego mniejszych niż 50 Hz
Testing of residual current devices under residual current at frequencies lower than 50 Hz
Autorzy:
Czapp, S.
Kałka, Ł.
Powiązania:
https://bibliotekanauki.pl/articles/266871.pdf
Data publikacji:
2016
Wydawca:
Politechnika Gdańska. Wydział Elektrotechniki i Automatyki
Tematy:
częstotliwość prądu
ochrona przeciwporażeniowa
wyłącznik różnicowoprądowy
current frequency
protection against electric shock
residual current devices
Opis:
Zdecydowana większość powszechnie stosowanych wyłączników różnicowoprądowych jest przystosowana do wykrywania prądu różnicowego o częstotliwości 50/60 Hz. Układ detekcji prądu różnicowego i wyzwalania wyłącznika jest wrażliwy na zmianę częstotliwości i bywa tak, że wyłącznik w ogóle nie reaguje na prądy różnicowe o częstotliwości znacznie odbiegającej od 50/60 Hz. W artykule przedstawiono wyniki badań działania wyłączników różnicowoprądowych przy częstotliwościach prądu różnicowego mniejszych niż 50 Hz. Badania wykazały, że próg zadziania wyłączników różnicowoprądowych może silnie wzrastać wraz ze zmniejszaniem się częstotliwości tego prądu.
The majority of commonly used residual current devices is designed for detection the residual current with frequency of 50/60 Hz. Detecting and tripping system of residual current devices is sensitive to the change in frequency and it happens that they do not respond to the residual current when the frequency is significantly different from 50/60 Hz. The paper presents the results of a study of tripping characteristics of residual current devices at frequencies lower than 50 Hz. The study has shown that the tripping threshold of residual current devices may strongly increase with decreasing frequency of residual current.
Źródło:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej; 2016, 50; 15-18
1425-5766
2353-1290
Pojawia się w:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Przetwornik prądowo-napięciowy ze zmodyfikowanym rdzeniem amorficznym do pomiarów prądowych przebiegów odkształconych
Current-to-voltage converter with an amorphous core modified to measure deformed runs of current
Autorzy:
Habrych, M.
Lubryka, J.
Macierzyński, D.
Kozłowski, A.
Morawiec, M.
Powiązania:
https://bibliotekanauki.pl/articles/187748.pdf
Data publikacji:
2012
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Technik Innowacyjnych EMAG
Tematy:
przetworniki prądowo-napięciowe
pomiary przebiegów odkształconych
current-to-voltage converters
measuring deformed runs of current
Opis:
W artykule zaprezentowano i omówiono wyniki badań właściwości metrologicznych przetwornika prądowo-napięciowego z zastosowanym zmodyfikowanym rdzeniem amorficznym przydatnym do pomiarów prądowych, zwłaszcza przebiegów odkształconych w układach napędowych. Wyznaczono wartości błędów prądowych i kątowych przetwornika w szerokim zakresie zmian wartości skutecznych i częstotliwości mierzonych prądów.
The article presents and discusses the results of testing the metrological properties of a current-to-voltage converter with a modified amorphous core adapted to measure the current, particularly deformed runs of current in driving systems. The values of the current- and angle errors were determined in a wide range of the changing values of the effective values and frequencies of the measured currents.
Źródło:
Mechanizacja i Automatyzacja Górnictwa; 2012, R. 50, nr 10, 10; 24-29
0208-7448
Pojawia się w:
Mechanizacja i Automatyzacja Górnictwa
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Determinanty wyboru banku przez młodych klientów
Factors influencing banks choice by young Polish clients
Autorzy:
Sołtysiak, Mirosław
Powiązania:
https://bibliotekanauki.pl/articles/446955.pdf
Data publikacji:
2015
Wydawca:
Mazowiecka Uczelnia Publiczna w Płocku
Tematy:
bank
banking (current) account
young clients
Opis:
Using banking services is an everyday and popular phenomenon for Polish educated youth aged 20 or so. The fully understand that the lack of their own bank account may contribute to their financial exclusion and therefore influence their quality of life. For this reason these bank clients are characterised by high banking competences. Representatives of the group in question tend to focus on the convenience and cost minimisation while choosing their bank. Considering the bank's choice they mainly pay attention to its distribution chain, in particular the numer of cash dispensers, as well as the location of its outlets. Next, the customers are affected by the recommendations of relatives or close people around them. Majority of the youth already own their bank account with online services' access and the cost of such account does not normally exceed 5 PLN. Finally, the bank's choice made by the young people is more dependent on the opinion of their relatives or friends rather than the bank's advert or the bank attendants' recommendations.
Źródło:
Zeszyty Naukowe PWSZ w Płocku. Nauki Ekonomiczne; 2015, 2(22); 197-203
1644-888X
Pojawia się w:
Zeszyty Naukowe PWSZ w Płocku. Nauki Ekonomiczne
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Metodyka wyznaczania gęstości krytycznej prądu materiałów nadprzewodnikowych
Methods of determination of critical current density of superconducting materials
Autorzy:
Rymaszewski, J.
Lebioda, M.
Powiązania:
https://bibliotekanauki.pl/articles/157769.pdf
Data publikacji:
2010
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
nadprzewodnictwo
prąd krytyczny
critical current
superconductivity
Opis:
W artykule zaprezentowano dwie podstawowe metody wyznaczania gęstości krytycznej prądu materiałów nadprzewodnikowych: metodę transportową i metodę magnetyczną. Przedstawiono fizyczne przyczyny powstawania rezystancji w nadprzewodniku, inicjowane przez przepływ prądu, tj. deparowanie par Coopera, ruch wirów Abrikosowa, słabe złącza międzyziarnowe, generacja ciepła w obszarach normalnych. Na podstawie analizy zjawisk towarzyszących przepływowi prądu w nadprzewodniku oraz wyników badań eksperymentalnych sformułowano wniosek o niejednoznaczności wyników otrzymywanych metodą kontaktową i metodą magnetyczną. Wynika stąd konieczność realizacji pomiarów w układzie jak najbardziej odtwarzającym warunki rzeczywistej pracy materiału nadprzewodnikowego.
The two basic methods of determination of superconductor critical current density have been presented in this article. The transport method requires samples with the current and voltage electrodes. This method is realized by forcing of the current in the superconductor and analyzing the voltage response on the sample. The magnetic method does not requires electrodes and the critical current density is estimated from the magnetic response of the superconductor. The determined values of the critical current density, obtained from the both methods, are often different. It arises from the considerable complexity of the phenomena in superconductors, in which the current flows. The physical reasons of the appearance of the superconductor resistance, initiated by the current flow, have been shown in this paper. The most important reasons are: the Cooper pairs depairing, the motion of the Abrikosov vortices, the presence of Josephson weak links in the structure of many superconductors and the heat generation in the normal areas. The analysis of the presented phenomena and the results of the experiments allow to formulate the following conclusion: the critical current density obtained from the various methods for the same sample can be different. Therefore the measurement conditions should be similar to the operating conditions of the superconducting materials in their applications.
Źródło:
Pomiary Automatyka Kontrola; 2010, R. 56, nr 9, 9; 1047-1050
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Eddy Current Tomography for Nondestructive Testing
Autorzy:
Salach, J.
Powiązania:
https://bibliotekanauki.pl/articles/384233.pdf
Data publikacji:
2014
Wydawca:
Sieć Badawcza Łukasiewicz - Przemysłowy Instytut Automatyki i Pomiarów
Tematy:
eddy current tomography
NDT
signal processing
Opis:
The paper presents an eddy current tomography setup with high spatial resolution and high accuracy of measurements of signal on detection coil. In proposed solution both amplitude as well as phase shift are measured, which gives the possibility of calculation of spatial distribution of both permeability and resistivity of tested element. As a result, presented setup creates possibility of effective detection of discontinuities in cylindrical elements, which opens new possibilities for industrial applications of eddy current tomography.
Źródło:
Journal of Automation Mobile Robotics and Intelligent Systems; 2014, 8, 4; 11-14
1897-8649
2080-2145
Pojawia się w:
Journal of Automation Mobile Robotics and Intelligent Systems
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Łagodzenie oraz skrócenie czasu procesu synchronizacji silników synchronicznych
Soften and reduction duration of synchronization process in synchronous motors
Autorzy:
Zalas, P.
Zawilak, J.
Powiązania:
https://bibliotekanauki.pl/articles/320260.pdf
Data publikacji:
2006
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie. Wydawnictwo AGH
Tematy:
synchronous motor
synchronization
excitation current control
Opis:
Przedstawiono wyniki obliczeń procesu synchronizacji dla wybranego modelu dwubiegowego silnika synchronicznego typu GAe 1716/20t. Wykazano możliwości łagodzenia przebiegu procesu synchronizacji oraz skrócenia jego czasu przez sterowanie wartością prądu wzbudzenia. Zbadano wpływ przyjętych układów regulacji prądu magneśnicy na przebiegi tego procesu. Wyniki obliczeń zamieszczono w postaci wykresów czasowych.
The work presents calculation results of synchronization process of a two-speed, silent-pole, high power synchronous motor. The calculations were based on circuit model for motor type GAe 1716/20t with switchable configuration connection of armature winding and field magnet. The influence of control of excitation current value on stator currents, electromagnetic torque and shaft velocity during synchronization process has been investigated. The results of calculations were presented as time curves of state variables.
Źródło:
Elektrotechnika i Elektronika; 2006, 25, 2; 216-220
1640-7202
Pojawia się w:
Elektrotechnika i Elektronika
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Quasi-homogenous model of electrochemical machining of turbine engine parts
Autorzy:
Kozak, Jerzy
Powiązania:
https://bibliotekanauki.pl/articles/244291.pdf
Data publikacji:
2019
Wydawca:
Instytut Techniczny Wojsk Lotniczych
Tematy:
electrochemical shaping
modelling
simulation
pulse current
Opis:
In order to increase the efficiency of jet engines hard to machine nickel-based and titanium-based alloys are in common use for aero engine components such as blades and blade integrated disks (BLISK). Electrochemical Machining (ECM) provides an economical and effective method for machining high strength and heat-resistant materials into complex shapes with high material removal rate without tool wear and without inducing residual stress. This article presents the physical and mathematical models of electrochemical shaping used in the manufacture of turbine engine parts. The modelling is based on the assumption that the multi-phase mixture filling the gap is treated as two-phase quasi-homogenous medium. The model describes the workpiece shape evolution in time, distribution the local gap size, flow parameters such as the static pressure and the velocity, temperature and void fraction as result of gas generation. The major features of the numerical computer program are briefly described with a selected example of machining a typical turbine blade. The results of computer simulation of effects of setting parameters ECM on accuracy-machined profile are discussed. The improvement of accuracy has been reached by using described sequence of ECM and Pulse ECM processes.
Źródło:
Journal of KONES; 2019, 26, 3; 91-104
1231-4005
2354-0133
Pojawia się w:
Journal of KONES
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies