Tytuł:
Utilization of Process Wastewater Heat
Utylizacja ciepła ścieków poprodukcyjnych
Autorzy:
Szkarowski, Aleksander
Jaworski, Łukasz
Mamedov, Shirali
Powiązania:
https://bibliotekanauki.pl/articles/1811632.pdf
Data publikacji:
2020
Wydawca:
Politechnika Koszalińska. Wydawnictwo Uczelniane
Tematy:
process wastewaters
heat recovery
shell and tube heat exchanger
cross-flow heat exchanger
ścieki produkcyjne
odzysk ciepła
wymiennik płaszczowo-rurowy
wymiennik krzyżowy
Opis:
This papers presents the results of computation of two heat exchangers used for heat utilization of industrial wastewater generated in a refined fiberboard production plant. The basic task was to cool wastewater to a temperature of approximately 40ºC enabling efficient centrifugation of suspended matter at the stage of wastewater pretreatment. A shell-and-tube heat exchanger with the power of 473 kW for water heating was developed for heating the production hall. A cross-flow exchanger was also developed for heating ventilation air in the boiler room building, power of which is 1703 kW. Thermal and hydraulic computation was performed, the required heat exchange surface was selected, the main structural characteristics of both exchangers were determined.
W niniejszym artykule przedstawiono wyniki obliczeń dwóch wymienników ciepła typu służących do utylizacji ciepła ścieków przemysłowych powstających w zakładzie do produkcji uszlachetnionych płyt pilśniowych. Zadaniem podstawowym było schładzanie ścieków do temperatury ok. 40ºC umożliwiającej sprawne odwirowanie zawieszonych substancji na etapie wstępnego podczyszczania ścieków. Opracowano wymiennik płaszczowo-rurowy podgrzewający wodę na cele ogrzewania hali produkcyjnej o mocy 473 kW. Opracowano również wymiennik krzyżowy na cele podgrzania powietrza wentylacyjnego w budynku kotłowni, którego moc wynosi 1703 kW. Wykonano obliczenia cieplne i hydrauliczne, dobrano wymaganą powierzchnię wymiany ciepła, określono główne charakterystyki konstrukcyjne obu wymienników.
Źródło:
Rocznik Ochrona Środowiska; 2020, Tom 22, cz. 2; 1074-1083
1506-218X
Pojawia się w:
Rocznik Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Heat transfer in compact cross-flow mini heat exchanger
Autorzy:
Prończuk, Mateusz
Pabiś, Aleksander
Powiązania:
https://bibliotekanauki.pl/articles/27315660.pdf
Data publikacji:
2023
Wydawca:
Zachodniopomorski Uniwersytet Technologiczny w Szczecinie. Wydawnictwo Uczelniane ZUT w Szczecinie
Tematy:
heat transfer
cross-flow
mini heat exchanger
optimization based method
Opis:
This paper presents the results of an analysis of heat transfer in a cross-flow mini heat exchanger (CFMHE). The purpose of the paper was to analyze the results of the experimental measurements presented in the previous work in order to determine dimensionless correlations that allow for the calculation of heat transfer coefficients for the CFMHE. Analyzed CFMHE consisted of a brass cylindrical core, in which 2 mm circular holes were drilled. A method based on an optimization procedure was used to determine the correlations describing the heat transfer coefficients, allowing the correlations to be determined without the need of measuring the mini channel wall temperature. Overall heat transfer coefficients calculated using the proposed correlations typically did not deviate by more than ±10% from the corresponding experimental results, which was a significant improvement in the quality of the fit compared to the results presented in previous work.
Źródło:
Polish Journal of Chemical Technology; 2023, 25, 3; 79--88
1509-8117
1899-4741
Pojawia się w:
Polish Journal of Chemical Technology
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Temperature efficiency of heat exchangers in air handling units
Autorzy:
Michalak, Piotr
Grygierczyk, Stanisław
Powiązania:
https://bibliotekanauki.pl/articles/95368.pdf
Data publikacji:
2019
Wydawca:
Politechnika Koszalińska. Wydawnictwo Uczelniane
Tematy:
ventilation
heat recovery
rotary heat exchanger
cross-flow heat exchanger
temperature efficiency
PN-EN 308
wentylacja
odzysk ciepła
obrotowy wymiennik ciepła
krzyżowy wymiennik ciepła
sprawność temperaturowa
Opis:
In order to reduce ventilation heat loss and improve energy efficiency of low-energy buildings air-handling units (AHUs) with heat recovery are used. The article presents results of surveys performed in a passive building located in Katowice concerning the temperature efficiency of heat and cold recovery of two selected AHUs, with different heat exchangers. For this purpose the measurement data from the Building Management System (BMS) for the period 1.08.2015-31.07.2016 were used. The first unit was equipped with a rotary heat exchanger. Its average annual temperature efficiency of heat recovery was 47.2% annually. The efficiency of cold recovery amounted 52.9% on average for the warm half year. The second unit had a cross-flow exchanger. The average annual temperature efficiency of heat recovery in this device was 80.1%. The efficiency of cold recovery amounted 57.2% on average for the warm half year. Additional remarks concerning the temperature measurement in analysed units were also given.
Źródło:
Journal of Mechanical and Energy Engineering; 2019, 3, 3; 267-272
2544-0780
2544-1671
Pojawia się w:
Journal of Mechanical and Energy Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Prediction of a cross-flow heat exchanger performance in media flow maldistribution conditions
Prognozowanie efektywności pracy krzyżowoprądowego wymiennika ciepła w warunkach niejednorodnego przepływu czynników
Autorzy:
Bury, T.
Składzień, J.
Powiązania:
https://bibliotekanauki.pl/articles/172859.pdf
Data publikacji:
2011
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
krzyżowoprądowy wymiennik ciepła
analiza termodynamiczna
HEWES
cross-flow heat exchanger
thermodynamical analysis
Opis:
The paper deals with numerical thermodynamic analyses of cross-flow finned tube heat exchangers of the gas-liquid type. The authors postulate that some improvement of the heat exchanger performance may be achieved by applying a special ribbing structure - fitted to certain media flow conditions. First, the measurements have been carried out in order to determine the air inflow non-uniformity and next an own computer code HEWES has been used for numerical simulations in order to evaluate the impact of the measured non-uniformity on the exchangers' efficiency for the heat exchangers with unified ribbing structure. The numerical simulations have been repeated for heat exchangers with special ribbing structures - determined on the basis of experimental results. Results confirm the hypothesis - some increase in the total heat flow rate may be observed for the considered heat exchanger.
Praca dotyczy termodynamicznej analizy krzyżowoprądowego, ożebrowanego wymiennika ciepła typu gaz-ciecz. Autorzy weryfikowali hipotezę zakładającą możliwość uzyskania poprawy efektywności działania urządzenia w wyniku zastosowania specjalnej, dostosowanej do warunków przepływu czynników, struktury ożebrowania. W pierwszej kolejności wykonane zostały pomiary określające zakres i postać niejednorodnego dopływu powietrza do analizowanego wymiennika ciepła, a następnie wykorzystano własny kod komputerowy HEWES do oceny wpływu tej niejednorodności na wydajność cieplną wymiennika. Obliczenia te dotyczyły wymiennika ciepła z jednorodnym ożebrowaniem. Symulacje numeryczne zostały następnie powtórzone dla przypadku wymiennika ze specjalną strukturą ożebrowania, która została dobrana dla wyznaczonych eksperymentalnie warunków dopływu powietrza. Uzyskane rezultaty potwierdzają postawioną na wstępie hipotezę - widoczny jest pewien wzrost wartości strumienia ciepła przekazywanego w wymienniku.
Źródło:
Archiwum Energetyki; 2011, 41, 3-4; 65-76
0066-684X
Pojawia się w:
Archiwum Energetyki
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-4 z 4

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies