Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "cross flow" wg kryterium: Temat


Tytuł:
Modelling of bubble formation with the aid of CFD
Autorzy:
Biń, A. K.
Machniewski, P. M.
Rudniak, L.
Powiązania:
https://bibliotekanauki.pl/articles/1955714.pdf
Data publikacji:
2004
Wydawca:
Politechnika Gdańska
Tematy:
bubble formation
cross-flow
CFD
VOF
Opis:
Results of a numerical simulation of the bubble formation process obtained with the aid of computational fluid dynamics (CFD) approach are presented. A solution of the momentum balance (Navier-Stokes) equations was coupled with the volume of fluid (VOF) algorithm for tracking the gas-liquid interface in 2D and 3D domains. The simulation results are compared with the experimental data regarding the influence of gas flow rate on the bubble formation regime and volume of the produced bubbles in a low-viscosity system (air-water). As the simulation results are in agreement with the experimental observations, the VOF algorithm is found to be a valuable tool for studying the phenomena of gas-liquid interaction.
Źródło:
TASK Quarterly. Scientific Bulletin of Academic Computer Centre in Gdansk; 2004, 8, 1; 17-26
1428-6394
Pojawia się w:
TASK Quarterly. Scientific Bulletin of Academic Computer Centre in Gdansk
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Modernization of the outflow system of cross-flow turbines
Autorzy:
Kaniecki, M.
Powiązania:
https://bibliotekanauki.pl/articles/1931595.pdf
Data publikacji:
2002
Wydawca:
Politechnika Gdańska
Tematy:
cross-flow turbine
CFD analysis
outflow system
Opis:
The presented article brings general overview of CFD analysis of two cross-flow turbine types (a classical impulse turbine and a reaction turbine). The author focuses his attention mainly on the discussion of differences in flow patterns in the outflow section of these turbines, because this element exerts significant impact on performance properties of the turbine. The article presents a comparison of computations and experimental results of the cross-flow turbine manufactured by IMP PAN. The analysis was performed by means of a computer program FLUENT for a two-dimensional example.
Źródło:
TASK Quarterly. Scientific Bulletin of Academic Computer Centre in Gdansk; 2002, 6, 4; 601-608
1428-6394
Pojawia się w:
TASK Quarterly. Scientific Bulletin of Academic Computer Centre in Gdansk
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Fretting wear analysis of different tube materials used in heat exchanger tube bundle
Autorzy:
Abbas, T.
Khushnood, S.
Nizam, L. A.
Usman, M.
Powiązania:
https://bibliotekanauki.pl/articles/957958.pdf
Data publikacji:
2017
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
fretting wear
flow-induced vibration
flexible tube
cross flow velocity
Opis:
Research on heat exchange has been carried out for more than five decades because of its importance in process industries and power generation plants. Heat exchanger experiencing cross flow are vulnerable to flow-induced vibration. This vibration causes the interaction of tubes with the baffle resulting in a fretting wear of the tubes. The present study focuses on fretting wear analysis of different tube materials. Fretting wear tests were performed on aluminum, copper and stainless steel instrumented central tubes against mild steel baffle. For each tube material the tests were performed for three different test durations i.e. 60 minutes, 120 minutes and 180 minutes at a cross flow velocity of 0.55 m/s. It was observed that vibrational amplitude of the flexible test tube is affected by its weight. A scanning electron microscope was used to analyze and measure the sizes of wear scar. The results indicated that wear loss in case of aluminum tube is the highest while that in case of stainless steel tube is the lowest.
Źródło:
Advances in Science and Technology. Research Journal; 2017, 11, 4; 123-133
2299-8624
Pojawia się w:
Advances in Science and Technology. Research Journal
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Heat transfer in compact cross-flow mini heat exchanger
Autorzy:
Prończuk, Mateusz
Pabiś, Aleksander
Powiązania:
https://bibliotekanauki.pl/articles/27315660.pdf
Data publikacji:
2023
Wydawca:
Zachodniopomorski Uniwersytet Technologiczny w Szczecinie. Wydawnictwo Uczelniane ZUT w Szczecinie
Tematy:
heat transfer
cross-flow
mini heat exchanger
optimization based method
Opis:
This paper presents the results of an analysis of heat transfer in a cross-flow mini heat exchanger (CFMHE). The purpose of the paper was to analyze the results of the experimental measurements presented in the previous work in order to determine dimensionless correlations that allow for the calculation of heat transfer coefficients for the CFMHE. Analyzed CFMHE consisted of a brass cylindrical core, in which 2 mm circular holes were drilled. A method based on an optimization procedure was used to determine the correlations describing the heat transfer coefficients, allowing the correlations to be determined without the need of measuring the mini channel wall temperature. Overall heat transfer coefficients calculated using the proposed correlations typically did not deviate by more than ±10% from the corresponding experimental results, which was a significant improvement in the quality of the fit compared to the results presented in previous work.
Źródło:
Polish Journal of Chemical Technology; 2023, 25, 3; 79--88
1509-8117
1899-4741
Pojawia się w:
Polish Journal of Chemical Technology
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Flow simulations in cross-flow fans using the finite element and finite volume methods
Autorzy:
Sowa, A.
Powiązania:
https://bibliotekanauki.pl/articles/1955710.pdf
Data publikacji:
2004
Wydawca:
Politechnika Gdańska
Tematy:
turbomachinery
cross-flow fan
finite element method
finite volume method
usteady flow analysis
Opis:
Both basic computational fluid dynamics methods: the finite element method (FEM) and the finite volume method (FVM) have been used to simulate flow fields in a cross-flow fan (CFF). A review of previous numerical simulations of flow in CFF's is presented. The theorethical foundations of the applied numerical algorithms and specifications of the computer programs are given. The procedure of computations is described in detail. Computational results are shown in the form of contour and vector velocity and contour pressure plots.
Źródło:
TASK Quarterly. Scientific Bulletin of Academic Computer Centre in Gdansk; 2004, 8, 1; 41-49
1428-6394
Pojawia się w:
TASK Quarterly. Scientific Bulletin of Academic Computer Centre in Gdansk
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Prediction of a cross-flow heat exchanger performance in media flow maldistribution conditions
Prognozowanie efektywności pracy krzyżowoprądowego wymiennika ciepła w warunkach niejednorodnego przepływu czynników
Autorzy:
Bury, T.
Składzień, J.
Powiązania:
https://bibliotekanauki.pl/articles/172859.pdf
Data publikacji:
2011
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
krzyżowoprądowy wymiennik ciepła
analiza termodynamiczna
HEWES
cross-flow heat exchanger
thermodynamical analysis
Opis:
The paper deals with numerical thermodynamic analyses of cross-flow finned tube heat exchangers of the gas-liquid type. The authors postulate that some improvement of the heat exchanger performance may be achieved by applying a special ribbing structure - fitted to certain media flow conditions. First, the measurements have been carried out in order to determine the air inflow non-uniformity and next an own computer code HEWES has been used for numerical simulations in order to evaluate the impact of the measured non-uniformity on the exchangers' efficiency for the heat exchangers with unified ribbing structure. The numerical simulations have been repeated for heat exchangers with special ribbing structures - determined on the basis of experimental results. Results confirm the hypothesis - some increase in the total heat flow rate may be observed for the considered heat exchanger.
Praca dotyczy termodynamicznej analizy krzyżowoprądowego, ożebrowanego wymiennika ciepła typu gaz-ciecz. Autorzy weryfikowali hipotezę zakładającą możliwość uzyskania poprawy efektywności działania urządzenia w wyniku zastosowania specjalnej, dostosowanej do warunków przepływu czynników, struktury ożebrowania. W pierwszej kolejności wykonane zostały pomiary określające zakres i postać niejednorodnego dopływu powietrza do analizowanego wymiennika ciepła, a następnie wykorzystano własny kod komputerowy HEWES do oceny wpływu tej niejednorodności na wydajność cieplną wymiennika. Obliczenia te dotyczyły wymiennika ciepła z jednorodnym ożebrowaniem. Symulacje numeryczne zostały następnie powtórzone dla przypadku wymiennika ze specjalną strukturą ożebrowania, która została dobrana dla wyznaczonych eksperymentalnie warunków dopływu powietrza. Uzyskane rezultaty potwierdzają postawioną na wstępie hipotezę - widoczny jest pewien wzrost wartości strumienia ciepła przekazywanego w wymienniku.
Źródło:
Archiwum Energetyki; 2011, 41, 3-4; 65-76
0066-684X
Pojawia się w:
Archiwum Energetyki
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Experimental and numerical analyses of finned cross flow heat exchangers efficiency under non-uniform gas inlet flow conditions
Autorzy:
Bury, T.
Składzień, J.
Widziewicz, K.
Powiązania:
https://bibliotekanauki.pl/articles/240548.pdf
Data publikacji:
2010
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
analiza eksperymentalna
analiza numeryczna
krzyżowo-płytowy wymiennik ciepła
nierównomierny przepływ płynu
cross-flow heat exchangers
experimental analysis
non-uniform fluid flow
numerical analysis
Opis:
The work deals with experimental and numerical thermodynamic analyses of cross-flow finned tube heat exchangers of the gas-liquid type. The aim of the work is to determine an impact of the gas non-uniform inlet on the heat exchangers performance. The measurements have been carried out on a special testing rig and own numerical code has been used for numerical simulations. Analysis of the experimental and numerical results has shown that the range of the non-uniform air inlet to the considered heat exchangers may be significant and it can significantly affect the heat exchanger efficiency.
Źródło:
Archives of Thermodynamics; 2010, 31, 4; 133-144
1231-0956
2083-6023
Pojawia się w:
Archives of Thermodynamics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Heat transfer enhancement from a heated plate with hemispherical convex dimples by forced convection along with a cross flow jet impingement
Autorzy:
Patro, P.
Garnayak, S.
Powiązania:
https://bibliotekanauki.pl/articles/265024.pdf
Data publikacji:
2020
Wydawca:
Uniwersytet Zielonogórski. Oficyna Wydawnicza
Tematy:
wymiana ciepła
uderzenie strumieniowe
przepływ krzyżowy
heat transfer enhancement
jet impingement
convex dimpled surface
SST k-w model
cross flow
Opis:
In the present study, heat transfer from a small three dimensional rectangular channel due to turbulent jet impinging from a nozzle normal to the main flow at the inlet has been investigated. Hemispherical convex dimples are attached to the bottom plate from where heat transfer calculations are to be performed. Numerical simulations were performed using the finite volume method with […] turbulence model. The duct and nozzle Reynolds number are varied in the range of […], respectively. Different nozzle positions (X/D = 10.57, 12.88, 15.19) along the axial direction of the rectangular duct have been considered. It has been found that higher heat transfer is observed at X/D = 10.57 as compared to the other positions. The heat transfer enhancements with and without cross-flow effects have also been compared. It has been shown that the heat transfer rate with cross-flow is found to be much higher than that without crossflow. Also, the effect of dimples on the heated surface on heat transfer was investigated. The heat transfer is found to be greater in the presence of a dimpled surface than a plane surface.
Źródło:
International Journal of Applied Mechanics and Engineering; 2020, 25, 1; 127-141
1734-4492
2353-9003
Pojawia się w:
International Journal of Applied Mechanics and Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Utilization of Process Wastewater Heat
Utylizacja ciepła ścieków poprodukcyjnych
Autorzy:
Szkarowski, Aleksander
Jaworski, Łukasz
Mamedov, Shirali
Powiązania:
https://bibliotekanauki.pl/articles/1811632.pdf
Data publikacji:
2020
Wydawca:
Politechnika Koszalińska. Wydawnictwo Uczelniane
Tematy:
process wastewaters
heat recovery
shell and tube heat exchanger
cross-flow heat exchanger
ścieki produkcyjne
odzysk ciepła
wymiennik płaszczowo-rurowy
wymiennik krzyżowy
Opis:
This papers presents the results of computation of two heat exchangers used for heat utilization of industrial wastewater generated in a refined fiberboard production plant. The basic task was to cool wastewater to a temperature of approximately 40ºC enabling efficient centrifugation of suspended matter at the stage of wastewater pretreatment. A shell-and-tube heat exchanger with the power of 473 kW for water heating was developed for heating the production hall. A cross-flow exchanger was also developed for heating ventilation air in the boiler room building, power of which is 1703 kW. Thermal and hydraulic computation was performed, the required heat exchange surface was selected, the main structural characteristics of both exchangers were determined.
W niniejszym artykule przedstawiono wyniki obliczeń dwóch wymienników ciepła typu służących do utylizacji ciepła ścieków przemysłowych powstających w zakładzie do produkcji uszlachetnionych płyt pilśniowych. Zadaniem podstawowym było schładzanie ścieków do temperatury ok. 40ºC umożliwiającej sprawne odwirowanie zawieszonych substancji na etapie wstępnego podczyszczania ścieków. Opracowano wymiennik płaszczowo-rurowy podgrzewający wodę na cele ogrzewania hali produkcyjnej o mocy 473 kW. Opracowano również wymiennik krzyżowy na cele podgrzania powietrza wentylacyjnego w budynku kotłowni, którego moc wynosi 1703 kW. Wykonano obliczenia cieplne i hydrauliczne, dobrano wymaganą powierzchnię wymiany ciepła, określono główne charakterystyki konstrukcyjne obu wymienników.
Źródło:
Rocznik Ochrona Środowiska; 2020, Tom 22, cz. 2; 1074-1083
1506-218X
Pojawia się w:
Rocznik Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Transgraniczny przepływ danych osobowych wiernych Kościoła katolickiego z Polski – na przykładzie kazusu
Autorzy:
Chojara-Sobiecka, Małgorzata
Karsten, Kinga
Kroczek, Piotr
Powiązania:
https://bibliotekanauki.pl/articles/554769.pdf
Data publikacji:
2019
Wydawca:
Uniwersytet Papieski Jana Pawła II w Krakowie
Tematy:
cross-border flow of personal data
personal data
the faithful
the Catholic Church
Kościół katolicki
Opis:
The article shows the practical application of data protection regulations in the process of cross-border data transfer by church public legal entities, using a case study as an example. After the presentation of the case study data, the author of the articles makes a few remarks concerning the binding regulations and their application. At the end of the article, the general request is formulated, which orders the controllers to undertake cross-border data transfer with great caution.
Artykuł pokazuje na przykładzie kazusu praktyczne zastosowanie regulacji dotyczących ochrony danych osobowych w procesie transgranicznego przekazywania danych przez kościelne publiczne osoby prawne. Po przedstawieniu danych kazusu autor artykułu czyni kilka uwag dotyczących obowiązujących regulacji i ich zastosowania. Na końcu artykułu zostaje sformułowany ogólny wniosek, który nakazuje administratorom podejmować transgraniczne przekazywanie danych z wielką ostrożnością.
Źródło:
Annales Canonici; 2019, 15, 1
1895-0620
Pojawia się w:
Annales Canonici
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Investigation of the Effects of the Incident Flow Angle on Vibration Behavior in Heat Exchanger Tube Bundle
Autorzy:
Usman, Muhammad
Khushnood, Shahab
Nizam, Luqman Ahmad
Tanveer, Waqas
Shafi, Ahmad
Ayub, Muhammad
Khan, Hassan Farid
Rustam, Behzad
Powiązania:
https://bibliotekanauki.pl/articles/102083.pdf
Data publikacji:
2019
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
incident flow angle
fluid elastic instability
flow-induced vibration
parallel triangular array
cross flow velocity
flexible tube
kąt przepływu
niestabilność sprężysta płynu
drgania indukowane przepływem
równoległy układ trójkątny
prędkość przepływu poprzecznego
elastyczna rura
Opis:
An experimental study on the incident flow angle effects on the vibration behavior was carried out on aluminum tube in parallel triangular tube bundle with P/D ratio of 1.375. Fluid elastic instability is the most fatal mechanism from all the vibration mechanisms and therefore must be dealt with a lot of attention. Experiments were performed on low speed water tunnel with the velocity of water ranges from 0.3 m/s to 0.7 m/s. The experiments were designed in a unique way to study the effects of incident flow angle on the vibration behavior. The monitored tube was mounted flexibly in an array of rigid tubes. The experiments were conducted on a flexible tube for different velocities ranging from 0.3 m/s to 0.7 m/s with different array rotated angles (0 to 90 degrees). It was observed that the vibration level was significantly high at 75 degree configuration as compared to other rotated angle configurations. It was also observed that the damping response is dispersed with all positive values, indicating that there is no instability in the tube.
Źródło:
Advances in Science and Technology. Research Journal; 2019, 13, 2; 186-194
2299-8624
Pojawia się w:
Advances in Science and Technology. Research Journal
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Temperature efficiency of heat exchangers in air handling units
Autorzy:
Michalak, Piotr
Grygierczyk, Stanisław
Powiązania:
https://bibliotekanauki.pl/articles/95368.pdf
Data publikacji:
2019
Wydawca:
Politechnika Koszalińska. Wydawnictwo Uczelniane
Tematy:
ventilation
heat recovery
rotary heat exchanger
cross-flow heat exchanger
temperature efficiency
PN-EN 308
wentylacja
odzysk ciepła
obrotowy wymiennik ciepła
krzyżowy wymiennik ciepła
sprawność temperaturowa
Opis:
In order to reduce ventilation heat loss and improve energy efficiency of low-energy buildings air-handling units (AHUs) with heat recovery are used. The article presents results of surveys performed in a passive building located in Katowice concerning the temperature efficiency of heat and cold recovery of two selected AHUs, with different heat exchangers. For this purpose the measurement data from the Building Management System (BMS) for the period 1.08.2015-31.07.2016 were used. The first unit was equipped with a rotary heat exchanger. Its average annual temperature efficiency of heat recovery was 47.2% annually. The efficiency of cold recovery amounted 52.9% on average for the warm half year. The second unit had a cross-flow exchanger. The average annual temperature efficiency of heat recovery in this device was 80.1%. The efficiency of cold recovery amounted 57.2% on average for the warm half year. Additional remarks concerning the temperature measurement in analysed units were also given.
Źródło:
Journal of Mechanical and Energy Engineering; 2019, 3, 3; 267-272
2544-0780
2544-1671
Pojawia się w:
Journal of Mechanical and Energy Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Treatment possibilities of reverse-flow sural flap in covering the defects of lower extremities
Autorzy:
Elsaftawy, Ahmed
Jabłecki, Jerzy
Domanasiewicz, Adam
Paruzel, Maciej
Kaczmarzyk, Janusz
Kaczmarzyk, Leszek
Powiązania:
https://bibliotekanauki.pl/articles/1396161.pdf
Data publikacji:
2013-04-01
Wydawca:
Index Copernicus International
Tematy:
local flaps
cross flap
reverse flow sural flap
perforator-based flap
Opis:
Soft tissue defects of the lower extremity pose an important surgical challenge, often because of inviability of primary covering. Therapeutic modalities of choice comprise of local perforator flaps, as well as of free flaps created with the use of microsurgical skills. However, these methods cannot be applied in patients with important comorbidities, and it is in such cases where the reverse sural flap proves to be the best solution. The aim of the study was to present the results of treating lower extremity defects with various modifications of the reverse sural flap. Material and methods. Sixteen patients, males aged 17-56 years, were operated on from 2007 to 2013. Diabetes with multiple complications, disseminated atheromatosis, and extensive soft tissue trauma involving the arteries crucial for microsurgica anastomoses were the most common reason disqualifying from the free and perforator-based flap techniques. Results. All of the patients achieved very good results; in two cases distal and marginal flap necrosis was observed which, once exiced, covered with granulation, and was successfully covered with a partialthickness skin graft. Conclusions. The reverse sural flap, technically easy, offers a viable, low-risk alternative to free and perforator-based flaps.
Źródło:
Polish Journal of Surgery; 2013, 85, 4; 192-197
0032-373X
2299-2847
Pojawia się w:
Polish Journal of Surgery
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Cross-waves and pulsating flows in the side-channel spillway - an experimental approach
Autorzy:
Azmeri, Azmeri
Ummah, Chairatun
Jemi, Faris Zahran
Faudli, Imam
Nasaiy, Qurratul 'Aini Benti
Powiązania:
https://bibliotekanauki.pl/articles/2203528.pdf
Data publikacji:
2023
Wydawca:
Instytut Technologiczno-Przyrodniczy
Tematy:
cross-waves
hydrodynamic force
physical model
pulsating flow
side-channel spillway
Opis:
Potentially hazardous side-channels of complex geometry need to be investigated using detailed hydraulic physical models. This study aims to analyse the cross-waves pattern and pulsating flow using a side-channel spillway physical model. This study compares the cross-waves pattern were measured using an experimental installation set to generate cross-waves on the surface (original series) with another structure that did not produce cross-waves (modified series). The results showed that the geometry of the left wall caused instability in flow patterns and secondary flows. The starting point of Q2 discharge was detected by minor turbulence on the water surface near the left wall at a water depth of 3.3 m at the starting point of the wall, but with no overtopping. Cross-waves formed downstream at the right wall crosswise, lower than at the left wall. The height of the cross-wave increased substantially from Q100 to Q1000 discharges leading to overtoppings near the left wall at a water depths of 4.2 and 5.0 m at the starting point of the wall, and near the right wall at a water depths of 3.8 and 4.0 m at the upstream point of the wall. The modifications provided optimal hydraulic conditions, i.e. elimination of cross-waves and non-uniform flows. The Vedernikov and Montouri numbers showed that both original and modified series did not enter the area where the pulsating flow occurred. This indicated that both series were free from the pulsating flow.
Źródło:
Journal of Water and Land Development; 2023, 56; 51--57
1429-7426
2083-4535
Pojawia się w:
Journal of Water and Land Development
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Badania stanu technicznego rozpylaczy płaskostrumieniowych użytkowanych w warunkach polowych
Testing technical condition of fan atomizers used in field conditions
Autorzy:
Koszel, M.
Powiązania:
https://bibliotekanauki.pl/articles/287761.pdf
Data publikacji:
2006
Wydawca:
Polskie Towarzystwo Inżynierii Rolniczej
Tematy:
rozpylacz płaskostrumieniowy
rozkład poprzeczny
natężenie wypływu
fan atomizer
cross distribution
flow out intensity
Opis:
Badano rozpylacze płaskostrumieniowe powszechnie użytkowane przez rolników. Oceniono wpływ zużycia rozpylaczy oraz ich położenie na belce polowej opryskiwacza na współczynnik nierównomierności rozkładu opadu rozpylonej cieczy (Cv). Stwierdzono wpływ ustawienia rozpylaczy na belce polowej na wartość współczynnika Cv. Ponadto wzrost natężenia wypływu cieczy z rozpylaczy nie zawsze powoduje pogorszenie współczynnika rozkładu opadu rozpylonej cieczy Cv.
Fan atomizers commonly used by farmers were put to tests. The analysis involved assessment of the effect of atomizers wear and their position at spraying machine field beam on sprayed liquid fall peaking factor (Cv). It has been proved that atomizers position at field beam affects the Cv factor value. Moreover, increase in intensity of liquid flow out of atomizers not always results in deterioration of the sprayed liquid fall peaking factor Cv.
Źródło:
Inżynieria Rolnicza; 2006, R. 10, nr 12(87), 12(87); 259-265
1429-7264
Pojawia się w:
Inżynieria Rolnicza
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies