Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "cooling water" wg kryterium: Temat


Tytuł:
Cooling water flow influence on power plant unit performance for various condenser configurations setup
Autorzy:
Dobkiewicz-Wieczorek, Ewa
Powiązania:
https://bibliotekanauki.pl/articles/2091367.pdf
Data publikacji:
2022
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
cooling water
power plant efficiency
cooling water flow control
CHP plant
efficiency
Opis:
This paper presents the influence of cooling water regulation on power plant net efficiency. It was examined whether, for the non-nominal low-pressure turbine load, it is justified to reduce the cooling water pump load, and how it would affect the unit net efficiency. Calculations for two types of power units were carried out: with condensing and extraction-condensing turbine. The tested condensing power plant consists of three surface condensers. The calculation included four condensers’ connections set up on the cooling water side to check how the cooling water system pressure drop affects the net unit performance. The result has confirmed that implementing serial connection decreases net efficiency when cooling water flow regulation is used, but the mixed connection should be applied when pump load is not controlled. It was proved that the cooling water flow control gives a profit for both units. Net efficiency for combined heat and power plant can be improved by 0.1–0.5 pp, the gain is remarkable below 60% of the low-pressure turbine part load. Flow control implementation in the unit with condensing turbine water control gives a similar profit just below 80% of the turbine load. Next, an influence of the additional limitations of a cooling water system (minimal total pump head, cooling tower) affecting the feasibility of implementing the water control has been considered. Applying a multi-cell forced draft cooling tower does not have a significant impact on results, but when a natural draft cooling tower is used, the flow control range is strongly reduced.
Źródło:
Archives of Thermodynamics; 2022, 43, 1; 141--167
1231-0956
2083-6023
Pojawia się w:
Archives of Thermodynamics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Technical Problems and Ecological Risks in Connection with Operation of Cooling Water Systems
Techniczne problem I zagrożenia ekologiczne związane z eksploatacją systemów wody chłodzącej
Autorzy:
Skoczylas, A.
Falewicz, P.
Powiązania:
https://bibliotekanauki.pl/articles/389734.pdf
Data publikacji:
2012
Wydawca:
Towarzystwo Chemii i Inżynierii Ekologicznej
Tematy:
układy wody chłodzącej
korozja
związki fosfonowe
cooling water systems
corrosion
phosphonic compounds
Opis:
Industrial water consumption in Poland is very high and reach over 10 billion m3/year, which forces the implementation of appropriate programs and technological solutions to reduce water consumption in industrial activity. Depending on the design system, operating conditions of water-powered cooling systems, they are exposed to varying degrees of corrosion, precipitation and deposition of sediments and the growth of microorganisms in water circulating. So important are measures aimed at raising the technical level of operation of industrial water systems. One of the most promising ways to prevent negative phenomena in the operation of cooling water systems is the use of organic inhibitors of complex multi-functional system to protect against corrosion, deposition of sediments and the development of microorganisms in the water circulation.
Zużycie wody przemysłowej w Polsce jest bardzo duże i wynosi ponad 10 mld m3/rok, co zmusza do wdrażania odpowiednich programów i rozwiązań technologicznych w celu zmniejszenia zapotrzebowania na wodę. W zależności od rozwiązań konstrukcyjnych, warunków eksploatacji układów chłodzących zasilanych wodą, narażone są one w różnym stopniu na korozję, wytrącanie i odkładanie się osadów oraz rozwój mikroorganizmów w wodzie obiegowej. Dlatego ważne są działania mające na celu podnoszenie poziomu technicznego eksploatacji przemysłowych układów wodnych. Jednym z najbardziej perspektywicznym sposobem zapobiegania negatywnych zjawisk występujących przy eksploatacji układów wody chłodzącej jest stosowanie ekologicznych wielofunkcyjnych inhibitorów kompleksowo chroniących układ przed korozją, odkładaniu się osadów i rozwojem mikroorganizmów w wodzie cyrkulacyjnej.
Źródło:
Ecological Chemistry and Engineering. A; 2012, 19, 9; 1115-1122
1898-6188
2084-4530
Pojawia się w:
Ecological Chemistry and Engineering. A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The effect of cooling water temperature on the performance of a BWR nuclear power plant
Autorzy:
Laskowski, Rafał
Theimech, Mohamad
Uzunow, Nikołaj
Powiązania:
https://bibliotekanauki.pl/articles/2195750.pdf
Data publikacji:
2021
Wydawca:
Centrum Rzeczoznawstwa Budowlanego Sp. z o.o.
Tematy:
nuclear power plant
cooling system
cooling water temperature
boiling water reactor
BWR
elektrownia jądrowa
układ chłodzenia
temperatura wody chłodzącej
reaktor wrzący
Opis:
Although PWR reactors make up the large majority of the world's nuclear power plants, BWR reactors also have a share in this industry. It is difficult to find data on the performance of a BWR power plant in off-design and variable load conditions in the literature. Therefore, the paper presents how cooling water temperature affects the efficiency and power output of a BWR unit. The qualitative effect of changes and the trend related to the effect of cooling water temperature on the performance of the power plant are known, but the quantitative effect has to be determined for specific power units. Depending on the location of the nuclear power plant, various temperatures of cooling water for use in condensers and thus various operating conditions of the cooling system can be achieved. To analyze how cooling water temperature affects the performance of the power unit, a model of a BWR power plant was developed using the Ebsilon software. The model was based on data provided in [1] concerning LaSalle County Nuclear Generating Station. Calculations showed that within the examined range of cooling water temperatures at the condenser inlet between 10 and 28oC the gross power output of the unit decreases by 91.405 MW and the gross efficiency drops by 2.773 percentage points.
Źródło:
Modern Engineering; 2021, 3; 5--13
2450-5501
Pojawia się w:
Modern Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Treatment of wastewater to meet the requirements for cooling water systems in jordan’s nuclear plants
Autorzy:
Al-Rawajfeh, A.E.
Araj, K.
Powiązania:
https://bibliotekanauki.pl/articles/184961.pdf
Data publikacji:
2013
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
cooling water
nuclear plants
wastewater treatment
scale deposition
schładzanie wody
elektrownia jądrowa
oczyszczanie ścieków
Opis:
Scaling and corrosion associated with the use of natural hard water in cooling towers during recirculation pose great problems from both economical and technical points of view, such as decreased system efficiency and increased frequency of chemical cleaning. Treated municipal wastewater (MWW) is a promising alternative to freshwater as power plant cooling system makeup water, especially in arid regions. In this work, hybrid systems of salt precipitation (SP), nanofiltration (NF) and reverse osmosis (RO) were investigated, as potential pretreatment processes for wastewater reuse as cooling water in the planned Jordan nuclear power plants. The As-Samra wastewater was used to calculate the potential of carbonate and sulfate scale formation. The results were compared to scale potentials from Palo Verde wastewater. Four cases were investigated; SP, NF, SP-RO and NF-RO. The SP pretreatment cases showed the highest monovalent to divalent ratio because of a high removal of Ca and Mg and addition of Na from the chemicals of the SP step. The NF pretreatment cases, showed the lowest calcium sulfate scale potential and this potential decreases with the % pretreatment. The scale amount increases very slightly with concentration times when the SP and NF product is desalinated by RO step.
Źródło:
Chemical and Process Engineering; 2013, 34, 2; 253-267
0208-6425
2300-1925
Pojawia się w:
Chemical and Process Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wystepowanie bakterii z rodzaju [Legionella] w systemach wody chlodniczej
Occurrence of bacteria from the Legionella genus in cooling water systems
Autorzy:
Matuszewska, R
Krogulska, B.
Powiązania:
https://bibliotekanauki.pl/articles/874257.pdf
Data publikacji:
2008
Wydawca:
Narodowy Instytut Zdrowia Publicznego. Państwowy Zakład Higieny
Tematy:
woda chlodnicza
klimatyzacja
bakterie
Legionella
wystepowanie
oznaczanie
cooling water
air conditioning
bacteria
occurrence
determination
Opis:
W publikacji przedstawiono wyniki badań próbek wody w kierunku wykrywania bakterii z rodzaju Legionella, z przemysłowych obiegów wody chłodniczej oraz systemów klimatyzacyjnych. Na 518 zbadanych próbek, pobranych w okresie od 1998 do 2006 roku, pałeczki Legionella zostały wykryte w 168 próbkach, co stanowiło 32,4% wszystkich zbadanych próbek. Najbardziej niebezpieczna Legionella pneumophila sg 1 była wykrywana w 11,3 % próbek pozytywnych. Niepokój budzi również wysoka liczba wyizolowanych bakterii z rodzaju Legionella (powyżej 103jtk/100ml), którą stwierdzono aż w 60% próbek wody pobranych z systemów wody chłodniczej i w 33% próbek wody związanych z klimatyzacją. Tak wysoki poziom zanieczyszczenia wymaga natychmiastowej interwencji (czyszczenie i dezynfekcja urządzeń). Uzyskane wyniki wskazują na realne zagrożenie zdrowotne jakie związane jest ze skażeniem wód chłodniczych pałeczkami Legionella. Należy zatem dążyć do powstania uregulowań prawnych, które nakładałyby obowiązek monitorowania wód chłodniczych w kierunku bakterii z rodzaju Legionella i prowadzenia odpowiednich działań naprawczych.
Results of Legionella bacteria study in water samples from industrial cooling water systems and airconditioner systems were presented. Legionella pneumophila was detected in 32,4%. of 518 examined water samples collected from 1998 to 2006. The most dangerous Legionella pneumophila sg 1 was detected in 11,3% of all positive samples. The high number (more than 104jtk/l) of isolated Legionella bacteria was determinated in 60% of water samples taken from cooling waters systems and 33% of samples of waters related with air-conditioning that is alarming. High pollution requires immediate intervention (installations cleaning and disinfection). Data indicated real health risk connected with Legionella pollution of cooling water. Creation of low regulations which will put the obligation of cooling water systems monitoring of Legionella bacteria occurrence and taking preventive measures is necessary.
Źródło:
Roczniki Państwowego Zakładu Higieny; 2008, 59, 4; 445-454
0035-7715
Pojawia się w:
Roczniki Państwowego Zakładu Higieny
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Razrabotka i issledovanie prisadki novogo tipa
Development and Testing of a New Kind of Additive
Autorzy:
Valisin, A.
Pimosenko, A.
Powiązania:
https://bibliotekanauki.pl/articles/359373.pdf
Data publikacji:
2006
Wydawca:
Akademia Morska w Szczecinie. Wydawnictwo AMSz
Tematy:
concentration
corrosion-erosion destruction
cooling water additive
chemical nickeling
cylinder liner
EXPLO-SHIP 2006
Opis:
The article considers the question of obtaining a new additive on the base of nickel salts for ship's diesel engine cooling water. The protective property of this additive results from chemical nickeling of surfaces to be cooled without using any power source. The article describes the results of testing the additive on a test rig equipped with a magnetostriction vibrator.
Źródło:
Zeszyty Naukowe Akademii Morskiej w Szczecinie; 2006, 10 (82); 399-406
1733-8670
2392-0378
Pojawia się w:
Zeszyty Naukowe Akademii Morskiej w Szczecinie
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Techniczne i ekologiczne problemy przy eksploatacji przemysłowych układów wody chłodzącej
Technical and environmental problems in the operation of industrial systems cooling water
Autorzy:
Skoczylas, A.
Falewicz, P.
Powiązania:
https://bibliotekanauki.pl/articles/126042.pdf
Data publikacji:
2011
Wydawca:
Towarzystwo Chemii i Inżynierii Ekologicznej
Tematy:
układy wody chłodzącej
korozja
ekologiczne inhibitory korozji
cooling water system
corrosion
ecological corrosion inhibitors
Opis:
Zużycie wody przemysłowej w Polsce jest bardzo duże i wynosi ponad 10 mld m3/rok, co zmusza do wdrażania odpowiednich programów i rozwiązań technologicznych w celu zmniejszenia zapotrzebowania na nią. W zależności od rozwiązań konstrukcyjnych, warunków eksploatacji układów chłodzących zasilanych wodą narażone są one w różnym stopniu na korozję, wytrącanie i odkładanie się osadów oraz rozwój mikroorganizmów w wodzie obiegowej. Dlatego istotne są działania mające na celu podnoszenie poziomu technicznego eksploatacji przemysłowych układów wodnych. Stosowanie ekologicznych wielofunkcyjnych inhibitorów wydaje się być jednym z najbardziej perspektywicznych sposobów chroniących układ przed korozją, odkładaniem się osadów i rozwojem mikroorganizmów w wodzie cyrkulacyjnej, występujących przy eksploatacji układów wody chłodzącej.
Industrial water consumption in Poland is very high and amounts to over 10 billion m3, which meansthal the implementation of relevant programs and technological solutions to reduce demand for water is needed. Depending on the design system, operating conditions of refrigeration systems powered by water, they are exposed to varying degrees of corrosion, precipitation and deposition of sediments and the development of microorganisms in the water circulation. So important are measures aimed at improving the technical operation of industrial water systems. One of the most promising way to prevent negative phenomena in the operation of the cooling water systems is the use of organic inhibitors of complex multi-functional system to protect against corrosion, deposition of sediments and the development of microorganisms in the water circulation.
Źródło:
Proceedings of ECOpole; 2011, 5, 2; 595-599
1898-617X
2084-4557
Pojawia się w:
Proceedings of ECOpole
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Procesy korozyjne w wieżach chłodniczych – badania stali zbrojeniowych w środowisku wody chłodniczej, uzdatnionej solami amonowymi
Corrosion processes in cooling towers
Autorzy:
Szymura, T.
Adamczyk, W.
Powiązania:
https://bibliotekanauki.pl/articles/391195.pdf
Data publikacji:
2013
Wydawca:
Politechnika Lubelska. Wydawnictwo Politechniki Lubelskiej
Tematy:
układy chłodnicze
woda chłodnicza
korozja metali
korozja żelbetu
inhibitory korozji
Cooling water
corrosion metals
corrosion concrete construction
cooling system
inhibitors
Opis:
Przeprowadzono badania korozji stali zbrojeniowych w uszkodzonych płaszczach chłodni kominowej w środowisku wody chłodniczej, uzdatnianej związkami siarczanu i chlorku amonu. Badania prowadzono normową metodą grawimetryczną i elektrochemiczną z wykorzystaniem potencjostatu. Badania wykazały, że odporność korozyjna w roztworach zawierających sole amonu o stężeniu 0,15 mola/dm3, obliczona na podstawie szybkości korozji, była podobna i wyniosła 6 (w skali od 1 do 10). Stal S235JRG2 wykazała nieco wyższą odporność w tych środowiskach.
Corrosion testing was performed on structural steel of a cooling tower in the environment of cooling water containing ammonium sulfates and ammonium chloride. The test were performed using gravimetric and electrochemical methods with the application of a potentiostat. The analyses clearly showed that the corrosion rate is higher in solutions that contain ammonium sulfate and that the S235JRG2 steel exhibits higher corrosion resistance in this environment.
Źródło:
Budownictwo i Architektura; 2013, 12, 3; 231-238
1899-0665
Pojawia się w:
Budownictwo i Architektura
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Experimental Study of Temperature Influence on the Performance of PV/T Cell under Jordan Climate Conditions
Autorzy:
Al-Odat, Mohammed Qassim
Powiązania:
https://bibliotekanauki.pl/articles/2202185.pdf
Data publikacji:
2022
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
PV module
electrical conversion
electrical efficiency
water cooling
cooling
cell temperature
Opis:
The electrical performance and the productivity of PV module depend on two main parameters, i.e. the radiation intensity and the cell operating temperature. The module electrical efficiency and productivity are significantly reduced as its temperature increases. Accordingly, cooling of PV modules is one of the most effective techniques to obtain higher efficiency and productivity as well as to reduce the degradation modes of PV modules due to high temperatures. This research work presents an experimental study carried out to investigate the effect of PV module cooling on the performance of PV module under Irbid city (Jordan) climate conditions. It was found that the electrical efficiency and the productivity of the PV modules were approximately enhanced by 14%. Therefore, water cooling of the PV modules is essential to enhance their performance.
Źródło:
Journal of Ecological Engineering; 2022, 23, 10; 80--88
2299-8993
Pojawia się w:
Journal of Ecological Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Increasing photovoltaic panel power through water cooling technique
Autorzy:
Matias, C. A.
Santos, L. M.
Alves, A. J.
Calixto, W. P.
Powiązania:
https://bibliotekanauki.pl/articles/136175.pdf
Data publikacji:
2017
Wydawca:
EEEIC International Barbara Leonowicz Szabłowska
Tematy:
photovoltaic panel
water cooling
increasing electrical efficiency
efficiency increase
Opis:
This paper presents the development of a cooling apparatus using water in a commercial photovoltaic panel in order to analyze the increased efficiency through decreased operating temperature. The system enables the application of reuse water flow, at ambient temperature, on the front surface of PV panel and is composed of an inclined plane support, a perforated aluminum profile and a water gutter. A luminaire was specially developed to simulate the solar radiation over the module under test in a closed room, free from the influence of external climatic conditions, to carry out the repetition of the experiment in controlled situations. The first case study was published at EEEIC2016 conference where the panel was submitted to different rates of water flow, from 1 L/min to 4 L/min. In the test conditions without cooling apparatus, the panel reached about 70°C and produced approximately 63Wh. With the cooling apparatus with water flow rate of 2 L/min, the module reached about 50°C and produced approximately 77Wh. However, it has been observed that this water flow was overestimated. A second case study was carried out in order to perform the threshold between the flow and the energy produced. The best ratio was flow of 0.6 L/min and net energy of 77.41Wh. Gain of 22.69% compared to the panel without the cooling system. The best water flow rate was of 0.6 L/min and net energy of 77.41Wh. Gain of 22.69% compared to the panel without the cooling system.
Źródło:
Transactions on Environment and Electrical Engineering; 2017, 2, 1; 60-66
2450-5730
Pojawia się w:
Transactions on Environment and Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies