Wyświetlanie 1-2 z 2
Tytuł:
Biomethane Emissions: Measurement in Wastewater Pond at Palm Oil Mill by Using TGS2611 Methane Gas Sensor
Autorzy:
Putro, Ledis Heru Saryono
Budianta, Dedik
Rohendi, Dedi
Rejo, Amin
Powiązania:
https://bibliotekanauki.pl/articles/123422.pdf
Data publikacji:
2019
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
methane emissions
CH4-meter
TGS2611 sensor
SHT11 sensor
anaerobic pond
POME
conversion coefficient
Opis:
Palm oil mill effluent (POME) contains high amounts of organic matter, potentially as a source of environmental pollution. The processing of POME in anaerobic ponds is produced by biomethane, which is a greenhouse gas and also is a potential as a renewable energy source. Indonesia is the world’s largest CPO producer, but POME processing is still mostly done by conventional methods without methane capture. In this system, the value of methane emitted into the atmosphere is unknown. This research focused on estimating the methane emissions in anaerobic ponds (AP) multiple feeding wastewater treatment plants (WWTPs) for land applications, with CH4-meter systems based on TGS2611 sensors, SHT11 and microcontrollers, and using closed static chambers. The sampling of wastewater and methane gas was carried out in October-November 2018. The results showed that the methane gas emissions in combined anaerobic ponds (AP2-AP1) and AP3 were 43,704 and 35,321 mg/m2/day respectively, and a total of 405.358 and 61.812 kg/day sequential on AP2-AP1 (9,275 m2) and AP3 (1,750 m m2). It was obtained from the correlation between methane emissions with removed COD as a conversion coefficient of 0.2107 kg CH4/kg COD removed. On the basis of linear regression with R22 0.9725, it was still below the theoretical value (stoichiometry) of 0.25 kg CH4/kg COD removed. From the conversion coefficient, COD removed, and the amount of POME in 2018, which was 104,179 m3, contributed to emitting 462 tons of methane from the entire anaerobic pond. This conversion coefficient can be used to quickly estimate the methane emissions in Indonesian palm oil mills.
Źródło:
Journal of Ecological Engineering; 2019, 20, 6; 25-35
2299-8993
Pojawia się w:
Journal of Ecological Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Methodical aspects of determination of parameters which characterize thermal balance of a plastic tunnel
Metodyczne aspekty wyznaczania parametrów charakteryzujących bilans cieplny tunelu foliowego
Autorzy:
Kurpaska, S.
Lis, W.
Vogelgesang, J.
Powiązania:
https://bibliotekanauki.pl/articles/93648.pdf
Data publikacji:
2016
Wydawca:
Polskie Towarzystwo Inżynierii Rolniczej
Tematy:
plastic tunnel
ratio of thermal transmittance
coefficient of solar radiation
conversion into heat
tunel foliowy
współczynnik przenikania ciepła
osłona
współczynnik promieniowania słonecznego
konwersja w ciepło
Opis:
The paper presents methodology of measuring the values which characterize the thermal balance in a horticultural facility. Thermal transmittance through a plastic tunnel cover and the ratio of solar radiation energy conversion into heat were analysed in detail. The research was carried out in real time with closed ventilators, where no plants were cultivated during the tests. The utility surface area was 144 m2, the cover was 289 m2 and its volume was 508 m3. Basing on the standard relations, first of all, thermal transmittance through a cover was measured. The ratio was measured with the use of standard criteria equations. Then, a correlation equation, which makes its course dependent on the climate parameters (the wind speed and temperature difference between the interior of the facility and its surroundings), was found. Knowing the course of the ratio in the function of the climate parameters, the value of the ratio of solar radiation conversion into heat stored in the facility was measured. Both parameters (thermal transmittance and solar radiation conversion ratios) were calculated from the thermal balance equaition where the change of the energy stored inside the facility was compared to the heat losses through a cover (for thenual transmittance) and the profit (in case of solar radiation conversion). For the obtained values, using the non-linear estimation procedure (with quasi-Newtom method with maintenance of the correlation coefficient of 0.001) the change of both ratios in the function of easily measured parameters of climate inside and outside the facility was found out. In the investigated conditions, the average value of thermal transmittance through a cover was 5.32 W·m-2·K-1, and the solar radiation conversion into heat was 0.36. The values and their course from the climate parameters inside and outside the facility may be used for controlling the amount of supplied heat and location of ventilators.
W pracy przedstawiono metodykę do wyznaczania wielkości charakteryzujące bilans cieplny w obiekcie ogrodniczym. Szczegółowej analizie poddano współczynnik przenikania ciepła przez transparentną osłonę tunelu foliowego oraz współczynnik konwersji energii promieniowania słonecznego w ciepło. Badania przeprowadzono w rzeczywistym obiekcie przy zamkniętych wietrznikach, w którym podczas badań nie uprawiano roślin. Powierzchnia użytkowa tunelu wynosiła 144 m2, osłony 289 m2, zaś jego pojemność była równa 508 m3. Bazując na standardowych zależnościach w pierwszej kolejności wyznaczono współczynnik przenikania ciepła przez osłonę. Współczynnik wyznaczono korzystając ze standardowych równań kryterialnych. W następnej kolejności znaleziono równanie korelacyjne uzależniające jego przebieg od parametrów klimatu (prędkość wiatru oraz różnica temperatury między wnętrzem obiektu a jego otoczeniem). Dysponując przebiegiem współ-czynnika w funkcji parametrów klimatu, w następnym etapie wyznaczono wartość współczynnika konwersji promieniowania słonecznego w ciepło zmagazynowane w obiekcie. Obydwa parametry (współczynnik przenikania ciepła oraz konwersji promieniowania słonecznego) wyliczono z równania bilansu ciepła, w którym porównano zmianę energii zmagazynowanej wewnątrz obiektu ze stratami ciepła przez osłonę (dla przenikania ciepła) oraz zyskiem (w przypadku konwersji promieniowania słonecznego). Dla uzyskanych wartości, korzystając z procedury estymacji nieliniowej (metodą quasi-Newtona przy zachowanym współczynniku zbieżności 0,001) znaleziono zmienność obydwu współczynników w funkcji łatwo mierzalnych parametrów klimatu wewnątrz i na zewnątrz obiektu. W badanych warunkach, średnia wartość współczynnika przenikania ciepła przez osłonę była równa 5,32 W·m-2·K-1, zaś współczynnika konwersji promieniowania słonecznego w ciepło wyniosła 0,36. Znalezione wartości i ich przebieg od parametrów klimatu wewnątrz i na zewnątrz obiektu można wykorzystać do sterowania ilością dostarczanego ciepła oraz położeniem wietrzników.
Źródło:
Agricultural Engineering; 2016, 20, 3; 83-93
2083-1587
Pojawia się w:
Agricultural Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-2 z 2

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies