Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "controlled rectifier" wg kryterium: Temat


Wyświetlanie 1-2 z 2
Tytuł:
Research on the operational performance of high speed permanent magnet generator with controlled rectifier in distributed generation
Autorzy:
Hongbo, Q.
Yanqi, W.
Cunxiang, Y.
Kaiqiang, H.
Powiązania:
https://bibliotekanauki.pl/articles/140696.pdf
Data publikacji:
2018
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
high speed permanent magnet generator
controlled rectifier
electromagnetic field
switching frequency
Opis:
The uncontrolled rectifier and controlled rectifier which use fixed switching frequency control strategy are applied usually during the working of a high-power high- speed permanent magnet generator (HSPMG). Even for the controlled rectifier, it will generate harmonics. The electromagnetic performance of the HSPMG is also affected by these harmonics. In this paper, the influences of the fixed switching frequency control strategy on a HSPMG were studied. Based on the Fourier theory, the harmonic currents of the generator were analyzed, and the change of harmonic distribution range and current total harmonic distortion (THD) were obtained. By using an indirect field-circuit coupling method, the influences of the fixed switching frequency control strategy on the losses and torque of the generator were analyzed. The relations between the switching frequency and the losses and torque of the generator were obtained, and the change mechanism of the loss was revealed. The obtained conclusions can provide reference for the optimized choice of the switching frequency of the distributed generation system with the HSPMG. It can also provide support for the HSPMG electromagnetic structural optimization and the optimization of the loss and harmonic on the system level.
Źródło:
Archives of Electrical Engineering; 2018, 67, 4; 899-913
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Design and construction of a polygon-connected autotransformer-based 36-pulse AC-DC converter for power quality improvement in retrofit applications
Autorzy:
Abdollahi, R.
Powiązania:
https://bibliotekanauki.pl/articles/202052.pdf
Data publikacji:
2015
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
AC-DC converter
polygon autotransformer
power quality
36-pulse rectifier
direct torque controlled induction motor drive (DTCIMD)
konwerter AC-DC
jakość energii
prostownik impulsowy
DTCIMD
Opis:
This paper presents the design and analysis of a polygon connected autotransformer based 36-phase AC-DC converter which supplies direct torque controlled induction motor drives (DTCIMD’s) in order to have better power quality conditions at the point of common coupling. The proposed converter output voltage is accomplished via two paralleled eighteen-pulse AC-DC converters each of them consisting of nine-phase diode bridge rectifier. An autotransformer is designed to supply the rectifier. The design procedure of magnetics is in a way such that makes it suitable for retrofit applications where a six-pulse diode bridge rectifier is being utilized. The proposed structure improves power quality criteria at ac mains and makes them consistent with the IEEE-519 standard requirements for varying loads. Furthermore, near unity power factor is obtained for a wide range of DTCIMD operation. A comparison is made between 6-pulse and proposed converters from view point of power quality indices. Results show that input current total harmonic distortion (THD) is less than 4% for the proposed topology at variable loads. A laboratory prototype of the proposed Polygon-Connected autotransformer-based 36-pulse AC-DC converter is developed and test results are presented to validate the developed design procedure and the simulation models of this AC-DC converter under varying loads.
Źródło:
Bulletin of the Polish Academy of Sciences. Technical Sciences; 2015, 63, 2; 353-362
0239-7528
Pojawia się w:
Bulletin of the Polish Academy of Sciences. Technical Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-2 z 2

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies