Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "contamination analysis" wg kryterium: Temat


Tytuł:
Microarray Inspector: tissue cross contamination detection tool for microarray data
Autorzy:
Stępniak, Piotr
Maycock, Matthew
Wojdan, Konrad
Markowska, Monika
Perun, Serhiy
Srivastava, Aashish
Wyrwicz, Lucjan
Świrski, Konrad
Powiązania:
https://bibliotekanauki.pl/articles/1039460.pdf
Data publikacji:
2013
Wydawca:
Polskie Towarzystwo Biochemiczne
Tematy:
microarray
transcription profiling
contamination analysis
adipose tissue
cancer
data quality
Opis:
Microarray technology changed the landscape of contemporary life sciences by providing vast amounts of expression data. Researchers are building up repositories of experiment results with various conditions and samples which serve the scientific community as a precious resource. Ensuring that the sample is of high quality is of utmost importance to this effort. The task is complicated by the fact that in many cases datasets lack information concerning pre-experimental quality assessment. Transcription profiling of tissue samples may be invalidated by an error caused by heterogeneity of the material. The risk of tissue cross contamination is especially high in oncological studies, where it is often difficult to extract the sample. Therefore, there is a need of developing a method detecting tissue contamination in a post-experimental phase. We propose Microarray Inspector: customizable, user-friendly software that enables easy detection of samples containing mixed tissue types. The advantage of the tool is that it uses raw expression data files and analyses each array independently. In addition, the system allows the user to adjust the criteria of the analysis to conform to individual needs and research requirements. The final output of the program contains comfortable to read reports about tissue contamination assessment with detailed information about the test parameters and results. Microarray Inspector provides a list of contaminant biomarkers needed in the analysis of adipose tissue contamination. Using real data (datasets from public repositories) and our tool, we confirmed high specificity of the software in detecting contamination. The results indicated the presence of adipose tissue admixture in a range from approximately 4% to 13% in several tested surgical samples.
Źródło:
Acta Biochimica Polonica; 2013, 60, 4; 647-655
0001-527X
Pojawia się w:
Acta Biochimica Polonica
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Rola i miejsce Centralnego Ośrodka Analizy Skażeń w Krajowym Systemie Wykrywania Skażeń i Alarmowania
Paper "Role and place of CBRN Area Control Centre in National Warning and Reporting System"
Autorzy:
Karasińska, A.
Powiązania:
https://bibliotekanauki.pl/articles/143246.pdf
Data publikacji:
2012
Wydawca:
Stowarzyszenie Inżynierów i Techników Przemysłu Chemicznego. Zakład Wydawniczy CHEMPRESS-SITPChem
Tematy:
zagrożenia
toksyczne środki przemysłowe
analiza skażeń
zarządzanie kryzysowe
monitoring
hazard
contamination analysis
crisis management
Opis:
W najnowszej historii ludzkość była świadkiem wielu wydarzeńdecydujących o życiu jednostek, społeczeństw i całych narodów.Wydarzenia te niosły ze sobą szereg zmian, wśród których pojawiałysię także nowe zagrożenia, w tym zagrożenie skażeniami. Przełomowemomenty w dziejach świata związane z pojawieniem siętych zagrożeń to użycie przez Niemców broni chemicznej podczasI wojny światowej, zbudowanie przez Stany Zjednoczone i użyciepo raz pierwszy broni jądrowej, rozwój przemysłu i wykorzystaniew nim na szeroką skalę Toksycznych Środków Przemysłowych, powstanie zauważalnych zmian klimatycznych, terroryzm. Zagrożeniate powodują konieczność utrzymywania przez państwa wyspecjalizowanych służb przeznaczonych do reagowania na nie. W artykule przedstawiono rolę i zadania Centralnego Ośrodka Analizy Skażeń w Krajowym Systemie Wykrywania Skażeń i Alarmowania. Zaprezentowano elementy Ośrodka realizujące zamierzenia z zakresu zarządzania kryzysowego, w tym Centrum Dyspozycyjne KSWSiA i Mobilne Laboratorium OPBMR. Wskazano niezbędne perspektywy rozwoju zdeterminowane koniecznością sprostania wymogom współczesności związane m. in. z koniecznością zapewnienia automatyzacji wykrywania skażeń oraz przesyłania informacji o skażeniach, a także sporządzania prognoz i analiz.
Paper "Role and place of CBRN Area Control Centre in National Warning and Reporting System" concerns issue of reaction to contamination hazard. The beginning and the first part of paper contains information about contamination hazard. Additionally, it presents the most important events in world history connected with weapon of mass destruction strikes and releases of the toxic industrial compounds. Furthermore, in this part are presented components of crisis management system in Poland. Second (main) part of paper describes the role of CBRN Area Control Centre in Warning and Reporting System of Polish Armed Forces as well as National Warning and Reporting System. Moreover author presents the main tasks and responsibilities of CBRN Area Control Centre's components dedicated to response to contamination threats. In conclusion author presents his remarks and findings concerning the prospects of National Warning and Reporting System's and CBRN Area Control Centre's development.
Źródło:
Chemik; 2012, 66, 3; 206-211
0009-2886
Pojawia się w:
Chemik
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Lead and cadmium content in wheat grain from different regions of Poland and risk analysis
Autorzy:
Jędrzejczak, Renata
Ręczajska, Wiesława
Powiązania:
https://bibliotekanauki.pl/articles/2174347.pdf
Data publikacji:
2022
Wydawca:
Instytut Technologiczno-Przyrodniczy
Tematy:
contamination
Polska
risk analysis
excessive content
toxic metals
wheat
Opis:
The level of wheat grain contamination with lead and cadmium was determined using electrothermal atomic absorption spectrometry with Zeeman background correction (ETAAS) after microwave digestion. The obtained limits of quantification were 0.001 mg∙kg-1, for both metals. A total of 300 samples of wheat grain from agricultural regions of Poland were examined, 150 each from the two consecutive harvest years 2017 and 2018. None of the tested samples exceeded the maximum level of these metals, as specified in the European regulations. The contents of lead and cadmium in wheat grain from both years of harvest ranged from <0.001 to 0.098 mg∙kg-1 and from 0.006 to 0.098 mg∙kg-1, respectively. Despite similar ranges of these metals, the highest lead contents were two times lower than the maximum limit value, while the highest cadmium contents were close to it. As for lead, a significantly higher (p < 0.05) mean content of this metal was found in wheat grain from the 2018 harvest compared to 2017 and in the western compared to eastern regions of the country. However, the cadmium contents did not differ significantly between the two harvest years, but were significantly higher (p < 0.05) in wheat grain from the southern regions compared to northern regions of Poland. Additionally, the highest contents of cadmium, close to the maximum limit, were found in the South-West region and in the both years of harvest. The risk analysis of the occurrence of the excessive contents of toxic metals in wheat grain showed a low risk level for lead in all investigated regions, and a medium level for cadmium, in general.
Źródło:
Journal of Water and Land Development; 2022, 55; 192--199
1429-7426
2083-4535
Pojawia się w:
Journal of Water and Land Development
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Geochemistry of surface sediments from the northwestern Gulf of Mexico : implications for provenance and heavy metal contamination
Autorzy:
Armstrong-Altrin, John S.
Botello, Alfonso V.
Villanueva, Susana F.
Soto, Luis A.
Powiązania:
https://bibliotekanauki.pl/articles/2058576.pdf
Data publikacji:
2019
Wydawca:
Państwowy Instytut Geologiczny – Państwowy Instytut Badawczy
Tematy:
Tamaulipas
deep-sea sediments
enrichment factor
contamination
principle component analysis
Opis:
Thirty-five near-surface sediment samples were recovered from the continental shelf and upper slope regions of the north-western (NW) Gulf of Mexico. The geochemical data of the sediments recovered were examined to investigate the weathering intensity, provenance, palaeo-oxygenation condition, and level of heavy metal contamination. The sediments analysed showed a moderate to high intensity of chemical weathering. Major and trace element concentrations indicated a terrigenous origin, closely related to the weathering of rocks rich in aluminosilicates. The results of this study further revealed that major rivers, the Bravo and Soto La Marina, played an important role in delivering sediments to the study area. The concentration of transition trace elements such as Cr, Cu, Ni, and V revealed that the sediments were derived from intermediate rocks such as andesite. The V/Cr, Ni/Co, and Cu/Zn ratios in the sediments were <2, <5, and <1, respectively, suggesting a depositional process occurred under well-oxygenated conditions. Principle Component Analysis (PCA) did not show a significant difference in sediment texture between the continental shelf and slope areas. The enrichment factor (EF) and Geo-accumulation index (lgeo) values were <2 and <1, respectively, suggesting the absence of an anthropogenic input.
Źródło:
Geological Quarterly; 2019, 63, 3; 522--538
1641-7291
Pojawia się w:
Geological Quarterly
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Factors Affecting Water Quality in a Water Supply Network
Autorzy:
Jachimowski, A.
Powiązania:
https://bibliotekanauki.pl/articles/124812.pdf
Data publikacji:
2017
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
factor analysis
secondary contamination of water
water supply network
water quality
Opis:
An effect of factors determining water quality in the water supply network in Kraków is assessed. The data collected over a four-year research period included quality parameters of water taken from the water distribution system in the period between 1 January 2011 and 31 December 2014. In the analysis the supply zones of four municipal water treatment plants in Krakow were considered. The selection of 29 water sampling points within the supply area allowed comparing water quality with respect to operational and technological aspects. Factor analysis enabled 4 components explaining correlations between tap water quality variables to be distinguished. It follows from the research performed that the obtained factors applied to 77% of overall water variability. The highest share was assigned to factor 1 that explained 32% of the chemical composition of water under consideration and was correlated with calcium, conductance, nitrates (V), magnesium and to a moderate extent with Σ THM (with negative sign).
Źródło:
Journal of Ecological Engineering; 2017, 18, 4; 110-117
2299-8993
Pojawia się w:
Journal of Ecological Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wykorzystanie instrumentów wirtualnych do określania stopnia zanieczyszczenia mikrobiologicznego ciekłych produktów spożywczych
Application of virtual instruments to determine microbiological contamination level of liquid food products
Autorzy:
Kapica, J.
Makarski, P.
Powiązania:
https://bibliotekanauki.pl/articles/288014.pdf
Data publikacji:
2009
Wydawca:
Polskie Towarzystwo Inżynierii Rolniczej
Tematy:
analiza obrazu
zanieczyszczenie mikrobiologiczne
instrumenty wirtualne
image analysis
microbiological contamination
virtual instruments
Opis:
Artykuł przedstawia ocenę możliwości wykorzystania cyfrowych technik analizy obrazu do określania stopnia skażenia drobnoustrojami ciekłych produktów spożywczych. Sygnał wyjściowy kamery sprzęgniętej z mikroskopem optycznym poddawano cyfrowej analizie obrazu przy pomocy aplikacji napisanej w środowisku LabView 8.5. Do badań wykorzystano spreparowane próbki soków, uprzednio w sposób kontrolowany zanieczyszczone mikrobiologicznie.
The paper presents assessment of possibility to employ digital image analysis to determine contamination level of liquid food products with microbes. Output signal of a digital camera coupled with an optical microscope was digitally processed by an application written in LabView 8.5 graphical programming environment. In the tests, samples of fruit juice contaminated with microbes were used.
Źródło:
Inżynieria Rolnicza; 2009, R. 13, nr 9, 9; 101-106
1429-7264
Pojawia się w:
Inżynieria Rolnicza
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Study of waste dumps impact on the adjacent areas
Issledovanie vozdejjstvija teppikonov na prolegajushhie selskokhozjaiistvennye zemli
Autorzy:
Savelieva, E.
Powiązania:
https://bibliotekanauki.pl/articles/793673.pdf
Data publikacji:
2014
Wydawca:
Komisja Motoryzacji i Energetyki Rolnictwa
Tematy:
waste dump
agricultural soil
contamination
vegetation analysis
heavy metal content
biogeochemical barrier
Źródło:
Teka Komisji Motoryzacji i Energetyki Rolnictwa; 2014, 14, 2
1641-7739
Pojawia się w:
Teka Komisji Motoryzacji i Energetyki Rolnictwa
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Extraction and analysis of carotenoids from the New Zealand sea urchin Evechinus chloroticus gonads
Autorzy:
Garama, Daniel
Bremer, Phil
Carne, Alan
Powiązania:
https://bibliotekanauki.pl/articles/1039782.pdf
Data publikacji:
2012
Wydawca:
Polskie Towarzystwo Biochemiczne
Tematy:
Evechinus chloroticus
carotenoid extract lipid contamination
sea urchin gonad
carotenoid extraction and analysis
Opis:
Sea urchin gonad (roe) is a highly valued food in Japan and North America. Gonad price is strongly influenced by quality, with appearance, especially colour being a major determinant. Previous attempts to extract a carotenoid profile from the New Zealand sea urchin species Evechinus chloroticus have been challenging due to the large amount of lipid present in the gonad. A carotenoid extraction and high performance liquid chromatography (HPLC) analysis method was developed to reduce lipid contamination by incorporating a saponification and lipid cold precipitation in the extraction procedure. This method enabled greater carotenoid purity and enhanced analysis by HPLC. Echinenone was found to be the main carotenoid present in all E. chloroticus gonads. Dark coloured gonads contained higher levels of fucoxanthin/fucoxanthinol, β-carotene and xanthophylls such as astaxanthin and canthaxanthin. This information on the modification and deposition of carotenoids will help in the development of diets to enhance gonad colour.
Źródło:
Acta Biochimica Polonica; 2012, 59, 1; 83-85
0001-527X
Pojawia się w:
Acta Biochimica Polonica
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Zawartość steroli w korze po procesie wysokotemperaturowego suszenia tarcicy w komorowych suszarkach konwekcyjnych
Sterol content in bark after high-temperature drying of wood in convection driers
Autorzy:
Szwajkowska-Michałek, L.
Rogoziński, T.
Stuper-Szablewska, K.
Powiązania:
https://bibliotekanauki.pl/articles/980217.pdf
Data publikacji:
2019
Wydawca:
Polskie Towarzystwo Leśne
Tematy:
surowce drzewne
tarcica
suszenie wysokotemperaturowe
suszaki komorowe konwekcyjne
kora
zawartosc steroli
bark
contamination
uplc analysis
Opis:
Bark is a waste material in the furniture industry. It is mainly used for mulching in gardens. To fulfil its task in that field, bark must be microbiologically clean. Ergosterol (ERG) is the main sterol of the fungal cell wall. The research aimed to assess the usefulness of ergosterol concentration analysis for its use in the wood industry in order to quickly assess the level of microscopic contamination of the bark after the drying process. We tested the bark of oak, beech, hornbeam, spruce and pine in terms of ERG concentration and endogenous sterols content. The highest concentration of ERG was obtained for bark of coniferous species (1483.0 and 227.6 mg/kg for spruce and pine respectively), while much lower was found for deciduous (27.4−127.7 mg/kg). No sterols were found in the bark of deciduous trees after the drying process, with the exception of campesterol which was detected only in bark of beech and hornbeam. However, they were found in samples of conifer bark at the level of 1.6−1.78 mg/kg. The bark of deciduous trees is safer in terms of microbiology, and thus can be used in various industries as a secondary raw material.
Źródło:
Sylwan; 2019, 163, 07; 610-616
0039-7660
Pojawia się w:
Sylwan
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies