Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "contact profilometer" wg kryterium: Temat


Wyświetlanie 1-4 z 4
Tytuł:
The effect of measurement method for assessing stereometric structure of surface
Autorzy:
Pelc, A.
Starosta, R.
Powiązania:
https://bibliotekanauki.pl/articles/245502.pdf
Data publikacji:
2017
Wydawca:
Instytut Techniczny Wojsk Lotniczych
Tematy:
top layer
roughness
contact profilometer
confocal laser microscope
surface topography
Opis:
The article presents the influence of measuring methods of surfaces topography evaluation. Surface topography was measured using a mechanical, contact method by Hommel Tester T-8000-R60 profilometer (Gdynia Maritime University) and using the contactless, optical method by Olympus Lext OLS4100 Confocal Laser Scanning Microscope (Gdynia Maritime University). A pattern of roughness grade 4 sample was studied (standards PN-58/M-02425 (Ra=10 μm, Rz=40 μm)). Seven measurements were made on each of devices, resulting in a more accurate stereometric image of the sample surface. The area of the test was 1.5×1.5 mm. The radius of the edge of the blade imaging the surface used in the contact method was 2 μm. In the case of the optical method, the test sample surface was subjected to a laser light 405 nm long. This article describes the principle of used measuring instrument operation and their advantages and disadvantages. The results and descriptive statistics (Mann–Whitney U test, Kolmogorov–Smirnov test) of surface altitude parameters, such as Sa, Sp, Sq, Sv, Sz. There were statistically significant differences in topography values between measurements by T-8000 profilometer and Confocal Laser Scanning Microscope. It was noted that the values of the parameters Sa, Sq are higher with the T-8000 profilometer as a measuring device. The parameters Sp, Sv, Sz have a higher value, when measured on a Confocal Laser Scanning Microscope.
Źródło:
Journal of KONES; 2017, 24, 2; 177-182
1231-4005
2354-0133
Pojawia się w:
Journal of KONES
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Differences in Roughness Parameter Values from Skid and Skidless Contact Stylus Profilometers
Autorzy:
Grochalski, Karol
Mendak, Michał
Jakubowicz, Michał
Gapiński, Bartosz
Swojak, Natalia
Wieczorowski, Michał
Krawczyk, Aleksandra
Powiązania:
https://bibliotekanauki.pl/articles/2024198.pdf
Data publikacji:
2021
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
contact profilometer
portable profilometer
roughness parameters
skid devices
skidless devices
profilometr kontaktowy
profilometr przenośny
parametry chropowatości
urządzenia poślizgowe
urządzenia bezpoślizgowe
Opis:
Contact stylus profilometry is the leading surface texture measuring method in many manufacturing industries. For years it has been unmatched in terms of accuracy and reliability. Advancements in technology have led to the improvements in the profilometer design. A stylus can either have a built in skid or be skidless. In this study, the influence of skid on the measurement accuracy and repeatability was evaluated. Four different contact stylus profilometers were used to measure three standard roughness artifacts each. Every set of measurements consisted of 50 repetitions of the same profile, with the same parameters. Out of these profiles, five roughness parameters were calculated and were subjected to a statistical analysis. Relative errors of these parameters were also considered and presented individually for each roughness standard. Researchers found differences in the measurement results dispersion of various roughness parameters between the three roughness standards. The presented results of the measurements clearly indicated that there is a dispersion of the obtained values for the older type of contact stylus profilometer (P1, skid). The skidless portable devices, P2 and P3, have better measurement resolution, which results in a noticeably lower dispersion of measured values. A tabletop, stationary device utilizes a skidless measuring probe. It has both the best resolution and the highest rigidity, which results in the lowest dispersion of measured values. The lowest relative error of the Ra parameter was determined for the P2 device (9.2%) and the highest was determined for the P3 device (72.6%).
Źródło:
Advances in Science and Technology. Research Journal; 2021, 15, 1; 58-70
2299-8624
Pojawia się w:
Advances in Science and Technology. Research Journal
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analysis of influence of the shape of cutting insert on change of the parameter value describing the deviation of the profile of surface roughness
Autorzy:
Pelc, A.
Powiązania:
https://bibliotekanauki.pl/articles/244679.pdf
Data publikacji:
2018
Wydawca:
Instytut Techniczny Wojsk Lotniczych
Tematy:
surface roughness
turning machining
cutting insert
technological quality
contact profilometer
chropowatość powierzchni
jakość technologiczna
profilometr stykowy
Opis:
The article presents the influence of the shape of the cutting insert on the surface roughness of the material after medium-fine turning machining. The analysis of measurements of the Ra parameter describing the arithmetic mean deviation of the surface roughness profile from the centre line of the profile by the mechanical and contact method was made using the Hommel Etamic Waveline 20 profile (Gdynia Maritime University). The tests were carried out on three stainless steel X2CrNiMo17-12-2 / 1.4404 shafts with a diameter of 80 mm, subjected to medium-precision turning machining at a length of 270 mm, using three cutting inserts made of tungsten carbide shaped T – triangular, C – rhombic, W – trigonal manufactured by Pafana. Values of used parameters are turning speed Vc = 150 m/min, depth of cut ap = 2 mm and feed f = 0.2 mm/rev. The parameters have been selected according to the manufacturer’s recommendations. The tests were carried out three times, five measurements on the length of the turned part of the rollers. The first test was made after collecting one layer of material, the second test was carried out after collecting five layers of material, and the third test was made after collecting nine layers of material. The article describes the differences between the used tiles and their effect on surface roughness, presents the results of the research, charts of measurements with averaged values and descriptive statistics of the Ra parameter were presented. It was noted that for all measurements of the Ra parameter, the smallest values were obtained using a W-shaped cutting insert. The Ra parameter using the C and T shaped plates increases with each subsequent measurement. The largest value of the Ra parameter is obtained using the T.
Źródło:
Journal of KONES; 2018, 25, 1; 317-323
1231-4005
2354-0133
Pojawia się w:
Journal of KONES
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Laser profilometers for surface inspection and profile measurement
Profilometry laserowe do kontroli jakości i pomiarów profilu powierzchni
Autorzy:
Giesko, T.
Zbrowski, A.
Czajka, P.
Powiązania:
https://bibliotekanauki.pl/articles/257675.pdf
Data publikacji:
2007
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Technologii Eksploatacji - Państwowy Instytut Badawczy
Tematy:
kontrola
jakość powierzchni
pomiar profilu powierzchni
pomiar bezkontaktowy
triangulacja laserowa
profilometr laserowy
wizualizacja powierzchni 3D
surface inspection
surface profile measurement
non-contact measurement
laser triangulation
laser profilometer
3D surface visualisation
Opis:
This paper presents the developed 3D profilometers for surface inspection and profile measurement based on the triangulation principle. The applied compact high-resolution laser triangulation sensors with the mechatronics positioning system and computer data analysis enable the surface profile reconstruction for applications in industry as well as in research. The application tests were done on various specimens. Suitable filters can be applied to eliminate signal noise and disturbances and to improve the computer image visualisation.
Artykuł przedstawia opracowane profilometry 3D do inspekcji powierzchni i pomiarów jej profilu w oparciu o zasadę triangulacji. Zastosowane triangulacyjne głowice laserowe wysokiej rozdzielczości z mechatronicznym systemem pozycjonowania i komputerową analizą danych umożliwiają odtwarzanie zarysu powierzchni do zastosowań w przemyśle i badaniach naukowych. Testy zostały wykonane na różnych próbkach. W celu eliminacji szumów oraz zakłóceń i uzyskania wizualizacji komputerowej zastosowano odpowiednie filtry.
Źródło:
Problemy Eksploatacji; 2007, 1; 97-108
1232-9312
Pojawia się w:
Problemy Eksploatacji
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-4 z 4

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies