Study of the effectiveness of the turbine condenser air extraction system using hydro ejectors
Autorzy:
Badur, J.
Kowalczyk, T.
Ziółkowski, P.
Tokarczyk, P.
Woźniak, M.
Powiązania:
https://bibliotekanauki.pl/articles/175162.pdf
Data publikacji:
2016
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
condensation
steam condenser
Venturi nozzle
Dalton’s law
partial pressure
Opis:
The aim of the paper is to investigate the effectiveness of the 18K380 steam turbine condenser air extraction system using hydro ejectors. Motivation for the analysis was a need of improvement of the energy conversion ratio of the power plant. To achieve this goal it was necessary to establish efficiency of each subsystem of the energy cycle. The air extraction system is not a highly power consuming system but it has great impact on the steam cycle efficiency by influence on the condensation temperature. The air extraction system effectiveness depends on a weather conditions, exactly on the ambient temperature, which raises the question whether it is worth to modernize the hydro ejectors or replace them by a centrifugal vacuum pumps. To establish the vacuum system effectiveness a new innovative mass flow measuring system has been implemented to measure an air-steam mixture flow and the fraction of the air mass in the mixture. The measuring system is based on a Venturi nozzle supplemented with a temperature drop during the mixture expansion.
Źródło:
Transactions of the Institute of Fluid-Flow Machinery; 2016, 131; 41-53
0079-3205
Pojawia się w:
Transactions of the Institute of Fluid-Flow Machinery
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Equality cases for condenser capacity inequalities under symmetrization
Autorzy:
Betsakos, Dimitrios
Pouliasis, Stamatis
Powiązania:
https://bibliotekanauki.pl/articles/747114.pdf
Data publikacji:
2012
Wydawca:
Uniwersytet Marii Curie-Skłodowskiej. Wydawnictwo Uniwersytetu Marii Curie-Skłodowskiej
Tematy:
Steiner symmetrization
Schwarz symmetrization
polarization
condenser
capacity
Green function
Opis:
It is well known that certain transformations decrease the capacity of a condenser. We prove equality statements for the condenser capacity inequalities under symmetrization and polarization without connectivity restrictions on the condenser and without regularity assumptions on the boundary of the condenser.
Źródło:
Annales Universitatis Mariae Curie-Skłodowska, sectio A – Mathematica; 2012, 66, 2
0365-1029
2083-7402
Pojawia się w:
Annales Universitatis Mariae Curie-Skłodowska, sectio A – Mathematica
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Heat transfer during condensation of refrigerants in tubular minichannels
Autorzy:
Bohdal, T.
Charun, H.
Sikora, M.
Powiązania:
https://bibliotekanauki.pl/articles/239949.pdf
Data publikacji:
2012
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
chłodzenie
kompaktowy kondensator
kondensacja w minikanałach
wymiana ciepła
compact condenser
condensation in minichannels
heat transfer
refrigeration
Opis:
Abstract The present paper describes the results of experimental investigations of heat transfer during condensation of R134a, R404A and R407C in pipe minichannels with internal diameters 0.31-3.30 mm. The results concern investigations of the local heat transfer coefficient. The results were compared with the correlations proposed by other authors. Within the range of examined parameters of the condensation process in minichannels made of stainless steel, it was established that the values of the heat transfer coefficient may be described with Akers et al., Mikielewicz and Shah correlations within a limited range of the mass flux density of the refrigerant and the minichannel diameter. On the basis of experimental investigations, the authors proposed their own correlation for the calculation of local heat transfer coefficient.
Źródło:
Archives of Thermodynamics; 2012, 33, 2; 3-22
1231-0956
2083-6023
Pojawia się w:
Archives of Thermodynamics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Pressure drop during condensation of refrigerants in pipe minichannels
Autorzy:
Bohdal, T.
Charun, H.
Sikora, M.
Powiązania:
https://bibliotekanauki.pl/articles/240165.pdf
Data publikacji:
2012
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
kompaktowy kondensator
przepływ
skraplanie
skraplaniea w minikanałach
spadek ciśnienia
compact condenser
condensation in minichannels
pressure drop during flow in condensation
Opis:
The present paper describes results of experimental investigations of pressure drop during the condensation of R134a, R404a and R407C refrigerants in pipe minichannels with internal diameter 0.31-3.30 mm. The results concern investigations of the mean and local pressure drop in single minichannels. The results of experimental investigations were compared with the calculations according to the correlations proposed by other authors. A pressure drop during the condensation of refrigerants is described in a satisfactory manner with Friedel and Garimella correlations. On the basis of the experimental investigations, the authors proposed their own correlation for calculation of local pressure drop during condensation in single minichannels.
Źródło:
Archives of Thermodynamics; 2012, 33, 1; 87-106
1231-0956
2083-6023
Pojawia się w:
Archives of Thermodynamics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Modeling of KERENA emergency condenser
Autorzy:
Bryk, R.
Schmidt, H.
Mull, T.
Wagner, T.
Ganzmann, I.
Herbst, O.
Powiązania:
https://bibliotekanauki.pl/articles/240358.pdf
Data publikacji:
2017
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
condensation
Kerena
emergency condenser
Modelica
OpenModelica
kondensacja
kondensator awaryjny
Opis:
KERENA is an innovative boiling water reactor concept equipped with several passive safety systems. For the experimental verification of performance of the systems and for codes validation, the Integral Test Stand Karlstein (INKA) was built in Karlstein, Germany. The emergency condenser (EC) system transfers heat from the reactor pressure vessel (RPV) to the core flooding pool in case of water level decrease in the RPV. EC is composed of a large number of slightly inclined tubes. During accident conditions, steam enters into the tubes and condenses due to the contact of the tubes with cold water at the secondary side. The condensed water flows then back to the RPV due to gravity. In this paper two approaches for modeling of condensation in slightly inclined tubes are compared and verified against experiments. The first approach is based on the flow regime map. Depending on the regime, heat transfer coefficient is calculated according to specific semi-empirical correlation. The second approach uses a general, fully-empirical correlation. The models are developed with utilization of the object-oriented Modelica language and the open-source OpenModelica environment. The results are compared with data obtained during a large scale integral test, simulating loss of coolant accident performed at Integral Test Stand Karlstein (INKA). The comparison shows a good agreement. Due to the modularity of models, both of them may be used in the future in systems incorporating condensation in horizontal or slightly inclined tubes. Depending on his preferences, the modeller may choose one-equation based approach or more sophisticated model composed of several exchangeable semi-empirical correlations.
Źródło:
Archives of Thermodynamics; 2017, 38, 4; 29--51
1231-0956
2083-6023
Pojawia się w:
Archives of Thermodynamics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Modeling of emergency condenser system response to loss of coolant accident in a BWR III+ generation
Modelowanie zachowania systemu kondensatora awaryjnego w przypadku awarii utraty chłodziwa w reaktorze BWR generacji III+
Autorzy:
Bryk, Rafał
Schmidt, Holger
Mull, Thomas
Powiązania:
https://bibliotekanauki.pl/articles/300663.pdf
Data publikacji:
2019
Wydawca:
Polska Akademia Nauk. Polskie Naukowo-Techniczne Towarzystwo Eksploatacyjne PAN
Tematy:
boiling water reactor
emergency condenser
LOCA
Modelica
reaktor wodny wrzący
kondensator awaryjny
awaria utraty chłodziwa
Opis:
Emergency Condenser (EC) is a heat exchanger composed of a large number of slightly inclined U-tubes arranged horizontally. The inlet header of the condenser is connected with the top part of the Reactor Pressure Vessel (RPV), which is occupied by steam during critical operation. The lower header in turn is linked with the RPV below the liquid water level during normal operation of the reactor. The tube bundle is filled with cold water and it is located in a vessel filled with water of the same temperature. Thus, the EC and RPV form together a system of communicating vessels. In case of an emergency and a decrease of the water level in the RPV, the water flows gravitationally from U-tubes to the RPV. At the same time the steam from the RPV enters to the EC and condenses due to its contact with cold walls of the EC. The condensate flows then back to the RPV due to the tubes inclination. Hence, the system removes heat from the RPV and serves as a high- and low-pressure injection system at the same time. In this paper a model of the EC system is presented. The model was developed with Modelica modeling language and OpenModelica environment which had not been used in this scope before. The model was verified against experimental data obtained during tests performed at INKA (Integral Test Facility Karlstein) ̶ a test facility dedicated for investigation of the passive safety systems performance of KERENA ̶ generation III+ BWR developed by Framatome.
Kondensator awaryjny jest wymiennikiem ciepła złożonym z dużej ilości U-rurek lekko nachylonych względem pozycji horyzontalnej. Kolektor wlotowy kondensatora połączony jest pojedynczym przewodem z górną częścią zbiornika ciśnieniowego reaktora, w której w trakcie normalnej pracy reaktora znajduje się para wodna. Dolny kolektor połączony jest natomiast ze zbiornikiem ciśnieniowym poniżej lustra wody w stanie ciekłym. Wiązka rurek kondensatora, w trakcie krytycznej pracy reaktora, wypełniona jest zimną wodą i zanurzona jest w basenie z wodą o tej samej temperaturze. Wiązka rurek kondensatora oraz rur doprowadzających tworzą wraz ze zbiornikiem ciśnieniowym zespół naczyń połączonych. W razie sytuacji awaryjnej, w przypadku spadku poziomu wody w zbiorniku ciśnieniowym, woda z kondensatora spływa grawitacyjnie do zbiornika ciśnieniowego, a para, która dostaje się do U-rurek kondensuje na skutek wymiany ciepła z zimną wodą otaczającą kondensator od zewnątrz. W ten sposób kondensator działając pasywnie, zastępuje wysokociśnieniowy oraz niskociśnieniowy wtrysk wody chłodzącej do zbiornika ciśnieniowego. W artykule przedstawiono model systemu kondensatora awaryjnego wraz ze zbiornikiem ciśnieniowym. Model został wykonany przy użyciu niestosowanego wcześniej w tym zakresie języka Modelica oraz środowiska OpenModelica. Następnie opracowany kod został zweryfikowany poprzez porównanie wyników z pomiarami eksperymentalnymi przeprowadzonymi na obiekcie INKA (Integral Test Facility Karlstein) – obiekcie testowym dedykowanym badaniom nad pasywnymi systemami bezpieczeństwa reaktora KERENA – reaktora BWR generacji III+ opracowanego przez firmę Framatome.
Źródło:
Eksploatacja i Niezawodność; 2019, 21, 3; 468-475
1507-2711
Pojawia się w:
Eksploatacja i Niezawodność
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Comparative analysis of energy potential of three ways of configuration of a condenser power plant thermal cycle
Autorzy:
Chmielniak, T.
Krzyślak, P.
Powiązania:
https://bibliotekanauki.pl/articles/258540.pdf
Data publikacji:
2008
Wydawca:
Politechnika Gdańska. Wydział Inżynierii Mechanicznej i Okrętownictwa
Tematy:
Comparative analysis of energy
condenser
power plant
thermal cycle
new regeneration
separation preheater
Opis:
A theoretical, comparative analysis of three configuration ways of a condenser power plant thermal cycle is shown in the work. A new regeneration & separation preheater and its application in a thermal cycle is presented. Results obtained allow to compare all three analysed configurations efficiencies.
Źródło:
Polish Maritime Research; 2008, 4; 30-36
1233-2585
Pojawia się w:
Polish Maritime Research
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Steam condensation analysis in a power plant condenser
Autorzy:
Drożyński, Z.
Powiązania:
https://bibliotekanauki.pl/articles/240848.pdf
Data publikacji:
2018
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
condensation
heat transfer
inert gases
power plant condenser
kondensacja
transport ciepła
gazy obojętne
skraplacz energetyczny
Opis:
Proposed is the analysis of steam condensation in the presence of inert gases in a power plant condenser. The presence of inert, noncondensable gases in a condenser is highly undesirable due to its negative effect on the efficiency of the entire cycle. In general, thermodynamics has not provided an explicit criterion for assessing the irreversible heat transfer process. The method presented here enables to evaluate precisely processes occurring in power plant condensers. This real process is of particular interest as it involves a number of thermal layers through which heat transfer is observed. The analysis was performed using a simple, known in the literature and well verified Berman’s model of steam condensation in the presence of non-condensable gases. Adapted to the geometry of the condenser, the model enables, for instance, to recognise places where non-condensable gases are concentrated. By describing with sufficient precision thermodynamic processes taking place in the vicinity of the heat transfer area segment, it is possible to determine the distributions of thermodynamic parameters on the boundaries between successive layers. The obtained results allow for the recognition of processes which contribute in varying degrees to irreversible energy degradation during steam condensation in various parts of the examined device.
Źródło:
Archives of Thermodynamics; 2018, 39, 4; 3-32
1231-0956
2083-6023
Pojawia się w:
Archives of Thermodynamics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The analyzis of the stream-air mixture during a flow through a tube bank inside a condenser
Autorzy:
Krzyślak, P.
Joachimiak, M.
Powiązania:
https://bibliotekanauki.pl/articles/175261.pdf
Data publikacji:
2014
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
condenser
pressure drop
steam-air mixture
water vapor condensation in a solution with air
partial pressure
Opis:
The paper presents the results of calculations related to the flow analysis of a tube bank taking into account the partial pressures of gases flowing through the condenser. Different mass share of the gas not condensing in the heat exchanger upstream to the first row of tubes and the partial pressures of water vapor and air have been taken into account. The value of the partial pressures of gases, pressures drop, temperature, velocity, Reynolds number, and air share in the subsequent rows of tubes have been calculated. This study is a basis for the analysis of heat exchange in the condenser considering the influence of the noncondensing gas. The increase in the share of air in the following rows of tubes results in an increase in the thermal resistance and condensation of increasingly lower mass of water vapor.
Źródło:
Transactions of the Institute of Fluid-Flow Machinery; 2014, 126; 131-140
0079-3205
Pojawia się w:
Transactions of the Institute of Fluid-Flow Machinery
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Advances in Digitization of Microphones and Loudspeakers
Autorzy:
Kulka, Z.
Powiązania:
https://bibliotekanauki.pl/articles/177402.pdf
Data publikacji:
2011
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
electret condenser microphone
digital microphone
CMOS-MEMS digital microphone
digital microphone array
sigma-delta ADC/DAC
digital loudspeaker
CMOS-MEMS digital loudspeaker
digital loudspeaker array
Opis:
The development of digital microphones and loudspeakers adds new and interesting possibilities of their applications in different fields, extended from industrial, medical to consumer audio markets. One of the rapidly growing field of applications is mobile multimedia, such as mobile phones, digital cameras, laptop and desktop PCs, etc. The advances have also been made in digital audio, particularly in direct digital transduction, so it is now possible to create the all-digital audio recording and reproduction chains potentially having several advantages over existing analog systems.
Źródło:
Archives of Acoustics; 2011, 36, 2; 419-436
0137-5075
Pojawia się w:
Archives of Acoustics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Entropy generation in a condenser and related correlations
Autorzy:
Laskowski, R.
Jaworski, M.
Smyk, A.
Powiązania:
https://bibliotekanauki.pl/articles/240683.pdf
Data publikacji:
2015
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
steam condenser
entropy generation
kondensator pary
generowanie entropii
Opis:
The paper presents an analysis of relations describing entropy generation in a condenser of a steam unit. Connections between entropy generation, condenser ratio, and heat exchanger effectiveness, as well as relations implied by them are shown. Theoretical considerations allowed to determine limits of individual parameters which describe the condenser operation. Various relations for average temperature of the cold fluid were compared. All the proposed relations were verified against data obtained using a simulator and actual measurement data from a 200 MW unit condenser. Based on data from a simulator it was examined how the sum of entropy rates, steam condenser effectiveness, terminal temperature difference and condenser ratio vary with the change in the inlet cooling water temperature, mass flow rate of steam and the cooling water mass flow rate.
Źródło:
Archives of Thermodynamics; 2015, 36, 2; 27-48
1231-0956
2083-6023
Pojawia się w:
Archives of Thermodynamics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Estimation of a tube diameter in a ‘church window’ condenser based on entropy generation minimization
Autorzy:
Laskowski, R.
Rusowicz, A.
Grzebielec, A.
Powiązania:
https://bibliotekanauki.pl/articles/240523.pdf
Data publikacji:
2015
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
entropy generation minimization
power plant condenser
tube diameter
minimalizacja entropii generacji
skraplacz energetyczny
średnica rurek
Opis:
The internal diameter of a tube in a ‘church window’ condenser was estimated using an entropy generation minimization approach. The adopted model took into account the entropy generation due to heat transfer and flow resistance from the cooling-water side. Calculations were performed considering two equations for the flow resistance coefficient for four different roughness values of a condenser tube. Following the analysis, the internal diameter of the tube was obtained in the range of 17.5 mm to 20 mm (the current internal diameter of the condenser tube is 22 mm). The calculated diameter depends on and is positively related to the roughness assumed in the model.
Źródło:
Archives of Thermodynamics; 2015, 36, 3; 49-59
1231-0956
2083-6023
Pojawia się w:
Archives of Thermodynamics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Ocena konstrukcji skraplacza na podstawie minimum strumienia generacji entropii
The condenser design assessment on the basis of the minimum entropy generation
Autorzy:
Laskowski, R.
Rusowicz, A.
Grzebielec, A.
Jaworski, M.
Powiązania:
https://bibliotekanauki.pl/articles/271317.pdf
Data publikacji:
2016
Wydawca:
Centralny Ośrodek Badawczo-Rozwojowy Aparatury Badawczej i Dydaktycznej, COBRABiD
Tematy:
skraplacz
minimum generacji strumienia entropii
ocena konstrukcji skraplacza
condenser
minimum entropy generation
condenser design assessment
Opis:
W skraplaczach energetycznych generowane są jedne z największych strat strumienia entropii w instalacji energetycznej. Celowe jest obniżanie tej straty, aby uzyskać poprawę całkowitej sprawności instalacji. W artykule podano warunek dla minimum generacji strumienia entropii, z którego wynika, że minimum to jest osiągnięte, gdy podgrzew wody w rurkach skraplacza ma równomierny rozkład (przyjmuje taką samą wartość dla wszystkich rurek). Poprawność tego warunku sprawdzono na podstawie danych uzyskanych z symulatora 2D skraplacza dla jednego z krajowych bloków o mocy 50 MW. Na podstawie otrzymanych z symulatora przyrostów temperatur oraz odpowiadających im ciśnień pary dla 30 rurek dokonano oceny poprawności konstrukcji skraplacza.
The losses in power plants condensers are some of the biggest losses in the entropy generation in whole power plant system. It is advisable to decrease the loss for improving the overall efficiency of the system. The article presents the condition for the minimum entropy generation, which states that the minimum is achieved when the heating of the water in the tubes of the condenser has a uniform distribution (takes the same value for all tubes). The correctness of this condition was verified on the basis of data obtained from the 2D condenser simulator for one of the national units with a 50 MW electric capacity. On the basis of the simulator increases temperatures and steam pressures corresponding to 30 tubes assesses the correctness of the construction of the condenser.
Źródło:
Aparatura Badawcza i Dydaktyczna; 2016, 21, 2; 76-84
2392-1765
Pojawia się w:
Aparatura Badawcza i Dydaktyczna
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Determining steam condensation pressure in a power plant condenser in off-design conditions
Autorzy:
Laskowski, Rafał
Smyk, Adam
Ruciński, Adam
Szymczyk, Jacek
Powiązania:
https://bibliotekanauki.pl/articles/1954999.pdf
Data publikacji:
2021
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
thermal power plant
steam condenser
condenser model
steam condensation
pressure
reference parameters
steam condenser effectiveness
Opis:
The paper presents formulas which can be used to determine steam condensation pressure in a power plant condenser in off-design conditions. The mathematical model provided in the paper makes it possible to calculate the performance of the condenser in terms of condensing steam pressure, cooling water temperature at the condenser outlet, and condenser effectiveness under variable load conditions as a function of three input properties: the temperature and the mass flow rate of cooling water at the condenser inlet and the mass flow rate of steam. The mathematical model takes into account values of properties occurring in reference conditions but it contains no constant coefficients which would have to be established based on data from technical specifications of a condenser or measurement data. Since there are no such constant coefficients, the model of the steam condenser proposed in the paper is universally applicable. The proposed equations were checked against warranty measurements made in the condenser and measurement data gathered during the operation of a 200 MW steam power unit. Based on the analysis, a conclusion may be drawn that the proposed means of determining pressure in a condenser in off-design conditions reflects the condenser performance with sufficient accuracy. This model can be used in optimization and diagnostic analyses of the performance of a power generation unit.
Źródło:
Archives of Thermodynamics; 2021, 42, 3; 45-62
1231-0956
2083-6023
Pojawia się w:
Archives of Thermodynamics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Adaptive reliability structures of heat exchange surface in turbine condenser
Adaptacyjne struktury niezawodnościowe powierzchni wymiany ciepła skraplacza turbiny parowej
Autorzy:
Łukaszewski, K.
Powiązania:
https://bibliotekanauki.pl/articles/1365369.pdf
Data publikacji:
2018
Wydawca:
Polska Akademia Nauk. Polskie Naukowo-Techniczne Towarzystwo Eksploatacyjne PAN
Tematy:
adaptive reliability structure
reliability
turbine condenser
designing of heat exchangers
exploitation of heat exchangers
adaptacyjna struktura niezawodnościowa
niezawodność
skraplacz turbiny parowej
projektowanie wymienników ciepła
eksploatacja wymienników ciepła
Opis:
In this paper adaptive reliability structures of heat exchange surface in turbine condenser was proved from the angle of effective heat exchange in variable conditions of its exploitation. Then, determinant factors for design and exploitation in assessment of reliability of pipe subsystem in turbine condenser were suggested. The influence of change of scheme of the pipes, constituting the surface of heat exchange, which stems from the matter of regulating the surface in an attempt to both condense the given amount of steam and maintain the given pressure in the condenser in variable conditions of its exploitation on the reliability of the pipe subsystem was determined. The surface of heat exchange is regulated by enabling and disabling the flow of cooling water through given amount of pipes, in a given way, that is by enabling or disabling possible combination of given pipes in given exploitation conditions. An algorithm to assess the reliability of the pipe subsystem in the condenser in given exploitation conditions, means of regulating the surface and up-to-date technical condition was put forward. The reliability of pipe subsystem has a significant influence either on reliability of the condenser while exploited or in the further course, indirectly on sustaining the requested reliability in the power system therein. Effective operation of the condenser in technical power system is performed by sustaining the given pressure of steam condensation, which is vital in maintaining the required energy efficiency of technical power system in variable exploitation conditions. The exemplification of the aspects put forward in the paper pertains to steam turbine condensers.
W artykule wykazano adaptację struktur niezawodnościowych powierzchni wymiany ciepła skraplacza turbiny parowej z punktu widzenia efektywnej wymiany ciepła w zmiennych warunkach jego eksploatacji. Następnie, wskazano istotne uwarunkowania projektowo-eksploatacyjne oszacowania niezawodności podsystemu rur skraplacza turbiny parowej. Wykazano wpływ zmian układów rur stanowiących powierzchnię wymiany ciepła, które wynikają ze sposobu regulacji tej powierzchni w celu skroplenia zadanej ilości pary wodnej i utrzymywania zadanej wartości ciśnienia w skraplaczu w zmiennych warunkach jego eksploatacji, na niezawodność podsystemu rur. Powierzchnię wymiany ciepła reguluje się poprzez włączanie i wyłączanie przepływu wody chłodzącej przez zadaną liczbę rur, w określony sposób tzn. poprzez włączanie albo wyłączanie możliwych kombinacji określonych układów rur w zadanych warunkach eksploatacyjnych. Przedstawiono algorytm oszacowania niezawodności podsystemu rur skraplacza względem określonych warunków eksploatacyjnych, sposobu regulacji tej powierzchni i aktualnego stanu technicznego. Niezawodność podsystemu rur ma istotny wpływ na niezawodność skraplacza turbiny parowej w czasie jego eksploatacji, a dalej pośrednio na utrzymywanie wymaganej niezawodności systemu energetycznego, w którym występuje. Efektywne funkcjonowanie skraplacza w technicznym systemie energetycznym jest realizowane poprzez utrzymywanie zadanego stałego ciśnienia skraplania pary wodnej, co jest istotne z punktu widzenia utrzymywania wymaganej sprawności energetycznej technicznego systemu energetycznego w różnych warunkach eksploatacyjnych. Egzemplifikacja zawartych w pracy zagadnień odnosi się do rurowych skraplaczy turbin parowych.
Źródło:
Eksploatacja i Niezawodność; 2018, 20, 1; 153-159
1507-2711
Pojawia się w:
Eksploatacja i Niezawodność
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies