Tytuł:
A Comparative Structural Analysis of Four Radiosonde Models
Porównawcza analiza strukturalna czterech modeli radiosond
Autorzy:
Hegyi, Norbert
Jósvai, János
Powiązania:
https://bibliotekanauki.pl/articles/36450313.pdf
Data publikacji:
2021
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Lotnictwa
Tematy:
radiosonde
unmanned free balloon
computed tomography measurement
collision test
radiosonda
balon wolny bezzałogowy
tomografia komputerowa
test zderzeniowy
Opis:
In this study, we first performed a comprehensive structural analysis of four models of radiosondes (devices intended for use as the meteorological probe of a sounding balloon) manufactured by three different companies - Graw, Vaisala and Meteomodem. The radiosondes were disassembled for visual inspection and manual measurement, three-dimensional computed tomography images were taken of their inner structure, and the outer shapes of the radiosondes were scanned with a structured-light three-dimensional scanner. The structural properties of the radiosondes thus identified were then compared to one other, based on which the Meteomodem M10 was ranked as the least harmful in a potential collision. Next, the Meteomodem M10 radiosonde was used in collision tests with a heavy target and with a pumpkin model, in order to evaluate the possible damage caused by and to the radiosonde in different types of collisions.
W pracy przeprowadzono kompleksową analizę strukturalną czterech modeli radiosond (urządzeń stosowanych przy balonach meteorologicznych) produkowanych przez trzy różne firmy: Graw, Vaisala i Meteomodem. Radiosondy rozłożono na części w celu dokonania oględzin i pomiarów ręcznych, wykonano trójwymiarowe zdjęcia tomograficzne ich wewnętrznej struktury oraz zeskanowano ich zewnętrzne kształty za pomocą trójwymiarowego skanera. Po porównaniu właściwości strukturalnych radiosond, model Meteomodem M10 został uznany za najmniej szkodliwy w potencjalnym zderzeniu z przeszkodą. Następnie przeprowadzono testy zderzeniowe radiosondy Meteomodem M10 z przeszkodą twardą oraz miękką w celu oceny możliwych uszkodzeń w różnych typach kolizji.
Źródło:
Transactions on Aerospace Research; 2021, 4 (265); 68-81
0509-6669
2545-2835
Pojawia się w:
Transactions on Aerospace Research
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Ocena dokładności odwzorowania kształtu powierzchni nieregularnych w tomografii komputerowej
Accuracy assessment of irregular surface shape mapping in computed tomography
Autorzy:
Ryniewicz, A.
Powiązania:
https://bibliotekanauki.pl/articles/156375.pdf
Data publikacji:
2012
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
tomografia komputerowa
powierzchnia
odwzorowanie kształtu
dokładność
wzorzec
computed tomography
surface
shape mapping
accuracy
measurement master
Opis:
W referacie przedstawiono wybrane aspekty dotyczące dokładności odwzorowania kształtu powierzchni nieregularnych w tomografii komputerowej TK. Zaproponowano wzorzec do badań, którego powierzchnię stanowi paraboloida eliptyczna. Kształt dobrano z uwagi na specyfikę tworzenia modeli przestrzennych w TK, bazującą głównie na kompilacji otrzymanych skanów w przyjętej skali szarości wg Hounsfielda. W pracy przedstawiono wyniki badań opracowanego wzorca na tomografie komputerowym oraz ocenę dokładności odwzorowania kształtu, przeprowadzoną metodą best fit, wynikającą z wykorzystywanych do tworzenia modeli wirtualnych oprogramowań.
Developing the correct opinion on a technical device, process technology and especially the issue of proper medical diagnosis is associated with the assessment or determination of the changes of parameters describing the analysed syndrom or desease (Fig. 1). In recent years, to evaluate the geometric parameters and internal structures of medical and technical tasks, the computed tomography (CT) has been used. Use of the CT as a system or metrological device cannot be made without estimating the accuracy of measurements realized with its use. Therefore the paper presents some aspects of the accuracy of shape mapping of irregular surfaces in computed tomography. The surface was described as an irregular surface characterised by an alternating angle relative to the plane of the measuring system determined by the CT gantry. The standard being examined is the surface of an elliptic paraboloid shape (Figs. 2, 3). The shape was chosen because of the specificity of spatial modeling in the CT, which is based mainly on compilation of the obtained scans in grayscale defined by Hounsfield. For a pattern established in this way, the scans represent parabolas or ellipses, depending on the scanning plane position determined by the gantry. The paper presents the measurement results of the standard developed by a computed tomography and assessment of the shape mapping accuracy carried out by the best fit method, which was implemented with use of software that was used to create virtual models (Figs. 5-7).
Źródło:
Pomiary Automatyka Kontrola; 2012, R. 58, nr 1, 1; 109-111
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Pomiary powierzchni stawowych z wykorzystaniem metody współrzędnościowej i obrazowania tomograficznego
Measurements of articular surfaces using the method of coordinate and computed tomography
Autorzy:
Ryniewicz, A.
Ryniewicz, A. M.
Bojko, A.
Powiązania:
https://bibliotekanauki.pl/articles/154166.pdf
Data publikacji:
2013
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
powierzchnie stawowe
pomiary
odwzorowanie kształtu
tomografia komputerowa
współrzędnościowa technika pomiarowa
articular surface
measurement
mapping the shape
computed tomography
coordinate measuring technology
Opis:
Celem opracowania była ocena niedokładności odwzorowania kształtu powierzchni stawowych stawu kolanowego w rekonstrukcjach wyznaczonych na podstawie obrazowania tomografią komputerową (CT). Ocena dokładności odwzorowania kształtu powierzchni stawowych polegała na porównaniu modeli numerycznych otrzymanych z CT z modelami referencyjnymi. W ocenie dokładności odwzorowania w CT stwierdzono, że w 80% odchyłki niedopasowania nie przekraczały ±0,5mm. Wartości maksymalne do ±1mm wystąpiły w strefach największych pochyleń i wypukłości: na zboczu dołu międzykłykciowego oraz w połowie wysokości kłykci kości udowej.
The aim of the paper is to assess the inaccuracy of mapping the shape of articular surfaces of a knee joint in 3D reconstructions based on CT imaging, and related to measurements based on coordinate tests. The test material were further ends of the femur with normal articular surfaces of the medial and lateral condyle. The material came from cadaver specimens. The models were subjected to CT imaging and tested on WMP. CT was performed in the Laboratory of Diagnostic Imaging Hospital of John Paul II on 64 layered tomography. The reference coordinate test was performed in the Coordinate Metrology Laboratory of the Cracow University of Technology on a machine Leitz PMM 12106. Assessment of the accuracy of mapping the shape of the articular surface of the medial and lateral condyles of the femur distal end consisted in comparison of spatial models using the best fit. The results are presented in the form of a map of deviations of the shape mapping accuracy. In the assessment of the CT mapping accuracy it was found that 80% of the mismatch deviation did not exceed ±0.5 mm. The maximum values for ±1 mm occurred in the zones of the greatest inclination and bulge: the slope of the intercondylar bottom, between the medial and lateral condyles, and in the middle of the femoral condyles on their outer surfaces, where there are strong highlights.
Źródło:
Pomiary Automatyka Kontrola; 2013, R. 59, nr 3, 3; 220-222
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-3 z 3

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies