Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "computed tomography (CT)" wg kryterium: Temat


Tytuł:
Blood flow in cerebral arteries – automated way from Computed Tomography to ANSYS Fluent
Autorzy:
Bodys, J.
Poraj, J.
Kryś, M.
Powiązania:
https://bibliotekanauki.pl/articles/132130.pdf
Data publikacji:
2015
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
Computational Fluid Dynamics
CFD
blood flow
meshing
Computed Tomography Scan
CT scan
Opis:
With the constant growth of computer simulation significance in science and engineering, many new fields are gaining access to these powerful tools. One of these new disciplines is medicine. Human body provides many fascinating areas that could be researched from completely different angle and could gain all the benefits that computer simulation offers. For example blood flow in human arteries can be studied using Computational Fluid Dynamics. Researchers of cerebrovascular disorders can get an insight view on physical phenomena of blood flow and study risk factors of embolism or cerebral aneurysm. Main issue in using computer simulation in medical research is the complexity and uniqueness of geometry that needs to be handled. After all, human body is one of the most sophisticated engineering systems created by nature. In this paper, a workflow for creating a numerical mesh for CFD simulation purposes is shown. Application shown in the example focus on cerebral arteries blood flow simulation. Numerical mesh is generated based on CT scan of patient’s head, using freeware tools Slicer3D and AutoIt3 as well as commercial software ANSYS Fluent Meshing 15.0.
Źródło:
Advanced Technologies in Mechanics; 2015, 2, no. 1 (2); 9-14
2392-0327
Pojawia się w:
Advanced Technologies in Mechanics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Możliwości zastosowania metody tomografii komputerowej (CT) w lotnictwie
Possible application of X-ray computed tomography (CT) in aviation
Autorzy:
Chalimoniuk, M.
Kułaszka, A.
Powiązania:
https://bibliotekanauki.pl/articles/107902.pdf
Data publikacji:
2018
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
NDT
tomografia komputerowa CT
lotnictwo
computed tomography CT
aviation
Opis:
W artykule omówione zostały możliwości zastosowania metody CT w lotnictwie. Nowoczesna nieniszcząca metoda diagnostyczna, jaką jest tomografia komputerowa, pozwala na badania praktycznie wszystkich materiałów stosowanych w szeroko rozumianej branży lotniczej - od stopów chromowo - niklowych stosowanych do produkcji łopatek turbinowych, poprzez materiały kompozytowe, aż do nawierzchni lotniskowych. Metoda ta pozwala także na badania całych agregatów, bez konieczności ich demontażu np. podczas badań komisyjnych zdarzeń lotniczych. W artykule pokazano możliwości i ograniczenia zastosowania badań metodą CT na konkretnych przykładach detali lotniczych.
The article describes the possibilities of the application of the CT method in aviation. The modern non-destructive diagnostic method, which is the computer tomography, enables to examine all materials applied in the widely understood aviation industry. From chromium-nickel alloys used to manufacture turbine blades, through composite materials, to runway pavements. This method enables to test all aggregates, without the necessity to dismantle them e.g. during commission tests of aircraft incidents. The article showed the possibilities and limitations of conducting tests with the CT method in particular examples of aircraft details.
Źródło:
Badania Nieniszczące i Diagnostyka; 2018, 3; 72-75
2451-4462
2543-7755
Pojawia się w:
Badania Nieniszczące i Diagnostyka
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The defect analysis of Inconel 738LC with computed tomography inspection
Autorzy:
Ciećko, Andrzej
Kamiński, Łukasz
Wierzba, Patrycja
Powiązania:
https://bibliotekanauki.pl/articles/175802.pdf
Data publikacji:
2020
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
computed tomography
CT
material defects
Inconel 738LC
tensile test
chemical analysis
material properties
nondestructive
Inconel
Opis:
In the present paper, computed tomography (CT) inspection is shown. The CT inspection method allowed to rate the density of defects hidden inside a material, which has a significant role in the live material. The method allows to evaluate the reliability of tensile test’s results. In our analysis, the position of crack propagation was determined by CT, and the tensile test was performed to check the accuracy of the nondestructive method. The tensile tests were performed on Inconel 738LC [1] samples.
Źródło:
Advances in Manufacturing Science and Technology; 2020, 44, 3; 80-83
0137-4478
Pojawia się w:
Advances in Manufacturing Science and Technology
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Pomiary dwuenergetycznej tomografii (Dual Energy CT) w celu badania skał
Calibration of dual energy CT scans for rock core examination
Autorzy:
Dohnalik, Marek
Kaczmarczyk, Jan
Powiązania:
https://bibliotekanauki.pl/articles/1834984.pdf
Data publikacji:
2019
Wydawca:
Instytut Nafty i Gazu - Państwowy Instytut Badawczy
Tematy:
tomografia komputerowa
Dual Energy CT
DECT
dwuenergetyczna tomografia
computed tomography
dual energy CT
dual energy computed tomography
Opis:
: Jedno z pierwszych zastosowań rentgenowskiej tomografii komputerowej w geologii miało miejsce w 1974 roku. Tomografia rentgenowska (CT) umożliwia nieinwazyjne obrazowanie badanych przedmiotów. Wynikiem pomiaru tomograficznego jest przestrzenny obraz, przedstawiający zmiany absorpcji promieniowania rentgenowskiego. Powstaje on poprzez wyliczenie, podczas procesu rekonstrukcji, wartości absorpcji dla każdego punktu badanego przedmiotu. Istotną zaletą tomografów komputerowych jest możliwość przebadania dużych obiektów (metrowych odcinków rdzenia) w bardzo krótkim czasie. Ich wadą jest natomiast względnie niska rozdzielczość pomiaru. Każdy woksel na obrazie tomograficznym ma przypisaną konkretną wartość zaczernienia proporcjonalną do liniowego współczynnika tłumienia, zależną od gęstości elektronowej i efektywnej liczby atomowej, uśrednionych w obrazowanej przestrzeni (zakres uśredniania określa rozdzielczość obrazu tomograficznego). Dysponując dwoma obrazami, zarejestrowanymi przy dwóch różnych energiach pomiaru, można podjąć próbę rozdziału obrazu na dwie składowe: pierwszą – zależną od gęstości elektronowej i drugą – zależną od efektywnej liczby atomowej. Celem opisanych prac jest pokazanie możliwości wykorzystania dwuenergetycznej tomografii komputerowej (DECT) do charakterystyki litologiczno-gęstościowej rdzeni wiertniczych. Aby wykorzystać obrazy tomograficzne do otrzymania wymienionych wielkości fizykochemicznych konieczna jest standaryzacja obrazów. W pracy przedstawiono proces wyznaczania współczynników kalibracyjnych, które są niezbędne do przeliczania wartości współczynników absorpcji, będących bezpośrednim wynikiem rekonstrukcji pomiaru tomograficznego na wartości gęstości elektronowej oraz efektywnej liczby atomowej Z. W artykule zaprezentowano proces kalibracji z wykorzystaniem wzorcowych minerałów. Wyliczone z analizy obrazów wartości próbek wzorcowych, porównano z wartościami wyznaczonymi metodami laboratoryjnymi. Przykład zastosowania wyników przedstawiono na przebadanym fragmencie obrazu rdzenia piaskowca, zawierającego szczelinę wypełniona kalcytem.
One of the first applications of X-ray computed tomography in geology took place in 1974. X-ray tomography (CT) allows non-invasive imaging of the examined objects. The result of a tomographic measurement is a spatial image, showing the changes in X-ray absorption value for each point of the examined object, which are a result of calculations during the reconstruction process. An important advantage of computer tomographs is the ability to test large objects (meter sections of the core) in a very short time, while the disadvantage is the relatively low resolution of the measurement. Each voxel in the tomographic image has a specific grey value, proportional to the linear attenuation coefficient, depending on the electron density and the effective atomic number averaged in the imaged space (the averaging range is determined by the resolution of the tomographic image). Two tomographic images registered at two different energies, allows the deconvolution of the images into two components: the first – dependent on the electron density and the second – dependent on the effective atomic number. The aim of this study is to show the possibility of using dual energy computed tomography (DECT) to litho-density characterization of rock cores. In order to use tomographic images to obtain the above-mentioned physicochemical values, it is necessary to standardize CT images. The paper presents the process of determining calibration coefficients, which are necessary to convert the values of absorption coefficients, which are a direct result of CT reconstruction, into density values and effective Z atomic number. The article presents the calibration process with the use of reference rock fragments. The values of the standard samples computed from the analysis of images were compared with the values determined by laboratory methods. An example of the application of results is presented on the examined part of the image of the sandstone core, containing a calcite-filled fracture.
Źródło:
Nafta-Gaz; 2019, 75, 2; 83-88
0867-8871
Pojawia się w:
Nafta-Gaz
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Texture analysis as a tool for medical decision support. P. 2 Classification of liver disorders based on computed tomography images
Analiza tekstur jako narzędzie wspomagania decyzji medycznych. Cz. 2 Klasyfikacja patologii wątroby na obrazach tomografii komputerowej
Autorzy:
Duda, D.
Powiązania:
https://bibliotekanauki.pl/articles/88386.pdf
Data publikacji:
2014
Wydawca:
Politechnika Białostocka. Oficyna Wydawnicza Politechniki Białostockiej
Tematy:
obrazowanie medyczne
analiza obrazów
tekstura
selekcja cech
diagnoza
wątroba
tomografia komputerowa
wspomaganie decyzji medycznych
medical imaging
image analysis
texture
feature selection
computer aided diagnosis
CAD
medical decision support
liver
computed tomography
CT
Opis:
Texture analysis has already demonstrated its great potential in many digital image-based diagnostic systems. It allows to extract from an image many important diagnostic information, impossible to capture with only the visual appreciation. The first attempts to use a texture analysis (TA) as a tool for characterization of an image content took place in the 70’s of the last century. Since then a variety of methods have been proposed and found their application in many domains, also – in the medical field. However, it is still difficult to indicate a method that would ensure satisfactory results for any diagnostic problem. The present work gives an overview of the texture analysis methods, that have been applied for hepatic tissue characterization from Computed Tomography (CT) images. It includes details of about forty studies, presented over the past two decades, devoted to (semi)automatic detection or/and classification of different liver pathologies. Quoted systems are divided into three categories: (i) based on a single-image texture of non-enhanced CT images of the liver, (ii) based on a single-image texture of contrast-enhanced images, and (iii) based on a multiimage texture. The latter ones concern a simultaneous analysis of sets of textures, each of which corresponds to the same liver slice, but is related to a different contrast agent concentration in hepatic vessels.
Analiza tekstur jest szeroko stosowana w wielu cyfrowych systemach wspomagania decyzji medycznych, na podstawie danych obrazowych. Pozwala ona wydobyć z obrazu istotne szczegóły, których nie można dostrzec podczas analizy wizualnej. Pierwsze próby analizy tekstur miały miejsce w latach siedemdziesiątych ubiegłego wieku. Od tamtej pory zaproponowano wiele metod analizy tekstur. Trudno jest jednak wskazać metodę uniwersalna, która zapewniłaby zadowalające wyniki dla każdego problemu diagnostycznego. Niniejsza praca stanowi przegląd metod analizy tekstur, stosowanych do opisu tkanki wątrobowej na obrazach tomografii komputerowej. Przedstawia informacje o około czterdziestu systemach diagnostycznych, zaproponowanych w ciągu ostatnich dwóch dekad, poświęconych (pół)automatycznemu wykrywaniu lub / i klasyfikacji schorzeń wątroby. Opisywane systemy zostały podzielone na trzy kategorie: (i) opierające się na teksturze pojedynczego obrazu, pozyskanego bez podawania pacjentowi środka kontrastującego, (ii) opierające się ´na teksturze pojedynczego obrazu, pozyskanego po podaniu pacjentowi środka kontrastującego, oraz (iii) opierające się na jednoczesnej analizie wielu tekstur. Te ostatnie odnoszą się do analizy zestawów tekstur przedstawiających ten sam wycinek wątroby, lecz odpowiadających różnym stężeniom środka kontrastowego w jej naczyniach krwionośnych.
Źródło:
Advances in Computer Science Research; 2014, 11; 85-108
2300-715X
Pojawia się w:
Advances in Computer Science Research
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Automatic Extraction of the Pelvicalyceal System for Preoperative Planning of Minimally Invasive Procedures
Autorzy:
Heryan, K.
Skalski, A.
Jakubowski, J.
Drewniak, T.
Gajda, J.
Powiązania:
https://bibliotekanauki.pl/articles/220364.pdf
Data publikacji:
2017
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
pelvicalyceal system segmentation
kidney segmentation
kidney compartments
Computed Tomography (CT)
kidney cancer
Opis:
Minimally invasive procedures for the kidney tumour removal require a 3D visualization of topological relations between kidney, cancer, the pelvicalyceal system and the renal vascular tree. In this paper, a novel methodology of the pelvicalyceal system segmentation is presented. It consists of four following steps: ROI designation, automatic threshold calculation for binarization (approximation of the histogram image data with three exponential functions), automatic extraction of the pelvicalyceal system parts and segmentation by the Locally Adaptive Region Growing algorithm. The proposed method was applied successfully on the Computed Tomography database consisting of 48 kidneys both healthy and cancer affected. The quantitative evaluation (comparison to manual segmentation) and visual assessment proved its effectiveness. The Dice Coefficient of Similarity is equal to 0.871 ± 0.060 and the average Hausdorff distance 0.46 ± 0.36 mm. Additionally, to provide a reliable assessment of the proposed method, it was compared with three other methods. The proposed method is robust regardless of the image acquisition mode, spatial resolution and range of image values. The same framework may be applied to further medical applications beyond preoperative planning for partial nephrectomy enabling to visually assess and to measure the pelvicalyceal system by medical doctors.
Źródło:
Metrology and Measurement Systems; 2017, 24, 1; 3-18
0860-8229
Pojawia się w:
Metrology and Measurement Systems
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Healed or non-healed? Computed tomography (CT) visualisation of morphology of bite trace ichnotaxa on a dinosaur bone
Autorzy:
Jacobsen, A. R.
Lauridsen, H.
Fiirgaard, B.
Boel, L. W. T.
Hansen, K.
Powiązania:
https://bibliotekanauki.pl/articles/191178.pdf
Data publikacji:
2015
Wydawca:
Polskie Towarzystwo Geologiczne
Tematy:
Bite traces
dinosaur bone
theropod
CT
computed tomography
stereomicroscopy
Opis:
Bite traces on fossilised bones can provide important information on predator-prey relations and interactions in ancient environments. In 2009, two new ichnotaxa, Linichnus serratus and Knethichnus parallelum, were introduced to develop the application of bite traces as an ichnological tool. Ichnotaxa defined by theropod bite traces can provide useful information for understanding feeding behaviour. However, objective interpretation of possible bite traces can be difficult using traditional visual inspection. In this study, the bite traces on a fossilised dinosaur bone were comprehensively examined by correlating traditional naked-eye in spection with computed tomography (CT) imaging, used to visualise the internal morphology of the bite traces and in particular, to clarify the appearance of one possibly healed bite trace. A forensic pathologist visually examined the bone with the aid of stereomicroscopy and a radiologist analysed the CT scans. Sixteen different scanner settings were used to optimise the CT parameters and avoid signal at tenuation, in the form of hypointense artefacts in the central trabeculated part of the bone fragment. The use of CT scanning provided information on internal morphology from the vicinity of the bite trace, including hyperdense zones, not identified using visual inspection alone. By applying the extended CT scale, the dense and radiopaque cortical bone layer could be clearly identified and applied as a pathomorphological marker to correctly distinguish non-healed from healed wounds. In conclusion, the authors demonstrate that external visual examination of trace fossils by ichnologists in combination with interior examination using CT imaging can be applied to characterise ichnotaxa defined by bite traces and potentially provide clues on ancient feeding behaviour.
Źródło:
Annales Societatis Geologorum Poloniae; 2015, 85, 3; 457-464
0208-9068
Pojawia się w:
Annales Societatis Geologorum Poloniae
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Validation of microscopy measured porosity in carbon fibbers composites
Autorzy:
Jędral, Arnold
Bona, Anna
Powiązania:
https://bibliotekanauki.pl/articles/244963.pdf
Data publikacji:
2019
Wydawca:
Instytut Techniczny Wojsk Lotniczych
Tematy:
porosity
carbon fibre
microscope
UT
Ultrasonic test
CT
computed tomography
Opis:
One of the most common defects in carbon fibrereinforced plastics (CFRP) is porosity. Too much of those defectscould be serious problemsto mechanical properties, which directly take effect on elements safety, like aircrafts. Therefore, the evaluation of porosity is very important test. Microscopic observations are widely used as a quality instrument in materials and constructions inspections. Cross section image of a material is easy to prepare and analyse. Porosity of a carbon fibrereinforced plasticcan be clearly spot in such kind of images. Study shows that in the most cases porosity appear between layers of fibres , rather between fibres. Unfortunately,image from microscope is only 2D picture from a small representative region. Because of that,comparison of 2D image to a real porosity distribution in all volume of a material is very difficult. To verify 2D microscopic observation method is necessary to perform another kind of tests. In this article , authors focused on non-destructive (NDT) and destructive testing methods. 2D porosity images from light microscope were compared with three different testing methods: ultrasonic test (UT), computed tomography (CT) test and constituent content of composite materials standard test method according to ASTM D3171 – 15, procedure B. Porosity results obtained from dissolution of resin from the carbon-epoxy resin sample.
Źródło:
Journal of KONES; 2019, 26, 4; 83-90
1231-4005
2354-0133
Pojawia się w:
Journal of KONES
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Tomograficzna ocena jakości odlewów ze stopu Haynes 282
Quality check of H282 castings by Computed Tomography (CT) technique
Autorzy:
Krzak, I.
Tchórz, A.
Pirowski, Z.
Jaśkowiec, K.
Grudzień, M.
Purgert, R.
Powiązania:
https://bibliotekanauki.pl/articles/391747.pdf
Data publikacji:
2018
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Odlewnictwa
Tematy:
rentgenowska tomografia komputerowa (CT)
nieciągłości strukturalne
nadstopy niklu
Haynes 282
X-ray computed tomography (CT)
structural discontinuity
nickel superalloys
Opis:
W ramach prac projektu międzynarodowego realizowanego w Instytucie Odlewnictwa w Krakowie we współpracy z Energy Industries of Ohio opracowano technologię topienia w otwartym piecu indukcyjnym i grawitacyjnego odlewania nadstopów niklu. Dotychczas nadstopy te stosowane były wyłącznie jako przerabiane plastycznie. Do kontroli jakości wykonanych odlewów ze stopu Haynes 282 (H282) zastosowano między innymi rentgenowską tomografię komputerową (ang. Computed Tomography, CT). Jest to metoda nieniszcząca, która łączy badania rentgenowskie z zaawansowaną technologią komputerową. W niniejszej pracy zaprezentowano wybrane przykłady uzyskanych wyników badań zrealizowanych za pomocą rentgenowskiego tomografu komputerowego firmy GE Phoenix typu v/tome/x l-450 będącego na wyposażeniu Instytutu Odlewnictwa. Wszystkie operacje związane z obróbką danych z CT były wykonywane za pomocą oprogramowania datos/x - reconstruction i VGStudio Max 2.0.
As a part of the international project carried out at the Foundry Research Institute in Krakow in cooperation with Energy Industries of Ohio, anopen induction furnace melting technology and gravity casting of nickel superalloys have been developed. These alloys have been processed plastically so far. Quality control of Haynes 282 alloy (H282), was made with X-ray computed tomography (CT). CT is a non-destructive method that combines X-ray examinations with advanced computer technology. Selected results of the research obtained from the X-ray computer tomograph have been presented in the paper. Research were made by using the GE Phoenix v/ tome/x l-450 tompgraph type belonging to the Foundry Research Institute equipment. All operations related to the processing of CT data were performed using the datos/x-reconstruction and VGStudio Max 2.0 software.
Źródło:
Prace Instytutu Odlewnictwa; 2018, 58, 4; 219-225
1899-2439
Pojawia się w:
Prace Instytutu Odlewnictwa
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Zastosowanie rentgenowskiej tomografii komputerowej do porównania metody niskociśnieniowego odlewania przeciwgrawitacyjnego i metody odlewania grawitacyjnego
Application of X-ray computed tomography to compare gravity casting to counter-gravity low-pressure air-melted process
Autorzy:
Krzak, I.
Jaśkowiec, K.
Tchórz, A.
Boroń, Ł.
Powiązania:
https://bibliotekanauki.pl/articles/391421.pdf
Data publikacji:
2015
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Odlewnictwa
Tematy:
niskociśnieniowe odlewanie przeciwgrawitacyjne (CLA)
rentgenowska tomografia komputerowa (CT)
nieciągłość strukturalna
counter-gravity low-pressure air-melted casting (CLA)
X-ray computed tomography (CT)
structural discontinuities
Opis:
Celem niniejszej pracy była ocena struktury wewnętrznej odlewów zbliżonych do AlSi9Mg (EN AC-43300), wykonanych metodą niskociśnieniowego odlewania przeciwgrawitacyjnego w atmosferze powietrza – CLA (Counter-gravity Low-pressure Air-melted – powietrzne, niskociśnieniowe odlewanie przeciwgrawitacyjne) oraz metodą grawitacyjną. Metodę rentgenowskiej tomografii komputerowej – CT (Computed Tomography) w połączeniu z badaniami strukturalnymi i mechanicznymi, zastosowano do oceny jakości odlewów wytworzonych wyżej wymienionymi technikami. Nieciągłości strukturalne odlewów wykonanych metodą CLA i metodą grawitacyjną zbadano, analizując wyniki prześwietlania przemysłowym tomografem komputerowym firmy Phoenix X-ray. Przykładowo przedstawiono je w postaci wybranych przekrojów (2D) i w wizualizacji przestrzennej (3D). Z uwagi na fakt, że same badania tomograficzne okazały się niewystarczające, dla porównania jakości odlanych próbek różnymi technikami, przeprowadzono badanie mikrostruktury z wykorzystaniem mikroskopu świetlnego oraz wykonano statyczną próbę rozciągania próbek w temperaturze otoczenia.
The purpose of this paper is to evaluate the internal structure of alloys similar to AlSi9Mg (EN AC-43300), made with the counter-gravity low-pressure air-melted process (CLA) and with the gravity casting process. The X-ray computed tomography (CT) examination method was combined with structural and mechanical testing for a qualitative evaluation of the castings produced with these processes. The structural discontinuities in CLA and gravity castings were investigated by studying the imaging made with an industrial- grade CT scanner manufactured by Phoenix X-ray. The examples of images are shown on selected cross-sections (2D) and by 3D visualisation. The CT examination proved to be insufficient for a qualitative comparison of castings produced with different techniques; hence a microstructural examination was carried out under an optical microscope and a static tensile test was completed on the samples at ambient temperature.
Źródło:
Prace Instytutu Odlewnictwa; 2015, T. 55, nr 1, 1; 11-21
1899-2439
Pojawia się w:
Prace Instytutu Odlewnictwa
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Zastosowanie rentgenowskiej tomografii komputerowej do wspomagania badań materiałowych odlewów
The use of X-ray computed tomography as a tool in assisting cast material testing
Autorzy:
Krzak, I.
Tchórz, A.
Powiązania:
https://bibliotekanauki.pl/articles/391540.pdf
Data publikacji:
2015
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Odlewnictwa
Tematy:
rentgenowska tomografia komputerowa (CT)
badania defektoskopowe
niskociśnieniowe odlewanie przeciwgrawitacyjne (CLA)
szybkie prototypowanie (RP)
inżynieria odwrotna (RE)
X-ray computed tomography (CT)
flaw detection
counter-gravity low-pressure air-melted casting (CLA)
Rapid Prototyping (RP)
reverse engineering (RE)
Opis:
Technologia wytwarzania odlewów zależna jest od wielu czynników. Warunki techniczne odbioru odlewów określają wymaganą jakość, co jest podstawą do uznania odlewu za dopuszczalny bądź wadliwy. W praktyce produkcja odlewów bez pewnej ilości sztuk wadliwych nie jest możliwa. Dąży się jednak do zminimalizowania strat, stosując różnorodną aparaturę kontrolno-pomiarową. Do sprawdzenia wewnętrznej struktury wyrobu pomocna może być rentgenowska tomografia komputerowa (ang. Computed Tomography – CT). Jest to nowoczesna metoda diagnostyczna, która łączy badania rentgenowskie z zaawansowaną technologią komputerową. Badania tomograficzne umożliwiają bezinwazyjną jakościową ocenę badanego materiału oraz przeprowadzenie zaawansowanych analiz. Jedną z podstawowych zalet rentgenowskiej tomografii CT jest zobrazowanie badanych struktur w trzech wymiarach oraz możliwość wykonania rekonstrukcji przestrzennych. Przedmiotem artykułu jest przybliżenie zasady działania rentgenowskiej tomografii komputerowej oraz omówienie szerokiego jej wykorzystania w różnych dziedzinach nauki, w szczególności w badaniach defektoskopowych, w ilościowych badaniach metalograficznych, w procesie inżynierii odwrotnej (rekonstrukcyjnej) oraz w badaniach metrologicznych. Na wybranych przykładach przedstawiono możliwości rentgenowskiej tomografii komputerowej.
Casting manufacture depends on many factors. Technical specifications determine the required quality, which is essential for casting acceptance or rejection. Practice shows that making castings without defects is simply not possible. However, the aim is to minimize rejects owing to the use of diverse instruments for measurements and control. A tool which may be helpful in checking the internal structure of products is the X-ray computed tomography (CT). CT is a modern diagnostic method that combines X-ray examinations with advanced computer technology. Tomographic studies allow non-destructive qualitative assessment of the test material combined with advanced analysis. One of the main advantages of the X-ray computed tomography is imaging of the examined structure in three dimensions and the ability to perform spatial reconstruction. The aim of this article is to describe the principle operation of X-ray computed tomography and offer extensive discussion of its use in various fields of science, in particular to defect detection, quantitative metallographic tests, the process of reverse engineering (reconstruction) and metrological studies. Selected examples were used to show the potential offered by this technique.
Źródło:
Prace Instytutu Odlewnictwa; 2015, T. 55, nr 3, 3; 33-42
1899-2439
Pojawia się w:
Prace Instytutu Odlewnictwa
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Methods for designing and fabrication large-size medical models for orthopaedics
Autorzy:
Kudasik, T.
Libura, M.
Markowska, O.
Miechowicz, S.
Powiązania:
https://bibliotekanauki.pl/articles/200776.pdf
Data publikacji:
2015
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
computed tomography
CT
orthopaedic surgery
computer assisted surgery
CAS
rapid prototyping
RP
Opis:
Computed tomography and rapid prototyping techniques can be used to construct and fabricate large size bone models for orthopaedics. Rapid Prototyping technology enables the fabrication of a true-to-scale bone joint model based on 3D virtual models, generated by segmenting patients’ CT images. The model can be used to plan, to simulate, to assist prosthesis implantation for difficult cases of THR (Total Hip Replacements). The main restriction of implementing such models into medical practice is high cost of their production. Physical models of pelvic bones, were constructed on the basis of data collected during standard CT examinations. A method of development of a large-size model while fulfilling the requirement for reducing the price of model fabrication in the article was presented. The method can be used for fabrication the models with 3DP technique. This paper also discusses the issue of production costs when utilizing other RP techniques as well as their usefulness in practice.
Źródło:
Bulletin of the Polish Academy of Sciences. Technical Sciences; 2015, 63, 3; 623-627
0239-7528
Pojawia się w:
Bulletin of the Polish Academy of Sciences. Technical Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Methods of reconstructing complex multi-structural anatomical objects with RP techniques
Autorzy:
Kudasik, T.
Miechowicz, S.
Powiązania:
https://bibliotekanauki.pl/articles/202044.pdf
Data publikacji:
2016
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
medical modelling
rapid prototyping
computed tomography
CT
experimental tests
modelowanie medyczne
szybkie prototypowanie
tomografia komputerowa
badania doświadczalne
Opis:
This article presents reconstruction methods applied to a (geometrically and physically) complex structural object with the use of RP and RT techniques. The methods are innovative due to their hybrid - multi-model and multi-material - approach to reconstruction, as well as the application of multiple technologies. An experimental analysis was conducted to verify the feasibility of rapid prototyping (RP) techniques in the reconstruction of complex internal structures using materials of diverse properties. Some RP techniques offer the possibility of discriminating between diverse objects through the use of different colours. Such models are well-suited for diagnostic purposes, for better visualisation of complex clinical problems, pathological alterations, etc. Nevertheless, they fail to fully reflect physical and mechanical properties of objects, which renders them useful in experimental analysis only to a limited extent. Their basic drawback is that they merely reflect geometrical features of the examined object. The methods discussed in the present article enable modelling multi-object structures in a single process based on the PolyJet Matrix technology and materials of different physical properties by means of a hybrid method. The article also describes the process of modelling complex anatomical structures of soft tissues and bones using models of the maxilla and the mandible as examples. The study is based on data acquired through standard computed tomography (CT). In addition, the article addresses selected aspects of CT acquisition, generation of numerical models composed of several anatomical structures (objects) and fabricating physical multi-object models.
Źródło:
Bulletin of the Polish Academy of Sciences. Technical Sciences; 2016, 64, 2; 315-323
0239-7528
Pojawia się w:
Bulletin of the Polish Academy of Sciences. Technical Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Zastosowanie tomografii komputerowej w kardiologii - praca przeglądowa
Computer tomography in cardiology – a short review
Autorzy:
Kuniej, T.
Derkacz, A.
Powiązania:
https://bibliotekanauki.pl/articles/261256.pdf
Data publikacji:
2009
Wydawca:
Politechnika Wrocławska. Wydział Podstawowych Problemów Techniki. Katedra Inżynierii Biomedycznej
Tematy:
spiralna tomografia komputerowa
koronarografia TK
choroba wieńcowa
spiral computed tomography
coronary artery disease
CT coronography
Opis:
rozdzielczością przestrzenną i czasową oraz z przyspieszeniem akwizycji, pozwolił na wiarygodne obrazowanie serca i naczyń wieńcowych. Klasyczna angiografia pozostaje złotym standardem w wykrywaniu zwężenia naczyń wieńcowych, jednakże wymagania terapeutyczne wymuszają poszukiwanie mniej inwazyjnych metod diagnostycznych. Wielorzędowa tomografia komputerowa jest nieinwazyjną metodą obrazowania, pozwalającą na diagnostykę chorób serca, naczyń wieńcowych oraz zmian patologicznych, takich jak na przykład restenoza w pomostach naczyń wieńcowych czy stentach, zatorowość płucna lub tętniak rozwarstwiający aorty, które są trudne do wykrycia za pomocą innych technik.
In recent years, improvements in multislice computed tomography in terms of spatial and temporal resolution, as well as short acquisition time have enabled reliable diagnostics of the heart and coronary arteries. Conventional coronary angiography is valuable method for the detection of coronary stenosis, however due to the requirements of many therapeutic procedures, there is an increasing demand for less invasive diagnostic methods. Multislice CT is a noninvasive imaging modality suitable to detect many cardiac and coronary and extracardiac pathologies, like e.g. by-pass and stent restenoses, pulmonary embolism or aortic dissection that are difficult to detect by any other modality.
Źródło:
Acta Bio-Optica et Informatica Medica. Inżynieria Biomedyczna; 2009, 15, 3; 273-276
1234-5563
Pojawia się w:
Acta Bio-Optica et Informatica Medica. Inżynieria Biomedyczna
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Verification of the Computed Tomography Results of Aluminum Alloy Welded Joint
Autorzy:
Malicki, M.
Sobczak, K.
Powiązania:
https://bibliotekanauki.pl/articles/97855.pdf
Data publikacji:
2018
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Lotnictwa
Tematy:
computed tomography
CT
welded joints
defects
microcracks
Opis:
Computed tomography (CT) of aluminum welded joint specimen has been performed. On the tomographic cross sections some defects have been found. To verify them the metallography cross sections of welded has been done. It was found that selected defects are micro cracks.
Źródło:
Fatigue of Aircraft Structures; 2018, 10; 47-52
2081-7738
2300-7591
Pojawia się w:
Fatigue of Aircraft Structures
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies