Tytuł:
A Review of LCC-HVDC and VSC-HVDC Technologies and Applications
Autorzy:
Oni, O. E.
Mbangula, K. I.
Davidson, I. E.
Powiązania:
https://bibliotekanauki.pl/articles/136148.pdf
Data publikacji:
2016
Wydawca:
EEEIC International Barbara Leonowicz Szabłowska
Tematy:
commutation failure
HVDC
line commutated converter
modular multilevel converter
voltage source converter (VSC)
Opis:
High Voltage Direct Current (HVDC) systems has been an alternative method of transmitting electric power from one location to another with some inherent advantages over AC transmission systems. The efficiency and rated power carrying capacity of direct current transmission lines highly depends on the converter used in transforming the current from one form to another (AC to DC and vice versa). A well-configured converter reduces harmonics, increases power transfer capabilities, and reliability in that it offers high tolerance to fault along the line. Different HVDC converter topologies have been proposed, built and utilised all over the world. The two dominant types are the line commutated converter LCC and the voltage source converter VSC. This review paper evaluates these two types of converters, their operational characteristics, power rating capability, control capability and losses. The balance of the paper addresses their applications, advantages, limitations and latest developments with these technologies.
Źródło:
Transactions on Environment and Electrical Engineering; 2016, 1, 3; 68-76
2450-5730
Pojawia się w:
Transactions on Environment and Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Warunki pracy otoczenia sieciowego a praca łącza HVDC SwePol Link
Power network operating conditions vs HVDC SwePol Link operation
Autorzy:
Przygrodzki, M.
Rzepka, P.
Szablicki, M.
Powiązania:
https://bibliotekanauki.pl/articles/266869.pdf
Data publikacji:
2015
Wydawca:
Politechnika Gdańska. Wydział Elektrotechniki i Automatyki
Tematy:
łącze HVDC
technologia LCC
przewrót komutacyjny
HVDC cable line
Line Commutated Converters
commutation failure
Opis:
W pracy łącza HVDC SwePol Link rejestruje się zakłócenia związane z wyzwalaną sieciowo komutacją tyrystorów (przewroty komutacyjne) powstające w trakcie importu energii elektrycznej do Polski. Przewrót komutacyjny może prowadzić do wyłączenia łącza i w efekcie do ograniczeń w realizacji wymiany mocy między Polską i Szwecją. Dodatkowym skutkiem wyłączenia łącza mogą być defekty techniczne. W artykule przedstawiono wyniki przeprowadzonej analizy przyczynowo-skutkowej wpływu funkcjonowania sieci zamkniętej w północnym rejonie Krajowego Systemu Elektroenergetycznego na zakłócenia w pracy łącza HVDC SwePol Link.
The HVDC SwePol Link allows the power and energy exchange between Poland and Sweden. Disturbances of HVDC SwePol Link operation occur during energy import to Poland. The connection between Poland and Sweden was establish in 2000 and consist of a bipolar HVDC cable line and two AC/DC converter stations, one in Slupsk (the Polish power system side) and the second one in Stärnö (the Swedish power system side). The reason of identified disturbances was events in polish power network, which can cause commutation failure. That commutation failure could lead to switching off the HVDC SwePol Link and additionally resulting in unexpected limitation of power exchange between Poland and Sweden. The paper will present results of cause-and-effect analysis of Polish power system in terms of interference with the HVDC SwePol Link. Events leading to the occurrence of commutation failure will be described as well as impact assessment of different AC power system operation states in network-area of Slupsk substation. Commutation failure phenomenon in some cases caused some damages. According to that facts an important element of the paper will be a quantitative description of the commutation failure that occur during the lifetime of the HVDC SwePol link.
Źródło:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej; 2015, 42; 85-83
1425-5766
2353-1290
Pojawia się w:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Influence of Power System on Operation of an HVDC Link. A Case Study
Wpływ otoczenia sieciowego na pracę łącza HVDC. Studium przypadku
Autorzy:
Przygrodzki, M.
Rzepka, P.
Szablicki, M.
Powiązania:
https://bibliotekanauki.pl/articles/397471.pdf
Data publikacji:
2016
Wydawca:
ENERGA
Tematy:
HVDC link
converter substation
LCC technology
commutation failure
łącze HVDC
stacja przekształtnikowa
technologia LCC
przewrót komutacyjny
Opis:
An HVDC link enables power and energy exchange between unsynchronised power grids. Large possibilities of controlling active power flows through such systems enable commercial transfers, as well as emergency power balancing operations. During operation of an HVDC SwePol Link disturbances related to thyristor commutation triggered by the grid (commutation failures) are observed; these occur during power import (inverting operation) to  Poland. A  commutation failure may lead to an outage of the HVDC link and therefore restrict power exchange with Sweden. An outage may additionally cause some technical defects (e.g. damage of return cable insulation). This damage may lead to long outages of the link, and repairing it may be quite expensive. The paper presents results of the cause-effect analyses of the closed grid operation in the northern area of the National Power System, in the context of disturbances in operation of the HVDC SwePol Link. Events related to commutation failures have been analysed; the influence of operating conditions in the grid near an HVDC link on such occurrences has been evaluated. So far, during the operation of the link such a phenomenon has occurred more than 200 times, and some of the events led to the system shut-down. In a few cases some link components were damaged in the process.
Połączenie HVDC umożliwia wymianę mocy i energii pomiędzy systemami elektroenergetycznymi, które pracują niesynchro- nicznie. Duże możliwości kontroli przepływów mocy czynnej w tego typu układzie pozwalają zarówno na wymianę handlową, jak i korektę bilansu mocy w sytuacjach awaryjnych. W pracy łącza HVDC SwePol Link rejestruje się zakłócenia związane z wyzwalaną sieciowo komutacją tyrystorów (w charakterze tzw. przewrotów komutacyjnych), powstające w trakcie importu mocy (praca falow- nikowa) do Polski. Przewrót komutacyjny może prowadzić do wyłączenia łącza HVDC i w efekcie ograniczeń w realizacji wymiany mocy ze Szwecją. Dodatkowym skutkiem wyłączenia łącza mogą być defekty techniczne (przykładowo: uszkodzenia izolacji kabla powrotnego). Uszkodzenia te są przyczyną długich przerw w pracy łącza, a ich usunięcie wymaga niejednokrotnie znacznych nakładów finansowych. W artykule przedstawiono wyniki przeprowadzonej analizy przyczynowo-skutkowej funkcjonowania sieci zamkniętej w północnym rejonie Krajowego Systemu Elektroenergetycznego (KSE) w aspekcie zakłóceń pracy łącza HVDC SwePol Link. Przeanalizowano zdarzenia związane z występowaniem przewrotów komutacyjnych i przeprowadzono ocenę wpływu warunków pracy otoczenia sieciowego łącza HVDC na występowanie tego zjawiska. W dotychczasowej pracy łącza zjawisko to wystąpiło ponad 200 razy, w tym część zakłóceń zakończyła się wyłączeniem układu, a w kilku przypadkach zdarzeniem towarzyszącym było uszkodzenie elementów składowych łącza.
Źródło:
Acta Energetica; 2016, 1; 114-119
2300-3022
Pojawia się w:
Acta Energetica
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Selected Aspects of Interaction of DC Transmission Systems in Thyristor (LCC HVDC) and Transistor (VSC HVDC) Technologies
Wybrane aspekty interakcji układów przesyłowych prądu stałego w technologii tyrystorowej (LCC HVDC) i tranzystorowej (VSC HVDC)
Autorzy:
Kosmecki, M.
Madajewski, K.
Powiązania:
https://bibliotekanauki.pl/articles/952891.pdf
Data publikacji:
2018
Wydawca:
ENERGA
Tematy:
DC transmission system
HVDC
VSC
LCC
commutation failure
interaction
voltage stability
układ przesyłowy prądu stałego
przewrót komutacyjny
interakcja
stabilność napięciowa
Opis:
The paper presents the problem of interaction between an LCC HVDC system and a VSC HVDC system. It was shown that the separate operation of an LCC HVDC system under low short circuit power conditions is possible and that at this level of short circuit power it is possible to transfer the same active power through the VSC HVDC system operating in parallel, under the condition that the inverter of this connection operates in AC voltage regulation mode. On the other hand, in certain circumstances it is this mode that may cause the LCC system operating conditions to worsen, which indicates the need for a careful analysis of such cases in order to properly adjust the settings of the relevant control systems. It has been shown that the settings of the voltage regulation system and the PLL system under normal short circuit power conditions can improve the process of the LCC HVDC system returning to operation post-disturbance, while in the conditions of reduced short circuit power they make this process more difficult.
W artykule przedstawiono problem interakcji pomiędzy układem LCC HVDC a VSC HVDC. Pokazano, że samodzielna praca układu LCC HVDC w warunkach niskiej mocy zwarciowej jest możliwa oraz że przy tym poziomie mocy zwarciowej możliwe jest dodatkowe wyprowadzenie takiej samej mocy czynnej przez równolegle pracujący układ VSC HVDC, pod warunkiem że falownik tego łącza będzie pracował w trybie regulacji napięcia AC. Z drugiej strony w określonych okolicznościach to właśnie ten tryb może być przyczyną pogorszenia warunków pracy układu LCC, co wskazuje na potrzebę dokładnej analizy takich przypadków w celu właściwego doboru nastaw odpowiednich układów regulacji. Pokazano bowiem, że nastawy układu regulacji napięcia i układu PLL w warunkach normalnej mocy zwarciowej potrafią usprawnić proces powrotu do pracy układu LCC HVDC po zakłóceniach, natomiast w warunkach obniżonej mocy zwarciowej ten proces utrudniają.
Źródło:
Acta Energetica; 2018, 3; 77-85
2300-3022
Pojawia się w:
Acta Energetica
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-4 z 4

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies